This posting provides references for a sole source requirement for dynamic positioning services on the NOAA ship Reuben Lasker. The references indicate that the incumbent contractor, Marine Systems, Inc., has successfully provided dynamic positioning services on the Reuben Lasker since 2015. The references describe Marine Systems' experienced crew, their familiarity with the vessel through previous contracts, and their satisfactory performance in maintaining the dynamic positioning system.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES

A

B

C

D

A

B

C

DRAWING NO. SH REV

D

A

D

REVDRAWING NO.SIZE

USCG APVD: DATE:

SCALE

ABS APVD: DATE:

FSCM CAGE NO.

98042

OF

FSV6-320-01

FSV6-320-01 G

H

1 39N.T.S.

12345678

1345678

REVISIONS

SHT REV DESCRIPTION DATE APPROVED

C REV C 12/02/1 T.T.

D REV D 3/13/13 T.T.

E REV E 8/16/13 D.K.

CONTRACT NO: AB133M-10-CN-0091

DWN:

MARINETTE WISCONSIN 54143

CHKD:

APRV:

APRV:

PE STAMP:

DATE:

Consulting Engineers Serving the Marine Community

1201 Western Avenue, Suite 200 Seattle, Washington 98101-2921

TEL

FAX

WEB

206.624.7850 206.682.9117 www.glosten.com

NATIONAL OCEANIC &

ATMOSPHERIC ADMINISTRATION

(NOAA)

FISHERIES SURVEY VESSEL 6

(FSV6)

10/01/10

10/01/10

10/01/10

10/01/10

C.J.

B.J.

B.J.

A.R. DIAGRAM

ONE-LINE

POWER

1. THIS DRAWING WAS DEVELOPED IN ACCORDANCE WITH ABS, USCG AND

IEEE STANDARD 45 REQUIREMENTS.

2. STEERING PUMP CIRCUIT BREAKERS SHALL HAVE AN "INSTANTANEOUS

MAGNETIC TRIP ONLY" SET AT 175-200% OF THE LOCKED ROTOR CURRENT

VALUE IN ACCORDANCE WITH USCG 46 CFR 58.25-55(a)(2).

3. THE STEERING CIRCUITS SHALL MEET ALL OF THE REQUIREMENTS OF

ABS "RULES FOR BUILDING AND CLASSING STEEL VESSELS UNDER 90

METERS (295 FEET) IN LENGTH" SECTION 4-6-2/11, USCG

46CFR58.25-55, AND 46CFR113.43.

4. ALL ABBREVIATIONS ARE IN ACCORDANCE WITH MIL-STD-12D UNLESS

OTHERWISE NOTED.

5. ALL CABLE IS LOW SMOKE HALOGEN TYPE IN ACCORDANCE WITH

MIL-C-24643 OR COMMERCIAL MARINE TYPE "XIU" UNLESS OTHERWISE

NOTED.

6. THE FOLLOWING 600V OPERATIONAL BUS TIE CONFIGURATIONS SHALL BE

PROVIDED:

• OPERATION OF ANY COMBINATION OF GENERATORS CONNECTED IN PARALLEL

TO THE INTEGRATED PROPULSION AND SHIP SERVICE BUS.

• SEPARATE GENERATOR(S) DEDICATED TO SHIP SERVICE ELECTRIC LOADS

AND TO PROPULSION PLANT LOADS. PROPULSION PLANT LOADS IN THIS

CASE INCLUDE BOW THRUSTER.

• SEGREGATION OF THE BOW THRUSTER AND GENERATOR FROM ALL OTHER

LOADS.

7. PROPULSION CABLE MUST BE CERTIFIED IN ACCORDANCE WITH ABS

4-1-1/3.3 PRIOR TO SHIPMENT OF CABLE TO YARD.

8. WHEN THE SHIP IS ON SHORE POWER, MEANS ARE PROVIDED TO

PREVENT INADVERTENT PARALLELING OF SHIP'S GENERATORS WITH SHORE

POWER UPON LOSS OF SHORE POWER. SCIENTIFIC POWER SYSTEMS ARE

NOT INTERRUPTED DURING TRANSFER TO AND FROM SHORE POWER.

9. BREAKERS FOR MOTOR CIRCUITS IN MOTOR CONTROL CENTERS WILL BE

MOTOR CIRCUIT PROTECTION BREAKERS ONLY INSTANTANEOUS ADJUSTABLE

MAGNETIC TRIP UNITS SHALL BE USED, IN CONFORMANCE WITH N.E.C. PART

430D. EACH MCP SHALL BE SIZED AND ADJUSTED TO CARRY THE STARTING

CURRENT OF THE MOTOR. ALL OTHER BREAKERS NOT NOTED MCP WILL BE

THERMAL MAGNETIC BREAKERS.

10. ALL CIRCUIT BREAKERS ARE 3 POLE UNLESS LABELED 2P FOR

TWO-POLE OR 1P FOR SINGLE POLE.

11. BONDING AND GROUNDING SHALL BE IN ACCORDANCE WITH REFERENCE

9. CABLES EXITING THE HULL OF THE SHIP SHALL BE SHIELDED OR RUN IN

EMI CONDUIT OR PIPE IN ACCORDANCE WITH REFERENCE 11. FOR SHIELDED

CABLE INSERT GROUND ADAPTERS IN SWAGE TUBE.

12. CONTROLLERS SHALL BE FULL VOLTAGE NON REVERSING, 600/480VAC

AS REQUIRED, 60 HZ, 3 PHASE IN NEMA 12 DRIPPROOF ENCLOSURE AND

SHALL INCLUDE A CONTROL POWER TRANSFORMER (600/480-120VAC) WITH

FUSES FOR BOTH PRIMARY AND SECONDARY LEGS AND A TERMINAL STRIP

FOR WIRING EXTERNAL DEVICES. CONTROLLERS SHALL MEET THE

REQUIREMENTS OF ABS, USCG, IEEE-45 AND UL 508 INCLUDING MARINE

SUPPLEMENT.

13. SOLID STATE PASSIVE INSULATION RESISTANCE MONITORS, IN

ACCORDANCE WITH ASTM F1134, SHALL BE PROVIDED FOR GENERATORS AND

MOTORS FOR PROPULSION, STEERING, HYDRAULIC POWER, SEAWATER AND

FRESH WATER SERVICES, AND THOSE MOTORS IN THE WEATHER SUBJECT TO

MOISTURE CONDENSATION. THE INSULATION RESISTANCE MONITOR SHALL

ACTIVATE A LOCAL RED "IRM ALARM" PILOT LIGHT IN THE FACE OF THE

CONTROLLER, AND AT THE EOS FOR A LOW INSULATION CONDITION.

14. MOTOR CONTROL CENTERS SHALL BE NEMA TYPE 1 DRIPPROOF

ENCLOSURES WITH COPPER HORIZONTAL AND VERTICAL BUSES. WIRING SHALL

BE NEMA CLASS 1, TYPE B AND CONNECTION INPUT TERMINALS SHALL BE

MOUNTED AS REQUIRED FOR CABLE ENTRY. ALL STARTERS ARE

COMBINATION TYPE. MOTOR CONTROL CENTERS SHALL MEET THE

REQUIREMENTS OF ABS, USCG, IEEE-45 AND UL 845.

15. FOR CIRCUIT BREAKER SETTINGS ON 600 VOLT, 480 VOLT AND

EMERGENCY SWITCHBOARD, SEE COORDINATION STUDY (REF 3).

16. CIRCUIT BREAKERS REFERENCING THIS NOTE SHALL BE CAPABLE OF

BEING 'LOCKED-OUT' IN THE OFF POSITION.

17. ALL PROPULSION CABLES SHALL BE TESTED IN ACCORDANCE WITH ABS

4-6-5/3.17.12(e) BY THE SUPPLIER PRIOR TO SHIPMENT.

18. NON-STANDARD ABBREVIATIONS:

• A/C - AIR CONDITIONING

• GCC - GROUP CONTROL CENTER

•MSD - MARINE SANITATION DEVICE

• ECC - ENGINEER'S CONTROL CONSOLE

•MCC - MAIN CONTROL CONSOLE

19. THE MOTOR HEATERS FOR THE VENT FANS SHALL BE SUPPLIED FROM

THE MOTOR CONTROLLER FOR THE FAN AND THE CONTROL POWER

TRANSFORMER SHALL BE SIZED TO CARRY THE LOAD OF THE HEATER.

HEATERS SHALL BE INTERLOCKED TO COME ON WHEN MOTOR IS SECURED.

20. ALL POWER PANELS AND LOAD CENTERS ARE TO BE NEMA 1,

DRIPPROOF.

21. CONTROLLER SHALL BE TWO SPEED REVERSING, SINGLE WINDING,

CONSTANT HORSEPOWER FOR REMOTE CONTROL ONLY. SHALL ALSO HAVE

NON-FUSED DISCONNECT AND CPT FOR CONTROL POWER. CPT SHALL BE

SIZED AND WIRED TO POWER SPACE HEATER FOR MOTOR.

22. AUTO TRANSFER SHALL SWITCH TO THE OTHER BUS IF THERE IS A

FAILURE ON THE BUS FOR ANY REASON.

23. ALL CIRCUIT BREAKERS LOCATED IN THE ENGINE ROOM/MACHINERY

SPACE WILL BE RATED FOR 50C AMBIENT TEMPERATURE IAW 116 CFR

111.54-16e.

24. GROUND GRID - PROPULSION MOTORS PROPULSION DRIVES AND

PROPULSION TRANSFORMERS SHALL BE GROUNDED AT THE MAIN

SWITCHBOARD. NO OTHER GROUNDS SHALL BE INSTALLED ON THIS

EQUIPMENT.

25. ALL CABLES BETWEEN VARIABLE FREQUENCY DRIVES (VFD) AND ITS

MOTOR(S) SHALL BE VFD-RATED. ALL MOTORS CONNECTED TO VFDs SHALL

BE INVERTER DUTY-RATED.

26. ALL 208V & 120V DISTRIBUTION PANELS HAVE AN ISOLATED NEUTRAL

BUS.

27. REFER TO ELECTRIC PLAN LOAD ANALYSIS, FSV6-300-01, FOR POWER

RATINGS NOT DESIGNATED ON THIS DRAWING.

MISSION SCIENTIFIC BLOCK WIRING DIAGRAM

EXTERIOR COMMUNICATIONS BD

NAV, SIG, & SEARCHLTS ARR & WD

CATHODIC PROT SYS ARR & DET

W.T. DOOR SYSTEM WD

I.C. SYSTEMS BD

LCTN. OF PRPLN. CONT & AUTOMATION EQPT

CABLEWAY KEY PLAN

ELEC STANDARDS WRG PRACTICES & INSTALL DETAILS

STEERING CONTROL SYSTEM BD

FIRE ALARM SYSTEM WD

LIGHTING SYSTEM ONE LINE DIAGRAM

PHASE BALANCE STUDY

VOLTAGE DROP CALCULATIONS

BREAKER COORDINATION STUDY

FAULT CURRENT ANALYSIS

DRAWING TITLE

REFERENCE DRAWINGS

POWER LOAD ANALYSIS

NO.

