Fort Peck Digital Governors Dwgs Vol 2 Color.pdf

PDF 45 MB Posted

Attached to
Ft. Peck Digital Governor Install Federal contract opportunity
Solicitation number
W9128F21R0003
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

This solicitation requests proposals for the Ft. Peck Digital Governor Install project. The Department of the Army Corps of Engineers Engineering District Omaha seeks to install digital governors at Ft. Peck Dam through solicitation number W9128F21R0003. Offerors should review the supporting documentation also posted to understand the full scope of providing governor installation services. Proposals are due by the date specified in the solicitation documentation. The selected contractor will be awarded a contract to complete the digital governor installation for the Army Corps of Engineers at Ft. Peck Dam.

View the file

Other files for this federal contract opportunity

Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MISSOURI RIVER

FORT PECK DAM

DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.

THE INITIALS OR SIGNATURES AND REGISTRATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE PROJECT

THIS PROJECT WAS DESIGNED BY THE HYDROELECTRIC DESIGN CENTER OF THE U.S. ARMY CORPS OF ENGINEERS.

POWERHOUSE

W9128F21R0003 of Engineers US Army Corps

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

DIGITAL GOVERNORS

VOLUME 2

DIGITAL GOVERNOR

FORT PECK DAM PLANT NO. 2

NOVEMBER 6, 2020

VOLUME 2

Image by Google Maps, 2017 Image by Google Maps, 2017

FORT PECK DAM AREA

DATE

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A D

IS

T R

IC

T

W F

R

S

E V

E N R

M

IL

E S P .E

/1

/0

A

K O

R O

B E

IN

IK

O V

G-001

P R

O J E

C T L

O C

A T

IO

N A

N D

V

IC

IN

IT

Y M

A P

S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

J

R O

S E

N T

H A

L

K

A N

A M

K W

A -P

O K

U

V F P

G -0

.d g n

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

SCALE: NTS

VICINITY MAP

SCALE: NTS

SITE PLAN

SITE PHOTO

VOLUME 2

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

IN

D

E X

D R

A W

IN

G

G-002

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IG

IT

A L G

O V

E R

N O

R S

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

F O

R T P

E C

K D

A M

W F

R

E V

E N R

M

IL

E S P .E

D

/1

/0

V F P

G -0

.d g n

J

R O

S E

N T

H A

L

K

A N

A M

K W

A -P

O K

U

A

K O

R O

B E

IN

IK

O V

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

P O

R T

L A

N D

O R

E G

O N

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

INDEX TO DRAWINGS

FILE NUMBER

NO.

SHEET

TITLE

INDEX TO DRAWINGS

FILE NUMBER

NO.

SHEET

TITLE

MECHANICAL REMOVAL

MECHANICAL INSTALL

ELECTRICAL REMOVAL

ELECTRICAL INSTALL

VOLUME 2 - GENERAL

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A D

IS

T R

F

R

E V

E N R

M

IL

E S P

/1

/0

A

K O

R O

B E

IN

IK

O V

G-004

IN

D

E X

J

R O

S E

N T

H A

L

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T

P

R T

L A

N D

O R

E G

O N

K

A N

A M

K W

A -P

O K

U

V F P

G -0

.d g n

R E

F E

R E

N C

E D

R A

W

IN

G

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

FILE NUMBER TITLE

REFERENCE

REQ'D

AS-BUILT

INDEX TO REFERENCE DRAWINGSINDEX TO REFERENCE DRAWINGS

REFERENCE

FILE NUMBER TITLE

REQ'D

AS-BUILT

Z

Z

X

(84E275)

(84E277)

FENCE

FENCE

SHOWER

BATTERY

ROOM

STAIR "B"

STAIR "G"

S

T O

R E

S

STAIR "H"

SWITCHGEAR ROOM

STAIR "E"

TURBINE ROOM

STAIR SHAFT

STAIR "D"

FREIGHT

ELEVATOR

INSULATING

OIL STORAGE

BUILDING

T O

IL

E T A

N D L

O C

K E

R R

M

CLO.

DRAFT TUBE DECK-EL. 2049.0

STAIR "F"

C A

B L E A

N D A

C C

E S

S G

A L L E

R Y T

O P

O W

E R P

L A

N T

EQUIPMENT ROOM 2EQUIPMENTE ROOM 1

STAIR "C"

SEPTIC TANK

DECK-EL. 2047.0

SEPTIC

TANK

TUNNEL 3

TRAINING WALL

F.D.

ELEC.

DRIER

D.F.

TH

SHELVES

TH.

B E

N C

H L

O C

K E

R S

F.D.

S.S.

P

IP

E S

P A

C E

M.G. SETS

MOTOR

CONTROL

CENTER 1

INVERTER D

.C

C O

N T

R O

L S

W B 'D

BATTERIES

F.D.

SHELVES

NEUT.

ACB

MOTOR CONTROL CENTER 4

AC

CONTROL SECTION

DC

ACB M.G. SET

ACTUATOR AND

GOVERNOR OIL

PUMPING UNITS

UNIT CONTROL

SWITCHBOARD

M.G. SET ACB MOTOR CONTROL CENTER 5

NEUT.

DEVICE

AC

CONTROL SECTION

DC

TH

POWER RECEPTACLE

TELEPHONE

OPERATOR'S

PLATFORM

CABLE REEL

POWER RECEPTACLE

U P

SINK

HANDRAIL

GATE SLOT

FRONT

RAMP UP

GREASE

PUMP

GREASE

PUMP

JACKING

PUMP

DISMANTLING

PLATFORM

WALKWAY

WALKWAY

PIPE TRENCH

100# AIR RECEIVER

(GEN. BRAKING)

F R

O N

T

4.16KV.

SWITCHGEAR

GENERATOR

SWITCHGEAR

TH

EXHAUST

FAN E-1

GUARDRAIL

GUARDRAIL

STATION SERVICE SWGR.

EL. 2049.0

HATCH

COVERS

U P

GRILLE

ERECTION BAY

LIGHTING

TRANSFORMER

MOTOR CONTROL

CENTER 6

MOTOR CONTROL

CENTER 7

E L .0

EL. 2049.0

LONG > SURGE TANKS AND SURGE TANK STRUCTURE

> BUTTERFLY VALVES

C A

B L E T

R A

Y S

SUPPLY

FAN S2

F

IL

T E

R

> SURGE TANK 5

UP

SLIDING DOOR

F.D.

F.D.

S.S.

W.H.

RAILING

LONG > UNITS

RISER 5> RISERS

F.D.

220 C.F.

AIR RECEIVERS

(TAILWATER DEPRESSING)

POWER

RECEPTACLE

TRANSFORMER

UNIT 4 LIGHTING

TRANSFORMER

UNIT 5 LIGHTING

TRANSFORMER

E

M

D C

B

G

F

A

EL. 2052.0

UP

RISER 4

CABLE GALLERY

BELOW

NEUT. ACB

DISMANTLING

PLATFORM

RAMP UP

D.F.

U

PGRILLE

> UNIT 5

TH

> UNIT 4

> SURGE TANK 4

SUPPLY

FAN S1

R

IG

H T R

E T

A

IN

IN

G W

A L L

H E

A T

E R

F

IL

T E

R RAILING

F.D.

SUPPLY

FAN S5

ROOF-EL. 2048.0

D N

D N

W.H.

FLOWMETER

NEUT.

DEVICE

GOVERNOR OIL

PRESSURE TANKS

FLOWMETER

DT.

ACCESS

D.T. ACCESS

15 TON DRAFT TUBE

GANTRY CRANE

T.W. RECORDING

TRANSMITTER

UP

JACKING

PUMP

H E

A T

E R

HATCHHATCH

EL. 2052.0

EL. 2052.0

SURGE EQUIPT.

SURGE EQUIPT.

D N .D

N

EL. 2050.0EL. 2050.0

DOWN

D O

W N

D O

W N

GEN C O CONTROL CABINET

Y

Y

(84E276)

1A 2A 3A

2 4 5 6 7 8

B

C

D

X

2C O PROTECTION

C PENSTOCK 4L C PENSTOCK 5L

154'-2"31'-4"

31'-7"20'-6"20'-6"20'-6"20'-6"20'-6"20'-6"31'-7"

186'-2"

1'-6"

13'-3"20'-0"20'-4"

/1

36'-0"56'-0"

18'-0" 18'-0"

6'-0"

11'-0"

(84E271)

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A D

IS

T R

F

R

E V

E N R

M

IL

E S P

/1

/0

A

K O

R O

B E

IN

IK

O V

J

R O

S E

N T

H A

L

G-005

P O

W E

R P

L A

N T

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

K

A N

A M

K W

A -P

O K

U

P L

A N V

IE

W

V F P

G -0

.d g n

NOTES:

MFP-OPN84E273, 000

1. POWER PLANT 2 PLAN VIEW

REFERENCES:

ARRANGEMENT

POWER PLANT 2 EQUIPMENT

POWER PLANT 2 - PLAN VIEW

NOT TO SCALE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

GENERAL REMOVAL NOTES:

GENERAL INSTALL NOTES:

GENERAL NOTES:

FOR DETAILS OF HYDRAULIC-MECHANICAL GOVERNOR EQUIPMENT REMOVAL.

3. SEE SPECIFICATION SECTION 02 41 19.00 26 AND INSTALL TASK ORDER

FOR CLARITY.

2. SOME COMPONENTS AND FEATURES ON THE REMOVAL DRAWINGS ARE OMITTED

INDICATED BY HEAVIER LINE WEIGHTS AND GREEN COLOR,TEXT AND/OR AS NOTED.

1. ON "MD###" SHEETS, EXISTING EQUIPMENT TO BE REMOVED IS

2. MECHANICAL DRAWINGS ARE REPRESENTATIVE OF ALL UNITS UNLESS SPECIFIED.

1. ELECTRICAL DRAWINGS ARE REPRESENTATIVE AND APPLY TO EACH UNIT.

FURNISHED.

ALL OTHER EQUIPMENT IDENTIFIED AS NEW SHALL BE INSTALL CONTRACTOR

SYMBOL INDICATES ITEMS SUPPLIED AS GOVERNMENT FURNISHED EQUIPMENT.

ALUMINUM COMPONENTS NOT REQUIRED.

PAINTING OF STAINLESS STEEL CONDUIT AND

6. PAINT ALL ITEMS PER SECTION 09 90 00.00 26.

INSTALLATION DETAILS PER SECTION 48 19 00.00 26.

TO FACILITATE A BETTER INSTALLATION. SUBMIT PRESSURE PIPE ROUTING AND

BE THE MOST PRACTICABLE ROUTING. SLIGHT MODIFICATION MAY BE ALLOWED

5. NEW PRESSURE PIPE ROUTING SHOWN ON THE INSTALL DRAWINGS MAY NOT

ARE REFERENCED ON THE FOLLOWING INDIVIDUAL MECHANICAL DRAWINGS.

