Forward WTC Blank SOS.xlsx
XLSX spreadsheet 19 KB Posted
- Attached to
- USCGC Forward DS1 Watertight Closures
- Solicitation number
- 52000QR240002791
About this file
This solicitation requests quotations for watertight doors and hatches for the US Coast Guard Cutter Forward. The Coast Guard seeks three new weathertight doors and three watertight hatches to specifications provided in an attached spreadsheet. Quotations are due by March 30, 2024 and should be emailed to two Coast Guard contacts listed. The contract will be a firm fixed price contract awarded based on best value considering price and other factors. The successful bidder must deliver the closures by July 1, 2024 to the address provided for installation during a dockside repair period.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 905-WMEC_167_1_1_-_M- List of Closures.pdf | ||
| WTC Order Description Form_Forward DS1 FY24 IGE.xlsx | XLSX spreadsheet | |
| SOW Forward WTC.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Rev | Item | Closure Number | Compartment Served | Closure Description | Hardware | Closure Location | Cut in Steel | Remarks/Notes | Min Desn PSI | Estimate | ||||||||||||||||
| Type | Clear Opening | Sill Hgt. | Hand | Swing | Dogs | SMY It No. | Hasp & Staple | Hook & Bumbper | Fixed Light | Type of Lock | Water-Shed | Deck | Loc from Fram | Loc from SL | P/S | Side of BHD | Cut Size | HGT ABV STL Deck | Cor Rad | |||||||
| 13 | 1-82-1 | Passageway | WTQA | 26" x 66" | 9" | LH | AI | 10 | 5 | Yes | Yes | 9" | - | - | Main | BHD 82 | 24 | S | AFT | 33" X 73" | 5 3/4" | 11 1/2" | 2, 7 | 2.6 | $ | |
| 22 | 1-208-2 | Fan Room | WT | 26" x 66" | 9" | LH | FO | 10 | 10 | Yes | Yes | 9" | - | - | Main | 21 AFT | 10' 6" | P | Outboard | 33" X 73" | 6 3/4" | 12 1/2" | 2, 4, 5, 6, 7 | 13/5 | $ | |
| Shipping | $ |
| Total | $ | |
| Remarks/Notes fro column "Y" | ||
| 1 Door to have high hinges. | ||
| 2 Door to have low hinges. | ||
| 3 Door to be operated from hinge side of door only (see Ref 19 for door interlock). | ||
| 4 Fixed light to be fitted with a dead light cover. | ||
| 5 Pipe lever storage required both sides of bulkhead, see Detal 30-C. | ||
| 6 Door to be outfitted with EMI straps, pc 34. | ||
| 7 For door installation see Detail 32-A. | ||
| 8 Closure no 1-165-1 as built sill height condition for hulls 905 and 906 is 8 1/2". |
File details come from the government source that posted it. Updated .