FSV6-300-01

DE-ICING SYSTEM ARR & DET18

MACHR'Y CTL & ALARM SYS BD19

ARRANGEMENT OF ELECTRICAL PWR EQUIPMENT

BOW THRUSTER SYSTEM BLOCK DIAGRAM

22 WINCH & TRAWL CTL SYS BD

SHIPS INTERIOR COMMUNICATION SYS BD

DYNAMIC POSITIONING SYS BD23

25 MAIN MACHINERY ROOM ARRANGEMENT

26 CCTV/CATV/CLOCK/H2SO4 BWD

27 SHIP'S METEOROLOGICAL EQUIPMENT BD

SHIP'S SERVICE COMPRESSED AIR SYS DIA

PROPULSION CONTROL SYSTEM BD

PROPULSION SYSTEM TERMINATION LIST

PIPING SYSTEM DIAG - FRESH & POT WTR

MISCELLANEOUS HOOKUP

MMC DWG NO.

P603 & P604

SCIENCE POWER SWITCHBOARD

EMERGENCY GEN, SWITCHBOARD & 24VDC SYS

600V & 480V DISTRIBUTION SWITCHBOARDS

PROPULSION MOTORS & BT MOTORS/DRIVES

PARTS LIST

DESCRIPTION

PARTS LIST3

SYMBOL LIST

SHEET

INDEX

P610 & P616 P614, P415A & P415B

P607 & P608

25 P420, P222 & P120-1

P416, P419 & P103 P405, P406, P415

P111-3 & P111-4 P111-1 & P111-2

P609, P609-1 & P609-2

SCP107A & SCP107B

SCP104A & SCP104B

EP404, EP122-A & EP128

SHEET DESCRIPTION

P619 & P620

P411 & P412

29 SCP103A, SCP105A, SCP106A & SCP110A

SCP110A-331

32 SCP110A-4 & SCP110A-5

SCP110A-6 & SCP110A-733

SCP110A-1 & SCP111A

P112-119

600V SWITCHBOARD & GENERATORS5

PROPULSION TRANSFORMERS AND DRIVES6

35 BLANK

EMER LOUVERS WD36

1 GENERAL MOTES, REFERENCES, SHEET INDEX

PRPLN SYS GND GRID INSTALL & CABLE DIAG

DETAIL 298-B, WASTE OIL HEATER INTERLOCK38

FSV6-300-02

FSV6-300-03

FSV6-300-04

FSV6-300-05

FSV6-330-01

FSV6-610-01

FSV6-426-01

FSV6-321-01

FSV6-304-01

FSV6-201-01

FSV6-432-01

FSV6-437-01

FSV6-633-01

FSV6-422-01

FSV6-441-01

FSV6-461-01

FSV6-333-02

FSV6-202-01

FSV6-437-02

FSV6-301-01

FSV6-437-06

FSV6-438-03

FSV6-432-01

FSV6-200-01

FSV6-439-01

FSV6-493-01

FSV6-202-05

FSV6-551-01

FSV6-202-04

FSV6-533-01

FSV6-430-01

P605 & P606

34 SCP110A-8

RES. NO.

RESERVATIONS

R001

DESCRIPTION DATE APPROVED

PENDING VENDER INFORMATION 10/01/10 B.J.

- 10/01/10

1A REVISIONS

33 MISCELLANEOUS HOOKUP FSV6-437-08

1-38 B.J.INITIAL ISSUE

1-38 A REV A BJ2/16/11

34 INTEGRATED BRIDGE SYSTEM BD FSV6-438-01

1-38 B REV B 8/04/11 T.T.

35 HVAC DIAGRAM SUPPLY AND EXHAUST FSV6-512-01

36 HVAC CONTROL SYSTEMS FSV6-437-09

SCP110A-2 & SCP110A-939

20 P112-2

1B REVISIONS

37 MISCELLANEOUS ALARM SYSTEMS FSV6-436-02

1-39

1C REVISIONS

1D REVISIONS

1-39 1-39

1E REVISIONSF

1 - 39 H REV H 6/ 28/ 22

B

C

D

A

B

C

DRAWING NO. SH REV

D

A

D

REVDRAWING NO.SIZE

USCG APVD: DATE:

SCALE

ABS APVD: DATE:

FSCM CAGE NO.

98042

OF

FSV6-320-01

FSV6-320-01 G

H

1A

1A 39N.T.S.

9A10A11A12A13A14A15A16A

9A11A12A13A14A15A16A

DATEDESCRIPTIONZONE REV

REVISIONS

APPROVED

1. GENERAL NOTE 6 WORDING WAS "OPERATION OF ANY NUMBER OF GENERATORS."

A

7D

2. REVISED GENERAL NOTE 8, WAS "SHIP SERVICE GENERATORS SHALL BE

INTERLOCKED WITH SHORE POWER TO PREVENT PARALLELING THE TWO."

3. GENERAL NOTE 11 BONDING & GROUNDING WAS CALLED OUT AS REFERENCE 11.

7C

7C

5. REVISED RESERVATION R001 FROM PENDING HVAC SOLICITATION.5A

5A 3D

4. COMPLETELY REPLACED GENERAL NOTE 23.

SH 1A 9. ADDED SHEET 1A.

10. REVISED DESCRIPTION OF THRUSTER TRANSFORMERS.

6. REVISED REV - ISSUE DESCRIPTION & DATE. ADDED REV A ISSUE INFORMATION.

7. ADDED REFERENCE DWG # 33.

8. ADDED SHEET 1A TO SHEET INDEX.

22C 11. ADDED PART NO'S FOR ITEMS 30 & 31.

13. BUS A & D WERE CON'T ON SH 5.

19C

39C

14. ADDED 6GP-1B & CABLE SIZE37C

12. ADDED MANUFACTURER AND PART NO. FOR ITEM 100 & DELETED REMARKS.

15. P081 & P091 WERE (4) LSDSGU-400.42B

46B 51C

17. RELEASED RESERVATION R001.

52C 59A-

18. REVISED SHORE POWER FROM REF 25 TO REF 21.

63C 60C

68A

19. REVISED PHASE SHIFTING XFMR FROM

20. REVISED WATERTIGHT DOOR REFERENCE FROM 16 TO 13.

59C

7A

5B

15C

34C,

16. P081 & P091 WERE (4) LSDSGU-400.

VV

67C 67C

21. ADDED CABLE TYPE TO EP415.

22. CIRCUIT EP407 WAS SPARE. ADDED WATER MIST SYS. (SOLAS REQ.)

69C 23. CIRCUIT EP404 WAS LSTSGU-200.

74C 24. ADDED AMP METER TO GROUND DETECTION CIRCUIT.

84B 25. REVISED IRM FROM REF 23 TO REF 19.

92C 26. DELETED REF ON P107-3(C) & P107-4(C).

94C 27. REVISED C-AM-500-19 & C-AM-500-6 FROM REF 23 TO REF 19.

102A 28. REVISED POTABLE WATER SKID TO FWD STBD BULKHEAD.

108C 29. REVISED STBD BRIDGE CONSOLE FROM REF 26 TO REF 22.

110B 30. REVISED IP415-A & B FROM SEE SHEET 23 TO SEE SHEET 8.

110C

31. RELEASED RESERVATION R001.118D

32. P610-1 WAS LSTSGU-41.118D

33. RELEASED RESERVATION R001.123D

125D

34. RELEASED RESERVATION R001.131D

133D 135D

35. IRM WAS REF 23 NOW REF 19.130B

36. P609-5 WAS LSTSGU-41.133D

37. RELEASED RESERVATION R001.139D

141B 142D

38. RELEASED RESERVATION R001.149D

39. RELEASED RESERVATION R001.157D

40. RELEASED RESERVATION R001.163D

166D

41. RELEASED RESERVATION R001.173D

42. P111-4A WAS LSDSGU-9.171C

43. P416-8 & P416-8(M) WERE LSTSGU-9.178C

179C

44. ADDED REF 14 TO CATHODIC PROTECTION.181D

45. P419-3 WAS 2P.182D

46. P103-14 & P103-15 WERE SPARE.181A

47. P103-13 WAS 2P.182A

48. REFERENCE DRAWING WAS REF 22.189A

49. ADDED REF 14 TO P222-14.194B

50. P120-1B WAS 2P.199B

51. EP128-14 WAS 3P.202B

191B

52. EP128-20 WAS SPARE.202B

53. EP404 WAS LSTSGU-200.206D

54. EP122-A19 WAS SPARE.207A

55. SCCP104A & B WERE NEMA-4 W/DRIPSHIELD, SURFACE MTD(LOCATED: WET LAB).211B

56. SCP104A-10 WAS 2P.214C

57. SCP104B WAS, SURFACE MTD.119B

58. SCP107B-15 WAS LSTSGU-9, UNTERNET PWR SW (IPS-400).219C

221C 59. SCP107A-14 WAS LSTSGU-4, PRESERVATION ALCOVE RECEPTACLE STRIP.

223C 60. SCP107A-11 WAS LSTSGU-4, PRESERVATION ALCOVE RECEPTACLE STRIP.

SCP107A-13 WAS LSTSGU-4, PRESERVATION ALCOVE RECEPTACLE STRIP.

226B 61. SCP110A WAS LSFSGU-75.

235D 62. SCP110A-1B WAS 35AT, LSDSGU-9, VSAT CABINET.

235C 63. SCP110A-1D(102), WAS 15AT, LSDSGU-4, REF 26.

233C 64. SCP110A-1M(202), WAS REF 26.

235D 65. SCP110A-1A, WAS REF 35.

236C 66. SCP110A-1J WAS REF 21.

235C 67. SCP110A-1L WAS REF 26.

235C 68. SCP110A-1T WAS REF 26.

235C 69. SCP110A-1W(4) WAS REF 26.

DESCRIPTIONZONE REV APPROVED

70. SCP111A-1 WAS REF 35.239D

244C

244B

76. SCP110A-5 WAS NEMA-4 & IN FISH LAB.251B

252B 254B

75. SCP110A-3 WAS SURFACE MTD..

260B 80. SCP110A-7R WAS REF 21.

81. SCP110A-7J WAS SPARE.

77. SCP110A-5T(99) WAS REF 26.

79. SCP110A-7T WAS BONGO NET PROFLIER, LSDSGU-4.

263C 82. SCP110A-6R WAS 30AT.

84. ADDED LSTSGU-23 TO SCP110A-8.

267B

277A 85. ADDED RESERVATION R001 CALL-OUT.