DRAWING SHALL GOVERN. NOT ALL SYMBOLS SHOWN ON THIS DRAWING

DIFFERS FROM THIS DRAWING, THE INFORMATION ON THE INDIVIDUAL

DEVICE NUMBERS AND LEGEND APPEAR ON AN INDIVIDUAL DRAWING AND

THIS DRAWING ARE APPLICABLE FOR ALL DRAWINGS. HOWEVER, IF SYMBOLS,

4. HYDRAULIC SCHEMATIC SYMBOLS, DEVICE NUMBERS AND LEGEND SHOWN ON

3. SEE SPECIFICATION SECTION 48 19 00.00 26 FOR DETAILS OF INSTALLATION.

FOR CLARITY AND/OR MAY NOT BE TO SCALE.

2. SOME COMPONENTS AND FEATURES ON THE FOLLOWING DRAWINGS ARE OMITTED

INDICATED BY HEAVIER LINE WIEGHTS AND RED COLOR, AND/ OR AS NOTED.

1. ON "M-###" SHEETS, NEW EQUIPMENT TO BE INSTALLED OR PROVIDED IS

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

F

R

/1

/0

K

A N

A M

K W

A -P

O

U

R O

S E

N T

H A

L

AC

CYLINDER, DOUBLE ACTING

CONTROL, SPRING

CYLINDER, SINGLE ACTING

CONTROL, LEVER

CONTROL, PEDAL

CONTROL, MANUAL

CONTROL, PUSHBUTTON

CONTROL, DETENT

COOLER, LIQUID COOLED

COOLER

BULKHEAD CONNECTION

PILOT CONTROLLED OPENING

PILOT CONTROLLED CLOSING

CHECK VALVE

CHECK VALVE

CHECK VALVE

SPRING LOADED

CARTRIDGE VALVE

CHECK VALVE

FIXED DISPLACEMENT

AIR COMPRESSOR

ACCUMULATOR

LINE, FLEXIBLE

HEATER

FILTER WITH BYPASS

ELECTRIC LINE

ELECTRIC MOTOR

FILTER OR DIFFUSER

SHUT-OFF VALVE, NORMALLY OPEN

SHUT-OFF VALVE, NORMALLY CLOSED

SHUTTLE VALVE

QUICK DISCONNECT COUPLING

PROPORTIONAL VALVE

PUMP, VARIABLE DISPLACEMENT

PUMP, FIXED DISPLACEMENT

PUMP, HAND OPERATED

PRESSURE SOURCE

PLUGGED PORT

MEASUREMENT, FLOW SHUT-OFF VALVE, 3-WAY

SNUBBER

FLOAT VALVE

PRESSURE TRANSDUCER

PRESSURE

MEASUREMENT,

TEMPERATURE

MEASUREMENT,

ADJUSTABLE

PRESSURE SWITCH

VALVE ADJUSTABLE

PRESSURE REDUCING

VALVE ADJUSTABLE

PRESSURE RELIEF

GOVERNOR PRESSURE TANK

2-WAY, 2-POSITION

DIRECTIONAL CONTROL VALVE

3-WAY, 2-POSITION

DIRECTIONAL CONTROL VALVE

3-WAY, 3-POSITION

DIRECTIONAL CONTROL VALVE

4-WAY, 2-POSITION

DIRECTIONAL CONTROL VALVE

4-WAY, 3-POSITION

DIRECTIONAL CONTROL VALVE

INDICATOR

FILTER WITH PLUGGED

INDICATORS

ELECTRICAL CLOGGING

FILTER WITH VISUAL AND

ADJUSTABLE

FLOW CONTROL VALVE,

ADJUSTABLE WITH BYPASS

FLOW CONTROL VALVE

ELECTRICAL SOLENOID

CONTROL,

MATERIAL INDICATIONS

EXISTING CONCRETE

GRAPHIC SYMBOLS LEGEND

SECTION SYMBOLS

SECTION

VIEW

SHEET WHERE THE SECTION OR DETAIL IS TAKEN

THE SECTION OR DETAIL APPEARS ON THE SAME

BOTTOM HALF OF SYMBOL IS LEFT BLANK WHEN

IDENTIFICATION NUMBER

SECTION OR DETAIL

SECTION OR DETAIL IS DRAWN

PLATE NUMBER ON WHICH

SECTION OR DETAIL IS TAKEN

PLATE NUMBER ON WHICH

G-006

M E

C H

A N

IC

A L G

E N

E R

A L N

O T

E S

A N

D L

E G

E N

D H

Y D

R O

E L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

O N

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

A

K O

R O

B E

IN

IK

O V

V F P

G -0

.d g n

S T

E V

E N R

M

IL

E S P .E

M-105

A

M-506

SECTION

OMAHA DISTRICT

NOTES:

EXISTING CONCRETE

(PLANS, DETAILS, ELEVATIONS)

CONDUIT EXPOSED, CABLE OR BUS

WIRE CONNECTED

WIRE CROSSING (NOT CONNECTED)

AMMETER

VOLT METER

WATT METER

FREQUENCY METER

SYNCHROSCOPE

SYNCHRONIZING LAMPS

CONDUIT/CABLE (PLANS, DETAILS, ELEVATIONS)

CONDUIT EMBEDDED IN FLOOR, WALL OR UNDERGROUND

CONDUIT TURNED AWAY FROM OBSERVER (PLANS, DETAILS, ELEVATIONS)

CONDUIT TURNED TOWARD OBSERVER (PLANS, DETAILS, ELEVATIONS)

TO CONTROL DEVICE NUMBER

RELAY, FUNCTION ACCORDING

V

W

F

S

L

A

H HYDROGEN DENSITY MONITOR

CONDUIT TERMINATION AT CABLE TRAY (PLANS, DETAILS, ELEVATIONS)

OUTPUT - SOLID-STATE ELEMENT OR DEVICE

INPUT - SOLID-STATE ELEMENT OR DEVICE

K

DISCONNECT SWITCH

SWITCHYARD MOTOR OPERATED

115kV SWITCHYARD CIRCUIT BREAKER

EQUIPMENT ENCLOSURE

SURGE ARRESTER

SURGE CAPACITOR

RESISTOR

AIR CIRCUIT BREAKER

RATIO AS SHOWN

CURRENT TRANSFORMERS, NUMBER AND CURRENT

AND VOLTAGES AS SHOWN

POTENTIAL OR CONTROL TRANSFORMERS, NUMBER

CONNECTION TO GROUND BUS

CONTACTS (NORMALLY OPEN)

CONTACTS (NORMALLY CLOSED)

FUSE

TRANSFORMER (CONTROL DIAGRAM)

POWER TRANSFORMER (ONE LINE DIAGRAM)

DISCONNECT SWITCH

TEST BLOCK

AMMETER SWITCH

DISCONNECTING DEVICE, DISCONNECTING CONTACT

VOLTMETER SWITCH

SYNCHRONIZING SWITCH (I=INCOMING, R=RUNNING)

SPARE WIRE(S)

DRAWOUT CIRCUIT BREAKER

RESISTOR OR SHUNT TRIP ELEMENT

DRAWOUT CIRCUIT BREAKER WITH INTERLOCKS

A=AMBER

INDICATING LIGHT: R=RED, G=GREEN, W=WHITE,

DETAILS, ELEVATIONS)

OR TURNED AWAY FROM OBSERVER (PLANS,

NON-SEGREGATED PHASE BUS TURNED TOWARDS

INVERTER OR RECTIFIER

SWITCH

2-POSITION SELECTOR SWITCH OR TRANSFER

M

OR

R

SS

I R

SP

TB

AS

VS

480-120

200:5

DIRECTION OF KEY TRANSFER

BREAKER KEYED INTERLOCK

DEVISE OPEN. (WITH KEY REMOVED)

KEY INTERLOCK USED TO LOCK

DEVISE OPEN. (WITH KEY HELD)

KEY INTERLOCK USED TO LOCK

BREAKER MECHANICAL INTERLOCK

L-0

L-0

MATERIAL INDICATIONS

GRAPHIC SYMBOLS LEGEND (CONT.)GRAPHIC SYMBOLS LEGEND

LABELING DETAILS DETAILS.

9. SEE SPECIFICATION SECTION 26 10 00.00 26 FOR WIRE

WHEN AVAILABLE.

AND MAY BE SUPERSEDED BY MANUFACTURER'S SHOP DRAWINGS

THE PROCUREMENT OF GOVERNMENT FURNISHED EQUIPMENT

8. THE DRAWINGS ARE BASED ON A TASK ORDER PREPARED FOR

7. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS.

SIZED PER NEC TABLE 250-122.

DRAWINGS OR IN THE CONDUIT AND CABLE SCHEDULES,

AND BRANCH CIRCUITS WHETHER OR NOT SHOWN ON THE

REQUIRED AND SHALL BE PROVIDED IN ALL NEW FEEDERS

TO REDUCE DRAWING CLUTTER FOR CLARITY, BUT ARE

6. EQUIPMENT GROUNDING CONDUCTORS MAY NOT BE SHOWN

INFORMATION ON THE INDIVIDUAL DRAWING SHALL GOVERN.

AN INDIVIDUAL DRAWING AND DIFFERS FROM THIS DRAWING, THE

FOR ALL DRAWINGS. HOWEVER,IF SYMBOLS AND LEGEND APPEAR ON

5. SYMBOLS AND LEGEND SHOWN ON THIS DRAWING ARE APPLICABLE

VALUE.

QUANTITIES TO WHICH THEY RESPOND ARE OF THE LOWEST

WITH CONTACTS IN THE DE-ENERGIZED POSITION OR WHEN

4. CONTROL DIAGRAMS SHOW CONTROL AND TRANSFER SWITCHES

REFERENCED ON THE FOLLOWING INDIVIDUAL DRAWINGS.

3. ITEMS SHOWN ON THIS DRAWING ARE NOT ALL NECESSARILY

UNLESS OTHERWISE NOTED.

2. CONDUITS AND BOXES ARE DIMENSIONED TO CENTERLINES

OR AS NOTED.

IS INDICATED BY HEAVIER WEIGHT LINES OR TEXT,

HEAVIER WEIGHT LINES OR TEXT. INSTALLATION WORK

1. ON ALL SHEETS, REMOVAL WORK IS INDICATED BY

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

F

R

/1

A N

A M

K W

A -P

O

R O

S E

N T

H A

L

G-007

E L E

C T

R

IC

A L G

E N

E R

A L N

O T

E S

A N

D L

E G

E N

D H

Y D

R O

E L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A

K O

R O

B E

IN

IK

O V

S T

E V

E N R

M

IL

E S P .E

V F P

G -0

.d g n

IDENTIFICATION LETTER

SECTION OR DETAIL

SECTION

SECTION OR DETAIL IS DRAWN

PLATE NUMBER ON WHICH

SECTION

VIEW

A

A

THE SECTION OR DETAIL IS TAKEN

ON THE SAME SHEET WHERE

SECTION OR DETAIL APPEARS

IS LEFT BLANK WHEN THE

BOTTOM HALF OF SYMBOL

M-105

WIRE LABEL WIRE LABEL

LABEL

BLOCK

TERMINAL

WIRE LABELING EXAMPLE

SECTION SYMBOLS

7IB-D7 AP DG1

UNIT 4 CL

NOTES:

SUPPORTS AND ACCESSORIES.

