CED 1R15-A PERSONAL LIFT.pdf
PDF 173 KB Posted
- Attached to
- Personal Lifts
- Solicitation number
- HQC00424Q0011
- Issued by
-
Defense Commissary Agency
About this file
This document outlines minimum acceptable standards for a personal lift to be used by the Defense Commissary Agency. Key specifications for the lift include a working height of at least 25 feet, a lift capacity of 350 pounds, non-marking solid tires, self-propulsion, auxiliary platform controls, maintenance-free batteries, motion and beacon lights, an automotive horn, and a safety harness. The lift must be Underwriters Laboratory listed and have at least a one-year warranty on parts, service, and labor. Standard electrical specifications are 120 volts and 60 Hertz for U.S. stores and 110 volts and 50 Hertz for stores in the Pacific Theater. The lift must include a minimum six-foot cord with a NEMA plug and have an operating voltage range of 110-120 volts or 208-230 volts. The contractor must provide contact information, installation and operating instructions, and a parts list at delivery and ensure continued parts support for five years beyond the projected life cycle of the equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pricing Spreadsheet HQC00422Q0010 Personal Lifts.xlsx | XLSX spreadsheet | |
| HQC00424Q0011 Combined Synopsis-Solicitation - Personal Lifts.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INITIATED
06/15/21
CED
RECEIVING
DEPARTMENT
Minimal Acceptable Standards
REVISION
xx/xx/xx
1R15-A Personal lift, one person PAGE 1 of 4
FY16r.05
1 Purpose of this Equipment: To provide stores with the capability to change lights, hang banners and perform minor clean up.
2 Federal Supply Class: 3930
3 General Operating Specifications:
3.1 Dimensions:
3.1.1 54 inches long, 32 inches wide, 78 inches high. Dimensional sizes, such as length, width, and height may vary no more than 3 inches in any direction.
3.2 Salient Characteristics that shall be provided:
3.2.1 Minimum working height of 25 feet.
3.2.2 Minimum lift capacity of 350 pounds.
3.2.3 Non-marking solid tires.
3.2.4 Self-propelled.
3.2.5 Auxiliary platform controls.
3.2.6 Maintenance free batteries.
3.2.7 Motion alarm.
3.2.8 Beacon light.
3.2.9 Automotive Horn.
3.2.10 Safety harness.
3.3 Industry Standards / Requirement(s):
3.3.1 Industry Standards: Underwriters Laboratory (UL) listed or approved equivalent. Conformité Européene (CE) is not acceptable for a standard.
3.3.2 Warranty period shall be for (1) year from date of delivery against defective material and workmanship and shall include parts, service and labor.
3.4 Information Technology Requirements: N / A
3.5 Color Requirement(s): N / A
INITIATED
06/15/21
CED
RECEIVING
DEPARTMENT
Minimal Acceptable Standards
REVISION
xx/xx/xx
1R15-A Personal lift, one person PAGE 2 of 4
FY16r.05
4 Electrical Requirements:
4.1 _____ Standard U.S.A. electrical specifications: 120 volts, 60 Hertz, 1 phase.
4.2 _____ Pacific Theater stores 110 volt / 50 HZ / 1 PH (Applies to these stores only: Atsugi, Misawa, Sagami, Sagamihara, Yokosuka, Yokota, Camp Zama, and Kanto Plains CDC. All other stores are standard U.S.A. 60 cycle voltages.)
4.3 Minimum 6 foot cord with a NEMA Standard plug, or a manufacturer’s equivalent to comply with the equipment plug in requirements.
4.4 NOTE: the operating range for 120 volts is 110 to 120 volts; the operating range for 220 volts is 208 to 230 volts.
5 Standard Contractor Requirements:
5.1 Information to be provided by the Contractor to the commissary at the time of delivery:
5.1.1 Point of Contact for Service
5.1.2 Installation and Operating Instructions
5.1.3 Parts List
5.2 Maintenance Sustainability Requirements: Continued parts support is required for the projected life cycle of the equipment plus 5 years.
6 Special Coordinating / Safety Instructions: N / A
| 1 Purpose of this Equipment: To provide stores with the capability to change lights, hang banners and perform minor clean up. |
| 3.3 Industry Standards / Requirement(s): |
| 3.5 Color Requirement(s): N / A |
| 4.1 _____ Standard U.S.A. electrical specifications: 120 volts, 60 Hertz, 1 phase. |
| 4.2 _____ Pacific Theater stores 110 volt / 50 HZ / 1 PH (Applies to these stores only: Atsugi, Misawa, Sagami, Sagamihara, Yokosuka, Yokota, Camp Zama, and Kanto Plains CDC. All other stores are standard U.S.A. 60 cycle voltages.) |
| 4.3 Minimum 6 foot cord with a NEMA Standard plug, or a manufacturer’s equivalent to comply with the equipment plug in requirements. |
| 4.4 NOTE: the operating range for 120 volts is 110 to 120 volts; the operating range for 220 volts is 208 to 230 volts. |
| 5 Standard Contractor Requirements: |
| 6 Special Coordinating / Safety Instructions: N / A |
File details come from the government source that posted it. Updated .