277A

83. RE-DREW DETAIL 267-B SHOWING DASHED LINES PROPERLY.

REV A AUTHORIZATION.

42B 46B

244B

260B

260C

270C

71. SCP110A-3M WAS REF 21.244C

72. SCP110A-3P WAS REF 21.

73. SCP110A-3S WAS REF 21.244B

74. SCP110A-3U WAS REF 21.

78. SCP110A-4 WAS NEMA-4 & IN WET LAB.

CONTINUED ZONE 14A-D THIS SHEET.

6D 86. ADDED GENERAL NOTE 26.

92C 87. C-AM-500-142 WAS RES 23, NOW RES 19.

135A

CONTINUED FROM ZONE 11A-A THIS SHEET.

REVISIONS

NOAA- REF. COMMENT TRANSMITTAL INFORMATION LETTER: DATE DEC 27, 2010,

TRANSMITTAL SERIAL NO. 0120-0133.

ABS- REF. ABS REQ. TRANSMITTAL LETTER.

TRANSMITTAL SERIAL NO. 0120-0133.

OPN: 2416603

TASK NO:642098

SOLAS-REF. SOLAS REQ., EDITION (2009) CHAPTER -2,

PART C, REQ. 10, SECT 5.6.

MMC- REF. DESIGN DEVELOPMENT & IMPROVEMENT.

59C 88. CIRCUIT P613 WAS WINCH PWR PNL NO. 2. NOW SPARE.

214B

89. EP404-6, 10, 11 & 12 WERE SPARES. ADDED XMFR'S & GA/PA NODES.

207C 205C

258B 90. SCP110A-7S & SCP110-7U WERE SPARES.

258C

221C 91. SCP107A-8 WAS SPARE IS SCIENTIFIC SEAWATER.

204C 92. EP128-5 WAS PA PANEL, LSDSGU-9, IS SPARE.

229C 93. SCP103A WAS SHIP'S INTERCOM SYS, LSTSGU-4, IS SPARE.

29B 94. ADDED ITEM 221 TO PARTS LIST.

APPROVEDDATE

APPROVEDDATEDESCRIPTIONREV

CONTINUED ZONE 16A-D THIS SHEET.CONTINUED ZONE 11B-D SHEET 1B.

B

8/04/11 TT1. ADDED REFERENCE 34, 35, AND 36.

2. ADDED SHEETS 1B AND 39 TO INDEX.

3. REVISED REFERENCE 16 (WAS INTEGRATED BRIDGE

(FSV6-438-01).

4. RELEASED RESERVATION R001.

5. ADDED SHEET 1B.

6. ADDED SYMBOL FDC.

7. REVISED ITEMS 1-4 (ADDED WEIGHTS), ITEMS 92-95

(CORRECTED MMC PART NUMBER), AND ITEM 94 (ADDED PNL

SERVICE TO DESCRIPTION).

8. REVISED ITEMS 168 (WAS QTY 8) ,169 (WAS SOLENOID VALVE)

AND 222 (WAS ITEM NO. 221.

9. DELETED ITEMS 187, 212, 215.

10. ADDED ITEMS 221 & 223-226.

11. ADDED MMC PART NUMBER FOR ITEM 189 AND 190.

12. DELETED CIRCUITS P410-1 AND P415-1.

13. ADDED TRAWL SYS XFMR ITEM 226.

14. DELETED IRM CIRCUITS FROM ITEM 91 & 92.

15. REVISED DESCRIPTION (WAS STEERING CTRL PNL).

16. REVISED DESCRIPTION (WAS STEERING CTRL PNL).

17. REVISED NOMENCLATURE FOR CIRCUITS CP24-13 (WAS

STEERING CTRL PANEL), CP24-15 (WAS STEERING ALARM

UNIT), AND CP24-16 (WAS SPARE).

18. REVISED DESCRIPTION (WAS ENVIRONMENT UNIT)

19. DELETED CIRCUITS P604-13, P604-14, AND P103-1B.

20. DELETED JUNCTION BOX, (ITEM 187) AND CIRCUIT P603-6A.

21. DELETED CIRCUIT P608-10 P103-1A, AND ONE BLANK

CIRCUIT FROM P608.

22. REVISED BREAKER RATING AND NOMENCLATURE OF CIRCUIT

P607-2 (WAS 20AT/SCR DRIVE #2).

23. REVISED REFERENCE SHEET NUMBER FOR CIRCUIT

P105-6(C3).

24. DELETED CIRCUITS P103-4A, P607-12, P607-13, P607-14,

AND P607-15.

25. DELETED THREE BLANK CIRCUITS FROM PANEL P607.

26. REVISED BREAKER TYPE/RATING FOR CKT P606-6 (WAS 15A).

27. REVISED SPELLING OF INCINERATOR AND REFERENCE SHEET

NUMBER FOR CIRCUIT P105-6(C3).

B

SHEET

SHEET

REVISIONS

28. DELETED CIRCUIT P103-8(A) AND IRM CIRCUIT.

29. REVISED CABLE SIZE OF CKT P614-7 (WAS LSTSGU-23).

30. ADDED CIRCUIT BREAKER TO CIRCUIT P614-2.

31. REVISED CONFIGURATION OF GCC P610 AND P616 TO

LATEST HVAC DATA.

32. RELEASED RESERVATION R001.

33. DELETED GAYLORD HOOD SYSTEM DIAGRAM.

34. DELETED GALLEY/SCULLERY DUCT HEATER WIRING

DIAGRAM.

35. REVISED CONFIGURATION OF GCC P620 TO LATEST HVAC

DATA.

36. REVISED CONFIGURATION OF GCC P619 TO LATEST HVAC

DATA.

37. REVISED CONFIGURATION OF GCC P609-1, P609, AND

P609-2 TO LATEST HVAC DATA.

38. REVISED CONFIGURATION OF P411, P412, AND P412-3

TO LATEST HVAC DATA.

39. REVISED NOMENCLATURE OF CIRCUITS P112-1C AND

P112-1E TO AGREE WITH LATEST HVAC DATA.

40. REVISED CONFIGURATION OF P112-2 TO LATEST HVAC

DATA.

41. REVISED CONFIGURATION OF P111-1 AND P111-2 TO

LATEST HVAC DATA.

42. REVISED CONFIGURATION OF P111-3 AND P111-4 TO

LATEST HVAC DATA.

43. DELETED FN 212 213, 214, AND 215 FROM CIRCUIT

P419-1.

44. REVISED NOMENCLATURE OF CIRCUIT P103-14A.

45. DELETED CIRCUITS P419-9 (WAS BT UNIT HEATER) AND

P103-1 (WAS IRM TO GCC P608 AND P604).

46. ADDED CIRCUITS P419-11 AND P103-16.

47. ADDED CALLOUT (FN 223) TO CIRCUIT P416-10.

48. DELETED CIRCUITS P415-1 AND P410-1.

49. REVISED NOMENCLATURE OF CIRCUITS, WAS P410-1C

AND P410-1B.

50. REVISED LOCATION OF TRANSFORMER P420-1 (WAS MMR

2ND DECK PORT).

51. REVISED LOCATION OF POWER PANEL P120-1 (WAS

GALLEY).

52. ADDED STEAMER CIRCUIT P420-3.

53. REVISED NOMENCLATURE OF CIRCUIT P420-9.

54. REVISED CABLE TYPE OF CIRCUIT P420-4 WAS

LSTSGU-4.

55. DELETED CIRCUITS P222-7, P222-8, P222-9, P222-10,

AND P222-16.

56. REVISED CKT NOMENCLATURE (WAS MCC UPS NO.1).

57. REVISED CKT NOMENCLATURE (WAS MCC UPS NO. 2).

58. REVISED CKT NOMENCLATURE (WAS SCC PWR SUPPLY

NO.2).

59. REVISED CKT NOMENCLATURE (WAS SCC PWR SUPPLY

NO.1).

60. REVISED CKT NOMENCLATURE (WAS HF#2).

61. REVISED CKT NOMENCLATURE (WAS HF#1 INMARSAT B#1).

62. REVISED NOMENCLATURE OF CIRCUITS EP404-1,

EP404-2, EP404-3, EP404-4, EP404-11, EP404-12A,

EP122-A19A, EP128-4, EP128-6, EP128-14,

EP128-16, AND EP128-18.

63. ADDED CIRCUITS EP128-5, AND EP128-13.

64. DELETED CIRCUIT EP122-A6 (WAS SCC UPS).

65. ADDED CIRCUITS SCP104A-11 AND SCP104A-12.

66. DELETED CIRCUITS SCP107A-9 AND SCP107A-12 FOR

PRESERVATION ALCOVE.

67. ADDED CIRCUITS SCP105A-23, SCP103A-11, SCP110A-2,

AND SCP110A-9.

68. REVISED NOMENCLATURE OF CIRCUITS SCP105A-24 AND

SCP103A-14.

69. ADDED CIRCUITS SCP111A-7, SCP111A-14, SCP111A-15,

SCP111A-16, SCP111A-17, AND SCP110A-1Z.

70. REVISED CABLE TYPE OF CIRCUIT SCP111A-6.

71. REVISED NOMENCLATURE OF CIRCUITS SCP111A-13 AND

SCP110A-1P.

72. DELETED CIRCUITS SCP110A-1D, SCP110A-1M,

SCP110A-1T SCP110A-1V, AND SCP110A-1W(4). (TRAWL

WINCH CKTS).

73. ADDED CIRCUIT SCP110A-3E.

1B

C

D

A

B

C

DRAWING NO. SH REV

D

A

D

REVDRAWING NO.SIZE

USCG APVD: DATE:

SCALE

ABS APVD: DATE:

FSCM CAGE NO.

98042

OF

FSV6-320-01

FSV6-320-01 G

H

1B

1B 39N.T.S.

9B10B11B12B13CB14B15B16B

9B11B12B13B14B15B16B

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONREVSHEET

REVISIONS

B 74. REVISED DESTINATION OF S SCP110A-3P AND

SCP110-3S.

75. REVISED DESTINATION (WAS PRESERVATION ALCOVE).

76. ADDED CABLE TYPE TO CKT SCP110A-75 AND

SCP110A-76.

77. DELETED DAMPER ACTUATOR DETAIL 267-B.

78. DELETED AFT DECK CRANE DETAIL.

79. DELETED DETAIL 283-A, 286-A, AND 286-C.

80. DELETED STOREROOM, SCIENTIFIC, AND CONTROLLED

ENVIRONMENT CONDENSING SYSTEM CONTROLLER WIRING

DIAGRAMS.

81. ADDED SHEET 39 PANELS SCP110A-2 & SCP110A-9.

REV B AUTHORIZATION.

ITEM 1-30, 32-75, AND 77-79 & 81 PER DESIGN DEVELOPMENT.

ITEM 31, 76, AND 80 PER ABS TASK 675573 DATED 11-MAR-2011.

