Attachment_J.5_-_Grid.pdf
PDF 357 KB Posted
- Attached to
- Facility Renovations Federal contract opportunity
- Solicitation number
- N0017819R2318
About this file
This combined synopsis and solicitation requests quotations for facility maintenance and upgrades at Building 1490 located at 19008 Wayside Dr., Dahlgren, VA. The Naval Surface Warfare Center, Dahlgren Division requires work within existing structures to be performed using simplified acquisition procedures. Quotes are due by October 15, 2019 for a firm fixed price order. The requirement is eligible for small business set-aside. Offerors must be registered in the System for Award Management and provide security documentation for any required site visits by September 13. Attachments include category of work classifications, facility drawings, ceiling and grid specifications, government property terms, and wage determinations.
J.5 Grid
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_J.8_-_DBA_Wage_Determinations_Rev.1.pdf | ||
| N0017819R23180002.pdf | ||
| N0017819R23180001.pdf | ||
| Attachment_J.4_-_Ceiling_Tile.pdf | ||
| Attachment_J.8_-_DBA_Wage_Determinations.pdf | ||
| Attachment_J.2_-_1490_RM2038.pdf | ||
| Attachment_J.7_-_SCA_Wage_Determinations.pdf | ||
| Attachment_J.9_-_Site_Visit_Documentation.pdf | ||
| Attachment_J.3_-_2vtl-2x2.pdf | ||
| Attachment_J.1_-_NAVFAC_Capital_Improvements_Categories_of_Work_Classification.pdf | ||
| Attachment_J.6_Government_Furnished_Property.pdf | ||
| N0017819R2318.RFP.Final.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
datasheet
800.323.7164 / Fax: 800.222.3744 / rockfon.com
G Cei l ing Suspension / 09120
Primary Applications:
Retail, classrooms, general interiors.
Features and Benefits:
n The industry standard of compatibility: acoustical panels, light fixtures and air diffusers.
n Snap-in demountable (hook-type) cross tees.
n Butt-cut cross tees.
n Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E1264-08.
n Quick access to ceiling plenum.
n Butt-cut cross tees provide true, flat panel installation, i.e., metal panels.
n Cost control.
n Global compatibility and availability.
n Sustainable: Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture.
Main Tees
1 1/2
15/16
Double web construction, 15/16” width, 1-1/2” height.
For Modules Sized (24 x 24, 24 x 48) 216.01H (120”, slots 6” OC, ID) 200.01H (144”, slots 6” OC, HD) 211.01H (144”, slots 6” OC, ID)
For Modules Sized (20 x 30, 20 x 60, 30 x 30, 60 x 60) 299.01H (120”, slots 10” OC, ID)
Cross Tees
Double web construction, 15/16” width, 1-1/2” height.
Snap-in end detail.
For Modules Sized (24 x 24, 24 x 48) 251.01H (12”, no slots) 229.01H (24”, no slots) 253.01H (36”, slots 12” OC) 209.01H (48”, slots 12” OC)
For Modules Sized (20 x 30, 20 x 60, 30 x 30, 30 x 60, 60 x 60) 257.01H (20”, no slots) 258.01H (30”, no slots) 207.01H (60”, slots 6” OC) 278.01H (96”, slots 12” OC)
Wall Angles
A
B two hemmed edges
Wall Angle, two hemmed edges (A x B):
1430.01 (144”, 7/8” x 7/8”) 1420.01 (144”, 15/16” x 15/16”) 1428.01 (144”, 1” x 2”) 1425.01 (144”, 2” x 2”) 21420.01 (144”, 15/16” x 15/16”) 1421.01 (120”, 15/16” x 15/16”)
Shadow Moldings
1460, 1461/1469 one/two hemmed edge
A
B
C
D
Shadow Moldings, one hemmed edge (A x B x C x D)
1460.01 (120”, 3/4” x 3/8” x 3/8” x 3/4”) 1461.01 (120”, 3/4” x 3/4” x 3/4” x 3/4”)
Shadow Molding, two hemmed edges (A x B x C x D)
1469.01 (120”, 15/16” x 3/8” x 3/8” x 9/16”) two hemmed edges
A
B
C
D
Shadow Molding, two hemmed edges (A x B x C x D)
1466.01 (144”, 1-3/4” x 3/4” x 1/4” x 1-1/4”)
PRODUCTS
Chicago Metallic 200 Snap Grid™
15/16” Exposed backoffice Highlight backoffice Highlight backoffice Highlight backoffice Highlight
ROCKFON, LLC 4849 SOUTH AUSTIN AVE., CHICAGO, IL 60638 / USA and Canada: 800-323-7164 / Fax: 800-222-3744 / rockfon.com
Date: 06.2014 | Subject to alterations in range and product technology without prior notice. ROCKFON accepts no responsibility for printing errors. SNL0060E2014
G Cei l ing Suspension / 09120
DETAILS
Chicago Metallic 200 Snap Grid™ 15/16” Exposed
MATERIAL
COMPONENT LOAD TEST DATA (based on 1/360 span deflection)
LIGHT FIXTURE LOAD TEST DATA (based on 1/360 span deflection)
LIGHT FIXTURES MAIN & CROSS TEES -
ALLOWABLE FIXTURE WT. – LBS.
Dimensions 200
1’ x 4’ 32.4 56.4
2’ x 2’ 29.2 34.8
2’ x 4’ 40.8 47.2
2’ x 5’ 40.8
3’ x 3’ 63.0▲
20” x 48” 37.6
20” x 60” 37.6
NON-FIRE RATED ASSEMBLIES
Hanger Positions for Non-Fire Rated Situations
This illustrates hanger positions for single fixtures in a field.
Provide extra hangers for tandem fixtures.
A. General ASTM C 635 Heavy Duty (HD) and Intermediate Duty (ID) main tee classifications;
commercial quality HDG-30 steel, hot-dip galvanized body and cap, 15/16” width, 1-1/2” height.
Note: A metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed.
square edge reveal edge
ALLOWABLE LOAD n SIMPLE SPAN-lb/ft Hanger Spacing
Main Tee Length 4’ 5’ 6’
216 10’ ID 6.0 4.0
299 10’ ID 6.0 4.0
211 12’ ID 6.0 4.0
200 12’ HD 8.9 5.6
Cross Tee Length 1’ 20” 2’ 30” 3’ 4’ 5’ 6’ 8’ 251 12” – 257 20” 90.0▲
229 2’ 32.5▲
258 30” 57.4 253 3’ 34.7 209 4’ 9.1 207 60” 8.5 278 8’ 2.1 n To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.
* Hanger wire required at midpoint of tee.
▲ Limited by safety factor of 2.
File details come from the government source that posted it. Updated .