CONDUIT, PULLEYS AND ALL

REMOVE RESTORING CABLE,

SUPPORTS AND ACCESSORIES.

CONDUIT, PULLEYS AND ALL

REMOVE RESTORING CABLE,

REFERENCES:

UNIT 4 - PIPING ARRANGMENT982575

TO GOVERNOR CABINET.

LOCATED ON SERVO CLOSEST

RESTORING CABLE ON UNIT 5,

UNIT 5 IS MIRRORED IN DIRECTION TO UNIT 4.

3. DETAILS SHOWN ON THIS SHEET ARE TYPICAL OF UNITS 4 & 5.

HYDRAULIC-MECHANICAL GOVERNOR.

SEE SPECIFICATION SECTION 02 41 19.00 26 REMOVAL OF

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS TO BE REMOVED.

1. SEE GENERAL NOTES ON G-006

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

N

F

R

/1

M

B O

O

S

H

IN

N

E V

E N R

M

IL

E S P .E

MD101

J

R O

S E

N T

H A

L

R E

M O

V A

L

G A

T E R

E S

T O

R

IN

G C

A B

L E

V F P

M D

.d

SECTION

ACCUMALATOR TANK

CABINET, SUMP & PUMPS

GOVERNOR ACTUATOR

ACCUMALATOR TANK

CABINET, SUMP & PUMPS

GOVERNOR ACTUATOR

PLAN VIEW

SCALE: NTS

RESTORING POST

2 PLACES, TYP.

GATE SERVO MOTOR,

RRW

131011

R R

18 18

17 17

1. TACHOMETER INDICATOR

3. TRANSFER VALVE POSITION INDICATOR

4. SPEED DROOP POSITION INDICATOR 0-5%

5. GATE LIMIT & GATE POSITION DUAL INDICATOR

6. SPEED ADJUSTMENT POSITION INDICATOR

7. SPEED DROOP CONTROL KNOB

8. GATE LIMIT CONTROL KNOB

9. SPEED ADJUSTMENT CONTROL KNOB

13. TRANSFER VALVE CONTROL

2. AIR BRAKE PRESSURE GAUGE (DUPLEX)

10. CABINET LIGHT SWITCH

11. GENERATOR BRAKE CONTROL SWITCH

SEE NOTE 4

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B O

O

S

H

IN

N

E V

E N R

M

IL

E S P .E

MD201

J

R O

S E

N T

H A

L

R E

M O

V A

L

G O

V E

R N

O R A

C T

U A

T O

R C

A B

IN

E T

V F P

M D

.d

16. GOVERNOR OIL PRESSURE GAUGE

17. GOVERNOR OIL PUMP ECHELON CONTROL KNOB

18. GOVERNOR OIL PUMP CONTROL SWITCH

19. GOVERNOR SUMP OIL LEVEL GAUGE

20.

(FURNISHED BY GEN. MFR.)

THRUST BEARING HIGH PRESSURE OIL PRESSURE GAUGE

INSTRUMENTS MOUNTED ON CONTROL FACE OF ACTUATOR

WHITE INDICATING LIGHT

RED INDICATING LIGHT

GREEN INDICATING LIGHT

AMBER INDICATING LIGHT

LEGEND

NOTES:

982575 UNIT 4 - ACTUATOR ARRANGMENT

REFERENCES:

ACTUATOR CABINET FRONT VIEW

NTS

EXPENSE TO THE GOVERNMENT.

DAMAGE DOES OCCUR, REPLACE THE EQUIPMENT IN-KIND AT NO ADDITIONAL

OF THE CONTRACTOR TO ENSURE NO DAMAGE OCCURS TO THE EQUIPMENT. IF

THESE ITEMS ARE CURRENTLY IN WORKING CONDITION, IT IS THE RESPONSIBILITY

4. ITEMS 2, 10 AND 11 ARE TO BE REUSED. SEE SHEET M-201 FOR INSTALLATION DETAILS.

DIRECTION TO UNIT 4.

3. DETAILS SHOWN ON THIS SHEET ARE TYPICAL OF UNITS 4 & 5. UNIT 5 IS MIRRORED IN

SECTION 02 41 19.00 26 REMOVAL OF HYDRAULIC-MECHANICAL GOVERNOR.

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS TO BE REMOVED. SEE SPECIFICATION

1. SEE GENERAL NOTES ON G-006.

ASSEMBLY

ROTOR

STATOR

2 BEARINGS

NOTES:

EXISTING PROXIMITY PROBE

THE STATOR HOUSING FROM THE ASSEMBLY.

REMOVE A SET SCREW BEHIND TERMINAL BLOCKS TO FREE

5. VERIFY IF TERMINAL BLOCKS REQUIRE REMOVAL TO ACCESS AND

CONTRACTOR TO FIELD VERIFY & SHOW ON SHOP DWGS.

4. LOCATION OF EQUIPMENT SHOWN IS APPROXIMATE. INSTALLATION

3. DETAILS SHOWN ON THIS SHEET ARE TYPICAL OF UNITS 4 & 5.

HYDRAULIC-MECHANICAL GOVERNOR.

SEE SPECIFICATION SECTION 02 41 19.00 26 REMOVAL OF

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS TO BE REMOVED.

1. SEE GENERAL NOTES ON SHEET G-006.

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B O

O

S

H

IN

N

E V

E N R

M

IL

E S P .E

MD501

J

R O

S E

N T

H A

L

R E

M O

V A

L

P E

R M

A N

E N

T M

A G

N E

T G

E N

E R

A T

O R

V F P

M D

.d

PERMANENT MAGNET GENERATOR (PMG)

NTS

OVERSPEED SWITCHES

OVERSPEED FLYBALL

SLIDING SLEEVE

MAIN DRIVE GEAR

COUPLING

UPPER DRIVE

SEE NOTE 5

TERMINAL BLOCK ENCLOSURE

VALVE

BALL

VALVE

BALL

VALVE

BALL

AIR

OIL

TANK

ACCUMULATOR

SUMP

PUMPS AND

UNLOADER VALVES

SPRING ACTION

0 1

10 109

1 0

2 3

GATE SERVOMOTOR

TO CLOSE

S U

P P

L Y

C L

O S

E

D R

A

IN

O P

E N

NUTS

TIMING

GATE

VALVE PLUNGER

DISTRIBUTING

GATE

RESTORING CABLE

SHAFT

RESTORING

GATE

GATE POSITION GATE LIMIT

ADJ.MOTOR

GATE LIMIT

SOLENOID

STOP

START

DROOP

SPEED

ADJ

SPEED

SLOW

FAST

SOLENOID

BYPASS

DASHPOT

SATION

COMPEN-

LINK

YEILD

SPRING

SUMP

TO

FLYBALL

GOVERNOR HEAD

VALVE

PILOT

NO

INDICATOR

VALVE

TRANSFER

CLOSED

OPEN

NC

MAIN AUX

VALVE

TRANSFER

WEIGHT

NONO

NC

STRAINER

VALVE

AUXILIARY

MOTOR

SYNCHRONIZING

SUPPLY

PRESSURE

SUMP

DRAIN TO

AIR ADMISSION LINE.

ACCUMULATOR

COMPONENTS

AIR BALANCING

AUTOMATIC

VALVE.

ADMISSION

OPERATED AIR

SOLENOID

NOTES:

UNIT 5 IS MIRRORED IN DIRECTION TO UNIT 4.

HYDRAULIC MECHANICAL GOVERNOR.

SEE SPECIFICATION SECTION 02 41 19.00 26 REMOVED OF

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS TO BE REMOVED.

1. SEE GENERAL NOTES ON G-006.

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

ACAC

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B O

O

S

H

IN

N

E V

E N R

M

IL

E S P .E

MD601

J

R O

S E

N T

H A

L

R E

M O

V A

L

H Y

D R

A U

L

IC

D

IA

G R

A M

V F P

M D

.d

N.T.S.

GOVERNOR SCHEMATIC

5'-11"5'-11"

22'-0"

7'-2"

OF ACTUATOR

CONTROL SIDE

LUNIT 4 C

CONDUIT

RESTORING

PRESSURE TO OPEN GATES

PRESSURE TO CLOSE GATES

TO CLOSE

4.0 MA 20MA

NOTES:

14.75" STROKE

PRESSURE PIPING

GOVERNOR OIL

RESTORING POST

GATE SERVO MOTOR

RESTORING POST

BALL JOINT

OPERATING ROD

ALUMINUM

ADAPTER BRACKET

RESTORING POST

OPERATING ROD

ALUMINUM MLDT

MLDT TO JUNCTION BOX

FLEXIBLE CONNECTION FROM

NEW MLDT JUNCTION BOX

ACTUATOR CABINET

CONDUIT TO GOVERNOR

TO OIL PIPING

ATTACH JUNCTION BOX

REFERENCES:

982575 UNIT 4 - PIPING ARRANGEMENT

CABINET.

SERVO CLOSEST TO GOVERNOR

MLDT ON UNIT 5 TO BE LOCATED ON

SEE NOTE 5

SUPPORT BRACKET AND COVER

ACCUMULATOR

TYP. 2

MOTOR ASSEMBLY

GATE SERVO

COMPLETE REQUIREMENTS FOR THE BRACKET.

DESIGN INCLUDING MLDT COVER. SEE SPECIFICATION SECTION 48 19 00.00 26 FOR THE

DESIGN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A COMPLETE

5. THE MLDT SUPPORT BRACKET THAT IS SHOWN ON THIS DRAWING IS A CONCEPTUAL

LOCATED.

ALONG THE ALIGNMENT WHERE THE RESTORING CABLE ASSEMBLY WAS PREVIOUSLY

4. ROUTE NEW CONDUIT AND CABLE FROM MLDT JUNCTION BOX TO ACTUATOR CABINET

UNIT 5 IS MIRRORED IN DIRECTION TO UNIT 4.

SECTION 48 19 00.00 26 FOR NEW EQUIPMENT AND INSTALLATION REQUIREMENTS.

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS NEW EQUIPMENT. SEE SPECIFICATION

1. SEE GENERAL NOTES ON SHEET G-006

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B

E

V E

N R

M

IL

E S P .E

M-101

J

R O

S E

N T

H A

L

IN

S

T A

L L

G A

T E P

O S

IT

IO

N

V F P

M -1

.d g n

F E

E D

B A

C K T

R A

N S

D U

C E

R

PLAN VIEW

NTS

D T

R A

W

IC

K

B N.T.S.