C 1. REVISED INDEX SHEET 38 DESCRIPTION.

2. ADDED LASER OPTICAL PLANKTON COUNTER TO CIRCUIT SCP107A-9

3. ADDED CHEM LAB RECEPTACLE STRIP TO CIRCUIT SCP107A-11

4. REVISED DESCRIPTION OF CIRCUITS SCP107B-2, SCP107B-4, SCP107B-5,

SCP107B-8, SCP107B-8, SCP107B-9

5. DELETED CIRCUITS SCP107B-10, SCP107B-11, SCP107B-12, SCP107B-13,

SCP107B-14.

6. REVISED CIRCUIT BREAKER RATING AND DELETED CIRCUIT FROM SCP107B-24

7. DELETED CIRCUIT SCP105A-3

8. REVISED DESTINATION OF CIRCUITS SCP105A-16, SCP105A-17, SCP105A-18,

SCP105A-19, SCP105A-20, SCP105A-21 AND SCP105A-22.

9. REVISED DESTINATION OF CIRCUITS SCP110A-3A, SCP110A-3B, SCP110A-3C,

SCP110A-3D, SCP110A-3G AND SCP110A-3W.

10. DELETED CIRCUIT SCP110A-3M.

11. REVISED DESTINATION OF CIRCUIT SCP110A-4K FROM SPARE, TO WET LAB

RECEPTACLE -DUPLEX WT.

12. REVISED CIRCUITS SCP110A-7L, SCP110A-7N, FROM SPARE TO DRY LAB

RECEPTACLE STRIP.

13. REVISED CIRCUITS SCP110A-7M, SCP110A-7P FROM SPARE TO HYDROGRAPHIC

LAB RECEPTACLE STRIP.

14. REVISED CIRCUITS SCP110A-8A, SCP110A-8B, SCP110A-8C, SCP110A-8E,

SCP110A-8J FROM CHEM LAB RECEPTACLE STRIP TO SPARE.

15. REVISED CIRCUITS SCP110A-8D, SCP110A-8F, SCP110A-8G, SCP110A-8H,

FROM CHEM LAB RECEPTACLE STRIP TO ET SHOP RECEPTACLE STRIP.

16. REVISED CIRCUITS SCP110A-8K, SCP110A-8L, SCP110A-8N, FROM ET SHOP

RECEPTACLE STRIP TO SPARE.

17. REVISED CABLE TYPE OF CIRCUITS 1GP-1A(CONT3), 1GP-1B(CONT3),

1GP-1C(CONT3) AND 1GP-1D(CONT3) FROM LS2SWU-3, TO LS2SWU-7.

18. DELETED CIRCUITS P103-9.

19. ADDED CIRCUITS K-BTMNSB, AND K-MNSB-4SBUV.

20. REVISED CIRCUIT PMCB-1 AND PMCB-1 CABLE TYPE FROM LSMSCS-19 TO

(6)LSFSGU-4.

21. DELETED CIRCUITS P085 AND P095.

22. REVISED CABLE TYPE OF CIRCUITS P055A AND P065A FROM LSTSGU-14 TO

LSTSGU-23.

23. ADDED CIRCUITS P607-2 AND P608-2.

24. REVISED CABLE TYPE OF CIRCUITS P083(HS) AND P093(HS) FROM LSTSGU-9

TO LSFSGU-9.

25. ADDED CIRCUIT K-BTMNSB

26. ADDED CIRCUIT K-MNSB-4SBUV TO 480V SWITCHBOARD.

27. ADDED CIRCUITS K-PC2-35 AND K-PC1-35.

28. DELETED HEATER CIRCUITS P110-2(HTR), P110-3(HTR), P110-4(HTR),

P110-5(HTR), P110-6(HTR), P110-7(HTR), P110-8(HTR), P110-9(HTR),

P110-10(HTR), AND P110-11(HTR).

29. REVISED CONTROLLER TYPE OF CIRCUITS P610-3 AND P610-8 FROM FSS TO

SS.

30. ADDED FIRE DAMPER CIRCUITS P110-2(C1), P110-4(C1), P110-7(C1), AND

P110-8(C1).

31. ADDED FIRE DAMPER CONTROLLERS TO CIRCUITS P120-1(C1), AND

P119-1(C1)

32. DELETED HEATER CIRCUITS P120-1(HTR_, P120-2(HTR), P120-9(HTR),

P119-1(HTR), P119-2(HTR), P119-8(HTR), P119-9(HTR), AND P119-10(HTR),

33. ADDED FIRE DAMPER CONTROL CIRCUIT P119-9(C1).

CONTINUED ZONE 13C-D THIS SHEET.

34. DELETED HEATER CIRCUITS P109-1A(HTR), P109-1D(HTR), P109-1E(HTR),

P109-1F(HTR), P109-1G(HTR), AND P109-1H(HTR).

35. REVISED FIRE DAMPER CIRCUITS P109-1D(C1), P109-1E(C1), P109-1F(C1),

AND P109-1G(C1).

36. ADDED FIRE DAMPER CIRCUITS P109-1B(C), P109-1F(C), AND P109-1H(C).

37. DELETED CIRCUITS P120-4(C2), P620-4(L), AND P619-12.

38. REVISED CIRCUIT P619-13 CIRCUIT BREAKER SIZE FROM 35AT TO 50AT AND

CABLE SIZE FROM LSTSGU-14 TO LSTSGU-50.

39. DELETED CIRCUIT P609-4, TRASH ROOM S09 DUCT HEATER.

40. ADDED CIRCUITS P412-3M AC05 DUCT PREHEATER EOS, AND P412-3N EOS

DUCT HEATER.

41. REVISED CIRCUIT P412-3D FROM UNIT HEATER LOWER LEVEL, TO AC02 EOS

AHU

42. REVISED CIRCUIT P412-3H FROM PAINT LOCKER CONVECTOR TO AC03 DUCT

PREHEATER.

43. DELETED CIRCUIT P111-2E, WAS PRESERVATION ALCOVE FCU 38.

44. ADDED CIRCUIT P111-2N C02 ROOM EXHAUST FAN E17.

45. ADDED CIRCUIIT P111-2P HAZMAT LKR EXH FAN E09

46. ADDED CIRCUIT P111-2M(C2) FOR C02 PRESSURE SWITCH.

47. ADDED CIRCUIT P111-4S MESSROOM FR 30-35P FCU 29

48. ADDED ITEM NUMBER 228, ALLEN BRADLEY CONTACTOR.

49. REVISED CIRCUIT NAME FROM P405-6(HTR) TO P105-6(C4).

50. REVISED CIRCUIT P415-2 FROM SPARE TO WASTE OIL HTR.

51. ADDED DETAIL 298-B, WASTE OIL HEATER.

52. REVISED CIRCUIT P112-1A FROM HEAT LAMPS TO OCEANOGRAPHIC WINCH ROOM

FAN (S15)

53. REVISED CIRCUIT P112-1B FROM HEAT LAMPS TO OCEANOGRAPHIC WINCH ROOM

FAN (S16)

54. REVISED CIRCUIT P111-4T FROM SPARE TO FORWARD MAST WINCH RECEPTACLE.

55. ADDED ITEMS 229 AUTOMATIC POWER SELECT SWITCH, 230 JUNCTION BOX, AND

231 POWER DISTRIBUTION BLOCK.

56. DELETED RECEPTACLE FROM CIRCUIT P414

57. ADDED CIRCUIT C-AM-1003

58. DELETED CIRCUITS P600/EMERCONTROL, EG(CONT 1), EG(CONT 2).

59. REVISED CIRCUIT NAME FROM EP125 TO EP127

60. REVISED CIRCUIT NAME FROM EP127 TO EP129

61. REVESED NAME OF POWER PANEL EP100.

62. REVISED NAME OF POWER PANEL EP24.

63. ADDED CIRCUIT C-AM-4021

64. ADDED CIRCUIT C-AM-3019

65. REVISED CABLE TYPE OF CIRCUIT EP410(C2) FROM LSMSCU-7 TO LSMSCU-10.

66. REVISED CABLE TYPE OF CIRCUIT EP100-3 FROM LSTSGU-50 TO LSTSGU-400.

67. REVISED CIRCUIT EP405 DESIGNATION FROM ELECTRIC WHISTLE TO SPARE.

68. REVISED CIRCUIT EP413 DESTINATION FROM SUBMERSIBLE PUMP TO SPARE.

69. ADDED CIRCUITS EP129-4, EP129-5, EP129-6, EP129-7, (2) 12VDC

BATTERY'S, AND BATTERY SELECT SWITCH.

70. REVISED CIRCUIT NAME FROM CAM-500-109 TO C-AM-7011.

71. REVISED CIRCUIT NAME FROM CAM 500-18 TOC-AM-2014

72. ADDED CIRCUIT C-AM-2003

73. REVISED CIRCUIT NAME FROM C-AM-500-31 TO C-AM-3014

74. REVISED CIRCUIT NAME FROM C-AM-500-6 TO C-AM-1004

75. DELETED CIRCUIT C-AM-19

76. REVISED CIRCUIT NAME FROM CAM 500-31 TO C-AM-7021

77. REVISED CIRCUIT NAME FROM C-AM-500-142 TO C-AM-2004

78. ADDED CIRCUIT C-AM-3015, C-AM-3012, C-AM-3016, C-AM-3013.

79. DELETE NOTE

80. ADDED CIRCUIT C-AM-8004

81. ADDED CIRCUIT C-AM-3020

82. DELETED CIRCUIT P614-8(B), ANCHORWINDLASS BRAKE

83. REVISED DUCT HEATER FROM 8KW TO 26KW, REVISED CABLE TYPE FROM

LSTSGU-4 TO LSTSGU-9

84. ADDED CIRCUIT P120-1(C2) FOR C02 PRESSURE SWITCH

85. ADDED CIRCUIT P119-1(C2) FOR C02 PRESSURE SWITCH

86. ADDED CIRCUIT DESIGNATION C-AM-4016

87. REVISED CIRCUIT DESTINATION FROM SPARE TO SX93 HULLUNIT

88. ADDED CIRCUIT DESIGNATION C-AM-4017

89. REVISED CIRCUIT P415-7 DESTINATION FROM WET LAB MONORAIL HOIST TO

SPARE

90. REVISED CIRCUIT P415-9 DESTINATION FROM CONTROLLED ENVIRONMENT

CONDENSING SYSTEM CONTROLLER TO SPARE

91. REVISED CIRCUIT P420-5 DESTINATION FROM ELECTRIC GRIDDLE TO

DISHWASHER.

C17

CONTINUED ZONE 16C-D THIS SHEET.

