USNS diehl
T-AO 193
| AUX MACHINERY |
| Service Order |
18 MAY 2018
ITEM NO 510
MSC/TRB
PORT AND STBD REDUCTION GEARS INSPECT AND TROUBLESHOOT
CASREP 18-012
1.0 ABSTRACT
1.1 Provide the services of an OEM Siemens/Flender Field Service Tech Rep to open, inspect, and troubleshoot an elevated temperature bearing problem for the port and stbd main engine reduction gears.
2.0 REFERENCES / ENCLOSURES:
2.1 NAVSEA TECH MANUAL, T9241-AJ-MMC-010, MAIN PROPULSION REDUCTION GEAR AND PTO CLUTCH/COUPLING (for Diehl only)
3.0 ITEM LOCATION/DESCRIPTION
Location: Engine Room, Lower Level (4-60-0) Nomenclature: LOHMAN STOHLTERFOHT gearbox, type GUH 1700 / 1259+1260 / 247002
4.0 GOVERNMENT FURNISHED MATERIAL: None
5.0 NOTES:
5.1 Period of Performance (POP): 20 - 24 OCT 2018
5.2 Location: Singapore
The Contractor shall request access to the ship immediately upon contract award. All contractors shall fill out EPIC form and submit to the following MSC Security Administration personnel:
Joanne Kim: joanne.kim.ctr@navy.mil
David Laden: david.laden.ctr@navy.mil Francis Lacerna, Francis.lacerna.ctr@navy.mil
6.0 QUALITY ASSURANCE REQUIREMENTS: None Additional
7.0 STATEMENT OF WORK
7.1 Open, inspect, and troubleshoot the ship’s L&S gearbox to determine the cause of the elevated bearing temperature. This is to include for the PTO cover to be dismounted and to perform a closer inspection of the slide/thrust bearing.
7.2 Reference 2.1 provides information on the PTO FOWARD and AFT Bearing Settings.
7.3 Provide a report of all findings with recommendations for corrective action.
7.4 Known Lohmann & Stoltefoht OEM company:
FLENDER
Philadelphia PA POC: Rodrigo Almeida, Phone: 215-718-7326 Rodrigo.Almeida@Flender.com rodrigo.almeida@siemens.com
8.0 GENERAL REQUIREMENTS: None Additional