DETAIL

A

SECTION

BASKET

STRAINER

MANHOLE

HANDHOLE

CABINET DOORS (22X46 1/2) (4)

SHUT-OFF VALVE

LEVEL GUAGE

SUMP OIL

DISTRIBUTING

VALVE

BREATHER

SUMP

CHK2

HANDLE TOWARDS ACTIVE TER

FLTSEL

CHK1

CABINET DOORS (38X46 1/2) (2)

R

RW

R R

18 18

17 17

NOTES:

NOT USED

NOT USED

NOT USED

DIGITAL GOVERNOR HMI

DUPLEX AIR BRAKE PRESSURE GAUGE

EMERGENCY STOP PUSH BUTTON

NOT USED

NOT USED

CABINET LIGHT SWITCH

GENERATOR BRAKE CONTROL SWITCH

NOT USED

NOT USED

TO POPPETS

NOT USED

NOT USED

NOT USED

SEE NOTE 8

8. ITEMS 2, 10, AND 11 ARE REUSED EQUIPMENT TO BE RELOCATED AS SHOWN.

PATTERN. GASKET MUST BE RATED TO THE SYSTEM PRESSURE OR HIGHER.

(AS APPROVED). CONTRACTOR TO FIELD VERIFY PLATE DIMENSIONS & MOUNTING BOLT

7. CONTRACTOR DESIGNED AUX VALVE COVER PLATE MUST HAVE O'RINGS OR GASKET

6. PROVIDE ALL MOUNTING AND CONNECTIONS FOR RELOCATED GAUGES AND SWITCHES.

SUPPLY AND DRAIN PIPING.

5. PLACE GOVERNOR CABINET AT AN ELEVATION SUCH THERE IS ACCESS FOR THE EHI

OF THE CONTRACTOR TO FINALIZE THE DESIGN.

4. THE PIPE ROUTING AND VALVE LOCATIONS ARE CONCEPTUAL. IT IS THE RESPONSIBILITY

MIRRORED IN DIRECTION TO UNIT 4.

3. DETAILS SHOWN ON THIS SHEET ARE TYPICAL OF UNITS 4 & 5. UNIT 5 DETAILS ARE

SECTION 48 19 00.00 26 FOR NEW EQUIPMENT AND INSTALLATION REQUIREMENTS.

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS NEW EQUIPMENT. SEE SPECIFICATION

1. SEE GENERAL MECHANICAL NOTES ON SHEET G-006.

ADAPTER PLATE

PILOT VALVE

GATE LVDT

FIXTURE.

GATE LVDT MOUNTING

BRACKET

EHI MOUNTING

EHI ASSEMBLY

PRESSURE SUPPLY

TO DRAIN

CONFIGURATION.

SEE DETAIL B FOR PORT

ISOLATING PLUNGERS.

GATE DISTRIBUTING VALVE

THREE-WAY BALL VALVE FOR FOR POPPETS.

PRESSURE SUPPLY/DRAIN

SEE NOTE 6

AND TRANSDUCER

PRESSURE SWITCHES

MOUNTING BRACKET

NEW PRESSURE SWITCH

MANIFOLD

PRESSURE SWITCH

ISOLATION VALVE

MANIFOLD

PRESSURE SWITCH

NORMALLY CLOSED

OFF VALVE

PRESSURE BLEED

PRESSURE

PORT FOR EHI SUPPLY

USE AUX VALVE SUPPLY

CABINET

NEW DIGITAL GOVERNOR

SUPPORT BRACKET FOR

CABINET WITH HMI

AMERICAN GOVERNOR

PORT FOR EHI DRAIN

USE AUX VALVE DRAINSEE NOTE 7.

PLATE.

AUX VALVE COVER

CABINET WITH HMI

AMERICAN GOVERNOR

CLOSE OFF ANY RESULTING OPENING

AND ANY PANELS REQUIRED TO

PROVIDE STRUCTURAL SUPPORT

DRAIN

PILOT VALVE

FOR SUMP PUMPS

NEW DIGITAL UNLOADER SWITCHES S

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B

E

V E

N R

M

IL

E S P .E

M-201

J

R O

S E

N T

H A

L

IN

S

T A

L L

G O

V E

R N

O R A

C T

U A

T O

R C

A B

IN

E T

V F P

M -2

.d

H

IN

N E

N

ITEM DESCRIPTION

GOVERNOR OIL PRESSURE GAUGE

GOVERNOR OIL PUMP ECHELON GAUGE

GOVERNOR OIL PUMP CONTROL SWITCH

GOVERNOR SUMP OIL LEVEL GAUGE

THRUST BEARING HIGH PRESSURE OIL PRESSURE GAUGE

982575 UNIT 4 - ACTUATOR ARRANGMENT

REFERENCES:

ACTUATOR EQUIPMENT SCHEDULE

B N.T.S.

CONFIGURATION

3-WAY VALVE PORT

N.T.S.

ACTUATOR CABINET - FRONT VIEW

ACTUATOR CABINET - PLAN VIEW

12 PITCH

126 TOOTH,

SCALE: NTS

COUPLING

UPPER DRIVE

ELECTRICAL ENCLOSURE

MAIN DRIVE GEAR

SLIDING SLEEVE

FLYBALL

OVERSPEED

SCALE: NTS

SCALE: NTS

ENCLOSURE

WIRING TO ELECTRICAL

RUN PROX PROBE

OF THE GEAR FACE

ALIGN PROBE WITH THE CENTER

ADJUST NUT LOCATION TO

DURING INSTALLATION

CHECK HORIZONTAL RUNOUT

TARGET AIR GAP 0.015 TO 0.045

SEE NOTE 6

NEW BEARINGS (2)

SWITCHES

OVERSPEED

NOTES:(PROXIMITY PROBE)

(2) ZERO VELOCITY PICKUP

OVERSPEED DEVICE

EXISTING MECHANICAL

PROXIMITY PROBE BRACKET

AN ADDITIONAL BUSHING HOLD DOWN SCREW.

PIN URETHANE BUSHING (2 TOTAL) TO SERVE AS

WASHER HEAD SCREW TO EACH LOWER DRIVE

DRILL, TAP AND INSTALL ONE 10-32 X 1/2" NYLOK

DRIVE SHAFT

X 0.06 THICK

(6) 3/8" WASHER 0.625 O.D. X 0.39 I.D.

(12) 3/8"-16UNC HEX JAM NUT

CASTING SHOWN.

1/2" THREAD ENGAGEMENT INTO

(2) 3/8-16UNC ROD, 2 3/4 LENGTH

HARDWARE.

7. PMG BELL HOUSING MAY REQUIRE CLEARANCE NOTCHES TO ALLOW ROOM FOR NEW

ROTATIONAL ALIGNMENT OF PROBES IS NOT REQUIRED.

6. PROBE BODY MUST BE ALIGNED PERPENDICULAR TO THE GEAR FACE AS NOTED.

PROBES.

WHILE INSTALLING PROBES. INSUFFICIENT CLEARANCE CAN CAUSE DAMAGE TO THE

5. TARGET AIR GAP IS 0.015 - 0.045 INCHES. BE AWARE OF HORIZONTAL GEAR RUNOUT

(4) PMG DRIVE PIN

(4) INSULATING WASHER

(2) SPAGHETTI INSULATION

(4) URETHANE BUSHING (UPPER DRIVE)

(2) BEARING LOCK WASHER

(4) PMG MAIN DRIVE BEARING

KIT INCLUDES:

4. REBUILD PMGS WITH GOVERNMENT SUPPLIED REBUILD KIT.

MIRRORED IN DIRECTION TO UNIT 4.

3. DETAILS SHOWN ON THIS SHEET ARE TYPICAL OF UNITS 4 & 5. UNIT 5 DETAILS ARE

SECTION 48 19 00.00 26 FOR NEW EQUIPMENT AND INSTALLATION REQUIREMENTS.

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS NEW EQUIPMENT. SEE SPECIFICATION

1. SEE GENERAL NOTES ON SHEET G-006.

NEW PROXIMITY PROBES (2)

NEW PROXIMITY PROBES (2)

M-501

PLAN - PROBE INSTALLATION

ELEVATION PMG ASSEMBLY

ELEVATION - PROBE INSTALLATION

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B

E

V E

N R

M

IL

E S P .E

M-501

J

R O

S E

N T

H A

L

IN

S

T A

L L

S P

E E

D S

IG

N A

L G

E N

E R

A T

O R

V F P

M -5

.d

H

IN

N

ELECTRIC - HYDRAULIC INTERFACE (EHI)

BLOCKED OFF

BLADE PROPORTIONAL VALVE PORTS

EHI MANIFOLD BLOCK

PORT PLUGGED

CONSTANT PRESSURE

GATE PROPORTIONAL VALVE

S

TEST PORT

(MLDT X 2)

GATE POSITION FEEDBACK

OFF VALVE

PRESSURE BLEED

SERVO MOTOR

WICKET GATE

VALVE

AIR RELEASE

VALVE PORTS PLUGGED

BLADE PROPORTIONAL

MANIFOLD

SOLENOID

GATE SHUTDOWN

LVDT.

FEEDBACK FROM

INTERMEDIATE

LVDT

LVDT MOUNT

COVER PLATE

AUX VALVE

CAP

PLUG OR

VALVE

EHI ISOLATION

ADMISSION SYSTEM

FOR AUTOMATIC AIR

PRESSURE TRANSDUCER

CHECK VALVE AC

VALVE ADJUSTABLE

PRESSURE RELIEF

SHUT-OFF VALVE, 3-WAY

FLOAT VALVE

ADJUSTABLE

PRESSURE SWITCH

PRESSURE TRANSDUCER

CHECK VALVE

SPRING LOADED

S

U

S

U

NORMALLY CLOSED

SHUT-OFF VALVE,

NORMALLY OPEN

SHUT-OFF VALVE,

DISPLACEMENT

PUMP, FIXED

VALVE 3-WAY, 3-POSITION

DIRECTIONAL CONTROL

SHUTDOWN VALVE

CONTROLED

SOLENOID

VALVE

PROPORTIONAL

CONTROLED

SOLENOID

AIR PIPE OIL PIPE

LEGEND

S

ELECTRIC MOTOR

ALTERNATING CURRENT

LEVEL TRANSDUCER

WITHGLASS SIGHT

LEVELOIL EXISTING

VALVE PIPING

EXISTING AUX

VALVE

3 - WAY

FLOOR

CABINET

ACTUATOR

PLUG

TYP.

3 PLACES

POPPET

CLOGGED FILTER INDICATOR

DUPLEX OIL FILTER WITH

HANDLE

FILTER SELECTIONCLOSING TIMING NUT

OPENING TIMING NUT

SUMP

TANK

ACCUMULATOR

AIR

OIL

HEAD DRAIN.

VALVE AND OIL

FROM TRANSFER

EXISTING LINES

A B

P T

S

U

AA B

AP B T

A B

B

A

PLUG

OPEN

GATES

CLOSE

GATES

PLUG PLUG

UNLOADER VALVES

GOVERNOR MECHANICAL SCHEMATIC

VALVE

BALL

VALVE

BALL

VALVE

BALL

SEE NOTE 5.