92. REVISED CIRCUIT P420-2 DESTINATION FROM SPARE TO SANITIZING SINK

HEATER

93. REVISED CIRCUIT P222-7 DESTINATION FROM SPARE TO FREQ CONVERTER

#1

94. REVISED CIRCUIT P222-9 DESTINATION FROM SPARE TO PENTAGON MASTER

CONTROL CABINET HEATER

95. REVISED CIRCUIT P222-8 DESTINATION FROM SPARE TO FREQ CONVERTER

#2

96. REVISED CIRCUIT P222-10 DESTINATION FROM SPARE TO FREQ CONVERTER

#2

97. REVISED CIRCUIT P222-16 DESTINATION FROM SPARE TO ANTI FOULING BT

UNIT CTRL PNL

98. ADDED SYMBLE AND ITEM NUMBER CALLOUT TO CIRCUIT EP404-9 AND

EP404-8

99. DELETED ABT FROM CIRCUIT EP128-2

100. DELETED JUNCTION BOX FROM CIRCUIT EP128-8

101. DELETED JUNCTION BOX AND BRANCH CIRCUITS FROM CIRCUIT EP128-12

102. REVISED CIRCUIT EP128-19 DESTINATION FROM SPARE TO SHIPS WHISTLE

103. REVISED CIRCUIT SCP104A DESTINATION FROM SPARE TO ITI BATTERY

CHARGER

104. REVISED DESTINATION OF CIRCUIT SCP107A-15 FROM SPARE TO PILOT

HOUSE RECEPTACLES

105. REVISED DESTINATION OF CIRCUIT SCP107A-16 FROM SPARE TO 04 LEVEL

WEATHER RECEPTACLES

106. REVISED DESTINATION OF CIRCUIT SCP111A-9 FROM FISH FINDING SYSTEM

TO SPARE

107. REVISED DESTINATION OF CIRCUIT SCP111A-10 FROM SCIENTIFIC

COMPUTER SYTEM #1 TO SPARE

108. REVISED DESTINATION OF CIRCUIT SCP111A-12 FROM SCIENTIFIC

COMPUTER SYSTEM #2 TO SPARE

109. REVISED DESTINATION OF CIRCUIT SCP110A-1F FROM DP WIND SENSOR

BATT CHG TO SPARE

110. REVISED DESTINATION OF CIRCUIT SCP110A-12 FROM GPS PWR SUPPLY

TO SPARE

111. REVISED DESTINATION OF CIRCUIT SCP110A-3N FROM 18 KHZ GPT TO

SPARE

112. REVISED DESTINATION OF CIRCUIT SCP110A-3P FROM 38 KHZ GPT TO

SPARE

113. REVISED DESTINATION OF CIRCUIT SCP110A-3R FROM 120 KHZ GPT TO

SPARE

114. REVISED DESTINATION OF CIRCUIT SCP110A-3S FROM 200 KHZ GPT TO

SPARE

115. REVISED DESTINATION OF CIRCUIT SCP110A-7S FROM WATER COLUMN

PROFILER TO CTD DECK UNIT.

116. REVISED DESTINATION OF CIRCUIT SCP110A-2H FROM SPARE TO SX90

TRANSCEIVER

117. REVISED DESTINATION OF CIRCUIT P610-1 FROM AC04 DUCT HEATER TO

SPARE.

118. REVISED DESTINATION OF CIRCUIT P619-16 FROM AC01 AC AHU TO SPARE

119. ADDED CIRCUIT P119-10(C1) CO2 PRESSURE SWITCH

120. REVISED DESTINATION OF CIRCUIT P609-1B FROM AC04 LAB AREA AC AHU

TO SPARE

121. REVISED DESTINATION OF CIRCUIT P609-7 FROM AC04 PREHEATER TO AIR

HANDLING UNIT AC04

122. REVISED DESTINATION OF CIRCUIT P609-8 FROM AC01 DUCT PREHEATER

01 LEVEL FAN ROOM TO AIR HANDLING UNIT AC01

123. ADDED MMC PART NUMBER TO ITEM NUMBER 88

124. DELETED ITEM NUMBERS 111 AND 113

125. REVISED QTY OF ITEM 108 FROM 24 TO 28

126. REVISED QTY OF ITEM 102 FROM 6 TO 8

127. ADDED ITEM NUMBER 232 (PUSHBUTTON), 233 "START NAMEPLATE", 234

"STOP NAME PLATE", 235 "LIGHT", AND 236 "30A DUAL BATTERY

CHARGER"

128. REVISE QTY OF ITEM 118 FROM 3 TO 5

129. ADDED SHEET 4A AND ITEM NUMBERS 237 AND 238.

130. DELETED CIRCUITS P089 AND P099

131. REVISED DESTINATION OF CKT P625 FROM SPARE TO TRAWL HPU

132. ADDED START STOP PUSH BUTTONS TO AND CIRCUITS EP412(C1) AND

EP412(C2).

133. REVISED FIND NUMBER OF BATTER CHARGER FROM 165 TO 236.

C25

4A

CONTINUED ZONE 9D-D SHEET 1D.

C

D

A

B

C

DRAWING NO. SH REV

D

A

D

REVDRAWING NO.SIZE

USCG APVD: DATE:

SCALE

ABS APVD: DATE:

FSCM CAGE NO.

98042

OF

FSV6-320-01

FSV6-320-01 G

H

1C

1C 39N.T.S.

9C10C11C12C13C14C15C16C

9C11C12C13C14C15C16C

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONREV

REVISIONS

C134. REVISED DESTINATION OF CKT CP24-5 FROM 600VAC SWBD BUS A&B CONTROL

POWER TO WATERTIGHT DOORS CTRL CABINET (1)

135. REVISED DESTINATION OF CKT CP24-6 FROM TACHTROL 30 SHAFT RPM TO

EMERGENCY GENERATOR

136. REVISED DESTINATION OF CKT CP24-8 FROM WATERTIGHT DOORS TO WATERTIGHT

DOORS CTRL CABINET (2)

137. REVISED DESTINATION OF CKT CP24-10 FROM 600VAC WBD BUS C&D CONTROL

POWER TO SPARE

138. REVISED DESTINATION OF CKT P604-7 FROM FISH MACERATOR TO SPARE

139. DELETED CIRCUITS CAM 500-109 AND CAM 500-18

140. DELETED CIRCUIT P2407-11H

141. REVISED DESTINATINO OF CKT P614-4 FROM AFT DECK CRANE SKID TO SPARE

142. REVISED DESTINATION OF CKT P614-7 FROM AFT A FRAME HPU TO SPARE

143. REVISED CONTROLER TYPE OF CIRCUITS P610-2 AND P610-4 FROM HOA TO

FSS

144. REVISED DESTINATION OF CIRCUITS P112-1F AND P112-1G FROM SPARE TO

SH&T HEAT LAMPS

145. REVISED DESTINATION OF CKT P419-1 FROM RESCUE BOAT BATTERY CHARGER

TO SPARE

146. REVISED DESTINATION OF CKT P419-3 FROM 910KW GEN NO 3 JACKET WATER

HTRS TO SPARE

147. REVISED DESTINATION OF CKT P419-5 FROM GEN NO 2 JACKET WATER HTRS TO

SPARE

148. REVISED DESTINATION OF CKT P419-6 FROM GEN NO 4 JACKET WATER HTRS TO

SPARE

149. REVISED DESTINATION OF CKT P419-8 FROM GEN NO 1 JACKET WATER HTRS TO

SPARE

150. REVISED DESTINATION OF CKT P419-12 FROM SPARE TO WORK BOAT DAVIT HPU

151. REVISED DESTINATION OF CKT P103-9 FROM A/C UNIT #2 TO SPARE

152. REVISED DESTINATION OF CKT P103-12 FROM A/C UNIT #1 TO SPARE

153. ADDED CIRCUITS K-PC2-35 (STBD PRPLN MOTOR #2) AND K-PC1-35 (STBD

PRPLN MOTOR #1)

154. REVISED DESTINATINO OF CKTS P415-4, P415-5, P415-11, AND P415-12

FROM SPARE TO JACKET WATER HEATERS.

155. REVISED DESTINATION OF CKT P415-5 FROM SPARE TO OILY WATER SEPERATOR.

156. REVISED DESTINATION OF CKT P420-11 FROM GARBAGE GRINDER TO SPARE.

157. ADDED TRANSFORMER FIND NUMBER 238 TO CKT P120-1A

158. ADDED TRANSFORMER, FIND NUMBER 237, TO CKTS P120-1E AND P120-1F

159. REVISED DESTINATION OF CIRCUIT EP122-A1 FROM DAU#2 TO SPARE

160. REVISED DESTINATION OF CIRCUIT EP122-A7 FROM DAU#1 TO SPARE

161. REVISED DESTINATION OF CIRCUIT EP122-A9 FROM DAU#3 TO SPARE

162. REVISED DESTINATION OF CIRCUIT EP122-A11 FROM DAU#5 TO SPARE

163. REVISED DESTINATION OF CIRCUIT EP122-A13 FROM DAU#7 TO SPARE

164. REVISED DESTINATION OF CIRCUIT EP122-A8 FROM DAU#4 TO SPARE

165. REVISED DESTINATION OF CIRCUIT EP122-A10 FROM DAU#6 TO SPARE

166. REVISED DESTINATION OF CIRCUIT EP122-A12 FROMDAU#8 TO SPARE

167. DELETED CKT CAM 500-176

168. DELETED JUNCTION BOX AND BRANCH CIRCUITS FROM CKT EP128-3

169. REVISED CKT EP128-3 CABLE TYPE FROM LSDSGU-4 TO LSDSGU-9 AND

CIRCUIT BREAKER RATING FROM 15AT TO 30AT

170. REVISED DESTINATION OF CKT SCP107A-8 FROM SCIENTIFIC SEAWATER TO

SCIENTIFIC SEAWATER THERMOSALINOGRAPH.

171. REVISED CKTS SCP110A-2 AND SCP110A-9 CIRCUIT BREAKER RATING FROM

50AT TO 100AT, AND REVISED CABLE SIZE FROM LSTSGU-23 TO LSTSGU-75.

172. REVISED CABLE TYPE FROM LSTSGU-23 TO LSTSGU-75 OF CKTS SCP110A-2

AND SCP110A-9

173. ADDED SHEET 1C

174. ADDED CABLE TYPE LSDSGU-4 TO CKT P103-16

175. ADDED SHAFT BRAKE INTERLOCK CIRCUIT K-PC(1-2)-35.

176. ADDED GENERAL NOTE 27.

1C

SHEET

REV C AUTHORIZATION.

ITEM 1-174 PER DESIGN DEVELOPMENT.

