17RJN41_0003.pdf
PDF 88 KB Posted
- Attached to
- . 50 CALIBER REDUCED RANGE AMMUNITION
- Solicitation number
- N0016417RJN41
About this file
17RJN41_0003
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 17RJN41_0005.pdf | ||
| 17RJN41_0004.pdf | ||
| 17RJN41_sol_0002.pdf | ||
| 17RJN41_0001.pdf | ||
| 17RJN41_sol.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to provide answ ers to questions regarding the RFP and to modify technical specifications.Three (3) additional documents are provided, as w ell as a revision to Attachment 1.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 07-Feb-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N00164-17-R-JN41
X 9B. DATED (SEE ITEM 11)
12-Dec-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
08-Feb-2017
CODE
NAVAL SURFACE WARFARE CENTER CRANE DIV
C. ROBERTS (812-854-4702)
BLDG 3373
300 HWY 361
CRANE IN 47522-5001
N00164 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N00164-17-R-JN41
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SUMMARY OF CHANGES
Questions and Answers regarding N00164‐17‐R‐JN41 RFP:
1) Since there is no formal Doppler Radar test to be performed in the Sample phase, yet maximum range is a critical evaluated specification requirement, how does the US Government intend to uniformly assure that the maximum range specification claims submitted by each bidder is backed up and verified by real, tangible Doppler Radar test reports that the USG can review for verification?
Answer: As a part of the written technical proposal, vendors shall provide test method, equipment list, and test data. This is a deviation from the original written technical proposal requirement. See Written Technical Proposal Requirements Compliance Matrix_R1.
2) What type and length of barrel is used when undertaking the accuracy test?
Answer: Barrel Drawing 6545961 shall be provided. The barrel is a US military accuracy test barrel that is 36 in. in length
3) Which lot of M33 reference ammunition will be supplied during the contract?
Answer: The lot of reference ammunition to be supplied is still TBD.
4) What are the minimum and maximum "Average Mean Radii" values of the M33 reference lot that will be supplied during the contract?
Answer: Specification sections 3.8 and 4.5.4 for the Ball and Tracer shall be changed to the following:
3.8 Accuracy (Dispersion). The average of the mean radii of all targets of the sample cartridges, fired at 1000 m, shall be not greater than 17 in.
4.5.4 Accuracy (Dispersion). The test shall be conducted using methods and procedures in M‐SCATP Accuracy (Dispersion) with the following exceptions.
a. Equipment approved by NSWC Crane shall be used.
b. Rounds shall be conditioned at 70° ± 2°F and shall be fired at that temperature.
c. Targets (physical, acoustic sensors or radar) shall measure and record the location of each shot at 1000 meters.
d. For each target, a 10 shot group of MK 322/321 MOD 1 rounds shall be fired.
e. Measure the mean radius of each 10 shot group. For informational purposes only, measure extreme horizontal, extreme vertical, extreme spread, and center of impact of each 10 shot group.
5) Will the supplied M33 reference lot always be the same throughout the duration of the contract or could other reference lots be supplied, lots that have different "Average Mean Radii" values?
Answer: Reference ammunition will be limited to EPVAT testing only. See answer to 4 above
When a contractor supplies goods against the contract that will be awarded for the 50 caliber Reduced Range cartridges,
6) Do you have a requirement regarding the transport of a closed van from New York Port to Crane, IN with regard to the contractor's transporter using a single vs. dual drivers?
Answer: The transportation of small arms ammunition shall be in accordance with the Defense Transportation Regulation Part II, Chapter 205 Table 1. The document is provided for your reference.
7) In reference to Hardness requirements for case, Caliber 50 (Dwg. 13028542). Taking into consideration our currently implemented .50" case hardness, we kindly request approval to provide the required 320 rounds of BALL & Tracer samples with the same case hardness that we supplied during a previous contract.
Answer: The technical authority does not approve a waiver to hardness requirements called out in drawing 13028542. The vendor is allowed to take exception to a requirement and provide an alternative threshold for review.
8) In reference to Accuracy (Dispersion) Specification para. 3.8, the accuracy requirement dictates that it "shall not exceed the average of the mean radii of all reference groups when fired at 1000 meters".
As we do not have any USG P.N. 7553097 (NSN 1305005855191) reference cartridges please advise if we can receive reference cartridges in order to determine this requirement. Alternatively, if reference rounds are not available we request approval to provide the 320 cartridge samples with accuracy performance in accordance with the requirements of: MIL‐C‐10190D (M33 BALL) MIL‐C‐1318B
Answer: See answer in question 4 above.
