HC101317QA148-0002.v0.pdf
PDF 62 KB Posted
- Attached to
- AN OC-12C SERVICE
- Solicitation number
- HC101317QA148
- Issued by
-
Defense Information Systems Agency
About this file
HC1013-17-QA-148 AMEND 0002
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101317QA148.v1-2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 2/28/2017
SUBJECT: HC101317QA148-0002 Amend: 0002
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE:
*****AMENDMENT 0001 IS ISSUED TO EXTEND DUE DATE OF QUOTES TO 15 MAR
17. SERVICE DATE IS ALSO CHANGED TO 31 JUL 17 (SIP). ALL VENDORS MUST
CLEARLY STATE IN QUOTES THEIR COMPLIANCE WITH GOVERNMENT TESTING AND
ACCEPTANCE REQUIREMENTS. ALL ELSE REMAINS THE SAME.*****
1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A. LEASE AN OC-12C
SERVICE BETWEEN BLDG 1901, ROOM 25, 1901 EAST 3RD STREET, MCGUIRE AFB,
NJ., AND BLDG 9800, ROOM M2AB104, 9800 SAVAGE ROAD, FORT MEADE, MD.;
THE RTD TO BE MET SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS TO
EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION.
2. SEE UNIQUE INSTALL FACTORS.
3. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND
AGREEING WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC
TECHNICAL REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED
SERVICE DATE. FAILURE TO READ AND ADHERE TO ANY PORTION OF THE
INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND RESULT IN IT BEING
EXCLUDED FROM EVALUATION AND AWARD.
4. THE SERVICE DATE TO BE MET IS: 31 JUL 17 (SIP). THE GOVERNMENT
ASSUMES THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT
THE SERVICE DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST
CONSIDERATION IAW STANDARD PROVISION 42 FOR FAILURE TO MEET
CONTRACTUAL SERVICE DATE OR COMPLY WITH ANY CONTRACT TERMS OR
CONDITIONS.
5. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04.
QUOTES SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND
SHOULD NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS.
RATHER, THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE
CONTRACTOR INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS
SOLICITATION, NO TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR
ASSUMPTIONS WILL BE ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT
QUESTIONS AND REQUEST CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE
SUBMITTING QUOTES. QUESTIONS SHALL BE SUBMITTED TO CONTRACT
SPECIALIST AND CONTRACTING OFFICER DURING THE SOLICITATION PHASE ONLY,
AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE POSTED TO FEDBIZOPPS.
HC101317QA148-0002
6. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC1013-17-QA-154/TSR RU09DEC165055, AND MUST BE ENGINEERED AND
PROVISIONED TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE
DELIVERY POINTS (SDP) FROM TSR RU09DEC165056; MEANING THE PHYSICAL
PATHS ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL
OFFICE LOCATIONS, AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST
HAVE 50 METERS PHYSICAL SEPARATION FROM TSR RU09DEC165055
6. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE
ROUTES FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES
AND/OR WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY
REQUIREMENTS ARE BEING MET. DRAWINGS MUST INCLUDE SEPARATION
DISTANCES, TOTAL FIBER MILES AND ROUND TRIP DELAY BASED ON ACTUAL
DISTANCE IN MILES. REFER TO STANDARD PROVISION 39 FOR SPECIFIC
DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE INCLUDED THE
ATTACHMENTS.
7. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH
LOCAL POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT
A MINIMUM, CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE
MAGNITUDE OF THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE
STRATEGY.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU09DEC165056
4. CCSD: DBH3BTF3
Z. DITCO CONTACT:
Rory Brooks rory.j.brooks.civ@mail.mil
Angelina Hutson
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Jul 10, 2017
To:
Jul 31, 2017
Paragraph F.2.SIGNALING MODE change from:
NO SIGNALING
No Signaling
Paragraph V.QUOTE DUE DATE AND TIME change from:
Feb 8, 2017 12:00:00 PM CST
Mar 15, 2017 12:00:00 PM CDT
Attachments Begin After This Page.
ATTACHMENT
QUOTE PREPARATION MUST BE IN ACCORDANCE WITH STANDAR PROVISION
4- BELOW IS INFORMATION REQUIRED FOR EVALUATION
COMPANY NAME:
CAGE CODE:
BASIC AGREEMENT:
PURPOSE STATEMENT:
CONTRACTORS MUST EXPLAIN IN DETAIL HOW THEY INTENT TO PROVIDE
THE SERVICE AND SATISFY THE TECHNICAL REQUIREMENTS.
VENDORS MUST CLEARLY STATE IN QUOTES THEIR COMPLIANCE WITH
GOVERNMENT TESTING AND ACCEPTANCE REQUIREMENTS.
CONTRACTOR MUST INDICATE IF THEY ARE ABLE TO COMPLY WITH
REQUIRED RTD OF XX. THE ACTUAL DISTANCE BETWEEN LOCATIONS AND
PATH INFORMATION MUST BE PROVIDED.
CONTRACTOR PROPOSED SERVICE DATE:
____CALENDAR DAYS ARO
____BUSINESS DAYS ARO
____REQUESTED SERVICE DATE
EXTENSIONS: MUST ANSWER YES/NO IF PROVIDING EXTENSIONS. N/A IF NOT
APPLICABLE/REQUIRED
____LOCATION A
____LOCATION B
PRICE: MUST ITEMIZE ALL PROPOSED PRICES IN ACCORDANCE WITH
STANDARD PROVISION 4.
MRC:
NRC:
TOTAL PRICE:
QUOTE DATE AND HOW LONG QUOTE IS VALID.
BILL DATE:
IMPORTANT: QUOTES SHALL NOT CONTAIN TERM PRICING OR EARLY
TERMINATION LIABILITY PENALTIES.
NOTE: VENDOR CAN USE THIS TEMPLATE OR INCLUDE THE REQUIRED
INFORMATION ON COMPANY TEMPLATE.
File details come from the government source that posted it. Updated .