Testing Requirements and Circuit Parameters for Solicitation HC101318QA707
A. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL ADDRESSEES
IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,
PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE
IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).
ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT
NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES
TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE
UPDATED.
B. COMPLETION REPORT: FOR STATION DESIGNATED IN PARAGRAPH 2H AS
CCO/CMO, FOR THIS ACTION COMPLETION REPORTS WILL BE SUBMITTED IAW
DISAC 310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN 312-770-8627;
COML 618-220-8627. ALL OTHER CCO/CMO RESPONSIBILITIES REMAIN
WITH THE DESIGNATED CCO/CMO IAW DISAC 310-70-1, CHAPTER 8.
C. IMPLEMENTATION ASSISTANCE: FOR CIRCUIT INSTALLATION ASSISTANCE
WITH THE COMMERCIAL LEASED PATH, CONTACT
DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,
C614-692-0820
FOR DISN CORE / DEDICATED /
NIPRNET / SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE
IMPLEMENTATION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF A
CTIVATIONS TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVA
TIONS@MAIL.MIL, OR CALL DSN 770-8627; COML 618-220-8627.
D. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
E. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY
SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING
DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE
DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS
1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032
OPTION 2, DSN 312-850-0032 OPTION 2.
TEST & ACCEPTANCE INSTRUCTIONS: CONUS ETHERNET
F. VENDOR WILL PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER
RFC-6815 OR ITU-T Y.1564. SPECIFICALLY, FRAME SIZES OF
64,128,256,512,1024,1280 AND 1518 BYTES MUST BE USED. THE
TEST MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE NUMBER
OF FRAMES DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER,
AND DUPLICATE FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE
SAME DATA RATE IN EACH DIRECTION. BURST TESTS MUST BE RUN TO
DETERMINE MINIMUM INTERVAL BETWEEN FRAMES THAT CAN BE
PROCESSED WITHOUT FRAME LOSS. A THROUGHPUT TEST IS REQUIRED
INDICATING THE FASTEST RATE AT WHICH TEST FRAMES CAN BE
TRANSMITTED WITHOUT FRAME LOSS. A SEPARATE THROUGHPUT TEST
MUST BE RUN WITH FRAMES ADDRESSED TO THE HARDWARE BROADCAST
ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST STREAM AND BE
EVENLY DISTRIBUTED THROUGHOUT THE TEST. A LATENCY TEST MUST
BE RUN WITH FRAMES ADDRESSED TO THE HARDWARE BROADCAST
ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST STREAM AND BE
EVENLY DISTRIBUTED THROUGHOUT THE TEST. A LATENCY TEST MUST
BE RUN FOR A PERIOD OF NO LESS THAN 120 SECONDS, AND REPEATED
NO LESS THAT 20 TIMES. THE TEST STREAM FOR THE LATENCY TEST
SHOULD BE RUN AT THE THROUGHPUT RATE FOR CORRESPONDING FRAME
SIZES FROM THE THROUGHPUT TEST. END TO END LATENCY WILL BE
CALCULATED AS THE AVERAGE OVER THE 20 TEST RUNS. FRAME LOSS
RATE TESTS SHOULD BE RUN AT THE FRAME RATE CORRESPONDING TO
THE MAXIMUM FRAME RATE, AND REDUCED BY 10% INTERVALS UNTIL
THERE ARE AT LEAST TWO CONSECUTIVE RUNS IN WHICH
NO FRAMES ARE LOST. THROUGHPUT TEST RESULTS: PASSING RATE
100% FOR ALL FRAME BYTE SIZES EXERCISED. FRAME LOSS RATE (%)
RESULTS: FRAME LOSS RATE LESS THAN 0.01% FOR ALL FRAME BYTE
SIZES EXERCISED. LATENCY WILL BE MEASURED WILL BE ACCORDING
TO THE FOLLOWING MAXIMUM TRANSMISSION DELAY FOR ANY CIRCUIT
UP TO 500 MILES AIR-MILES IN LENGTH SHALL BE NO
GREATER THAN 13MS ONE-WAY AND
ANY POINT-TO-POINT CIRCUIT LONGER THAN 500 AIR-MILES SHALL
BE NO GREATER THAN 50MS ONE WAY WITHIN THE 48 CONTINENTAL
STATES. ANY APS SWITCHOVER SHALL TAKE LESS THAN 50
MILLISECONDS.
G.END TO END TESTING WILL BE COMPLETED OVER A CONTINOUS 24
HOUR PERIOD WITH DOCUMENTATION PROVIDED TO THE GOVERNMENT.
H.CIRCUIT SPECIFICATIONS: MONTHLY AVAILABILITY RATE SHALL BE
99.5% OR BETTER FOR THIS REQUIREMENT.