J-11 Dry Dock Eval Form.docx

DOCX document 39 KB Posted

Attached to
USNS APACHE (T-ATF 172) Regular Overhaul/Dry-Docking Federal contract opportunity
Solicitation number
N3220521R6500
Issued by
Department of the Navy Military Sealift Command

About this file

This document contains a drydock evaluation form and details for a federal solicitation. The drydock evaluation form provides ship and drydock characteristics for the USNS APACHE (T-ATF 172) including dimensions, draft, displacement, and blocking requirements. Minimum services needed for the drydock include electrical power, sewage connections, fire main, auxiliary seawater, fresh water, compressed air, and shore steam. Safety response plans must be available for firefighting, flooding, earthquakes, typhoons, and other emergencies.

The related federal contract opportunity is solicitation number N3220521R6500 issued by the Department of the Navy Military Sealift Command for the regular overhaul and dry-docking of the USNS APACHE. Offerors must meet the requirements in the solicitation, attachments, and exhibits to be considered for this work.

View the file

Other files for this federal contract opportunity

Other files attached to USNS APACHE (T-ATF 172) Regular Overhaul/Dry-Docking, newest first.
File Type Posted
N3220521R6500-0004.docx DOCX document
J-10 Rev3 - Interport Differential.docx DOCX document
N3220521R6500-0003.docx DOCX document
J-10 Rev2 - Interport Differential.docx DOCX document
N3220521R6500-0002.docx DOCX document
RFC 2.docx DOCX document
N3220521R6500-0001.docx DOCX document
J-10 Rev1 - Interport Differential.docx DOCX document
RFC 1.docx DOCX document
J_A APACHE ROH FY21_Redacted.pdf PDF
J-10 Interport Differential.docx DOCX document
J-2 Category A Items.xlsx XLSX spreadsheet
RFP N3220521R6500.docx DOCX document
J-9 Disclosure of Lobbying Activities SF-LLL.docx DOCX document
J-3 Category B Item.xlsx XLSX spreadsheet
J-8 Request for Spec Clarification.docx DOCX document
J-7 MSC Ship Repair Facility Survey.docx DOCX document
J-14 Technical Data Non-Disclosure.docx DOCX document
J-12 Past Performance Data.docx DOCX document
Exhibit A - CDRLs.pdf PDF
J-13 Past Performance Questionnaire.docx DOCX document
J-4 GFM List.pdf PDF
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N3220520R6501 N32205-21-R-6500

MSC DRYDOCK EVALUATION FORM

Ship name:
USNS APACHE
Hull No:
T-ATF 172

PART A (to be completed by MSC)

PART B (to be completed by ALL shipyards)

Drydock Certification / Classification Info

Shipyard name

Drydock No.

Drydock Type Graving |_| Floating |_| Marine Railway |_|

Certified? Yes |_| No |_|

Certifying / Classifying Agency

Certificate No.

Date of expiration

Ship Characteristics
English measure
Metric measure

Provide date in English and Metric Units:

Length, overall
226
ft -
0
In
0.0 m

Drydock Characteristics

Breadth, molded
42
ft -
0
In
0.0 m

Length, overall ft-in m

Draft, light load line
N/A
ft -
0
In
0.0 m

Breadth ft-in m

Gross Tonnage (U. S.)
N/A
Tons

MT

Displacement, Full Load
2260
LT

MT

Maximum drydock lift capability

LT

MT

Minimum Displacement/Draft

Displacement
2260
LT

MT

Draft – forward
15
ft -
1
In
m

Maximum entry draft rating:

LT

MT

Draft – aft
15
ft -
1
In
m

Max stern trim for graving dock

ft -
0
In
m

Water depths around dock ft-in m area and approaches, tidal conditions, Anticipated Arrival Draft and any unusual conditions for entering/

Draft - forward
14
ft -
0
In
m

leaving the drydock.

Draft - aft
14
ft -
0
In
m

Depth Over Floor ft-in m

Positioning Clearances

Depth Over Blocks ft-in m

Bottom: keel to drydock floor
5
ft -
0
In
m

Depth Over Sill ft-in m

Side: hull to drydock wall
5
ft -
0
In
m

Depth Over KEEL ft-in m

Loading Pressures

Max block loading
23.79
LTons Per square ft.
per sq mtr

Note: All blocks to be positioned under longitudinal strength members and transverse bulkheads.

MSC DRYDOCK EVALUATION FORM (cont’d)

PART A (to be completed by MSC)

PART B (to be completed by ALL shipyards)

Max Block Loading Capability

Blocking Requirements

Block Capability

LT/ft2

LT/m2

Construction
Hard Wood

Keel & Side Block Information

Cap material
Soft Wood

Construction

Cap thickness (min)
2

Cap Material

Side blocks (e.g., shaped, wedged, etc.)
Shaped

Cap Thickness in cm

Block Age

Hardwood: White Oak, California Laurel, Oregon Myrtle, Iron bark, Height ft-in m

Blue Gum, American Rock Elm or Preserved Red Oak.

Width ft-in m

Softwood: Douglas Fir, Tamarack, Long Leaf Pine or Hemlock

Length ft-in m

Minimum Required Services

Minimum Available Services

Electrical power

Electrical power

AC volts
450
VAC

AC volts

number of phases
3

number of phases

VAC

amperage (total)
400
Amps

amperage (total)

frequency
60
Hz

frequency amps

number of lines
1

number of lines

Hz

Ground connections

Ground connections

number
1

number

cable size, each
500,000
cir mils

cable size, each cir mils

Sewage connections

Sewage connections

number
1

number

pipe size
4
inch ips

pipe size

capacity
2000
gals per day

capacity inch ips cm gal/day ltr/day

Fire Main

Fire Main

number of connections
2

number of connections

connection size
2- 1/2
inch ips

connection size

pressure
100
Psig

pressure inch ips cm

capacity
1,000
gals per min

capacity psig kg/m2 gpm ltr/min

Aux Seawater

Aux Seawater

pressure
100
Psig

pressure

capacity
520
gals per min

capacity psig kg/m2 gpm ltr/min

Fresh Water

Fresh Water

pressure
60
Psig

pressure

capacity
100
gals per min

capacity psig kg/m2 gpm ltr/min

MSC DRYDOCK EVALUATION FORM (cont’d)

Compressed Air

Compressed Air

pressure
125
Psig

pressure

capacity
300
cu ft per min

capacity psig kg/m2 cfm ltr/min

Shore Steam

Shore Steam

pressure
NA
psig

pressure

capacity
NA
lbs per hour

capacity psig kg/m2 lb/hr kg/hr

High Pressure Water Wash pressure
3,000
psig

High Pressure Water Wash pressure psig kg per sq cm

Safety Response Plans Required

Safety Response Plans Available (circle correct answer)

Firefighting
YesX
No|_|

Firefighting

Flooding (accidental)
YesX
No|_|
Flooding (accidental)
Yes
No
Earthquake
Yes|X|
No
Earthquake
Yes
No
Typhoon
Yes|X|
No
Typhoon
Yes
No

PART C (to be completed by Shipyard if drydock is not certified by IACS or under MIL STD 1625C)

Dockmaster info

Contractor name

Dockmaster name

Certifying Agency

Certificate No.

Years experience

Drydock Insurance Info

Is Drydock insured?
Yes |_|No |_|

Insurer

Policy No.

Amount Insured

Date of expiration

Attachment J – 11

ATTACHMENT J - 11

File details come from the government source that posted it. Updated .