J.1.2 Record Drawings (2019).pdf
PDF 845 KB Posted
- Attached to
- FS/RMRS AC Replacement Federal contract opportunity
- Solicitation number
- 1240LT24Q0026
- Issued by
- Department of Agriculture Forest Service
About this file
This record drawing and related federal contract opportunity document provide specifications for replacing the Computer Room Air Conditioning (CRAC) unit and condensing unit at the Forest Service's Fire Lab in Missoula, Montana. The scope of work includes removing the existing CRAC and condensing units, installing a new CRAC unit with integrated humidifier and water supply, and completing all associated mechanical, plumbing, electrical, controls and roof work. Interested contractors should respond to Solicitation Number 1240LT24Q0026 by the response date. The NAICS code is 238220 and the small business size standard is $19 million. The contractor will provide all labor, materials, equipment and transportation to complete the air conditioning replacement and ensure a fully functional and usable system.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions-Answers 002.pdf | ||
| Questions-Answers 001.pdf | ||
| J.1.4 Experience Questionaire.doc | DOC document | |
| Solicitation 1240LT24Q0026 FS-RMRS AC Replacement.pdf | ||
| J.1.3 Pictures.pdf | ||
| J.1.1 SOI.pdf | ||
| J.1.5 Wage Determination - MT20240063 01-12-2024.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I S S
E F
O R
P
LAN
O EN
G
IN
E E R
ON
T
M
AN
A
LICENSE
D
GARTH L.
STEVENS
No. 11492 PE
J
J
J
J
J
J J
M L M L M L M L M L M L M L M L M LJ
L M
J
J
J
J M
5 4 3
E
F
G
H
J
GFI
GFI
RESTROOM
/ SHWR
102 C (E)
CORRIDOR
101 C
SERVER
ROOM
106 C
OPEN
OFFICE
108 C
CL1-3
CL1-1
CL1-4
BL3-67
BL3-67
BL3-69
CL1
(E)
MECH /
STOR
103C
RESTROOM
/ SHWR
102 C
PANEL CL2
E2.3
CL1-1 CL1-2
CL1-2
CL1-5
CL1-5
CL1-4
CL1-6CL1-6CL1-7
E2.6
CL1-3
CRAC-1
EWH-2
EWH-1
CL1-41,43
CL1-37,39
EXISTING TELEPHONE
PATCH PANEL
BH1-44,46,48
E9.2
TO MAIN PANEL
GENERAL ELECTRICAL NOTES
A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE
WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION
OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT
THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS,
WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED
IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING
OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.
C. ANYWHERE EXISTING ELECTRICAL PANELBOARD IS BEING REPLACED WITH
NEW PANELBOARD, CONTRACTOR SHALL SUBMIT DIMENSIONED ELEVATION
VIEW SHOWING NEW PANEL ENCLOSURE AND GUTTER(S) AS REQUIRED TO
ACCOMMODATE EXISTING CONDUITS/WIRES FEEDING AND BEING FED FROM
THE PANEL.
SERVER
ROOM
106 C
PS-A PS-A
PS-A
UPS 6UPS 5UPS 6
UPS 7
UPS
UPS
UPS
ENCLOSED
CABINET
ENCLOSED
CABINET
ENCLOSED
CABINET
ENCLOSED
CABINET
UPS 8TABLE RACK
CL2
CL2-45
CL2-47 CL2-49
CL2-39 CL2-37 CL2-35 CL2-33 CL2-31 CL2-29 CL2-27 CL2-25
CL2-21
CL2-23
CL2-41
CL2-38,40
CL2-17
CL2-34,36
CL2-15
CL2-30,32
CL2-13
CL2-26,28
CL2-11
CL2-22,24
CL2-9
CL2-18,20
CL2-7
CL2-14,16
CL2-5
CL2-10,12
CL2-3
CL2-6,8
CL2-1
CL2-2,4
TYP
TYP
CL2-43 CL2-42,44
CL2-19
E9.2
T CL1-24
5 4 3
E
F
G
H
J
EF-3
RTU-1
CU-1
BH1-50,52,54
CL1-14,16,18
CL1-40
CL1-38
A
B
C
KEY NOTES:#
PROJECT NO.
CHECKED
DRAWN
DESIGNER
DATE ARCHIVE NO.
DRAWING SHEET NO.
SHEET OF
REVISION
PROJECT NAME
DATEREVISION / ISSUENO.