BALL VALVE.

OPERATED

SOLENOID

PRESSURE TRANSDUCER AND OIL TANK LEVEL SENSOR.

5. SOLENOID VALVE OPERATED BY GOVERNOR PLC BASED ON FEEDBACK FROM

ANY CORRECTIONS THAT ARE DISCOVERED.

EXISTING PIPING. FIELD VERIFY TO CONFIRM. UPDATE AS-BUILT DRAWINGS WITH

4. SCHEMATIC MAY NOT ACCURATELY REPRESENT THE ACTUAL CONFIGURATION OF

MIRRORED IN DIRECTION TO UNIT 4.

3. DETAILS SHOWN ON THIS SHEET ARE TYPICAL OF UNITS 4 & 5. UNIT 5 DETAILS ARE

SECTION 48 19 00.00 26 FOR NEW EQUIPMENT AND INSTALLATION REQUIREMENTS.

2. EQUIPMENT SHOWN IN BOLD LINE WEIGHT IS NEW EQUIPMENT. SEE SPECIFICATION

1. SEE GENERAL NOTES ON SHEET G-006.

NORMALLY CLOSED

SHUT-OFF VALVE,

SOLENOID OPERATED

AIR ADMISSION LINE.

EXISTING ACCUMULATOR

COMPONENTS

AIR BALANCING

EXISTING AUTOMATIC

CLOGGING INDICATORS

FILTER WITH VISUAL

(RELAY) VALVE

DISTRIBUTING

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

B

E

V E

N R

M

IL

E S P .E

M-601

J

R O

S E

N T

H A

L

IN

S

T A

L L

H Y

D R

A U

L

IC

D

IA

G R

A M

V F P

M -6

.d

T

R A

W

IC

K

OPEN GATES

AC AC

12" 6" 0 1' 2'

FRONT FACE

(12) 2" GROUT HOLE

4 5.4

3 4.1

FRONT

STUD (2•" LG.)

(10) •" HOLDDOWN

ƒ

R

U119U119U119U118U119U119

N104N103N102 N107N106N105

RG

U13

JACK

HYD. OIL TANKS

GOVERNOR

PROTECTION CUBICLE

GENERATOR 5 SURGE

AIR RECEIVER

UNIT

UNIT

UNIT 5

JACK

HYD.

PUMP

GREASE

SWGR.

5 NEUTRAL

GENERATOR

FLOWMETER

F L

O W

A A

RGRG G R G R

RGR

G R

R

AG

G R

RGRG

RG

W

RG

RG

N44N44

G RRG

RGRG G R

G R

W

RG

RG

N34

G R G R

RG

GR

RG G R

W

RG

RG

N54

RGRG

RWG RG

RG

R

G RG RRG

U122

N77

SG SG SG

U97U97 U97

U117

MCC 5

G R

FILLER, 1U

FILLER, 1U

TRIP

RESET

TRIP

RESET

TRIP

RESET

86C 86P

FILLER, 1U

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

STATES

FMS

AUX RELAYS, 4U

URX

TRIP RESET

87XT4

OVER/UNDER VOLTAGE

A.SYNC

AUTOSYNC ENABLED

SYNC CHK DISABLED

SYNC CHK ENABLED

AUTOSYNC DISABLED

SYNC CHK

CLOSE

GEN BRKR OPEN

GEN BRKR CLOSED

BRKR FAIL ENABLED

STATES

FMS

OVER/UNDER VOLTAGE

A.SYNC

AUTOSYNC ENABLED

SYNC CHK DISABLED

SYNC CHK ENABLED

AUTOSYNC DISABLED

SYNC CHK

CLOSE

GEN BRKR OPEN

GEN BRKR CLOSED

BRKR FAIL ENABLED

RESETTRIP

87XT5

FILLER, 1U

FILLER, 1U

TRIP

RESET

TRIP

RESET

TRIP

RESET

86C 86P

FILLER, 1U

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

TEST SWITCHES, 3U

STATES

FMS19

STATES

FMS

AUX RELAYS, 4U

URX

OVER/UNDER VOLTAGE

A.SYNC

AUTOSYNC ENABLED

SYNC CHK DISABLED

SYNC CHK ENABLED

AUTOSYNC DISABLED

SYNC CHK

CLOSE

GEN BRKR OPEN

GEN BRKR CLOSED

BRKR FAIL ENABLED

STATES

FMS

OVER/UNDER VOLTAGE

A.SYNC

AUTOSYNC ENABLED

SYNC CHK DISABLED

SYNC CHK ENABLED

AUTOSYNC DISABLED

SYNC CHK

CLOSE

GEN BRKR OPEN

GEN BRKR CLOSED

BRKR FAIL ENABLED

87XG

87XTB

STATES

FMS

STATES

FMS

STATES

FMS

VOLTS/HERTZ

DIFFERENTIAL

OVER/UNDER FREQUENCY

OVER/UNDER VOLTAGE

TIME OVERCURRENT

INST OVERCURRENT

TRIP

ENABLED

SEL-787

TRANSFORMER PROTECTION RELAY

87XG

U20

U13 U13

U20

MG-6

MG-6

MG-6

U99U99

MG-6

U99

MG-6

U99

SG SG SG

U97U97U97

U99U99

MG-6 MG-6 MG-6

U99

N76N75N75

N73 N72 N74

N72

N111

N78 N79

N82N81N80

N109 N110 N110

MG-6

U99 U99

MG-6 MG-6

U99

N109 N110 N110

U99

MG-6 MG-6

U100 U100

MG-6

N82N81N80

U97 U97 U97

SGSGSG

N77

U97

SG SG

U97

N78 N79

U97

SG

N76

U99

MG-6MG-6

U99

N75N75

U99

MG-6

N73 N72 N74

U99U99U99

MG-6 MG-6 MG-6

N72N108

U99

MG-6 MG-6

U99

N111

U99

MG-6

N1N1N2N3N3

PANEL U15 PANEL U14 PANEL U13 PANEL U12 PANEL U11

N121

UNIT 4 UNIT 4 UNIT 5

RELAY BOARD

STATION SERVICE

UNIT 5

" CONDUIT4

HOLE FOR

22" 6"

REAR FACE

CONDUIT

" 4

3HOLE FOR

22"6"

7 1/2 "22"28"28"28"22"7 1/2 "

1"

/2

/2

1 1/2 "

6"8"8"6"6"8"8"6"6"8"8"6"6"8"8"6"6"8"8"6"

28"28"28"28"28"

143"

1 1/2 "

1"

WELDED TO UNDERSIDE OF CHANNEL

" NUT2

1" HOLE WITH 8

5(28)

REAR

" HOLDDOWN BOLT2

" SLOT FOR4

1"X18

5(10)

ACROSS LEG.

"X2" BAR WELDED4

FOR ANCHOR BOLT

" HOLE IN BAR16

9(12)

REAR SILL

FRONT SILL

TOP VIEW

LEVELLING SILLS

TOP VIEW

143"

/2 " 2

/2

SECTION A-A

INCH = 1 FOOT4

3SCALE:

EL. 2049.0

POWER PLANT 2-TURBINE ROOM

LOCATION PLAN

NOTES:

DC AM

N14

U29

AC VM AC VM

N51

U30

N15

NULL

U33

N18

U71

N17

G W RU13

U14 G R

U1

N4

U2

N5

U3

N6

N1

U4 U5 U6

N9N8N7

U8

N10

U10 U13

U15

U14

U17U16 N11

U18

U14

U14

U14

U13

U14

U19 U21

U24

U14

U23U22

PANEL U1 PANEL U2

U56

N24 N25

U57

N23

U52

U13

U49

U13

U50

N22

U48U47U46

U14

U43 U44 U45

N21 U13U13

N20 U13U13

U37U36U35

N17 N18 U13 U12

N19

U34U33U32

DC AM NULL VAR

N16N15N14

U29 U30 U31

WMAC VMAC AM

N13

U28

ANNUNCIATOR PANEL

N1 N2

ANNUNCIATOR PANEL

U28

N26

AC AM AC AM AC AM AC AM

U60U59U59U58

N27 N28 N29 N30

AC VMWM

U61 U62

N16 N15

U35 U35 U35 U35

U13U14U13

U37 U36 U65 U66

U13N108U13

U67 U68 N31

U13

U69

N32

U13

N35 N36

N33

N37

U13

N38

U13

N39 N40

U13

N43

U13

N42N41

U13

N46

U57

N48

U57

N49

U56 U57

N50

U57

N47

PANEL U3

STATION SERVICEUNIT 5 UNIT 4UNIT 5

PANEL U4

U56

N56 N57

U57

N55

U73

U13

U49

U13

U50

U47 U48U46

U14

U43 U72 U45

N53

U13

U13 N52U13

U35 U36 U37

U13

N19

VAR

U34

N16

U31

AC VM

U28

ANNUNCIATOR PANEL

N3 N3

U1 U2 U3

N6N5N4

U4 U5 U6

N9N8N7

U8

N10

U10

U75

U13 U14 U14 U14

U18 N58

U17U16

U13 U14

U21U19

U14

U22 U23 U24

U14

PANEL U5

UNIT 4

U12

U80

N59

U80

N60

N61

U82

U83

N62

U83

N63

U81

SWITCHGEAR

13.8KV GENERATOR

SERVICE SWGR.

4.16 KV STATION

13.8KV BUS DUCT

PROTECTION CUBICLE

GENERATOR 4 SURGE

D.C. CONTROL BOARD

MCC 1

NEUTRAL SWGR.

GENERATOR 4

FLOWMETER

CREASE PUMP

MAIN SWITCHGEAR

STATION SERVICE

UNIT 4

MCC 4

CONTROL BD.

UNIT 4 & 5

ERNOR OIL PUMPS

ACTUATOR AND GOV-

LEGEND:

13.8KV CIRCUITS

4160V CIRCUITS

GROUND CIRCUIT

460V CIRCUITS

INSTRUMENT BOARD

INCH = 1 FOOT2

1SCALE: 1

U84

INCHES = 1 FOOT2

1SCALE: 1

REFERENCES:

MFP-OPN83E1150 PH 2 - UNIT 4 & 5 CONTROL BOARD ASSEMBLY

1. GREEN/BOLD INDICATE EQUIPMENT TO BE REMOVED/MODIFIED.

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

F

R

/1

ED201

E

M O

V A

L V F P E

D .d g n

A S

S E

M B

L Y

J

R O

S E

N T

H A

L

S

K O

R O

B E

IN

IK

O V

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

O N

U N

IT

C

O N

T R

O L B

O A

R D

S T

E V

E N R

M

IL

E S P .E

K

A M

A N

K W

A -P

O

G

F

E

D

C

B

A

1 2

PTT REC

REC

MICRO

WAVE

EMGD MICRO WAVE

RECEIVE

94EMGD1, 2

230KV LINE 6

DAWSON COUNTY

5 6 7 8

324T 424T 524T PTT REC �f------<l>------iHe------------ - - - -.-- -- - - - - -- - ----, 772T

85X

L 1382 T T

BPCS

1382T

BPCS

CLOSE SYNC

1382 � H

1382 BPCS

1382T-------, h--

FL PTT

SEND

V

Vv 3-230KV. GRD Y

115V GRD Y/66.4V

LVA

LV1

LV2

LV3

R

3-1200MR

400/SY

1381 1380 (KEY INTLK WITH 1381 & 1389).

