IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 5/3/2018
SUBJECT: HC101318QA243-0002 Amend: 0002
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: PURPOSE OF AMEND 0002 IS AS FOLLOWS:
1. CHANGE THE PURPOSE TO READ; "START A COMMERCIAL LEASE USING THE IQO
CONTRACT BETWEEN IN BLDG 310 RM 101; 310 EAGLE WAY DOVER AFB, DE 19902 AND
BLDG 308 RM 203; 5450 CARLISLE PIKE, MECHANICSBURG, PA 17050-0975."
A. REQUIRE VENDOR TO DELIVER 1.0GB ETHERNET INTERFACE (OPITCAL
HANDOFF-1000BASE-LX-SINGLE MODE FIBER) AT THE DROP SIDE OF THE COMMERCIAL
DEMARC'S AT THE "A" AND "Z" LOCATIONS.
B. ADD VENDOR WIRING EXTENSION RESPONSIBILITY FOR DOVER LOCATION; "VENDOR IS
RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE
SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER SUITE (UJEWDOV040) BLDG 639, ROOM ITB TO THE DROP SIDE
OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 310,
ROOM 101 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE USED
FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL."
2. ESTABLISH NEW QUOTE DUE DATE OF 4 JUN 18.
3. EXTEND THE SERVICE DATE TO 4 SEP 18.
***ORIGINAL SOLICITATION***
1. SUBMIT A QOUTE TO PRIVIDE. INSTALL. AND MAINTAIN A 1GB ETHERNET LEASE
BETWEEN 639 ATLANTIC AVE DOVER AFB, DE 19902 TO5450 CARLISLE PIKE,
MECHANICSBURG, PA 17050-0975.
A. ESTABLISH TSP.
B. CUSTOMER WILL ACCEPT EARLIEST POSSIBLE SERVICE DATE.
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
HC101318QA243-0002
3. THE SERVICE DATE TO BE MET IS 4 AUG 18 (SIP). THE GOVERNMENT ASSUMES THAT
CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE DATE.
THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION IAW
STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04.
QUOTES SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS. QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS
UNAVAILABLE OR QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING
MAILBOX:
DISA.SCOTT.DITCO.MBX.VENDOR-QUOTES@MAIL.MIL
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101318QA244/TSR RU18OCT175672 AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR RU18OCT175672; MEANING THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER
BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION
FROM TSR RU18OCT175672.
6. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
7. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH LOCAL
POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT A MINIMUM,
CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE MAGNITUDE OF
THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE STRATEGY.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU20OCT175673C
4. CCSD: BBBB
Z. DITCO CONTACT:
Kevin Knowles
(618)229-9527 kevin.l.knowles4.civ@mail.mil
Paul A. Heard
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Aug 4, 2018
To:
Sep 4, 2018
Paragraph V.QUOTE DUE DATE AND TIME change from:
Apr 4, 2018 4:00:00 PM CDT
Jun 4, 2018 4:00:00 PM CDT
Location A, UNIQUE INSTALLATION FACTORS change from:
1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER) PORT: TBD BY LOCAL CARRIER
(3) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)
(4) FIBER TERMINATING PATCH PANEL (GFE)(DISA IE1 PROVIDED)
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWDOV040) BLDG 639, ROOM ITB TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 639, ROOM ITB USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO
BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER SUITE BLDG 639, ROOM ITB THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 310, ROOM 101.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
ASR 9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF CONNECTORS
TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND
MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
EXCHANGE CARRIER)
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWDOV040) BLDG 639, ROOM ITB TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 310, ROOM 101 USING SINGLE MODE FIBER.
COORDINATE TYPE CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
JUNIPER MX-240 ROUTER SUITE BLDG 639, ROOM ITB THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 310, ROOM 101.
TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE
CONTINUOUS.
