This technical drawing package details the design of a wall-mounted hydraulic power unit for use at Kachess Dam outlet works. Key specifications include a 1/2 horsepower motor, 5-gallon reservoir, pressure gauge, filter, solenoid valves, and manifold fittings for 1/4-inch hydraulic tubing. Product coatings and anchoring requirements are defined. The design is proprietary to Hydro Gate Corporation.
The related federal contract opportunity is a solicitation from the Department of the Interior Bureau of Reclamation seeking offers for a plunger valve assembly to support modifications at Kachess Dam outlet works. No other salient details are provided in the opportunity description.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 33-D-61608_-_FRP_Bypass_Pipe_-_Contract_2.pdf | ||
| Sol_140R1723Q0069.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
A
D (22 X 34)
33-D-4870
I
- _oy I
16 -_-ij B · . I I o I I . - I I
- : �- Y' o.: I j
• r')
- I I
6-0
For indicator, see Detail E
-<1a ______ ___JJi ___ _
To 20" Slide gate
--l To 18" Butterfly valve
"�-.. B
CLOSE
OPEN
B
B
- I
,_�o�
--4�-------i_ .I I Detail
- ,.,., I
- -B -->,
- :�- I I
•V-
-- 0 o-:� �ri
�_:-�n _o
7-0
3-3 n_VI
.. . Q, ------------
�-�_:1fl 1-
-_ci_ --
B
V
- - . -_ci_ -
- - 0
- - . -_ci_ --_
() . • - 0
- I)
VIEW A-A
(INDICATOR NOT SHOWN)
Symmetrical about CL
:_o_-- - - - _ _
Bend pipe to suit, see Note C -------
VIEW C-C
TYPICAL
_v - - _ci - _-
._ -_o_ · _ '
- - • • I I - I
0 I_ . - o · l
I - o-_ - _-o-_ - 9 o- -o-_
_o - 1/1 •-r,,i
I - •
.f - - . 0 " - • 0 • -- • ____,. - - ::...___,a. i> - . . .. - . �- _:_i._-1-1111---. -
-----=-..:._o .
c,1
I
-- I o- - -• • 0 • -
Bend pipe to suit, see Note C ---
VIEW H-H (4868)
_J
B
B
SECTIONAL ELEVATION
18" Butterfly valve
-_ci _ -
B
To hydraulic } power unit
- . . - .o· . _- - -• -
- . -o
CLOSE
18" Butterfly valve cylinder
-_ci_ -- -ar------1
VIEW B-B
(INDICATOR NOT SHOWN}
B
VIEW J-J
B
SECTION K-K
V I • I/:) I 1 ' -
18" Butterfly valve cylinder ----
B
B
VIEW D-D
VIEW L-L
TYPICAL
L yr- ---:ly L
GI>-
.... , """a ,-
"t " I
,,I� I �
" I
DETAIL E
INDICATOR FOR 20" SLIDE GATE
Indicator guide l---oimension to be determined in field
VIEW G-G
DETAIL F TYPICAL TWO PLACES ON SLIDE GA TE
(LIMIT SWITCH NOT SHOWN)
NOTES
A. Externally threaded expansion anchor bolts shall be equal to Federal Specification FF-S-325 Interim Amendment 3, Group II, Type 4, Class 1.
B. Bends shall be made carefully if needed to avoid flattening of the tubing or pipe.
C. Nameplates shall be made in accordance with standard nameplate Dwg. 40-0-6234. See specifications.
D. Anchor bolt holes in concrete for hydraulic cylinder supports shall be core drilled.
1-22-96
D.-R. A.
MINOR REVISIONS
ALWAYS THINK SAFETY
UNITED STATES
DEPARTMENT OF THE INTERIOR
BUREAU OF RECLAMATION
YAKIMA PROJECT - WASHINGTON
KACHESS DAM
OUTLET WORKS MODIFICATIONS
HYDRAULIC CONTROLS FOR 20" SLIDE GATE
AND BUTTERFLY VALVE
ASSEMBLY
KR SMITH
DESIGNED ______________________________________________ _
KR SMITH TECHNICAL APPROVAL
DRAWN ________ _
R ARRINGTON --------------------------------
R ARRINGTON D M DRAKE
CHECKED •.•••••••..••••••..•••••...•••••...•.••••.••..•• APPROVED .••••..••••••..•••••••..••••••..•••••...•..••••••..••••••..••••.
