This solicitation seeks proposals for the procurement and installation of a 75 ton bridge crane at a naval facility. Offerors should provide pricing to design, fabricate, deliver, install, test, and commission the bridge crane in accordance with specifications. Proposals are due by April 5, 2021 and the Navy intends to award a fixed-price contract by May 3, 2021. The crane must have a minimum capacity of 75 tons, span 120 feet, and include a programmable logic controller and human-machine interface for operation and troubleshooting. The Naval Supply Systems Command is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| C08.7 Solicitation N4523A21Q5722 Q&A#3.pdf | ||
| C08.6.0 10514 B431 CLEARANCE DIAGS FOR TRAV CRANES.pdf | ||
| C08.6 Solicitation N4523A21Q5722 Q&A #2.pdf | ||
| C08.0.2 Attachment 2 Badging Requirements 07-01-2021.pdf | ||
| C08.0.0 Exhibit A FAR Provision 52.204-24_SUBMIT WITH QUOTE.doc | DOC document | |
| C08.0.3 Attachment 3 Corporate Experience Data Sheet.docx | DOCX document | |
| C08.0.1 Attachment 1 SOW Bridgecrane 06-15-2021.pdf | ||
| C08.0 N4523A21Q5722 Combined Synopsis Solicitation.pdf | ||
| C08.0.4 Attachment 4 Visitor Badge Request.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation N4523A21Q5722 75 Ton Bridge Crane Q&A #1
Q: The specification states PLC and HMI, is this application needing a PLC/HMI?
A: If the Offeror uses a PLC and/or HMI in the design, then the Offeror must meet the requirements in paragraph 1.4.5.6.1 and 2.2.14.1. HMI’s help the end user troubleshoot the equipment without opening the cabinets, depending on how they are setup. HMI’s are typically stand alone and do not interfere with a specific function. PLC’s tend to use less space in control cabinets.