33-D-61608_-_FRP_Bypass_Pipe_-_Contract_2.pdf

PDF 851 KB Posted

Attached to
Plunger Valve Assembly Federal contract opportunity
Solicitation number
140R1723Q0069
Issued by
Department of the Interior Bureau of Reclamation

About this file

This document is a set of construction plans for a FRP bypass pipe at the Kachess Dam project. The plans show the layout of the 20-inch FRP piping, including details of two combined bends, flanged and grooved couplings, and the connection to a government-furnished plunger valve assembly. Notes indicate the contractor may submit alternatives to Combined Bend 2, and that 10 feet of downstream piping should have ultraviolet inhibitor. The related solicitation is for the plunger valve assembly to be furnished by the Department of the Interior Bureau of Reclamation for this FRP bypass pipe project at Kachess Dam.

View the file

Other files for this federal contract opportunity

Other files attached to Plunger Valve Assembly, newest first.
File Type Posted
Sol_140R1723Q0069.pdf PDF
Kachess_Bypass_Existing_Hydraulic_System_packet__revised.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Plane of bend

Top Match Point

COMBINED BEND 2

PI 20" FRP pipe 1 cut miter bend, Δ=3°52'1"

17°56'2"

Field vertical centerline

Field vertical centerline

2" = 1'

17°56'2"

3°52'1"

20" FRP flange suitable for connection to AWWA Class D flange

18" Sch. 10 steel pipe

15'-0"

CL AWWA Class D flanged connection to FRP piping

20" FRP

pipe

PI Combined bend 2, see detail

2'-2"

6'-01 8"

280'-11"

18" x 20" Flanged FRP eccentric reducer

20" FRP

pipe

CL AWWA Class D flanged connection

18" FRP flange suitable for connection to AWWA Class D flange

124'-41 2"

3.

Slope = 0.002

Slope = 0.002

2'-35 8"

1'-9"

7'-0"

CL Grooved-end coupling

CL Grooved-end coupling

3'-6 1 16 "

1'-7"

Government furnished plunger valve assembly

PI Combined bend 1, see detail

PI 3-Cut miter bend, Δ = 30°

1/2" = 1'

SECTION CC

1'-9" 1'-9"

CL Grooved-end coupling

11 1 16"

CL AWWA Class D flanged connection

28.81°

18" Sch. 10 steel pipe

15'-0"

CL AWWA Class D flanged connection to FRP piping

18" x 20" FRP eccentric reducer

CL AWWA Class D flanged connection

18" FRP flange suitable for connection to AWWA Class D flange

283'-1"

6'-0"

124'-41 2"

20" FRP flange suitable for connection to AWWA Class D flange

PI Combined bend 2, see detail

PLAN

C

1.19°

Government furnished plunger valve assembly

20" FRP pipe

C

21.47°

7'-0"

PI Combined bend 1, see Detail

3'-07 8"

11 1 16 "CL AWWA Class D flanged connection

PI 30° 3-cut miter bend

2'-35 8"

1'-9" 1'-9"

1'-9" CL Grooved-end coupling

2" = 1'

COMBINED BEND 1

33°38'38"

39°13'8"

6 Equal divisions @ 5° 53' 43"

35°22'16"

Developed angle @ 35° 22' 16"Plane of bend

Plane of bendTop Match Point

Top Match Point

Note: 18" Sch. 10, 45° welding elbow cut to 35° 22' 16" may be substituted for the miter bend

Field vertical centerline

Field vertical centerline

2" = 1'

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 2-

LA

S T

S A V

ED

B Y

LA

D

A M

S

YA

K

IM

A P

R O

JE

C T

K

IT

TI

TA

S D

IV

IS

IO

N

K A C H

ES

S D

A M

K A C H

ES

S D

A M

FRP BYPASS PIPE

PLAN, SECTION, AND

DETAILS

DENVER, CO

33-D-61608

2022-12-13

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

Lucas Adams

Lucas Adams

Rex Schlosser

Adams, Lucas P.E.

DiUbaldo, Meghan E P.E.

Supervisor, Mechanical Piping and Systems

1. Provide isolating kit for 18-inch AWWA Class D flanged joint to Government furnished plunger valve assembly.

2. Provide downstream 10-feet of FRP piping with suitable ultraviolet inhibitor for exposed service.

3. Contractor may submit alternatives to Combined bend 2 subject to Government approval.

4. See (61607) for General Notes.

NOTES

R el ea se d

33-D-61608 ShtNo: 3

File details come from the government source that posted it. Updated .