N00253-16-T-0075 QUESTIONS & ANSWERS
QUESTION: Noted there is no call out for radius on the inside corners on mounting tabs. Thus a sharp edge is left in the corners. Over time, it's very possible that vibrations would cause cracks. I would recommend a .0625-.125 radius to relieve that stress edge. Please let me know if this is permissible.
ANSWER: No, the recommended deviation from the drawing is not permissible. So the parts must be manufactured In Accordance With the Drawing PESK – 5395
QUESTION: “do you have a solid model for this print”
ANSWER: No solid models will be provided for this part
QUESTION: "Could we get a dxf file of this part?"
ANSWER: No, DXF format Not Available.
QUESTION: On drawing PESK-5395, there is a dimension missing.
. On the bottom view, zone A6, there are two holes .094 dia with a .175 dia countersink.
. On the top view, zone D6, the holes are dimensioned from the right edge.
. There are no dimensions for these holes in the other direction, top to bottom."
ANSWER: The dimensions in Y are given in the top view, zone D4: .793 and 1.593 respectively from Datum B.
File details come from the government source that posted it. Updated .