AUTOCAD REL. 12.0
DENVER
f
COLORADO DECEMBER 7
f
=-ACAD SHEET 3 OF 7
MANAGER, HYDRAUUC EQUIPMENT GROUP
Tue 1/30/96 10:00
33-D-4870
D
C
B
A
FOR OFFICIAL USE ONLY 11-46
I SIDE VIEW F WALL SURFACE MOTOR CONNECTION
+ , f r DRECTIONAL CONTROL A v W PRESSURE SWITCH ~ SOLENOID VALVE . A- 56LENOD VALVE1 CONNECTION3/4 HP MOTOR- r-n, 1 , ~
5 GALLON L_-11 C.(Esl 14 1 -r PRESSURE SWITCH CONNECTION '-- RESERVOIR flm][~E FLOW CONTROL -- PRESSURE RELIEF VALVE
FILLER Fl SOLENOID -·*-21/2 * (OPPOSITE SIDE) ~~ ~@ C
24 5/8 * I - 1 SGHT -*rn· D TE 11- t16 1 LEVEL -4-Li -
GAUGE - -· - RETURN LINE RESERVOIR DRAIN -1
FLTER 98=Db b (OPPOSITE SIDE} ~
UPPER -
ANCHOR-~~
fr 6 - 1/2 DIA. X 7 LONG =-UE' 1 \
- -/ SST. EXPANSION ANCHORS
I 11/4 W/SIL. BRZ. HEX NUTS
A A PRESSURE GAUGE-
-*-- WALL MOUNTED RESERVOIR DRAIN 153/4 POWER UNIT TOP VIEW
SUPPORT BRACKET
NOTES WALL SURFACE -~ WALL MOUNTED POWER
1. DIMENSIONS.SHOWN IN INCHES. 9 UNIT SUPPORT BRACKET
11/2
2. REPRESENTS HYDRAUUC TUBNG NOT BY HYDRO GATE.
39 TO 4 15 - 3. SWAGE TYPE FITTNGS PROVIDED AT VALVE MANIFOLD FOR 1 /20 -rTOC El-EV. DIAMETER HYDRAUUC TUBING,
2268.0 -- -*- 1/4, BRACKET MATERIAL AT ANCHORS
m. 4. l.INIT IS SHIPPED ASSEMBLED, AT A MNIMUM, THE UPPER EXPANSION
ANCHORS ARE TO BE LOCATED AND SET PRIOR TO POWER UNIT SUPPORT 4 271 /4 * I.
BRACKET NSTALLATION. THIS WILL ALLOW INSTALLATION OF POWER UNIT
ASSEMBLY WITHOUT DISASSEMBLY, WHILE SUM'ORTNG POWER UNIT WEIGHTFRONT VEW SIDE VIEWDURING COMPLETION OF THE SETTING OF EXPANSION ANCHORS.
* SDE VIEW 5. COATING PER DRAWING H0389500.
6. REFER TO DRAWING 1-10389300 FOR HYDRAUUC SCI-EMATIC AND PARTS UST.
This is a proprietory design of Hydro Gate Corp. The design, WALL MOUNTED HYDRAULIC POWER UNIT data and information relating thereto is not to be used, FOR BYPASS SLIDE GATE AND BUTTERFLY VALVEdisseminated, or reproduced in whole or in port without
LOCATED AT KACIHESS DAM OUTLET WORKSthe written consent of Hydro Gote Corp.
ONE REQUIREDill' 1 1 'g REVISED DRAWN BY CUSTOMER NO. SALES ORDER
71:/12/."rflirr MAIA 96 02-03 96-0389 DO NOT SCALE Lgdbil CHECKED BY DATE DRAWING NO.
April 2013 DRAWING HYDRO GATE Corporation FOR OFFICIAL USE ONLY 11/22/96 H0389003 Kacil~,ss Darn Revision No. 25
| 33-D-4868-RD-1 |
| 33-D-4869-RD-2 |
| 33-D-4910-RD-2 |
| 33-D-4870-RD-3 |
| 33-D-4871-RD-4 |
| 33-D-4872-RD-5 |
| 33-D-4873-RD-6 |
| 33-D-4874-RD-7 |
| Wall Mounted Hydraulic Power Unit-Hydro Gate |
File details come from the government source that posted it. Updated .