Location A, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-NO/CPIWM-NO
CPIWI-YES/CPIWM-YES
Location B, UNIQUE INSTALLATION FACTORS change from:
(1) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, DISA IE4
(3) FIBER TERMINATING PATCH PANEL (GFE)(DISA IE1 PROVIDED)
(4) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
A. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR SERVICE FROM THE INTERFACE CARD
INSTALLED IN THE ROUTER TO THE DROP SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL.
COORDINATE TYPE OF CONNECTORS.
B. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF 1GBE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT
OF PRESENCE FIBER DISTRIBUTION PANEL. COORDINATE TYPE CONNECTORS TO BE USED FOR TERMINATION TO
THE DISA PROVIDED PATCH PANEL.
C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT THE LINE SIDE OF
THE DISA PROVIDED FIBER TERMINATING PATCH AND AT THE DROP SIDE OF THE VENDOR'S FIBER DISTRIBUTION
PANEL INSTALLED IN THEIR COMMERCIAL SUITE. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED
ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
EXCHANGE CARRIER)
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE ASR 9010 ROUTER SUITE
(UJEWMECH030) BLDG 308, ROOM 203 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 308, ROOM 203 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS
TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
ASR 9010 ROUTER SUITE BLDG 308, ROOM 203 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 308, ROOM
203.
TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE
CONTINUOUS.
Location B, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-NO/CPIWM-NO
CPIWI-YES/CPIWM-YES
Add the Following:
STANDARD PROVISION - 52 - APPROVED PRODUCTS LIST - JAN 2018
Department of Defense (DoD) Instruction 8100.04, DoD Unified Capabilities, (December 9, 2010), establishes governing policy for products and services that support and connect to the DoD Information Network (DoDIN). DoDI 8100.04 also sets forth instructions that are implemented by the Defense Capabilities Requirement (formerly the Unified Capabilities Requirement document) and the DoDIN Approved Products List (APL). VENDOR/TELECOMMUNICATIONS PROVIDER (TP) must list all equipment the TP or any subcontractor will use at the point of interface with the Government's network. The Government will evaluate the TP's list of equipment at the point of interface with the Government's network to ensure the TP proposes only equipment compliant with the DoDIN APL. A TP's failure to list equipment used at the point of interface with the Government's network, or inclusion of equipment not on the DoDIN APL, may result in the TP being deemed not technically acceptable.
Additionally, during the period of performance and contract administration, the TP is required to ensure the TP and all subcontractors use only equipment that conforms to DoDIN APL requirements at the point of interface with the Government's network. Also during performance, TP must update the Government whenever equipment is changed at the point of interface with the Government's network, and must further provide an updated list of equipment at least once per year.
ACCEPTABLE CONTRACTOR/TELECOMMUNICATIONS PROVIDER (TP) RESPONSE: "UNDERSTAND/WILL COMPLY."
NOTE: All fiber routes are fictitious and used only as an example.
:'t\ •
N
Scott AFB / 2.5GB Wave Service
- TSR SG25FEB160001 / Bldg 1575, 103 West Losey Street, Scott AFB, IL – DECC St Louis
- TSR SG25FEB160002 / Bldg 1575, 103 West Losey Street, Scott AFB, IL – Offutt AFB
DWDM
Kretschmer Ave Belleville ,IL
CLLI: BLVLILAD
Belleville, IL
DWDM
Vendor CO 1015 Locust Str St Louis, IL
CLLI: STLSMOPL
St Louis, MO
Vendor CO 125 Main Street Collinsville, IL
CLLI: CLSVILAB
Collinsville, IL
4300 Goodfellow Blvd, Bldg 103 Frame room, 1st Fl
CLLI: DCSTMODE
DECC ST Louis
103 W Losey Str Bldg 1575 Room C-1B
CLLI: SPFDILMR
Springfield, IL
Vendor Gateway 1045 River Ave St Joseph, MO
CLLI: STJSMOFR
St Joseph, MO
Vendor CO 1514 Chandler Road West
CLLI: BLLVNEBL
Bellevue, NE
901 SAC Blvd Bldg 501 Room U-127
CLLI: OAFBNEAR
Offutt AFB
Scott AFB – Offutt AFB Estimated Fiber Miles: 522 Estimated RTD: 8.3ms
Scott AFB – DECC St Louis Estimated Fiber Miles: 36 Estimated RTD: 1ms
103 W Losey Str Bldg 1575 Room C-1B
CLLI: SCABILDE
Scott AFB
DWDM
On-net
On-net
On-net
On-net
Legend:
Prime vendor: Sub-vendor B:
Sub-vendor A: Sub-vendor C:
NOTE: Vendor must indicate whether they are on-net with optical equipment at the demark locations. If not, vendor must provide the precise fiber distance from the nearest Servicing Wire Center (SWC) or Central Office (CO) where the service will be delivered from. Vendor is not authorized to deviate or change any technical parameters from the order without permission from the government.
