STANDARD FORM 36 JULY 1966

GENERAL SERVICES ADMINISTRATION

FED. PROC. REG. (41 CFR) 1-16.101

CONTINUATION SHEET
REF. NO. OF DOC. BEING CONT’D

N00173-15-Q-0323

PAGE OF

2 16

NAME OF OFFEROR CONTRACTOR

ALL QUOTERS

ITEM NO.
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT

Part #CAP591-38604A-1 CLEAN ROOM - Rigid Wall; CAP591-14x27x8H; ISO Class 7, Class 10,000; -(10) Filter Units - CAP117-424 variable speed control; (7) lights-CAP1210-2x4; Upgrade to a prefab wire kit for the filter units and lights-PWK591-10F7L; (2) doors - 44Wx84H anodized aluminum frame transparent clear acrylic panel; Upgrade to (1) internal rigid wall gown room - 6x4; (2) Magnehelic pressure gages; Transparent clear acrylic wall panels on (2) 14ft sides and gown room walls; White painted aluminum wall panels with polypropylene core on (2) 27ft sides; Upgrade to full wall recirculation on (2) 27ft walls; Double wall construction on (2) sides for air return, outside walls seal to the floor on both sides, roof panels on top to create a plenum, perimeter doors have a door sweep, fixed bottom;

Quote should not include: Temperature/Humidity controls, flooring, sprinklers and installation.

Upgrade to an A/C System - 10 ton, cooling only; Rejects heat to the existing space; Existing space should be large relative to the clean room; frame and duct work to connect to the clean room;Unit sets on the existing floor 480 volt, 3 Phase.

Quote should not include condensate drain plumbed, wiring to building and permits

Items must be brand name or equal.

If available, please include a published price list or a cost breakdown and return the RFQ package to Kerry Callahan at the following email: kerry.callahan@nrl.navy.mil