1572T 21-13A 1672T ------+->--1 l'.l},� ,.........._ __

B c s ___ L�- - -

B6P/G4 M

86P/G5 1382T---------Lr----7 87XAT2

86P2BF

---+--------t-o---87X/T4

DLC1

DLC2

DLC3

DLCO

BDRA

BDRB

BDRC

86P/G4 86P/G5 1382T

ANN. 709

1572T 1672T 772T tr

EMGD

424T 524T 86P/G4--~o-�

86P/G5 772T

1572T 1672T

21-13B

'------+------, f-l1382 BPCS 87X/T5

M

PLANT 1 SYNCHRONIZING

:;-- CL ::i" LO r::' CL CL � W CL d ;;{° THYRISTOR- rJl Z � S! rJl rJl m ,:: rJl in z BRIDGES -CJJ .... ..._...._,.. I o- . <(

- z �c:::: 1-C:::: Z CD 0 1--<( - Cl:'. -

SPEED SWITCHES

125VDC FIELD

FLASHING

RFL PTT SEND

MIRRORED BIT PTT SEND

� 11G4

TO SEL-700,�-++c-=�--.-i--r

�GJM

481 (INTLK. WITH 424).

"--,,,, 480

4CTJ4CT

>IHIIII� 4TD4

4TD5

"1" o----j52/424 {

4TDA1

4TDA2

4TDA3

4TDAO

428A

L_-{)---0- VAR

u w )-C)---0---6-t------:---------t

U AS 3-3000MR-2500/5 Y--SC::::

3• 480VAC

FIRING PULSE CIRCUIT

>-+---+--t-2-14,400/120V

OPEN DELTA

�•>--------9

13.BKV/480

3-2500/5 l4GDB1

4GDB2

4GDB3

4GDBO

3-1500/SY

ANN

419,426A

LCL. ANN

BRIDGE

TRANSFE

K15 EXCIT

TRIP

4GD 7 o----J 52/422 FIBER TO PT

581 (INTLK

"--,,,, 580

524)

CASCADE

POTENTIAL

�&¥i� 115/69V

PLANT 2 SYNCHRONIZING

528A

TBC

TBC2

TBC3

TBCO

� 3-100-5/5Y�

� 3-2500/SY �

ANN 601

• \-�-- 428T

528T

41NTLK

424T 422T

---,�-+-,86Cl---�--41T

HR U 95 INTLK

65S INTLK

ANN. 401

BBC

13.BKV FE DER TO THE

4.16KV STATION SERVICE

TRANSFORMER "B"

MFP-OPN83E1401

-I I

I I I I I

41NTLK NEUTRAL 11G4 11G4 25A INTLK

86G

TRIP FROM AVR.

---l l f-__ __. ______ _, ---0-+-'=---------lc-k TO 2664 CIRCUIT

REACTOR 87X/AT2__,-t--i� 86P h-1---► ANN 404 87X/T5 H U 424T

DC/DC SUPPLY FAILURE

FIELD FLASHING DISTURBANCE

FIELD O.V. PROTECTIO

LOSS OF AVR. SUPPLY FUSE

EXCIT. TRANSF. OVER TEM

VR. SELECTOR SW. TEST POS

31 41

FLD. BKR. TRIP

FLD. BKR. CLOSE INTERLOCK

,------,-i--_ FLD. BKR. RECLOSE TIMER

L.C.L. ANN. 'TRIP SIGNALS'

EXCIT. MONITOR BLOCKING

86G

87X/B 31NTLK

49T4 65SNL INTLK

INTLK n

43GD4

21x-C

LTS

(INTLK WITH 1382)

--j f-RTU-0144

ATDA2

ATDB2

TDC2

772T 1572T 1672T 1382T

86P/G4 86P/G5 -------,.."='

ANN. 741

CUT-OFF SW.

BANK B

TRANSFORMER AT2

DA-FA-FA

230KV 40 533-66. 7MVA

115KV 40-53.3-667

1D4

1D5 TO G S ON

l-----cc=1�D'=

52/15 2, 52/1672, 52/772

M ATDA1

f-----< A TD B 1

ATDC1

- -ATCO

I

I 115KV TIC LINE

r-l--�11;3!J.8!!'KV;\LJ8!.11.:.1-1!QOJ!.8':.'.-1�3:J;.5[_��!j==#��:;==;��� CONT. ON DWG. 83E301 ANN 744

T

3-SOOMR-300/51'

3-600MR-4QQ&!-

3-600MR-400/5!-

ATA

,_-,__, _ft_ T M

ANN

: \_ 3-3000/5

·•IHIIII�

3-BOOMR-200/51'

3-600MR-400/5 Y

SGT

SCTG

UNIT 5 TRANSFORMER

36/48 MVA DA/FA 3•

230KV GRD Y-13.8KV1'

CTG

CT

«=--3 f-') ®LGT 1_ -

- MT RTU-014D

"1" 0------, 52/524 n-3�� 74 _l_ 3-

Tinu-0140

UNIT 5

o----J 52/522

1NEUTRAL

REACTOR

B

C A

AC GENERATOR

42, 105KV A, 095PF

13.BKV, 3• , 60 CYCLE

ANN. 742

86P/G4

M HR M 86P/G5

1672T

POLARIZING BUS 1572T CONTINUED ON 772T DWG. 83E301

1382T

ER

SYMBOLS

A AMMETER TR

ANN ANNUNCIATION

GL GEN. LOAD RECORDER

AS AMMETER SWITCH

ES EMERG. SHUTDOWN

F FREQUENCY INDICATOR

FM FL YBALL MOTOR TRC

VR-FR VOLT & FREQU. RECORDER UL

L LAMP SYNCHRONIZING V

M DRIVE MOTOR V••c

ML MASTER LOAD CONTROLLER VAR

PMG PERMANENT MAGNET GEN VR

SI SPEED INDICATOR VS

SL STATION LOAD RECORDER W

SS SYNCHRONIZING SWITCH WH

SYN SYNCHROSCOPE X

RTD RESIST. TEMP DETECTOR Y8Z

EMGD EASTERN MONTANA 4 GEN. DROP 11 TD TRANSDUCER

TS BRG. TEMP. SENSOR

TH THERMOSTAT

ENABLED GENERATOR

SEL-700G RELAY ELEMENTS

21 BACKUP DISTANCE

24 VOL TS PER HERTZ

25A AUTOMATIC SYNCHRONIZER

25CK SYNCH CHECK PERMISSIVE

27 UNDERVOLTAGE PERMISSIVE

32 REVERSE POWER

40 GEN. LOSS OF FIELD

46 GEN. NEGATIVE SEQUENCE

50 GEN. PHASE OVERCURRENT ALARM

59 GEN. OVERVOL TAGE

64G GENERATOR GROUND

64F FIELD GROUND

78 OUT OF STEP

81 OVERFREQUENCY PERMISSIVE

87 GEN. DIFFERENTIAL

INAD INADVERTENT ENERGIZATION

50BF BREAKER FAILURE DETECTION

ENABLED GSU

SEL-387E RELAY ELEMENTS

24 VOL TS PER HERTZ

27 UNDERVOL TAGE PERMISSIVE

51 N GSU NEUTRAL OVERCURRENT

51 GSU PHASE OVERCURRENT

87 GSU DIFFERENTIAL

KEY DIAGRAM

ULTIMATE INSTALLATION

TEMP RECORDER 12

AT AUTO-TRANSF.

B BEARINGS

F FIELD 13

S STATOR

T TRANSF. 14

TRANSFER CONTACTOR

UNIT LOAD RECORDER 15

VOLTMETER 20

VOLTAGE RECORDER 33B1

VARMETER

VOLTAGE REGULATOR 38

VOLTMETER SWITCH

WATTMETER

WATTHOUR METER

AUXILIARY RELAY 39

AUXILIARY RELAY 41

MASTER START-STOP RELAY 42

DIGITAL RELAY 43

G-GENERATOR 45

T-TRANSFORMER

OVERSPEED SWITCH

A-160%, B-120%, M-MOTOR

SPEED SWITCH

A-95%

UNDERSPEED SWITCH

A-50%

SPEED MATCHING

GEN. BRAKE VALVE

POSITION SWITCH

CLOSE BELOW SNL

BRG THERMAL DEVICE

GG-GEN GUIDE

GT-GEN THRUST

TG-TURBINE GUIDE

FIELD RED. CONTACTOR

FIELD ACB

CONTACTOR

SELECTOR SWITCH

DC OVERVOL TAGE RELAY

REFERENCES:

43GD

GEN. DROP SCHEME

SELECTOR SWITCH

4-GEN 4. 5-GEN. 5

2-GEN 2.

THERMAL RELAY

CIRCUIT BREAKER

PRESSURE RELAY

TB-TURB. BRG. OIL SOLENOID

,-SUDDEN, C-CO,

Q2-GOV. LOW OIL PRESSURE

GOVERNOR

L-SPEED-NO-LOAD

S-SHUTDOWN SOLENOID

SAM-SPEED ADJ. MOTOR

SHUTDOWN RELAY

C-COMPLETE

P-PARTIAL

DIFFERENTIAL RELAY

AT AUTO-TRANSF.

B BUS, G-GEN.

T TRANSF.