NOTE: All addresses are fictitious (except end locations) and used only as an example.
UPDATED ADDITIONAL REQUIREMENTS FOR HC101318QA243
TELECOMM PROVIDER MUST PROVIDE TOTAL FIBER MILES AND ROUND
TRIP DELAY (RTD) FROM THE CUSTOMER "A" LOCATION TO THE CUSTOMER
"Z" LOCATION.
THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY
DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS
(SDP'S) FROM TSR RU18OCT175672; MEANING THAT THE PHYSICAL PATHS
ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, (CENTRAL
OFFICE LOCATIONS), AND FIBER BUILDS. ADDITIONALLY, AS A MINIMUM
MUST HAVE 50 METERS PHYSICAL SEPARATION FROM TSR RU18OCT175672.
VENDOR MUST PROVIDE LIGHT LEVEL
READINGS (DB LOSS) ON EXTENSION FROM COMMERCIAL POP TO GOVERNMENT
SERVICE DELIVERY POINT (SDP) AT THE "Z" LOCATION PRIOR TO
CIRCUIT TURN UP TO THE GOVERNMENT ENSURING LEVELS ARE WITHIN
SPECS. LIGHT LEVELS MUST BE ADJUSTED TO 5 TO -13.
VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO
INSTALLATION AT THE "Z" LOCATION ONLY.
VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING AND
IMPLEMENTATION GROUP UPON RECEIPT OF A VALID TSO TO ESTABLISH THE
COORDINATION AND ACTIVATION PROCESS. (C) 618-220-8627 (D)
770-8627
PROVIDER MUST CONDUCT A SATISFACTORY 72 HOUR TEST FROM THE
DROP SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN
THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THE GOVERNMENT'S SDP
AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE
COMMERCIAL DEMARC AND THE GOVERNMENT'S SDP AT THE "Z" LOCATION.
VENDOR MUST ENSURE A TEST SET IS PLACED AT THE DROP SIDE OF
TELECOMM PROVIDER'S OR LOCAL ACCESS PROVIDERS FDP AS APPLICABLE
AT THE "A" LOCATION AND A SECOND TEST SET AT THE END OF THE FIBER
JUMPERS TO BE USED FOR TERMINATION TO THE GOVERNMENT'S SDP AT
THE "Z" LOCATION. TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER
TO THE GOVERNMENT FOR ACCEPTANCE TESTING.
TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW
THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR NETWORK
INTERCONNECT DEVICES STANDARD, AND AT THE COMMITTED INFORMATION
RATE (CIR) IAW ITU-T-Y.1564 FOR AN ADDITIONAL 48 HOURS.
1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: FRAME FORMAT: 1.0GB ETHERNET (OPITCAL
HANDOFF-1000BASE-LX-SINGLE MODE FIBER), 802.3Z, 1310NM. "SC"
CONNECTORS;
(B) COMMITTED INFORMATION RATE (CIR) - 1GB.
(C) 1.0GB ETHERNET FRAMING REQUIRED AT COMMERCIAL DEMARC AT THE A
AND Z LOCATIONS.
(D) NO NETWORK INTERFACE UNIT, DEDICATED PATH
(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO CIRCUIT.