APVDDATE

12/03/12 TT

C

D 1. ADDED ITEM #239, 5KVA TRANSFORMER

2. ADDED LATHE TRANSFORMER, ITEM #239.

3. ADDED SIDE SAMPLING STATION RECEPTACLE AND CKT EP404-7

4. REVISED QTY OF FIND# 195 FROM 2 TO 3

5. REVISED CKTS SCP110A-1E FROM SM2000 MULTIBEAM ECHO SOUNDER

TO SPARE

6. REVISED CKTS SCP110A-1L FROM WINCH REMOTE CONTROLS 24VDC

POWER SUPPLY TO SPARE

7. REVISED CKT SCP110A-1H FROM SCIENTIFIC DGPS TO SPARE.

8. REVISED CKT SCP110A-1K FROM NETWORK SWITCH TO SPARE

9. REVISED CKT SCP110A-1S FROM NETWORK SWITCH TO SPARE

10. REVISED CKT SCP110A-3U FROM ETHERNET SWITCH TO SPARE

11. REVISED CKT SCP110A-4L FROM SPARE TO FUME HOOD WET LAB

12. REVISED CKT SCP110A-4L FROM SPARE TO FUME HOOD CHEM LAB

4A

REV D AUTHORIZATION.

ITEM 1-12 PER DESIGN DEVELOPMENT.

E 1. REVISED CKT SCP111A-18 FROM SPARE TO CCT POWER SUPPLY

2. REVISED CKT SCP107A-11 FROM CHEM LAB RECEPTACLE STRIP TO

SPARE.

3. ADDED CKT BATT-4.3UPS, AND UPS DC BATTERY CABINET

4. ADDED FIND NUMBER 241 TO 18KVA UPS DC BATTERY CABINET

5. ADDED ITEM NUMBERS 240 THRU 242 TO EQUIPMENT LIST.

6. REVISED DESCRIPTION OF TRANSFORMER AND TRANSFORMER IRON CORE

WITH ELECTROSTATIC SHIELD

7. DELETED CKT CP24-10

8. DELETED CKT CP24-5

9. REVISED CKTS WAS P419-3 AND P419-3A, IS P415-11 AND P41511A.

10. REVISED CKTS WAS P419-8 AND P419-8A, IS P415-4 AND P415-4A.

11. REVISED CKTS WAS P419-5 AND P419-5A, IS P415-5 AND P415-5A.

12. REVISED CKTS WAS P419-6 AND P419-6A, IS P415-12 AND

P415-12A.

13. REVISED XFMR P602, P601, P422, AND P403 DESCRIPTION FROM XFMR

TO ISLN XFMR AND REVISED SYMBOL

14. ADDED ITEM NUMBERS 244 AND 245.

15. REVISED CKT SCP108A MOVED CKT DESTINATION TO SHEET 39

16. ADDED DISTRIBUTION PANEL SCP108A

17. REVISED XFMR EP400-2 AND EP400-1 DESCRIPTION FROM XFMR TO

ISLN XFMR AND REVISED XFMR SYMBOL

18. REVISED DESCRIPTION OF PHASE SHIFTING XFMR

19. REVISED SYMBOL OF XFMR P617, SCP111-1, AND SCP110-1.

20. REVISED DESCRIPTION OF WINCH POWER PANELS P415-A AND P415-B

21. REVISED MOTOR HP RATING OF GALLEY FAN E04, DIVER LOCKER FAN

S10, GALLEY FAN S12, TRANSDUCER RM SUPPLY FAN S08, 2ND/MAIN

DK FWD FAN S11.

22. REVISED LOAD RATING OF DUCT HEATERS DH-15, DH-10, DH-01,

DH-11, DH14, AND DH-04.

23. REVISED MOTOR HP RATING OF WET LAB SCI READY ROOM FAN E08,

TRASH RM EXH FAN E15, EMER. GEN RM/DECK LKR FAN E03,

SCIENTIFIC STORES SUPPLY FAN S01.

24. REVISED LOAD RATING OF DUCT HEATERS DH-5, DH-6, AND DH-12.

25. REVISED LOAD RATING OF AIR HANDLING UNIT AC01.

26. REVISED CIRCUIT BREAKER RATING FOR CIRCUITS P609-2G, P609-3,

AND P609-5.

27. REVISED SUPPLY FAN S14 MOTOR FROM SINGLE SPEED TO 2 SPEED.

28. REVISED CABLE SIZE OF CKT P609-5 FROM LSTSGU-9 TO LSTSGU-23.

29. REVISED CIRCUIT BREAKER RATING FOR CIRCUITS P610-14, P616-1,

P616-3, P616-6.

30. REVISED SYMBOL OF HVAC XFMR P412-1, P412-2, P411-1, P411-2,

P411-3, AND P411-4.

31. REVISED LOAD RATING OF CKTS P412-4, P412-8, P412-10, P412-3J,

P412-3D, P412-3H, P412-3K, P412-3M, P411-5, P411-6, P411-8, P411-10.

32. REVISED LOAD RATING OF CKTS P112-1C, AND P112-1E.

33. REVISED CKT BREAKER RATING OF CKTS P112-1E

4A

E 34. REVISED LOAD RATING OF CKTS P111-1E, P111-1G, P111-1D,

P111-2L, P111-2N, AND P111-2P.

35. REVISED DESCRIPTION OF CIRCUITS P111-3G, AND P111-3D.

36. REVISED MOTOR LOAD RADING OF CKTS P111-4R AND P111-4N

37. REVISED SYMBOL OF XFMR P120-1E, P120-1A, P120-1F, AND

P420-1.

38. REVISED DESCRIPTION OF XFMR P120-1A, P120-1E, AND P120-1F.

39. REVISED DESTINATION OF CKT EP122

40. REVISED DESTINATION OF CKT SCP104A-12

41. REVISED REF OF CKT SCP103A-16

42. REVISED VOLTAGE RATING OF PANEL SCP110A

43. REVISED SHEET DESCRIPTION

44. REVISED VOLTAGE RATING OF POWER PANELS SCP111A AND

SCP110A-1

45. REVISED SHEET DESCRIPTION

46. REVISED VOLTAGE RATING OF POWER PANEL SCP110A-3

47. REVISED SHEET DESCRIPTION

48. REVISED VOLTAGE RATING OF POWER PANELS SCP110A-4 AND

SCP110A-5

49. REVISED VOLTAGE RATING OF POWER PANELS SCP110A-6, AND

SCP110A-7

50. REVISED VOLTAGE RATING OF POWER PANEL SCP110A-8.

51. REVISED SHEET DESCRIPTION

52. REVISED VOLTAGE RATING OF POWER PANELS SCP110A-2, AND

SCP110A-9

53. REVISED DESCRIPTION OF ITEM NO. 118

54. ADDED ITEM NO. 246

55. REVISED DESCRIPTION OF CKT P604-5

56. REVISED BREAKER RATING OF CKTS P608-7, P608-8, P608-9,

P607-7 P607-8, P607-9.

57. REVISED CTRL TYPE OF CKT P608-9 FROM SS TO HOA

58. ADDED CKTS P108-3(C1), P108-4(C1), P107-3(C2) P107-4(C1)

59. ADDED UV SYMBOL TO CKT P614-8.

60. DELETED "REF 19" CKT FROM ATS.

61. REVISED CKT EP404-7 CABLE TYPE FROM LSTSGU-4 TO LSTSGU-9.

62. REVISED CKT EP122-A3 FROM CHIEF ENG'R NO.1 UPS TO SPARE

63. REVISED CKT EP122-A5 FRM CHIEF ENG'R NO 2 UPS TO SPARE.

64. REVISED CKT EP122-A15 FROM MCC AMS/PWR SUPPLY TO SPARE

65. REVISED CKT EP122-A18 FROM DEPTH SOUNDER DISPLAY TO SPARE

66. REVISED CKT EP122-A20 FROM BILGE VLV CONT (MCC) TO SPARE

67. REVISED LOCATION OF DUCT HEATER DH-04.

68. REVISED CKT P420-3 FROM STEAMER TO SPARE

69. REVISED CKT P420-9 FROM STEAM KETTLE TO SPARE

70. REVISED CKT P222-18 FROM SPARE TO STEAM KETTLE

71. REVISED CKT P222-22 FROM BLANK TO STEAMER.

72. REVISED CABLE TYPE OF CKT K-MNSB-4SBUV

73. REVISED CKT P418 MOTOR LOAD RATING

74. REVISED CKT P414 LOCATION

75. ADDED CKT P413(C1)

76. REVISED CKT P413 MOTOR LOAD RATING

77. REVISED KW RATING OF CKT P417

78. REVISED KW RATING OF CKTS EP410, EP408, EP407, EP415.,

EP121, EP129

79. REVISED CKT EP411 FROM DIVERS AIR COMPRESSOR TO SPARE.

80. DELETED CKT EP24-4

81. REVISED XFMR SCP110-1 LOCATION

82. REVISED KW RATING FOR CKTS P604-1, P604-2, P604-5, P604-2,

P604-4, P604-6, P604-10, P603-4, P603-5, P603-6.

83. REVISED KW RATING FOR CKTS P608-2, P608-4, P607-2, P607-3,

P607-4, P607-11.

84. DELETED CKTS P108-3(C), P108-4(C), P107-3(C), P107-4(C).

P108-4(C), P107-3(C1), P107-3(C1)

85. REVISED LOAD RATING FOR VARIOUS CKTS

86. REVISED NOMENCLATURE OF PANELS P415-A AND P415-B

87. REVISED LOAD RATING OF P614-5.

88. REVISED LOAD RATING OF P616-5 AND P616-4

89. REVISED CKT BREAKER RATING OF P609-3

90. ADDED KW RATING TO P412-7

91. REVISED LOAD RATING OF VARIOUS CKTS ON PNL P103

92. REVISED CKT P103-3, AND P103-7 BREAKER RATING.

93. REVISED NOMENCLATURE OF CKT P103-17, P103-4, P103-8.

94. REVISED VARIOUS LOAD RATINGS ON PNL P415 AND P415-1

95. REVISED BREAKER SIZE OF CKTS P415-3, P415-4, P415-8,

P415-10, P415-11, AND P415-12.

4A

CONTINUED ZN 16C-D, THIS SHEET

CONTINUED ZN 11D-D, SHEET 1D

C

D

A

B

C

DRAWING NO. SH REV

D

A

D

REVDRAWING NO.SIZE

USCG APVD: DATE:

SCALE

ABS APVD: DATE:

FSCM CAGE NO.

98042

OF

FSV6-320-01

FSV6-320-01 G

H

1D

1D 39N.T.S.