DISCONNECT SWITCH

TRIPPING RELAY

MFP-OPN83E302 POWERHOUSE 2 - SINGLE LINE DIAGRAM

NOTES:

1. GREEN/BOLD INDICATE EQUIPMENT TO BE REMOVED/MODIFIED.

US Army Corps of Engineers® z z

SHEET ID

ED601

VOLUME2

z ii':

u

C:

86P

SP

SP

SP

SP

11G4-IN304

ANN404

424T

SP

SP

SP

SP

11G4

SP

65SNL

86C

SP

SP

SP

SP

ANN401

11G4

SP

424T

SP

SP

SP

SP

65XA

41T

422T

SP

SP

SP

SP

SP

CO2

SP

SP

SP

SP

SP

SP

SP

SP

SP

87XG4

CO2

SP

86C

ANN402

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

OUT408

OUT407

OUT406

OUT405

OUT404

OUT403

OUT402

OUT401

OUT304

OUT303

OUT302

OUT301

OUT103

OUT102

OUT101IN101

IN102

IN301

IN302

IN303

IN304

COUNTER

D03

D04

BB

BB

D03

D04

CB

CB

BB

P406A

D02

BB

CB

CB

D01

D02

D01

CF CF

CE

CF

CG

BH

CH

BG

CH

BH

CH

BH

CH

CF CF

CF

CE CF

CG

BH

CF

BG

B I3

B I3

B I3

B I3

AO407-

BO402+ AO401+

AO407+

AO402+

B P

W R

B P

W R

BO407-

BO407+

B I1

B I3

B I3

B I1

B I1

BO401+

AO303-

AO301+

BO303-

AO303+

AO301-

86T

SP

BO301+

BO301-

BO402-AO402- BO401-AO401-

BO302-

AO302+

BO303+ BO302+

AO302-

N406A

CC

A12

D13

BC

D14

BC

A12

D13

CC

D14

A I3

A I3

A I1

A I3

A P

W R

A I3

A I3

A I1

A I3

BC

CC

A P

W R

A I1

A102

B102

1BF4

GENERATOR RELAYING

P424

URX

14 22

ANN 408C

ANN 408B

RED IND LT

42BV

42QP2

42QP1

42QP2

42OP1

63X

63X

ANN 417

SP

65X

COMPLETE SHUTDOWN

DIFFERENTIAL

42BFV

1C

20A

C1

20A

C04

C03

C02

C03

C04

C05

C06

C05

C06

C2

BE

BE

BF BF

BF BF

BF BF

SPARE

SPARE

13 14

62X

BF BF

87GX 86C

C01

A01

A02

A10

C10

C11

A11

C09

3 6

C12 C12

C13

C10

C11

C14

C01

C02

C13

C14

A01

A11

C09

A02

A10

R GG GR

11G4-IN304

R

STATUS

424A

1BF

25A

1DBC

SP

SP

TRBL ANN

BF ANN

CO2

B

A

F

E

63GBO

(12IB)

DB4G

R G

1DB4

11G4 (A&B)

86BF

SPD RAISE

86P

86C

SPD LOWER

52CLOSE

87XG4

VOLT RAISE

VOLT LOWER

25CK

25A ENABLE

F

G

B

C

B

G

B

C

F

16 28

C

F

G

RL

RTU

48 SP

SPSP

SP

SP

PPCS

65SAM

65SAM

20GSL

65GL

65GL

ANN

424-T

ER458

1 3

WES

C O

N T

IN

U E

D B

E L

O W

PARTIAL SHUTDOWN SYSTEM UNDER FREQUENCY

43MS/PPCS

RBI

F4

E4

RGWw

WLS C2

C1

81TD4

81TD4

SP

SP

AGLY1

4X3

52G

4 3

MSR

H1 13

C11

D11

AGLR

65XA

GLR3

SAML

SAM2

BPA

65XA

SAM1

SALF

65S

33-7X

G1

65GL

SP

SP

65S

YL

65S

C O

N T

IN

U E

D I

N

C

K T

C O

N T

IN

U E

D F

M A

B O

V E

AGLA

C1

D1

RAISE YR

AGLL

LOWER

86P

R

UCB

SNL

65S

4X3

SNU

SS

N406

R

R

P406

65X

3C 1

RG2

RG2

K01

C O

N T

IN

U E

D I

N

G

L C

K T

N406

81EX

RG/W

UFW

RG/E

81EX

L1

L2

UFE

C2

C1

RGEB

EAS

BLS

F3

E3

DEP

20DX2 43MS/LA

LCS

GO

3C

86P

R

43RAX 43RAX

RE4GD

P86-1

IPSR

86P

P86

4X3

2SD

65MS

65X

65X

SP

65MS

65X

337S

L2

337U

2SD

L1

C1

C2

86C

65XA

33-7X

65MS

SP

65S

SP

33-7X

86C

SP

SP

4 RED IND LT

4X

4 GRN IND LT

SP

63X

33-7X

2GTDO

20G

20G

SG SG

SG

SG

SG

L2

20G

2G

L1

63X

ANN 415

ANN 414

63X63X

ANN 422

C20

GATE LIMIT GEN. BRAKE SHUTDOWN INTERLOCK

DASHPOT UNIT RUN

SG

SG

33-7

63X

GIJ

SG

PE

URY

URY2

C1

C2

65X

GIE

GID

GIH

GIG

GIC

QIX

63TBX

TBWF

GGWX

GIA

63X

QIX

GIB

14A1

GB33

GB14

11C

33A1

C1

C2

URX

URY

URDL

URX

URWL

424B

1M

1A

W

20AI

L1

R

1A (AUTO)

GBM

GBRL

20AI

20AI

W

65SAM-1

33XY

RAISE

SAM1

SAMR

P406B

SAME

424A

LOWER

P406A

URX

R

BPD

W

UCB PM6

W

R

65S

L2

65GL

65X

GEN LIGHT

PMG LIGHT START

INST

SP

SP

SP

2SD

65GL

CO

GBWL

GBA

URX

GBN

TM2

TM1

TM2

TM3

START

ANN INTLK

TM1

TM3

TM1

TM2

4LX

63Q

Q4

GA

3HX

63Q

SG

SG

TBOP

3LX

63Q

IN

PWR

IN

IN

IN

OUT

11G4A

ADMISSION SYSTEM

AUTOMATIC AIR

MOTOR CONTROL

SPEED LEVEL ADJ.

D4 81T

OUT

11G4B

FX

TBW

SG

SG

FX

GCW

SG

SG

BAI

SG

SG

TBOX

SG

SG

TBOX

TGOF

SG

PX

TBO

SG

TGOL

QIX

(PADDLE)

CWF

63G

QI

SG

SG

G4

87X

RESET

HAND

87X

G4

86C

G4

86P

RESET

HAND

86C

OUT

11G4A

IN

(SEL700G)

11G4A

RESET

HAND

86P

OFF

1DBC4

ON

1DBC4

CLOSE

DEAD BUS

STARTING INTLK

OIL & WATER FLOW GOVERNOR

86P2BF

(SEL700G)

11G4B

86C

ON

1BF4 302

OUT

11G4A

OUT

11G4B

86P

IN

PWR

IN

IN

IN

OUT

11G4A

OUT

11G4B

B 87X

OUT

11G4B

IN

OUT

11G4A

OUT

11G4A

OUT

11G4B

52MOC1

OUT

11G4B

TURB BRG OIL PUMP

ON

81WCS

(FUTURE)

E

RE81

(FUTURE)

W

RE81

S1 4P

LM, LA

43MS

ON

81ECS

AT2

87X

424A

ACB

AT2

64X

W 43F

E 43F

P1 1L

PPCS

43MS

TDO

81TD5

RE65R

RE65L

P1 1A

YL

P1 1L

GL

TDC

2SD

YR

B1

INST

65X

BELOW 11.5%

CLOSED AT AND

G4 87X

2BF

86P

T4 87X

B2

4X

B1

SNL

(R2)

94LB2

4GD

43-

T4

41EX

T5 87X

4GDX

43-

P1

1ES

P2

1ES

RAX

4GDX

43-

RE5A

TG

GG

GT

SHUTDOWN

NORMAL

TDC

2SD

2SD

63QMSY

AS

3LX

63Q

INTERLOCK

MANUAL BRAKE

WF

63TB

FX

63GCW

WFX

63TS

TBWF

GA2

PX

TBO

MODE

CONDENSE

CRACKING

GATE

7X 33-

30 SEC

TDDO

RE15R

A

SAM2

MSY

MSX

S1 4P

LAPPCS

43MS

P1 1R

INST

2SD

P2 1L

P1 1L

GX

S3

SAM

98.5%

ABOVE

OPEN

MSX

BP

P2 1R

P2 1C

P1 1C

SAM

P1 1P

RE15R

THA

SG

SG

PREF AC

PP2

BKR 7

PP2

BKR 7

AIR INJECTION

ROUGH ZONE

23.5%

ABOVE

CLOSE

45%

ABOVE

AT &

OPEN

UX2

PREF AC

UX1

3H 71Q

3L 71Q

10"

BELOW

CLOSED

SW.1

MAG.

28.5"

ABOVE

CLOSED

SW.5

MAG.

63QA

63QB

LEVEL

TANK

LEVEL

TANK

LEVEL

SUMP

26"

ABOVE

CLOSED

SW.4

MAG.

AC

71Q3

18"

BELOW

OPEN

SW.3

MAG.

Q3L

CONTROL DIAGRAM UNIT 4

TURBINE & GOVERNOR

THEN HOLD FOR 6.5 MINUTES.

APPORX 1 MIN. AND 20 SEC. (6-8 CYCLES),

UNIT SPEED. BRAKES WILL CYCLE FOR

BRAKES WILL CYCLE AT AND BELOW 50%

- MULTIFUNCTION GENERATOR RELAY

- TIMER FOR AIR INJECTION

- AUX RELAY FOR 20 SOLENOID VALVE

- SOLENOID VALVE LOCATED ON ACTUATOR TANK

- TURBINE HEADCOVER SOLENOID AIR VALVE

- PARTIAL SHUTDOWN RESET (PSR)

- GATE POSITION SWITCH, CLOSED AT & BELOW 3% GATE

- GOV. TANK LOW OIL LEVEL AUX. RELAY

- GOV. TANK HIGH OIL LEVEL AUX. RELAY

- GOV. SUMP LOW OIL LEVEL AUX. RELAY

- GEN. AIR COOLING WATER FLOW SW.

- TURBINE BRG. COOLING WATER FLOW SW. AUX.

- GOV. LOW OIL PRESS. SW. AUX.

- TURBINE BRG. OIL RESERVOIR LEVEL SW. AUX.

- GEN. BRG. OIL RESERVOIR LEVEL AUX. SW.

- PACKING GLAND WATER FLOW SW.

- START INTERLOCK RELAY

- GOVERNOR BYPASS SOLENOID VALVE

- BRG. TEMP. & OIL SHUTDOWN AUX. RELAY

- GOV. GATE LIMIT ADJ. MOTOR

- DASHPOT TIME DELAY RELAY

- DASHPOT TIME DELAY RELAY

- GOV. SPEED ADJ. MOTOR

- GOV. SPEED-NO-LOAD SOLENOID

- GOV. SHUTDOWN SOLENOID (ACT. CAB.)

- GOV. SHUTDOWN AUX RELAY (ACT. CAB.)

- GOV. TANK AIR INJECTION CUTOUT (MAGNICATOR)

- ACCUMULATOR TANK OIL LEVEL SWITCH, AIR INJECT (MAGNICATOR)

- UNDER FREQUENCY TIME DELAY RELAY

- GENERATOR DIFFERENTIAL LOCKOUT RELAY

- VOLT. REG. EXCITATION TRIP RELAY

- UNIT RUN AUX. RELAY

11G1

2G

20G

20THA

33-7X

63Q3LX

63Q3HX

63Q4LX

63GCWFX

63TBWFX

63QIX

63TBOX

63TBOPX

63PGWF

63X

65BP

65X, XA

65GL

65MSX

65MSY

65SAM

65SNL

65SD

65SDX

71Q2AC

71Q2L

81TD

87X

K15

URX

3%

BELOW

AT AND

CLOSED

JUMP

TEMP

BKR 5 & 7

MCC 4

125V DC

(U5TB) (U5TB)

(U5TB)

(U5TB)

(U5TB)

(U5TB)

(U5TB)

T

1382BPCS

NC

OUT4

21-13B

U4P

B486P

BPB

BPA

(GOV.CAB.)

