Attachment_1USMC_Window_Wrap_Graphic_Guide.pdf

PDF 744 KB Posted

Attached to
Storefront Glass Graphics Federal contract opportunity
Solicitation number
M00263-16-R-1004
Issued by
United States Marine Corps

About this file

Scalable Graphic

View the file

Other files for this federal contract opportunity

Other files attached to Storefront Glass Graphics, newest first.
File Type Posted
M00263-16-R-1004-0001.docx DOCX document
USMC_Window_Wrap_Graphics_Final.eps EPS file
Questions_and_Answers_for_Strorefont_Graphics_Solicitation.docx DOCX document
SSP_Attachment_3_-_Past_Performance_Questionnaire.doc DOC document
M00263-16-R-1004.docx DOCX document
Attachment_1_con't_USMC_Window_Wrap_Graphics_Final.pdf PDF
Attachment_2_PERFORATED_FILM_ROSTER.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

“Top Red Rule” always aligns to the top of door within the door frame.

MARINES and MARINES The Few. The Proud.® logos Base-Align on the word MARINES, becoming the Vertical Center-Point within the band as well.

LARGE EGA Center-Point is the Eagles NECK where it comes to a point.

MARINES The Few. The Proud.® logo is center in panel based on the left side of the “I” in the word MARINES. The period and registration (.®) hang and are not to be considered when centering.

If adjusting Blue Band and Red Rule to fill or fit to a particular depth, i.e., edge of window divider, ALWAYS keep logos and EGA at original size and re-center within new depth. Only Enlarge Blue Band.

Red Rule remains original size and is only moved to fit new space.

Whenever possible, Bookend the Door with Large EGAs on both sides and then alternate with MARINES The Few. The Proud.® logo for remaining panels.

When Double Doors are involved, duplicate EGA and Marines Lockup logo and if possible, Bookend the Door with Large EGAs on both sides and then alternate with MARINES The Few. The Proud.® logo for remaining panels.

If windows are full frame from top to bottom, i.e., no horizontal dividers, artwork should be used as provided.

The depth of the blue band including the Red Rules is 50.5” at actual size.

When not possible to Bookend the Door with Large EGAs on both sides alway place Large EGA in panel next to door and then alternate with MARINES The Few. The Proud. logo for remaining panels.

PANTONE Colors CMYK matches:

BLUE = 289 or C=100, M=64, Y=0, K=60

RED = 187 or C=0, M=100, Y=79, K=20

BLACK = BLACK C or C=66, M=64, Y=68, K=68

34” wide

26.5” wide

EGA

29.5” high

PROVIDED ARTWORK IS SET UP TO A 1/2” = 1” SCALE (FINAL OUTPUT 200%),

MEASUREMENTS BELOW REPRESENT GRAPHIC ELEMENTS AT ACTUAL SIZE.

horizontal center line

UNITED STATES MARINE CORPS

RECRUITING STATION WINDOW WRAP GUIDELINES

BELOW ARE OPTIONS FOR POSSIBLE WINDOW AND DOOR CONFIGURATIONS.

ALWAYS KEEP RED RULES, LOGOS AND EGAs AT SIZE PROVIDED AND CENTERED WITHIN BAND.

BLUE BAND CAN BE INCREASED IN DEPTH AND RED RULES REPOSITIONED IF NECESSARY.

Blue Band depth

Increased Red Rule remains original size

Blue Band depth

Decreased

Blue Band and Red Rule depth as provided

50.5”

Red Rules 2.5” high.

Always keep Red Rule at original size if extending Blue Band depth to fit a particular depth.

Red Rules and Blue Band combined 50.5” high

EXAMPLES OF NONCOMPLIANT

TREATMENTS ON NEXT PAGE.

“Top Red Rule” IS NOT aligned to the top of door within the door frame.

MARINES and MARINES The Few. The Proud.® logos ARE NOT aligned properly.

Large EGA IS NOT centered properly.

MARINES The Few. The Proud.® logo IS NOT centered in panel based on the left side of the “I” in the word MARINES.

DO NOT INCREASE the size of the logos or EGAs to fill space. These elements should be kept at original sizes.

RED RULE IS NOT ALIGNED PROPERLY as it should.

Align flush to any divider/mullion/facade, avoiding any small void/black area that creates a tanget.

This Blue Band should be increased to fill depth.

DOOR IS NOT bookended with Large EGAs on both sides.

LOGO ON DOOR IS NOT DUPLICATED.

DO NOT ARBITRARILARY increase the size of the Red Rules and Blue Band. Artwork should be used as provided, unless there are obstacles such as a divider/mullion/facade to work around. The depth of the Blue Band including the Red Rules is 50.5” at actual size.

RED RULE ON WRONG SIDE OF DIVIDER. When increasing the depth of the Red Rules and Blue Band, always keep bottom edge aligned with the divider/mullion/facade.

TOP RED RULE is not aligned with inside frame of door.

DO NOT increase the Red Rule in size/thickness when adjusting for new depth.

ONLY increase the Blue Band.

34” wide

26.5” wide

EGA

29.5” high

PROVIDED ARTWORK IS SET UP TO A 1/2” = 1” SCALE (FINAL OUTPUT 200%),

MEASUREMENTS BELOW REPRESENT GRAPHIC ELEMENTS AT ACTUAL SIZE.

horizontal center line

UNITED STATES MARINE CORPS

RECRUITING STATION WINDOW WRAP GUIDELINES

BELOW ARE EXAMPLES OF NONCOMPLIANT WINDOW TREATMENTS.

Blue Band depth

Increased but not aligned within frame properly

Band depth adjusted but not aligned properly

Proper alignment

Blue Band depth should not be increased arbitrarilary

Proper alignment

Proper alignment

Red Rules 2.5” high.

Always keep Red Rule at original size if extending Blue Band depth to fit a particular depth.

Red Rules and Blue Band combined 50.5” high

File details come from the government source that posted it. Updated .