(F) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS
IAW THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR NETWORK
INTERCONNECT DEVICES STANDARD, AND AT THE COMMITTED INFORMATION
RATE (CIR) IAW ITU-T-Y.1564 FOR AN ADDITIONAL 48 HOURS
(G) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24
HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF
TROUBLE.
(I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
(K) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND
ADMINISTRATION MONITORING OF ETHERNET CIRCUIT IAW ITU-T-Y.1731.
(L) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE
GOVERNMENT BY THE DISA GOC IP BACKBONE ENGINEERING AND
IMPLEMENTATION GROUP, SCOTT AFB, IL. (C) 618-220-8627 (D)
770-8627
(M) VENDOR MUST PROVIDE:
1. THE LONG-HAUL CIRCUIT NO. AND LEC CKT ID'S AS APPLICABLE TO
THE DISA IE161 PROGRAM OFFICE PRIOR TO TURN UP TO THE GOVERNMENT.
PRIMARY: RAY BURKE (301) 225-2550 ALTERNATE: KEN DIEF (301)
225-2416.
2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF 1GBE SERVICE IAW THE UNIQUE INSTALLATION FACTORS.
3. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION
FACTORS.
4. VENDOR MUST COORDINATE SITE
VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO
FACILITIES AT BOTH USER LOCATIONS.
5. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE
TO THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP,
SCOTT AFB, IL. PRIMARY: (C) 618-220-9950, (D)770-9950 TOLL FREE:
855-868-9950
6. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO
350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS
AVAILABLE AT <HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>
CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL
COMMUNICATIONS ACQUISITION PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 1.0709 GIGABITS/S, +- 100 PPM LINE CODE: OPTIC
1. TEST AND ACCEPTANCE: FIBER OPTIC 1.0GB CIRCUITS SHALL PASS A
FULLY DOCUMENTED SATISFACTORY 24 HOUR SOAK TEST BY DISA GOC AT
SCOTT AFB, IL. PRIMARY: (C) 618-229-8691 (D) 779-8691;
2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING
PARAMETERS SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING.
ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER THE
DURATION OF THE CONTIGUOUS 24 HOUR TESTING INTERVAL AND SHALL BE
MEASURED AND RECORDED PER DEFINITION IN ITU-T-Y.1564.
3. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE
FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY
SHALL BE GREATER THAN 99.5% OR BETTER. FRAME LOSS SHALL BE EQUAL
TO ZERO WHEN TESTING AT 1.0 GIGABIT HIGHEST FRAME RATE, AND SHALL
MEET ITU-T-Y.1564 STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC.
DELAY SHALL BE BETTER THAN 10 MSEC
4. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE
GREATER THAN 24 HOURS.
5. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 1GB
WAVE CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS.
IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET /
SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTA
TION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONS
TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL
.MIL, OR CALL DSN 770-8627; COML 618-220-8627.
DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
FACILITY SECURITY ACCESS REQUIREMENT: (SP A) ESCORT REQUIRED;
(SP B) ESCORT REQUIRED;
(SP C) ESCORT REQUIRED;
(SP D) ESCORT REQUIRED;
COMPLETION REPORT: SERVICE WILL BE ACCEPTED ON BEHALF OF THE U.S.
GOVERNMENT BYDISA GOC IP B/D312-770-8627,C618-220-8627 WHO WILL
SUBMIT A COMPLETION REPORT IAW DISAC 310-130-1, CHAP 2 OF DISAC
310-70-1, CHAP 8. REPORT WILL BE ADDRESSED TO THE ORIGINATOR AND
ALL ADDRESSEES OF THIS TSO.
| - Vendor Sample Maps_Version2.pdf |
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| - Vendor Block Sample_Version2.pdf |
| Scott AFB / 2.5GB Wave Service�- TSR SG25FEB160001 / Bldg 1575, 103 West Losey Street, Scott AFB, IL – DECC St Louis�- TSR SG25FEB160002 / Bldg 1575, 103 West Losey Street, Scott AFB, IL – Offutt AFB |
File details come from the government source that posted it.