FCB20-008_MN_FEED_PUMP_INSPECTION.docx

DOCX document 26 KB Posted

Attached to
FCB 20-008 Main Feed Pump Survey and Calibration
Solicitation number
N4044619Q0053
Issued by

About this file

Performance Work Statement

View the file

Other files

File Type Posted
Wage_Determination_V_9.pdf PDF
COMBINED_SYNOPSIS_SOLICITATION_N4044619Q0053.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SERVICE ORDER REQUEST - MSC SSU GUAM

MAIN FEED PUMP SURVEY AND CALIBRATION

VESSEL:
USS FRANK CABLE (AS-40)
Port Engineer:
ARSENIO QUEJADO
Phone
671-339-5342/480-6500
DATE:
13AUG2019
SSU JOB#
FCB20-008

VRR#

CASREP#

1.0ABSTRACT:
1.1This item describes the requirement to provide Coffin Turbo Pump Field Technician to perform 5 YEARS inspection and Surveys.
2.0REFERENCES:
2.1Coffin Turbo Pump Instruction Manual
3.0ITEM LOCATION/DESCRIPTION:
3.1Location/Quantity: Fire Room (7-123-0-E)
3.2Item Description/Manufacturer's Data: QTY: QTY: 2 EA Turbine-Driven Centrifugal Boiler Feed Water Pump Coffin Mode “D

4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES: None

5.0 NOTES:

5.1The contractor and subcontractors must consult Military Sealift Command’s General Technical Requirements, (GTR’s), to determine applicability to this work item. The contractor and all subcontractors must comply with all applicable GTR requirements.
5.2Contractor shall obtain and maintain base/pier access all throughout the duration of Period of Performance (POP).
5.3Contractor shall submit a Ships Access List within 96 hours prior to start of POP for all contractor and sub-contractor personnel all throughout the duration of POP.
5.4Contractor shall notify MSCREP and ABS Surveyor no later than 24 HR to witness all inspection and testing specified in this Work Item.
5.5MSCREP consist of Port Engineer and Chief Engineer or his designated representative.

6.0 QUALITY ASSURANCE REQUIREMENTS:

6.1 The requirements of this Work Item shall be accomplished to the satisfaction of the MSCREP.

6.2 The requirements of this Work Item shall be accomplished in accordance with current Regulatory Body rules and regulations.

7.0 STATEMENT OF WORK REQUIRED:

7.1 Provide the services of a Qualified Coffin Turbo Pump Field Technician to accomplish 5-Year Inspections and Surveys, to include observing the pumps in full operation, disassembly, inspection and replacement of internal component of the pumps. In addition, remove and factory test and reinstall in accordance with reference 2.1.

7.1.1 Submit a type written report to the MSCREP listing the results of the test and inspection work accomplished in 7.1.1 in accordance with reference 2.1.

7.1.2 Contractor to provide the following OEM materials:

Item #
Item Name
Part #
Quantity
7.1.3.1
Cotter Pin
17318
4
7.1.3.2
Thrust Bearing Lock Washer
17446
2
7.1.3.3
Thrust Bearing
17458
2
7.1.3.4
Inner Separator
22474
2
7.1.3.5
Outer Separator
22474
2
7.1.3.6
Thrust Bearing Cover Gasket
18309
2
7.1.3.7
Thrust Bearing Deflector
17408
2
7.1.3.8
Main Bearing
17056
4
7.1.3.9
Main Bearing Deflector
17066
4
7.1.3.10
Main Bearing Cover Gasket
18306
4
7.1.3.11
Main Bearing Retainer
19311
4
7.1.3.12
LO Sump Cover Gasket
17299
2
7.1.3.13
Turbine Stator Bolt Gasket
18347
10
7.1.3.14
Turbine Shaft Gland
18565
2
7.1.3.15
Turbine Rotor Sleeve
17065
2
7.1.3.16
Turbine Cover Gasket
19370
2
7.3.1.17
L.H Wear Ring
17415
2
7.3.1.18
R.H. Wear Ring
17414
2
7.3.1.19
L.H. Impeller Inlet
17623
2
7.3.1.20
R.H. Impeller Inlet
17419
2
7.3.1.21
Mechanical Seal
19958
4
7.3.1.22
Inboard Shaft Sleeve
19967
2
7.3.1.23
Outboard Shaft Sleeve
19969
2
7.3.1.24
Gasket
19985
2
7.3.1.25
Gasket
18615
2
7.3.1.26
Gasket
21617
2
7.3.1.27
Gasket
18652
2
7.3.1.28
Gasket
18294
2
7.3.1.29
Upper Guide
21795-2
2
7.3.1.30
Oil Filter Cartridge
25013-6
4
7.2Inspection/Test:
7.2.1Accomplish and Operational Test of each pump in the presence of MSC Representative, Chief Engineer and ABS Surveyor.
7.3Manufacturer's Representative:
7.3.1COFFIN TURBO PUMP INC
326 South Dean Street
Englewood, NJ 07631
POC: Joe Motisi
Phone: +1-201-568-4700 x257

Fax: +1-201-568-4716 Mobile: +1-973-296-5340 Email: jmotisi@coffinpump.com

8.0 GENERAL REQUIREMENTS:

8.1POP: 21 Oct – 27 Nov 2019.
8.2Location: Uniform Pier, Naval Base Guam.
8.3Shipping Address for Materials listed in 7.1.3:
MSC SSU Guam
ATTN Arsenio Quejado

NAVY BASE GUAM

BLDG 3110, K1 WHSE

SANTA RITA GU 96915

FCB20-007-2