9D10D11D12D13D14D15D16D

9D11D12D13D14D15D16D

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONREV

REVISIONS

96. ADDED SHEET 1D

97. REVISED CABLE TYPE OF CKTS P415-8 AND P415-10

98. REVISED CKT BREAKER SIZE AND NEMENCLATURE OF CKTS P222-7, P222-8,

P222-10

99. ADDED LOAD KW RATING TO VARIOUS CKTS

100. REVISED CKT EP404-7 FROM SIDE SAMPLIN STATION RECEPTACLE TO SPARE

101. REVISED CKT EP404-9 FROM SUMP PUMP RCPT TO SPARE

102. REVISED CKT EP404-8 FROM ISO VAN SITE RCPT TO SPARE

103. REVISED CKT EP122-A16 FROM MCC PWR SUPPLY TO MCC ETHERNET PWR

SUPPLY

104. REVISED CKT SCP111A-7 FROM MOBILE EARTH STATION TO INMARSAT C FURUNO

FALCOM 15

105. REVISED CKT SCP110A-1A FROM SCIENTIFIC METEOROLOGICAL SYSTEM TO WIND

TRACKER SYSTEM

106. ADDED 4 BLANKS TO PANEL EP100

107. REVISED CABLE TYPE OF CKT CP24-5

108. ADDED CKT P614-15 AND BLANK SPACE TO PANEL P614

109. REVISED CKT P614-2 FROM SPARE TO BLANK

110. REVISED CTRL TYPE OF CKTS P610-2, P610-6, P610-8.

111. REVISED CKT OF EOS DUCT HEATER (DH-03) FROM P412-3N TO P412-3L

112. REVISED CKTS P112-1F AND P112-1G FROM SH&t HEAT LAMPS TO SPARE.

113. REVISED CKT P112-2D FROM SH&T HEAT LAMPS TO SPARE

114. REVISED CKT BREAK RATING OF CKT P112-2S FROM 20AT TO 15AT.

115. ADDED 2 BLANK PANEL LOCATIONS TO PANEL P111-2

116. REMOVED 2 BLANK PANEL LOCATIONS FROM PANEL P412

117. REVISED DESCRIPTION OF CKT P111-4T.

118. REVISED CABLE TYPE AND CKT BREAKER RATING OF CKTS P111-3N, P111-3M,

P111-3P, P111-3S, P111-3A

119. REVISED BREAKER RATING OF CKT P416-9 FROM 10AT TO 15AT.

120. REVISED CKT P416-3 FROM SCIENTIFIC VACUUM PMP TO SPARE

121. ADDED CKTS P419-15, AND P419-16.

122. REMOVED 5 BLANKS FROM PANEL P406

123. REMOVED 1 BLANK FROM PANEL P405

124. REVISED CABLE TYPE OF CKTS P415-4, P415-5, P415-11, AND P415-12

FROM LSDSGU-9 TO LSTSGU-4

125. REVISED CKT P120-1V BREAKER SIZE FROM 15AT TO 20AT

126. REVISED BREAKER SIZE OF CKT P222-13 FROM 15AT 2P TO 20AT 1P.

127. REVISED BREAKER SIZE OF CKT P222-14 FROM 1P TO 2P

128. REVISED CKT P222-16 FROM ANTI FOULING BT UNIT CTRL PNL TO SPARE

129. REVISED CKT P222-20 FROM SPARE TO ANTI FOULING BT UNIT CTRL PNL PORT.

130. REVISED DESCRIPTION OF CKT P222-14

131. DELETED 3 BLANKS FROM PNL SCP104A.

132. REVISED CKT SCP104A-28 BREAKER SIZE FROM 1P TO 2P

133. ADDED BLANK TO PANEL SCP107B

134. DELETED 12 BLANK LOCATIONS FROM PANEL SCP103A

135. DELETED 2 BLANK LOCATIONS FROM PANEL SCP106A

136. ADDED 6 BLANK LOCATIONS TO PANEL SCP111A

137. ADDED 2 BLANK LOCATIONS TO PANEL SCP110A-1

138. ADDED 2 BLANK LOCATIONS TO PANEL SCP110A-3

139. ADDED 6 BLANK LOCATIONS TO PANEL SCP110A-4

140. ADDED 4 BLANK LOCATIONS TO PANEL SCP110A-5

141. ADDED 6 BLANK LOCATIONS TO PANEL SCP110A-6

142. ADDED 4 BLANK LOCATIONS TO PANEL SCP110A-7

143. ADDED 2 BLANK LOCATIONS TO PANEL SCP110A-2

144. ADDED 2 BLANK LOCATIONS TO PANEL SCP110A-9

145. REVISED LOCATION OF XFMR SCP110-1

146. ADDED KW RATING TO CKT P103-2 AND P103-5.

147. ADDED KW RATING TO CKT P103-6, P123F-13, AND P123F-15.

148. ADDED KW RATING TO CKT EP416, EP123, EP417, EG(HTR).

149. REVISED CKT P608-4(L), AND P607-4(L), BREAKER RATING FROM 15AT TO

50AT, AND CABLE TYPE FROM LSTSGU-4 TO LSTSGU-14.

150. ADDED KW RATINGS TO PANEL P415-A, AND P415-B.

151. REVISED MOTOR RATING OF CKTS P614-9, AND P614-10.

152. ADDED KW RATINGS TO CKTS P112-1H AND P112-1J.

153. ADDED KW RATING TO CKT P111-2G

154. ADDED KW RATING TO CKTS P111-3F, AND P111-3J.

155. REVISED CKT P111-4T CIRCUIT BREAKER RATING

156. ADDED KW RATING TO CKTS P419-4, P103-15, P103-14, P416-4, P416-7,

P416-8, P416-9, AND P416-10.

157. REVISED CKT P103-9 FROM SPARE TO GEN S.W. CUTOUT VALVES CONTROL.

158. ADDED KW RATING TO PANELS P406, P405, AND P415.

159. REVISED KW RATING OF CKT P415-3.

160. ADDED KW RATINGS TO CKTS P420-5, P420-2, P420-6, P120-1A, P120-1C,

P120-1L, P120-1T, P222-1, P222-3, P222-5, P222-9, P222-11, P222-2, P222-6, P222-12, P222-14, P222-18, P222-20, AND P222-22.

161. REVISED KW RATING OF CKT P420-6, AND P222-12.

SHEET APVDDATE

E162. ADDED KW RATING TO CKTS EP122-A2, EP122-A4, EP128-1,

EP128-3, EP128-5, EP128-13, EP128-15, EP128-17, EP128-19,

EP128-20, EP128-18, EP128-14, AND EP128-2.

163. ADDED KW RATING TO CKTS SCP104A-11, SCP104A-13, AND

SCP104A-15.

164. ADDED KW RATINGS TO CKTS SCP107A-9, AND SCP107A-8.

165. ADDED KW RATINGS TO CKTS SCP105A-23, SCP105A-24, SCP103A-11,

SCP103A-13.

166. REVISED CKTS ON PANEL SCP106A FROM STATEROOMS TO STATEROOM

RCPT'S.

167. REVISED CKT CP24-15 FROM ALARM PANEL TO STEERING ALARM PANEL

168. REVISED LOCATION OF XFMR P623 FROM ENG STOREROOM TO AMR

169. REVISED CKT SCP104A-11 FROM NET SOUNDER BATTERY CHARGER TO

SPARE

170. REVISED LOCATION OF XFMR P623 FROM ENG STORE TO AMR

171. REVISED SYMBOL OF NODE XFMR P411-6, P411-10, P411-11,

P411-12 FROM ISOLATION TO IRON CORE WITH ELECTROSTATIC SHIELD,

ISOLATION.

172. REVISED WORDING OF GENERAL NOTE 24.

173. ADDED REMARKS TO ITEM NUMBERS

5,6,10,11,14,15,16,17,18,19,20,21,AND 22

174. REVISED MMC PART NUMBER OF ITEM NUMBERS 10 AND 11.

175. REVISED QTY OF ITEM NUMBERS 89,91.

176. REVISED DESCRIPTION OF ITEM NO. 102.

177. DELETED REMARK FROM ITEM NO. 112

178. REVISED AMP RATING, AND ADDED REMARK TO ITEM NO. 163.

179. REVISED ITEM NO. 180 AND 183 REMARKS

180. REVISED PART NO. AND ADDED REMARKS TO ITEM NO. 211 AND 222.

181. ADDED REMARKS AND SYMBOL TO ITEM NO. 229.

182. REVISED DESCRIPTION AND MANUFACTURER OF ITEM NO. 226.

183. REVISED DESCRIPTION OF ITEM NO. 184.

184. REVISED DESCRIPTION, SPEC NO., MANUFACTURER, AND PART NO., OF

ITEM NO. 244 AND 245

185. ADDED ITEM NO 247.

186. DELETED CKTS P415-11A, P415-4A, P415-5A, P415-12A.

187. REVISED CABLE TYPE OF CKTS P415-11 P415-4, P415-5, P415-12

FROM LSDSGU-9 TO LSTSGU-4.

188. REVISED ITEM NO. OF CKT EP416-1 BATTERY CABINET, EP24-2

BATTERY SELECTOR SWITCH, EP417-1 BATTERY CABINET, EP129-4

BATTERY SELECT SWITCH.

189. ADDED AMP RATINGS TO PANEL EP24

190. REVISED DESCRIPTION OF ITEM NO 229.

191. REVISED DETAIL CALLOUT OF CKT EG(C02PS) FROM 283-A TO 283-B.

192. REVISED QTY OF PART NO. 232 FROM 4 TO 2.

193. REVISED CKT BREAKER RATING OF SCP108.

194. REVISED CABLE TYPE AND DESCRIPTION OF CKT SCP108A.

195. REVISED DESCRIPTION OF CKTS SCP110A AND SCP111A.

196. REVISED CKT BREAKER POLE RATING OF SCP111-1

197. REVISED KW RATING OF CKT P608-3(L)

198. REVISED CKT BREAKER SIZE OF CKT P610-14 FROM 15AT TO 35AT

199. REVISED CKT BREAKER SIZE OF CKT P609-5 FROM 30AT TO 50AT

200. REVISED CKT BREAKER SIZE FO CKT P609-8 FROM 60AT TO 20AT

201. REVISED CKT BREAKER RATING OF CKTS P412-9, P412-3A, P412-3E,

P411-7, AND P411-10.

202. REVISED CKT BREAKER RATING OF CKTS P112-2A, P112-2B,

P112-2C, P112-2H, AND P112-2L.

203. REVISED CKT BREAKER RATING OF CKTS P111-1F, AND P111-2C.

204. REVISED CKT BREAKER RATING OF CKTS P111-3A, P111-3M,

P111-3N, P111-3P P111-3S, P111-4A, P111-4F, P111-4N, P111-4R.

205. REVISED CKT BREAKER RATING OF CKTS P419-4, P103-6, AND

P416-10.

206. REVISED CKT BREAKER RATING OF CKTS P415-3, P415-4, P415-8,

P415-10, P415-11, AND P415-12.

207. DELETED CKTS P415-4(A), P415-5(A), P415-11(A), AND P415-12(A).

208. REVISED CABLE TYPE OF CKTS P415-4, P415-5, P415-11, AND

P415-12.

