Attachment for Solicitation dated 4-23-18

View the file

Other files

File Type Posted
Award_Notice-QA707.pdf PDF
HC101318QA707.v0_4-23-18.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Testing Requirements and Circuit Parameters for Solicitation HC101318QA707

A. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL ADDRESSEES

IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,

PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE

IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).

ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT

NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES

TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE

UPDATED.

B. COMPLETION REPORT: FOR STATION DESIGNATED IN PARAGRAPH 2H AS

CCO/CMO, FOR THIS ACTION COMPLETION REPORTS WILL BE SUBMITTED IAW

DISAC 310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN 312-770-8627;

COML 618-220-8627. ALL OTHER CCO/CMO RESPONSIBILITIES REMAIN

WITH THE DESIGNATED CCO/CMO IAW DISAC 310-70-1, CHAPTER 8.

C. IMPLEMENTATION ASSISTANCE: FOR CIRCUIT INSTALLATION ASSISTANCE

WITH THE COMMERCIAL LEASED PATH, CONTACT

DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,

C614-692-0820

FOR DISN CORE / DEDICATED /

NIPRNET / SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE

IMPLEMENTATION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF A

CTIVATIONS TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVA

TIONS@MAIL.MIL, OR CALL DSN 770-8627; COML 618-220-8627.

D. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED

COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE

SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1

BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE

ON SUBMISSION IS AVAILABLE AT

HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON

"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION

PROCEDURES."

E. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY

SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING

DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE

DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS

1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032

OPTION 2, DSN 312-850-0032 OPTION 2.

TEST & ACCEPTANCE INSTRUCTIONS: CONUS ETHERNET

F. VENDOR WILL PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER

RFC-6815 OR ITU-T Y.1564. SPECIFICALLY, FRAME SIZES OF

64,128,256,512,1024,1280 AND 1518 BYTES MUST BE USED. THE

TEST MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE NUMBER

OF FRAMES DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER,

AND DUPLICATE FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE

SAME DATA RATE IN EACH DIRECTION. BURST TESTS MUST BE RUN TO

DETERMINE MINIMUM INTERVAL BETWEEN FRAMES THAT CAN BE

PROCESSED WITHOUT FRAME LOSS. A THROUGHPUT TEST IS REQUIRED

INDICATING THE FASTEST RATE AT WHICH TEST FRAMES CAN BE

TRANSMITTED WITHOUT FRAME LOSS. A SEPARATE THROUGHPUT TEST

MUST BE RUN WITH FRAMES ADDRESSED TO THE HARDWARE BROADCAST

ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST STREAM AND BE

EVENLY DISTRIBUTED THROUGHOUT THE TEST. A LATENCY TEST MUST

BE RUN WITH FRAMES ADDRESSED TO THE HARDWARE BROADCAST

ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST STREAM AND BE

EVENLY DISTRIBUTED THROUGHOUT THE TEST. A LATENCY TEST MUST

BE RUN FOR A PERIOD OF NO LESS THAN 120 SECONDS, AND REPEATED

NO LESS THAT 20 TIMES. THE TEST STREAM FOR THE LATENCY TEST

SHOULD BE RUN AT THE THROUGHPUT RATE FOR CORRESPONDING FRAME

SIZES FROM THE THROUGHPUT TEST. END TO END LATENCY WILL BE

CALCULATED AS THE AVERAGE OVER THE 20 TEST RUNS. FRAME LOSS

RATE TESTS SHOULD BE RUN AT THE FRAME RATE CORRESPONDING TO

THE MAXIMUM FRAME RATE, AND REDUCED BY 10% INTERVALS UNTIL

THERE ARE AT LEAST TWO CONSECUTIVE RUNS IN WHICH

NO FRAMES ARE LOST. THROUGHPUT TEST RESULTS: PASSING RATE

100% FOR ALL FRAME BYTE SIZES EXERCISED. FRAME LOSS RATE (%)

RESULTS: FRAME LOSS RATE LESS THAN 0.01% FOR ALL FRAME BYTE

SIZES EXERCISED. LATENCY WILL BE MEASURED WILL BE ACCORDING

TO THE FOLLOWING MAXIMUM TRANSMISSION DELAY FOR ANY CIRCUIT

UP TO 500 MILES AIR-MILES IN LENGTH SHALL BE NO

GREATER THAN 13MS ONE-WAY AND

ANY POINT-TO-POINT CIRCUIT LONGER THAN 500 AIR-MILES SHALL

BE NO GREATER THAN 50MS ONE WAY WITHIN THE 48 CONTINENTAL

STATES. ANY APS SWITCHOVER SHALL TAKE LESS THAN 50

MILLISECONDS.

G.END TO END TESTING WILL BE COMPLETED OVER A CONTINOUS 24

HOUR PERIOD WITH DOCUMENTATION PROVIDED TO THE GOVERNMENT.

H.CIRCUIT SPECIFICATIONS: MONTHLY AVAILABILITY RATE SHALL BE

99.5% OR BETTER FOR THIS REQUIREMENT.