9) Government Furnished Property (GFP): Please advise if following award the contractor will be entitled to receive on loan as GFP the .50" weapons required for testing this ammunition.
Answer: The vendor will be supplied the required weapons and accessories as GFP for function testing.
A listing of the GFP will be provided in an upcoming amendment.
10) Reference SOW: Para: 3.13.1.1 (Ballistic Match) page #5 Paragraph 3.13.1.1 begins:
"For linked Ball and Tracer configurations the average distance between centers of impact of all MK 322 MOD 1 Ball groups and all MK 321 MOD 1 Tracer groups shall not exceed 1.5 meters horizontal and 1.5 meters vertical when fired at 1000 meters ".
In contrast, the specifications of both cartridges (Exhibits "C" & "D") don't define a match test but only an accuracy (Dispersion test)‐para. 3.8
"The average of the mean radii of all MK 322 MOD 1 groups shall not exceed the average of the mean radii of all reference groups when fired at 1000 meters".
Are both of these tests required for the linked cartridges: the ballistic match test & the accuracy (dispersion test)?
Answer: Both the ballistic match and the accuracy (dispersion test) are required for linked configurations.
11) In Spec. para. 3.8 what is meant by the term: "reference groups"? We assume these are the USG reference rounds that will be supplied to the contractor. Is this correct?
Answer: Please see answer in question 4 above.
12) Reference Exhibits "C" & "D" ‐ cartridge specifications. Paragraphs 4.5.6.1 and 4.5.8 ("Velocity at extreme temperatures" & "Function and Casualty" respectively) state that after the ammunition will be conditioned at extreme temperatures it " "... shall be fired at that temperature.”
We assume that the intention here is that the ammunition must be fired immediately after its removal from either the cooling storage chamber or the heating storage chamber without delay. Please confirm.
Answer: The rounds shall be fired within 60 seconds of removal from the conditioning chamber. Please see M‐SCATP, DTL13038145.
13) We kindly request the following two technical documents:
1) NSWC Crane ‐ Equipment approval by NSWC Crane shall be used for ballistic match test
Answer: This statement is not a document and refers to the fact that NSWC Crane requires approval of any equipment used to perform the testing where referenced.
2) DI‐QCIC‐81960
Measurement system evaluation
Answer: Please see the attached.
CNIN-L-0002 PROPOSAL REQUIREMENTS – BEST VALUE (JAN 2014) has changed.
The PRODUCT SAMPLE TEST & EVALUATION METHODOLGY has changed FROM:
Accuracy (Dispersion) and Match Test.
Test Procedure. A 10 shot group of product sample Ball rounds, a 10-shot group of product sample Tracer rounds, and a 10 shot group of M33 rounds will be fired. A physical target, acoustic sensors, or radar will measure and record the location of each shot at 1000 meters. The mean radius and center of impact of each group will be measured. The horizontal and vertical distances between the centers of impact of the product sample Ball group and M33 group will be measured. The horizontal and vertical distances between the centers of impact of the product sample Tracer group and M33 group will be measured. This procedure will continue until five product sample Ball groups, five product sample Tracer groups, and five M33 groups are fired.
Pass Criteria. The average of the mean radii of product sample Ball groups shall not exceed the average of the mean radii of M33 groups. The average of the mean radii of product sample Tracer groups shall not exceed the average of the mean radii of M33 groups. The average distance between centers of impact of product sample Ball groups and M33 groups shall not exceed 1.5 meters horizontal and 1.5 meters vertical. The average distance between centers of impact of product sample Tracer groups and M33 groups shall not exceed 1.5 meters horizontal and 1.5 meters vertical.
TO:
Accuracy (Dispersion) Test.
Test Procedure. A 10 shot group of product sample ball rounds and a 10-shot group of product sample tracer rounds shall be fired. A physical target, acoustic sensors, or radar will measure and record the location of each shot at 1000 meters. The mean radius and center of impact of each group will be measured. This procedure will continue until ten product sample ball groups and ten product sample tracer groups are fired Test Criteria. The average of the mean radii of product sample ball groups and tracer groups shall not exceed 17 in. The average distance between centers of impact of product sample Ball groups and product sample Tracer groups shall not exceed 1.5 meters horizontal and
1.5 meters vertical.
Product samples will be evaluated based on how well they conform to the test criteria outlined above.