209. REVISED DESCRIPTION OF ITEM NO. 239, LATHE XFMR.

210. ADDED KW RATING TO CKT P415-10.

211. REVISED C.B. RATING OF CKTS P420-8, P120-1U, P222-12.

212. REVISED KW RATING OF CKTS P222-18, P222-17.

213. REVISED DESCRIPTION OF CKT P222-5.

214. REVISED SYMBOL OF CKTS EP404-1, EP404-2, EP404-3, EP404-4,

AND EP404-5.

215. REVISED C.B. RATING OF CKTS EP122-A2, EP122-A4, EP128-2,

EP128-8, EP128-15, EP128-17, EP128-19.

4A

CONTINUED ZN 14D-D, THIS SHEET

8/13/13 CE

SHEETREV

E

CONTINUED ZN 14D-D, THIS SHEET

216. REVISED CABLE TYPE AND KW RATING OF CKT

EP128-8.

217. REVISED DESCRIPTION OF CKT EP128-3, EP128-6,

EP128-4, EP128-7, EP122-A19, AND EP128-9.

218. REVISED DESCRIPTION OF CKT SCP104A-15

219. REVISED GENERAL NOTE

220. REVISED NOTE

221. REVISED CKT SCP111A-13 DESCRIPTION

222. REVISED NOTE

223. REVISED DESCRIPTION OF CKT SCP110A-3J

224. REVISED GENERAL NOTE

E

REV E AUTHORIZATION.

ITEM 1-224 PER DESIGN DEVELOPMENT.

APVDDATE

8/13/13 DK

1. REVISED CKT NAME FROM EP416-1 TO EP24-5

2. REVISED CKT NAME FROM EP417-1 TO EP24-4

3. REVISED PANEL NAME FROM EP24 TO CP24

4. DELETED CKT P120-1(C2), P119-1(C3),

P119-2(C2), P119-2(C2), p119-10(C1).

5. DELETED DETAIL 283-B

6. REVISED CKT CP24-6 FROM SPARE TO EMER SWBD

7. REVISED CKT CP24-9 FROM SPARE TO AUTOPILOT

8. REVISED CKT CP24-5 FROM SATERTIGHT DOORS

CTRL CABINET TO SPARE

9. ADDED CKTS P125-HPU-E-STOP, AND

P125-HPU-E-STOP(1)

10. REVISED CKT EG(C02PS) FROM C02 PRESSURE

SWITCH OR C02 CONT PANEL.

11. ADDED 4 BLANK LOCATIONS TO PNL CP24

12. ADDED CKT P604-5, AND FIND NUMBER 210 TO

CKT P604-5

13. REVISED CKT P415-A3 AND P415-B3 CABLE TYPE

FROM LSTSGU-100 TO LSTSGU-150

14. REVISED CKT P614-3 FROM SPARE TO

OCEANOGRAPHIC PMP#1

15. REVISED CKT P614-4 FROM SPARE TO

OCEANOGRAPHIC PMP#2

16. REVISED CKT P616-10 FROM PASSAGE 1-7-1 TO

DRY STORES 1-7-3 DUCT HEATER.

17. REVISED CKT P111-1M BREAKER RATING FROM

15AT TO 20AT

18. REVISED CKT P111-3J AND P111-3F FROM HEAT

LAMPS TO SPARE

19. REVISED CKT P111-4T FROM FORWARD MAST

RECEPTACLE TO SPARE

20. REVISED VARIOUS CABLE TYPES OF CKT

P103-18(C1-3), C2-3, C3-3, AND C4-3.

21. DELETED CKTS P420-13 AND P420-14

22. REVISED CKT SCP104A-13 FROM ITI BATTERY

CHARGER TO SPARE

23. REVISED CKT SCP104A-15 FROM DIGITAL SCALE TO

SPARE

24. REVISED CKT SCP107A-9 FROM LASTER OPTICAL

PLANKTON COUNTER TO SPARE

25. REVISED CKT SCP107A-15 FROM PILOT HOUSE

RECEPTACLES TO SPARE

26. REVISED CKT SCP107A-16 FROM 04 LEVEL

WEATHER RECEPTACLES TO SPARE

27. REVISED CKT SCP103A-3 FROM SPARE TO

FWD/STBD SCC RCPT

28. REVISED CKT SCP103A-2 FROM SPARE TO PH

RCPTS

29. REVISED CKT SCP103A-4 FROM SPARE TO

CONSOLE FWD/STBD CONT

30. REVISED CKT SCP103A-8 FROM BRIDGE RCPT TO

SPARE

31. REVISED CKT SCP103A-14, SCP103A-18,

SCP103A-20, FROM BRIDGE EQUIPMENT RACK RCPT

TO SPARE

F

C

D

A

B

C

DRAWING NO. SH REV

D

A

D

REVDRAWING NO.SIZE

USCG APVD: DATE:

SCALE

ABS APVD: DATE:

FSCM CAGE NO.

98042

OF

FSV6-320-01

FSV6-320-01 G

H

1E

1E 39N.T.S.

9D10D11D12D13D14D15D16D

9D11D12D13D14D15D16D

DESCRIPTIONSHEETREV

REVISIONS

DESCRIPTIONSHEETREV

REVISIONS

32. ADDED SHEET 1E TO INDEX

33. REVISED CKT SCP111A-1 FROM VAISALA BAROMETER TO BLANK

34. REVISED CKT SCP111A-18 FROM CCTV POWER SUPPLY TO SPARE

35. REVISED CKT SCP110A-1J FROM SCC TO SPARE

36. REVISED CKT SCP110A-1R, SCP110A-1X FROM EQUIPMENT RACK TO SPARE

37. ADDED 2 BLANK LOCATIONS TO SCP110A-1

38. REVISED SCP110A-4M FROM WET LAB FUME HOOD TO SPARE

39. REVISED SCP110A-5T FROM HEATING AFT WORK DECK CONTROL STATION TO

SPARE

40. REVISED SCP110A-5V FROM SPARE TO ICE MACHINE

41. REVISED SCP110A-6Z FROM NETWORK SWITCH IMU ROOM TO SPARE

42. REVISED SCP110A-7L RECEPTACLE STRIP FROM DRY LAB TO SCI EQUIPMENT RM

43. REVISED SCP110A-7D FROM CHEM LAB RECEPTACLE STRIP TO SCI SEAWATER

THERMO SALINOGRAPH

44. REVISED SCP110A-7M AND SCP110A-7P HYDROGRAPHIC LAB RECEPTACLE FROM

RECEPTACLE STRIP TO DUPLEX W.T.

45. REVISED SCP110A-7W FROM SPARE TO CCTV RCPTS CHEM LAB, FISH LAB, WET

LAB.

46. REVISED SCP110A-2A FROM CB0 TO SPARE

47. REVISED SCP110A-9G FROM CB3 TO SPARE

48. REVISED SCP110A-9J FROM SPARE TO RAPID FREEZER.

49. ADDED ITEM NO. 248 THRU 253

50. REVISED DESCRIPTION OF PANELS EP100 AND EP24

51. REVISED MOTOR SYMBOL FOR CKTS P610-2, AND P610-4.

52. REVISED DESCRIPTION OF CKTS P616-5, P616-4, AND P616-10..

53. REVISED CKT P609-10 FROM SPARE TO J. BOX FOR FUTURE DIVERS AIR

SYSTEM.

54. REVISED P412-4 CKT BREAKER FROM 15AT TO 100AT.

55. REVISED P412-4 FROM UNIT HEATER (UH-1) TO POWER PANEL P412-4

56. ADDED UNIT HEATER (UH-1) TO CKT P412-8A.

57. ADDED POWER PANEL P412-4

58. REVISED DESCRIPTION OF CKTS P112-1H AND P112-1J

59. REVISED DESCRIPTION OF CKTS P112-2N AND P112-2M

60. REVISED DESCRIPTION OF CKT P111-2D

61. REVISED CABLE TYPE OF CKT P419-15, P419-16, P103-9, P103-15,

P103-14, P103-16.

62. REVISED BREAKER RATING OF CKTS P120-1D, P222-18, AND P222-19.

63. REVISED CABLE TYPE OF CKTS P120-1D, P222-19, P222-20, AND P222-18.

64. REVISED DESCRIPTION OF CKT P420-4.

65. REVISED CKT EP404-7 FROM SPARE TO S-BAND RADAR.

66. ADDED PANEL EP128A

67. REVISED CKT SCP107A-8 FROM THERMOSALINOGRAPH TO CHEM LAB RCPT

68. REVISED CKT SCP105A-24 FROM INERTIAL REF SYS PWR SUPPLY TO SPARE.

69. REVISED CKT SCP110A-3M FROM SPARE TO SIMRAD CABINET

70. ADDED CKT P109-7(C1), FIRE DAMPER FD1

71. ADDED BLANK LOCATION TO PANEL P103

72. REVISED DESCRIPTION OF CKT EP128-10

73. REVISED CKT FROM PMCB-1 TO PMCB1-1, PMCB1-2, PMCB1-3, AND PMCB1-4.

74. REVISED CKT FROM PMCB-2 TO PMCB2-1, PMCB2-2, PMCB2-3, AND PMCB2-4.

75. ADDED DISCONNECT SWITCH (2 EA) ITEM 251 & 252, CKT EP24-2A AND

EP24-1A.

76. DELETED 2 EA BLANK LOCATIONS FROM POWER PANEL EP100

77. REVISED LABELING OF CKTS OFF OF PANEL EP100. EX FROM EP121 TO

EP100-121.

78. ADDED CKT P108-3(C2), P108-4(C2), P107-3(C2), P107-3(C3), P107-4(C2),

P107-4(C3),

79. REVISED CONTROLLER TYPE OF P610-2, AND P610-4 FROM HOA TO FSS

80. REVISED BREAKER SIZE OF P610-14 FROM 35AT TO 40AT

81. REVISED BRAEKER SIZE OF P616-11 FROM 15AT TO 125AT

82. REVISED BREAKER SIZE OF P616-12 FROM 15AT TO 35AT.

83. ADDED CKT'S P120-6(T), P120-7(T), AND P119-13(T)

84. ADDED CKT P109-2G(T)

85. ADDED CKT P112-3L(T)

86. REVISED CKT BREAKER SIZE OF P112-2R FROM 20AT TO 25AT

87. REVISED CKT BREAKER SIZE OF P416-11, P416-12, AND P416-13 FROM 15AT

TO 20AT

88. REVISED CKT P406-5 FROM 02 LVL DK TO 01 LVL DK

89. REVISED ITEM 239 FROM 5KVA 1 PHASE TO 6 KVA 3 PHASE.

90. ADDED ITEM 253 TO CKT P222-19.

91. REVISED P222-9 BREAKER FROM 3P TO 2P

92. REVISED P222-14 FROM 1P TO 2P

93. REVISED P222-21 FROM BLANK TO SPARE

94. REVISED P120-1V FROM SPARE TO GARBAGE DISPOSAL

95. REVISED P120-1K AND P120-1M CKT BREAKER FROM…