REVISION DATE
REVISION DATE
REVISION DATE
United States Department of Agriculture Forest Service
DRAWING TITLE
1055 Mount Ave., Missoula, MT 59801
Phone: (406) 542-8880
FIRE LAB AIR
QUALITY &
ELECTRONIC LAB
5/
/2
2:
:3
P
M
E2.3
05.23.19
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
0% S
U B
M
IT
T A
L
LEVEL 1 ENLARGED
POWER PLAN
18075.00
Checker
TJW
GLS
1/4" = 1'-0"13 LEVEL 1 ENLARGED POWER AREA C
1. COORDINATE WITH GENERAL CONTRACTOR TO REMOVE SUFFICIENT WALL
COVERING TO ALLOW FOR DEMOLITION OF EXISTING RECESSED PANEL CA
AND REPLACE IT WITH NEW PANEL CL1. RECONNECT ALL IN USE BRANCH
CIRCUIT LOADS TO NEW BREAKERS (SEE PANEL SCHEDULE, SHEETS E9.7).
WHILE WALL IS APART AND PANEL IS ACCESSIBLE, PROVIDE (6) 1" CONDUITS
TO ACCESSIBLE CEILING ABOVE.
2. MOUNT POWER RECEPTACLES ON SIDE OF LADDER CABLE TRAY.
3. DIRECT WIRE LARGE UPS USING SO CORD FROM JUNCTION BOX ON SIDE OF
CABLE TRAY.
4. PROVIDE A #3/0 BARE COPPER GROUND WIRE FROM THE GROUND BUS IN
PANEL BL1 AND INSTALL A GROUND BUS IN THE DATA ROOM. ALSO, BOND
THIS GROUND TO THE LADDER CABLE TRAY.
5. NEW OPEN DATA RACK (SEE SHEET E2.6)
6. ALL CABINET RACKS AND UPS UNITS ARE BEING RELOCATED FROM EXISTING
DATA ROOM BY OWNERS I.T. PERSONNEL.
7. PROVIDE 12" WIDE x 1.5" DEEP ALUMINUM LADDER RACK PROVIDE T- AND L-
FITTINGS AS SHOWN AND PROVIDE 90-DEGREE DROP-FITTING AT LOCATION
WHERE EXISTING NOTCHED FLOOR MEETS THE WALL. VERTICAL LADDER
RACK WILL NOT BE REQUIRED. MOUNT IN ACCORDANCE WITH DETAIL 5 ON
SHEET E9.2. ENSURE THAT CABLE TRAY IS GROUNDED THROUGHOUT ITS
FULL LENGTH.
8. PROVIDE RED, MUSHROOM HEAD, EMERGENCY PUSHBUTTON WITH CLEAR
SAFETY COVER ON WALL NEAR DOOR AT 66" AFF. TIE TO SHUNT TRIP MAIN
BREAKER IN PANEL CL2 AND PROVIDE SIGN "DATA ROOM EMERGENCY SHUT-
OFF".
9. SEE DETAIL 15 FOR ADDITIONAL WORK IN THIS AREA.
10. RELOCATE EXISTING TEMPERATURE ALARM FROM EXISTING DATA ROOM TO
NEW DATA ROOM.
11. ROUTE FEED FROM PANEL BL1 TO PANEL CL2 SURFACE MOUNTED TO GYP.
BOARD CEILING IN ENTRY. PROVIDE APPROPRIATELY SIZED PULL BOX IN THE
NEW ELECTRICAL ROOM. ROUTE CONDUIT ON THE WALL/CEILING OF THE
ELECTRICAL ROOM AND ABOVE THE T-GRID CEILING IN OPEN OFFICE 108C.
1/2" = 1'-0" E2.315 LEVEL 1 ENLARGED POWER AREA C - Callout 1
NORTH
0'4' 2' 4' 8' NORTH
0'2' 1' 2' 4'
1/8" = 1'-0"7 LEVEL 1 ENLARGED POWER AREA C ROOF PLAN
D. FOR ALL DEVICES SHOWN, THE INTENT IS THAT THEY BE CONCEALED IN THE
WALLS OR CEILING. FISH WITH MC CABLE IN ANY EXISTING WALLS AS
REQUIRED. SURFACE MOUNT CONDUIT IS ONLY ALLOWED WHERE
SPECIFICALLY CALLED OUT.
| M3.3 - Computer Room Mechanical (2019) |
| P3.2 - Computer Room Plumbing (2019) |
| E2.3 - Computer Room Electrical (2019) |
File details come from the government source that posted it. Updated .