Sheet1
| RFP # | M6740018Q0079 | |||
| Title | A/V SUSTAINMENT AND MAINTENANCE FOR EOC, BEOC AND CONFERENCE ROOM, MARINE CORPS INSTALLATION PACIFIC, FOSTER AND SCHWAB OKINAWA JAPAN. | |||
| Question | ||||
| No. | Reference (Specifications / Drawings) | Question | Answer | |
| 1 | Page 4-7 Solicitation M6740018Q0079.pdf | With reference to CLIN 0002, 0005, 0008 (ON CALL CORRECTIVE MAINTENANCE) Firm-Fixed-Price: Is it correct to assume that Re-Programming of AMX, Crestron, or Extron Controllers might be required as part of the On-Call Corrective Maintenance? | Yes, contractor will need to have the ability to troubleshoot and re-program AMX, Crestron and Extron controllers as a part of the On Call Corrective Maintenance requirement. | |
| 2 | Would it be a requirement to reprogram AMX, Crestron, and Extron Controller? | Yes, the controller is a function of the system. Contractor will be required to troubleshoot, isolate faults and re-program the controller. | ||
| 3 | ||||
| 4 | ||||
| 5 | ||||
| 6 | ||||
| 7 |