SSC

SLLB

SHUTDOWN SOLENOID

SPEED NO-LOAD &

DROPPING

E. GEN.

LEGEND

65S 43-5GDXRG2 RG/E RG/W

81TD

URY 65X 65XA 33-7X

2SD 63X

63TBWFX 63QIX 63TBOX 63Q3LX 63Q4LX

63Q3HX63TBOPX63GCWFX

20THO

1%

BELOW

@ AND

CLOSED

/86T86P

20AS - BRAKE SOLENOID

- PULSE LENGTH (ON-OFF) 4 SECONDS

6-8 CYCLES

- OPERATES FOR 1.5 MINUTES,

- OPERATES FOR 6.5 MINUTES

- OPERATING RELAY

TM3

TM2

TM1

20AI

REFERENCES:

MFP-OPN83E314A UNIT 4 - TURBINE AND GOVERNOR CONTROL SCHEMATIC

1. GREEN/BOLD INDICATE EQUIPMENT TO BE REMOVED/MODIFIED.

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

F

R

/1

ED602

E

M O

V A

L

U N

IT

T

U R

B

IN

E A

N D G

O V

E R

N O

R

V F P E

D .d g n

C O

N T

R O

L D

IA

G R

A M

J

R O

S E

N T

H A

L

S

K O

R O

B E

IN

IK

O V

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

O N

S T

E V

E N R

M

IL

E S P .E

K

A M

A N

K W

A -P

O

63X

4X34X2

11 11

R

SI

4X1

UCB

R

63X

PPCS

43MS

P405BP405A

4X1

63X

G RG

UCB

G

TDO

62X

4B7

4PS2

TDDO

62-1

URX

L1

4B5 4B6

L2

62X

62-2

4X3 4X3

1GA

62-1

4B8

P2

SSB

1UA

P1

1UA

4B3

4B1 4B2

1UA

RE5X

P1

86P

4E

4D

424B

422A

1UA

P2

4PS2

MRC

4L

43MS

B11I3

LM LA

RE1

B

43MS

B12

P405

B1

A1A12

PU11

43MS

A11I2

P1

1UA

43PSB

4H

4J

43PS43PS

G

R

AR

4B4

4N

UXBR

URA1

MXA

UXBG URB

URA

P405AB

UXTC

MRE

MRCA

P405D

P405C

4G

USSG

USSR

4SI

WITH 1GA

TBH2

4X1

2FH 43PSD

STRJ

STRD

48A

UXA2

48B

2WD1

74A

UR

74GA

P405E

INITIATION

11G4-IN304

11G4-IN304

43RAX

SPARE

SPARE

SPARE

SPARE

CF

SEQUENCE TRANSFER

N405

BF

BF CF

TDO

2FH

2WD

52GX

74G

2FH

20DX1

TDO

L1

L2

L1

L2

52GX

13A2

E1

F1

A1

PPCS

43MS

41EX-1

TB1-82

TB1-83

STRG

STRXB

86P

STRF

13-95X4

C2

A2

C1

A2

A1

P2

43PS

TDC

TDO

ANN410

TDO

SPARE

74G

SPARE

62TDO

2WD

GCWV

ACB422

SPARE

ACB422

65SAM

65SAM

2WD

ACB424

ACB424

65GL

65S

SPARE

G. LT.

R. LT.

ACB422C

41C

41T INTLK.

SPARE

62X

62X

SPARE

62 SEAL IN

SPARE

4 SEAL IN

EXCIT K88

74G

65S & 65SNL

4X

RE5X

20GSL

4-24

12A1

MRF

86C

MRG1 5

MRG

RE5X

C1

C2

RE5X

SPARE

SPARE

4-2

4B9

RE5X

RE5

RE1

41E

41E

VOLT ADJUST

VOLT ADJUST

ACB 424B INTLK.

EXC, K10

4X-1 SEAL IN

FIELD BREAKER

SPARE

SPARE

SPARE

SPARE

4GD

BVC

424T

86C

4GD

1UA-P2

WITH

RAX

PUMP START

TURB. BRG. OIL

11G4B

IN304

11G4A

IN304

OIL PUMP START

HP THRUST BRG.

OIL PUMP START

HP THRUST BRG.

VAL. OPEN

CLG. WATER

IN THE VOLTAGE REGULATOR.

-INDICATES CONNECTIONS TO TERMINAL BLOCK

VAL. CLOSED

CLG. WATER

WARNING HORN

FISHERMENS

S2

4P

S3

4P

S1

4P

HORN

TURBINE PIT

G

MASTER START-STOP PERMISSIVE START UNIT AUX. SHUTDOWN INCOMPLETE GEN. START ALARM AUTOMATIC SYNCHRONIZING PLANT 2 CONTROL

HORN

PIT

TURBINE

SEC.

1-30

TDPU

MIN.

1-10

TDPU

BKR 1 & 3

MCC 4

125V DC

20A

20A

(U15RW)

13A3

X

13-95

(U15RW) (U15RW)(U15RW)

C15

C16 C16

C15

UNIT 4 MASTER START-STOP CONTROL

LEGEND

REFERENCES:

MFP-OPN83E314B UNIT 4 - MASTER START/STOP CONTROL DIAGRAM

1. GREEN/BOLD INDICATE EQUIPMENT TO BE REMOVED/MODIFIED.

GEN. HEATER??

RE5X 4 4-2 4X1 4X3 62-2 62X 74G 4PS1 4PS3 13-95X

4X2 62-1 48 2FH

4PS2

- TIME DELAY OPEN

- PPCS MODE REMOTE ACCESS AUXILIARY RELAY

- PLANT 2 CONTROL TRANSFER RELAY

- MULTIFUNCTION GENERATOR RELAY

- PPCS

- SPEED AUX. RELAY

- GENERATOR START ALARM RELAY

- UNIT SHUTDOWN TIME RELAY

- UNIT START & SHUTDOWN AUX TIME DELAY RELAY

- INCOMPLETE START SEQUENCE TIME RELAY

- MASTER START/STOP RELAY

- START ALARM TIME DELAY

RE5X

13-95X

74G

62X

62-1,62-2

4-1,4-2,4X1,4X2

2FH

TDO

43RAX

4PS1,PS2, PS3

11G

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

F O

R T P

E C

K D

A M

M

IS

S O

U R I

R

IV

E R

P O

W E

R H

O U

S E

D

IG

IT

A L G

O V

E R

N O

R S

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

R T

L A

N D

O R

E G

F

R

/1

E

V E

N R

M

IL

E S P .E

ED603

J

R O

S E

N T

H A

L

R E

M O

V A

L

U N

IT

M

A S

T E

R S

T A

R T -S

T O

P

V F P E

D .d g n

C O

N T

R O

L D

IA

G R

A M

S

K O

R O

B E

IN

IK

O V

K

A M

A N

K W

A -P

O

2 2

P403B 2C

L

3 P1

1T

1 1CT

1C

RR

W

GG

A03

A04

R

52X

G

1 16

4PS2

50AP P403

403T

2C

1C

1C

422B

B

E

LS

52X

4C

2C

4 1T 4

P2

4C

3C

2C

4C

B03

11G4 IN101

B03

B04B04

11T4 IN101

43ITR

LCO ICLCO

52 RE94

LCO

LS2

LS1

LS2

LS1

SPARE

P402SJ

CH

402A

SPARE

A03

A04

(424)

(U4IB) (U4IB) (424)

BH

D09

D10 D10

D09

P402R

CB

BB CB

CHBH

FB

FBEB

BB

EB

T

88CSP

SP

7 SP

403G

3 SP

13 SP

7C

422B

3C

RTU 0403

SP

E453

LS2_______MOTOR CUTOFF SWITCH (BLACK)

LS1_______MOTOR CUTOFF SWITCH (BROWN)

AA________OPEN UNTIL FULLY CHARGED

LC________LATCH CHECK SWITCH

BB________CLOSED UNTIL FULLY CHARGED

SP

LEGEND

SP

SR________SOLENOID RELEASE (CLOSE COIL)

PS2_______CLOSED IN ALL EXCEPT BETWEEN "TEST" AND "CONNECT"

PS1_______OPEN IN ALL EXCEPT BETWEEN "TEST" AND "CONNECT"

11G_______DIGITAL MULTIFUNCTION RELAY

OUT405____AUTOSYNCHRONIZER CLOSE (25A)

OUT101____SYNCH CHECK RELAY (25CK)

M_________SPRING CHARGING MOTOR

ST________SHUNT TRIP

Y_________ANTI-PUMP RELAY

TOC_______TRUCK OPERATED CONTACT (POSITION SWITCH)

52________CIRCUIT BREAKER DEVICE

SP

N

L

P403W

UCB

10K

86C

4 4

52X

422ST

2C

50A

15A

403C

403R 9

L

UCB

422A

4C

422A

10A

75M

20A

P4O4

52X

3A

N4O3

20A

N4O4

20A

14 13

6 12 31

33B2

N402

SHUNT TRIP

52XY

86P86C

7 7

RE94

11 16

43-4GDX

4X1

K

94X

R4

TRIP COIL

GREEN LIGHT

SOLENOID RELEASE

POWER SYS STAB

230KV OC LINE RELAYS

POWER SYS STAB

P

Y

3 2

LC

B

A

Y

E451

N

TRIP COIL

E452

RG5

4PS1

SR

Y

R RR

P402G

M

ST

RG5

R E

S

F5

4PS1

GG W

E5

G

P402B

1 6

41EX-1

IT-P1

IT-P2

PS1

P402

P402A

P402C

P402C

RG4

1 1

SPARE SPARE

RG4

SPARE

TOC

RAX

L

E450

RTU04

65 4

SPARE

DT WTR DEPRESS

74G

65SAM

AUX

LM

TOC

TOC

LP1P1 P2

AUX

ICT

43MS

BB

L

TOC

AA

AUX

AUX

AA BB

SPARE

SPARE

SPARE

SPARE

86P

65 SAM

GEN BRAKE URX

CLOSE REMOTE

TEST TRIP/LOCAL

TEST CLOSE/LOCAL

SPARE

SPARE

TRIP REMOTE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

VOLT ADJ

52GX

41T INTLK

65MSX & MSY

65GL

424ST (NOT USED)

MOD 481

TC

OUT202

11T4B

OUT202

11T4A

AX

COIL

OUT

BLOW

SWITCH

CLUTCH

CC

PS…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .