FAKZ189102 TYPE B2 DRAWINGS.pdf
PDF 47 MB Posted
- Solicitation number
- W50S6N23B0003
About this file
This document provides a pre-solicitation notice for an upcoming Invitation for Bid for construction services at the 187th Fighter Wing in Montgomery, Alabama. The Department of the Army Alabama Army National Guard will issue an IFB on or about January 11, 2023 for construction of a 3,300 square foot addition and 1,300 square foot renovation to an existing Squadron Operations Building. The project scope includes sitework, building foundations, structural, architectural, plumbing, mechanical and electrical work to construct a new two-story addition and modify existing spaces. The project is estimated to cost between $1-5 million and have a 365 day period of performance once a notice to proceed is issued. The NAICS code is 236220 for commercial and institutional building construction with a $39.5 million small business size standard. This procurement is set aside solely for small businesses. A pre-bid conference will be held and bids must be submitted in response to the forthcoming IFB solicitation.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S o u th
C o u rt
S tr ee t
M o n tg o m er y, A
L
T el
. 3 . 5
W W
W .S
S L
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
T1.0
TITLE SHEET
F -3
A
D A
L S
Q U
A D
R O
N O
P E
R A
T
IO
N S B
U
IL
D
IN
G
D A
N N
E L
L Y
F
IE
L D
M O
N T
G O
M E
R Y
A
L A
B A
M A
10065.02
JUNE 2022
ME, DCD
DCD
F-35: ADAL Squadron Operations Building 1303
Montgomery, AL
FAKZ 189102
187th Fighter Wing Dannelly Field -
AL ANG
ARCHITECTURALCIVIL STRUCTURAL MECHANICAL ELECTRICAL
SEAY SEAY & LITCHFIELD, P.C.
1115 SOUTH COURT STREET
MONTGOMERY, AL 36104
334-263-5162
PROFESSIONAL ENGINEERING CONSULTANTS
822 S MCDONGOUGH STREET
MONTGOMERY AL, 36104
334-262-7307
BLACKBURN DANIELS O'BARR
8805 COUNTY RD 40 E
LOWNDESBORO, AL 36752
334-265-0206
HHB ENGINEERS
104 JOSIE RUN
PRATTVILLE, AL 36066
334-358-2707
GUNN & ASSOCIATES, P.C.
3102 HIGHWAY 14
MILLBROOK, AL 36054
334-285-1273
Approvals:
Title: Signature: Date:
Base Commander
Base Civil Engineer
Base Project Engineer
Bio Environmental Eng.
Safety
Security Police
Base Communications
Fire Chief
Schedule of Bid Options:
No. Revision Date
Option #1 Generator
Option #2 Landscape Furniture
ACT ACOUSTICAL CEILING TILE
A/C AIR CONDITIONING
AB ANCHOR BOLT
ADA AMERICAN DISABILITIES ACT
AFF ABOVE FINISH FLOOR
BM BEAM
BRG BEARING
BRK BRICK
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CIP CAST IN PLACE
CJ CONTROL JOINT
CL COLUMN LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CONTR CONTRACTOR
COORDF COORDINATION
CORR CORRIDOR
CT CERAMIC TILE
CTR CENTER
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DR DRAIN
DN DOWN
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWR DRAWER
EA EACH
EF EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EQ EQUAL
EX EXISTING
EXT EXTERIOR
FF FINISH FLOOR
FIN FINISH
FL FLOOR LINE
FLSNG FLASHING
FTG FOOTING
GA GAUGE
GFRC GLASS FIBER REINFORCED CONCRETE
GWB GWB
HT HEIGHT
HM HOLLOW METAL
HOR HORIZONTAL
HR HANDRAIL
HTR HEATER
HVAC HEATING, VENTILATION & AIR CONDITIONING
HXWXL HEIGHT, WIDTH, LENGTH
IN INCHES
INSUL INSULATION
INT INTERIOR
JST JOIST
ABBREVIATIONS
JT JOINT
LAM LAMINATE
LAV LAVATORY
LVR LOUVER
MIN MINIMUM
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MH MAN HOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOULDING
MO MASONRY OPENING
MTD MOUNTED
MW MICROWAVE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OPP OPPOSITE
P PAINT
PL PLATE / PROPERTY LINE
PL LAM PLASTIC LAMINATE
PLYWD PLYWOOD
PNL PANEL
PT PRESSURE TREATED
R RADIUS / RISER
RB RUBBER BASE
REFR REFRIGERATOR
REINF REINFORCE (D)
REV REVISED
RM ROOM
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SHW SINGLE HUNG WINDOW
SIM SIMILAR
SPECS SPECIFICATIONS
SQ SQUARE
SS SANITARY SEWER
STD STANDARD
SVT SOLID VINYL TILE
STL STEEL
T TILE
T&G TONGUE & GROOVE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
WD WOOD
WWM WELDED WIRE MESH
WWF WELDED WIRE FABRIC
YP YELLOW PINE
SYMBOLS LEGEND
A101
SIM
A101
SIM
A101
ROOM NAME
150 SF
A101
SIM
1i
1t x
X
SPECIFIC NOTE TAG
DOOR TAG
WINDOW TAG
WALL TAG
STOREFRONT TAG
GLAZING TAG
SPOT ELEVATION
ROOM TAG
ELEVATION TAG
BUILDING SECTION
WALL SECTION
DETAIL
ADA TURNING RADIUS
1Ref
R e f
1 Ref
R e f
X
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S o u th
C o u rt
S tr ee t
M o n tg o m er y, A
L
T el
. 3 . 5
W W W .S S L A R C H .C O M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
T2.0
GENERAL NOTES,
ABBREVIATIONS, &
INDEX TO
DRAWINGS
F -3
A
D A
L S
Q U
A D
R O
N O
P E
R A
T
IO
N S B
U
IL
D
IN
G
D A
N N
E L
L Y
F
IE
L D
M O
N T
G O
M E
R Y
A
L A
B A
M A
10065.02
JUNE 2022
ME, DCD
DCD
GENERAL NOTES APPLY TO THE ENTIRE PROJECT. SPECIFIC NOTES APPLY TO ISOLATED WORK AREAS AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR. HOWEVER, ALL ISOLATED WORK AREAS ARE NOT NOTED. SHOULD A CONDITION OCCUR THAT IS NOT SPECIFICALLY NOTED, THE CONTRACTOR SHALL PROCEED WITH WORK PER GENERAL DEMOLITION NOTES OR A SPECIFIC WORK NOTE(S) USED IN OTHER SIMILAR CONDITIONS, WHICHEVER IS MORE STRINGENT, PER APPROVAL OF ARCHITECT.
1. CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY IF THERE ARE ANY DISCREPANCIES WITH TAGGED DETAILS, ENLARGED PLANS, ELEVATIONS, ETC.
2. CONTRACTOR TO CONFIRM ALL OSHA AND APPLICABLE STANDARDS TO ASSURE SAFETY OF ALL PERSONS ON SITE DURING
ENTIRE COURSE OF CONSTRUCTION.
3. CONTRACTOR TO VERIFY ALL FINISHED DIMENSIONS BEFORE INSTALLATION OF CABINET WORK AND TRIMWORK.
4. CONTRACTOR TO VERIFY APPLICABLE OPENINGS, DOOR SIZES, AND DIMENSIONS OF MECHANICAL ROOMS WITH EQUIPMENT. IF
DISCREPANCY OCCURS, NOTIFY ARCHITECT PRIOR TO FRAMING.
5. CONTRACTOR TO COORDINATE PLUMBING AND MECHANICAL LINES WITH CEILING HEIGHTS, ABOVE CEILING AREAS AND
STRUCTURAL ELEMENTS.
6. CONTRACTOR TO VERIFY WITH STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL THE QUANTITY AND SIZES OF ALL SLEEVES REQUIRED. ALL SLEEVES TO BE ONE HOUR RATED, PROVIDE GREATER RATING IF PENETRATING INTO HIGHER RATED
ASSEMBLY.
7. COORDINATE CONDUIT, PIPING, AND DUCTWORK SO THAT THE HEAD HEIGHT IS NOT ENCUMBERED AND SERVICES ARE AS TIGHT
UP TO STRUCTURE AS POSSIBLE.
8. CONTRACTOR TO COORDINATE PLUMBING, MECHANICAL, FIRE SPRINKLER, ELECTRICAL, AND LIGHTING WITH STRUCTURAL ELEMENTS WHERE THERE IS EXPOSED STRUCTURE. CONDUIT LINES, ETC. SHALL RUN AT RIGHT ANGLES OR SEGMENTED
BETWEEN COLUMN LINES AND BE CLEAN AND NEAT IN APPEARANCE.
9. COORDINATE LOCATION OF SWITCHES, OUTLETS, THERMOSTATS, LIGHTS, ETC. W/ SHELVING, TRIM, MARKER BOARDS, AND CABINETRY. MOVE AS REQUIRED TO MISS SHELVING, STORAGE, CASEWORK, VISUAL DISPLAY BOARDS.
10. REFER TO MECHANICAL FOR ADDITIONAL LOUVERS NOT TAGGED.
11. COORDINATE CONDUIT, PIPING, AND DUCTWORK SO THAT HEAD HEIGHT IS NOT ENCUMBERED AND SERVICES ARE AS TIGHT UP TO STRUCTURE AS POSSIBLE, THIS WILL INCLUDE JOGGING DUCTS, SPRINKLER LINES, PLUMBING LINES, CONDUIT, ETC. UP AND DOWN OR AROUND AS REQUIRED TO ACHIEVE CEILING HEIGHTS AS INDICATED. COORDINATE INSTALLATION AND SEQUENCING
OF DISCIPLINES TO ACHIEVE.
12. THE GENERAL CONTRACTOR SHALL STAKE OUT ALL MAJOR FEATURES SHOWN ON THE SITE PLAN TO VERIFY THE SITE LAYOUT RELATIVE TO THE PROPERTY LINES AND SITE CONDITIONS PRIOR TO ANY UTILITIES OR FOOTINGS BEING INSTALLED.
13. ALL RECESSED ACCESSORIES LOCATED IN FIRE RATED WALLS SHALL BE EITHER OF FIRE RATED CONSTRUCTION OR COORDINATED WITH THE ADJACENT TRADES TO ALLOW THE GYPSUM BOARD TO BE CONTINUOUS BEHIND THE ACCESSORIES.
14. REFER TO CONTRACT DOCUMENTS FOR CONCEALED WOOD BLOCKING REQUIREMENTS.
15. COORDINATE FINAL CEILING HEIGHT WITH ALL WINDOWS. ALL TRADES SHOULD BE ABLE TO FIT WITHIN THE ALLOTTED SPACE IF COORDINATED BY THE GENERAL CONTRACTOR AND EACH TRADE. IF FURR DOWNS ARE REQUIRED TO ACCOMMODATE ABOVE CEILING ITEMS, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE FURR DOWNS AND COORDINATE LOCATIONS WITH THE
ARCHITECT.
INDEX TO DRAWINGS
SHEET NO. SHEET NAME
E3.4 SECOND FLOOR PLAN - MECHANICAL POWER
E4.1 FIRST FLOOR PLAN - AUXILIARY SYSTEMS
E4.2 SECOND FLOOR PLAN - AUXILIARY SYSTEMS
E4.3 FIRST FLOOR PLAN - SECURITY AND ACCESS CONTROL
E4.4 COMMUNICATIONS DETAILS
E4.4A COMMUNICATIONS OUTLET CONFIGURATIONS
E4.4B COMMUNICATIONS OUTLET CONFIGURATIONS
E4.5 COMMUNICATIONS GROUNDING DETAILS & NOTES
E4.6 COMMUNICATIONS CABLING MATRIX AND ROUTING
REQUIREMENTS
E4.7 COMMUNICATIONS CABLING MATRIX AND ROUTING
REQUIREMENTS (CONT'D)
E4.8 COMMUNICCATIONS CABLING MATRIX AND ROUTING
REQUIREMENTS (CONT'D)
E5.1 LUMINAIRE SCHEDULE, DETAILS & NOTES
E5.2 PANELBOARD SCHEDULES, DETAILS & NOTES
E5.3 PANELBOARD SCHEDULES
E5.4 PANELBOARD SCHEDULES
E5.5 PANELBOARD SCHEDULES
E6.1 FIRE ALARM / MASS NOTIFICATION SYSTEM RISER,
DETAILS & NOTES
E6.2 CABLE TRAY REQUIREMENTS
E6.3 ACCESS CONTROL DOOR ROUGH-IN DETAILS & NOTES
E7.1 SINGLE LINE DIAGRAM - POWER
E7.2 GENERATOR DETAILS & NOTES (BID OPTION)
E7.3 GENERATOR DETAILS & NOTES (BID OPTION)
Grand total: 105
INDEX TO DRAWINGS
SHEET NO. SHEET NAME
M2.2 HVAC - FIRST FLOOR PLAN - SECTOR B
M2.3 HVAC - FIRST FLOOR PLAN - AUS SERVER ROOM S16
M2.4 HVAC - SECOND FLOOR PLAN
08 Electrical
E0.1 ELECTRICAL LEGEND & NOTES
E0.2 ELECTRICAL LEGEND & NOTES (CONT'D)
E1.1 SITE PLAN - ELECTRICAL
E1.2 LIGHTNING PROTECTION SYSTEM DETAILS & NOTES
E1.3 FIRST FLOOR PLAN LIGHTING DEMOLITION
E1.4 SECOND FLOOR PLAN - LIGHTING DEMOLITION
E1.5 FIRST FLOOR PLAN - POWER DEMOLITION
E1.6 SECOND FLOOR PLAN - POWER DEMOLITION
E1.7 SECOND FLOOR PLAN - MECHANICAL POWER
DEMOLITION
E1.8 SECOND FLOOR PLAN - MECHANICAL POWER
DEMOLITION
E1.9 FIRST FLOOR PLAN - AUXILIARY DEMOLITION
E1.10 SECOND FLOOR PLAN - AUXILIARY DEMOLITION
E1.11 FIRST FLOOR PLAN - SECUFITY AND ACCESS CONTROL
- DEMOLITION
E2.1 FIRST FLOOR PLAN - LIGHTING
E2.2 SECOND FLOOR PLAN - NEW LIGHTING
E3.1 FIRST FLOOR PLAN - POWER
E3.2 SECOND FLOOR PLAN - POWER
E3.3 FIRST FLOOR PLAN - MECHANICAL POWER
INDEX TO DRAWINGS
SHEET NO. SHEET NAME
R1.2 REFERENCE SHEET - EXISTING FIRE PROTECTION
R1.3 REFERENCE SHEET - EXISTING FIRE PROTECTION
04B FIRE PROTECTION
FP1.1 LEVEL 1 FIRE PROTECTION DEMOLITION FLOOR PLAN
FP2.1 LEVEL 1 FIRE PROTECTION FLOOR PLAN
FP2.2 LEVEL 2 FIRE PORTECTION FLOOR PLAN
05 Structural
S0.1 GENERAL NOTES-SCHEDULES-TYPICAL DETAILS
S0.2 TYPICAL DETAILS
S1.1 PARTIAL FIRST FLOOR AND FOUNDATION & SECOND
FLOOR / LOW ROOF FRAMING PLANS
S1.2 PARTIAL ROOF FRAMING PLAN
S2.1 SECTIONS AND DETAILS
S2.2 SECTIONS AND DETAILS
S2.3 SECTIONS AND DETAILS
06 Plumbing
P1.1 LEVEL 1 PLUMBING DEMOLITION FLOOR PLAN
07 Mechanical
M0.1 MECHANICAL GENERAL NOTES, ABBREVIATIONS, AND
LEGEND
M0.2 MECHANICAL SCHEDULES
M0.3 MECHANICAL DETAILS
M0.4 MECHANICAL DETAILS
M1.1 HVAC - FIRST FLOOR PLAN - SECTOR A - DEMOLITION
M2.1 HVAC - FIRST FLOOR PLAN - SECTOR A
INDEX TO DRAWINGS
SHEET NO. SHEET NAME
A1.2 LEVEL 2 DEMOLITION PLAN
A1.3 DEMOLITION ELEVATIONS
A2.1 LEVEL 1 FLOOR PLAN
A2.2 LEVEL 2 FLOOR PLAN
A2.3 LEVEL 1 WALL TYPE / DIMENSION PLAN
A2.4 LEVEL 2 WALL TYPE / DIMENSION PLAN
A2.5 INTERIOR WALL DETAILS
A2.6 ROOF PLAN
A3.0 FINISH SCHEDULE
A3.1 DOOR SCHEDULES & NOTES
A3.2 SIGNAGE SCHEDULE & DOOR DETAILS
A3.3 DOOR DETAILS
A3.4 GLAZED OPENING SCHEDULE
A3.5 GLAZED OPENING DETAILS
A3.6 GLAZED OPENING DETAILS
A4.1 EXTERIOR ELEVATIONS
A5.0 BUILDING SECTION
A5.1 WALL SECTIONS
A5.2 WALL SECTIONS
A5.3 DETAILS
A7.1 INTERIOR DETAILS
A8.1 REFLECTED CEILING PLAN
A8.2 REFLECTED CEILING PLAN
04A FIRE PROTECTION
R1.1 REFERENCE SHEET - EXISTING FIRE PROTECTION
INDEX TO DRAWINGS
SHEET NO. SHEET NAME
00 Title
T1.0 TITLE SHEET
T2.0 GENERAL NOTES, ABBREVIATIONS, & INDEX TO
DRAWINGS
T2.1 ADA MOUNTING HEIGHTS
01 Civil
C1.1 SITE DEMOLITION PLAN
C2.1 SITE LAYOUT PLAN
C3.1 SITE GRADING AND DRAINAGE PLAN
C4.1 SITE UTILITIES PLAN
C5.1 SITE EROSION & SEDIMENT CONTROL PLAN
C6.1 SITE DETAILS
C7.1 SITE DETAILS
C8.1 SITE DETAILS
C9.1 SITE DETAILS
02 LANDSCAPE
L0.1 LANDSCAPE PLAN
L1.0 ENLARGED LANDSCAPE SITE PLAN & DETAILS
02.1 LIFE SAFETY
LS1.0 LIFE SAFETY CALCULATIONS
LS1.1 LIFE SAFETY PLANS
03 Architectural
A0.1 PHASING PLAN
A1.0 DEMOLITION NOTES
A1.1 LEVEL 1 DEMOLITION PLAN
GENERAL NOTES
16. CONTRACTOR TO VERIFY ALL DIMENSIONS AND FIELD CONDITIONS WITH THE DRAWINGS, IN PARTICULAR: WALL DIMENSIONS, INCOMING UTILITIES, ETC. REPORT IMMEDIATELY TO THE ARCHITECT ANY VARIANCES OR FIELD CONDITIONS THAT MAY CAUSE
CONSTRUCTION PROBLEMS PRIOR TO COMMENCING WORK.
17. ALL MATERIAL SPECIFIED IS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS.
TRADE CONTRACTORS ARE TO CONSTRUCT PROJECT IN ACCORDANCE WITH THE DOCUMENTS. ANY DEVIATION FROM THE INTENT OF THE DOCUMENTS WITHOUT ARCHITECT'S APPROVAL ARE AT THE TRADE CONTRACTOR'S RISK AND MAY RESULT IN
WORK BEING REWORKED AT THE TRADE CONTRACTOR'S EXPENSE. (MATERIAL AND LABOR)
18. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS, INSPECTIONS, AND CERTIFICATES REQUIRED BY GOVERNING ENTITIES.
19. PROMPTLY NOTIFY THE ARCHITECT IN WRITING IF ANY CONTRACT DOCUMENTS ARE FOUND TO BE IN VARIANCE WITH THE APPLICABLE LAWS AND ORDINANCES. NECESSARY CHANGES WILL BE MADE BY APPROPRIATE MODIFICATIONS.
20. IF ANY WORK IS PERFORMED KNOWING IT TO BE CONTRARY TO SUCH CODES, LAWS, ORDINANCES, RULES AND REGULATIONS, AND WITHOUT NOTICE TO THE ARCHITECT, THAT TRADE CONTRACTOR ASSUMES FULL RESPONSIBILITY AND BEARS COSTS ATTRIBUTED TO BRING WORK TO COMPLIANCE OF SUCH CODES, LAWS, ORDINANCES, AND RULES AND REGULATIONS.
21. EACH RESPONSIBLE CONTRACTOR SHALL SEAL ALL PENETRATIONS MADE AS PART OF THEIR WORK IN FIRE-RATED CONSTRUCTION AS REQUIRED BY ALL APPLICABLE CODES. EACH CONTRACTOR TO VERIFY WITH LOCAL FIRE MARSHAL OR BUILDING OFFICIAL HAVING JURISDICTION. EACH RESPONSIBLE CONTRACTOR WILL SEAL ALL PENETRATIONS MADE AS PART OF THEIR WORK THROUGH NON-RATED PARTITIONS. ALL FIRE CAULK TO BE THE SAME BRAND AS DETERMINED BY CONTRACTOR.
22. PLUMBING, FIRE-PROTECTION, MECHANICAL, AND ELECTRICAL WORK REQUIRED BY THIS CONTRACT IS NOTED ON CONTRACT DOCUMENTS. THE TRADE CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF THEIR WORK WITH ALL TRADES.
CHANGE ORDERS SHALL NOT BE APPROVED FOR EXTRA WORK ARISING FROM TRADE CONTRACTORS NOT COORDINATING WORK.
23. NEITHER THE ARCHITECT, NOR THE OWNER SHALL BE RESPONSIBLE FOR JOB SAFETY. EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SITE SAFETY AND SAFETY OF THE PUBLIC DURING CONSTRUCTION AND SHALL PROVIDE APPROPRIATE
WARNINGS, BARRICADES, ETC. AS REQUIRED PER CODES.
24. CONTRACTOR WILL BE RESPONSIBLE FOR ALL LAYOUT FOR INTERIOR/EXTERIOR WALLS AND FOUNDATION AND WILL BE RESPONSIBLE FOR MAINTAINING A BENCHMARK AND CONTROL LINES AT EACH FLOOR LEVEL. CONTRACTOR IS ALSO RESPONSIBLE FOR VERIFYING ACTUAL FLOOR HEIGHTS AND COORDINATING NEW AND EXISTING FLOORS TO ALIGN.
25. EACH TRADE CONTRACTOR WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLING CEILING OR WALL-MOUNTED ACCESS DOORS AS REQUIRED TO ACCESS COMPONENTS OF ITS SYSTEM AND TO COORDINATE WITH OTHER TRADES SO ACCESS IS
MAINTAINED.
26. IN ROOMS WITH FLOOR DRAINS, SLOPE TO DRAINS @ 1% SLOPE.
27. COORDINATE WITH OWNER LOCATION TO TELEVISION TO PROVIDE WOOD BLOCKING AT OWNER SPECIFIED LOCATION.
No. Revision Date
M
A X
" M A X
" M
IN
PAPER TOWEL
DISPENSER
MIRROR
SOAP
DISPENSER
ROBE
HOOK
TO
T
O P
O F
H O
O K
" T
YP
LAVATORY. PROVIDE ADA
INSULATION KIT WHEN REQUIRED
URINAL
42" MIN
MAX
1' - 0"
" M
IN
" M
IN
" M
IN
" M
IN
WATER
CLOSET
TOILET
PAPER
DISPENSER
SANITARY
NAPKIN
DISPOSAL
HORIZONTAL
GRAB BAR
VERTICAL GRAB BAR
MIN
1' - 3"
39 MIN - 41 MAX
" A B O
V E
FI
N
IS
H
ED
F
LO
O R
SHOWER ROD
FOLDING SHOWER SEAT FOR
TRANSFER-TYPE SHOWERS. LOCATE
ON WALL OPPOSITE THE CONTROLS
AND HAND SHOWER WALL.
TOWEL BAR
ALLOWABLE
MOUNTING
AREA
TO
B
O
TT
O M
O F
RE
FL
EC
TI
V E
S U
RF
AC
E
" M A X
H A
FF
M
IN
M A X
H A
FF
M
IN
M
AX
ACAL
MAX.
15"
MAX.
15"
" M
IN
" M A X
CONTROLS AND HAND
SHOWER SHALL BE
LOCATED WITHIN HATCH
AREA
HAND SHOWER GLIDE
RAIL NOT SHOWN,
SEE SPECS
TRANSFER SHOWER CONTROL WALL
LOCATED OPPOSITE SEAT WALL.
4" MAX.
18"
" M A X
/2 " M
AX
1 1/2" MAX.
22" - 23"
15" - 16"
" M
A X
O F
C O
M
PA
TM
EN
T
EN
TR
Y
AL-SHAPED
SHOWER
SEAT
16" - 18"
M
IN
M
AX
12 MIN
36 MIN.
HORIZONTAL
GRAB BAR
" M A X
A D
A M
AX
" M
AX
FIRE
EXTINGUISHER
CABINET
" M
AX6
" M
IN
ADA ELECTRIC
WATER COOLER
DIRECTION INDICATOR
HALL CALL
CONTROLS
ELEVATOR DOOR
H A
FF
" M
IN
" M
A X.
M
IN
" M
IN
MIN.
8"
" M
AX
6" MAX.
11" MIN
ACAL
5" MAX. 15" MIN.
MIN. CLEAR DEPTH
48"
M
IN
C
LE
AR
W
ID
TH
2 1/2" MAX
" M
AX
/2 " M
A X
15-16"
60" MIN
" M
IN
" M
IN
3" MAX
" M
AX
M
IN
M
AX
" M A X
2' - 0"
27" MAX
" M
AX
FOLDING SHOWER SEAT FOR
TRANSFER-TYPE SHOWERS. LOCATE
ON WALL OPPOSITE THE CONTROLS
AND HAND SHOWER WALL.
CONTROLS AND HAND SHOWER
SHALL BE LOCATED WITHIN
HATCH AREA
STANDARD ROLL-IN TYPE SHOWER
COMPARTMENT SIZE AND CLEARANCE
M
IN
MIN
18"
M
IN
MIN
36"
FRONT APPROACH, PULL SIDE
HINGE APPROACH, PULL SIDE
M
IN
MIN
24"
LATCH APPROACH, PULL SIDE
M
IN
MIN
42"
HINGE APPROACH, PULL SIDE
M
IN
" MIN
12"
FRONT APPROACH, PULL SIDE
M
IN
FRONT APPROACH, SLIDING DOORS AND
FOLDING DOORS
M
IN
" MIN
22"
HINGE APPROACH, PUSH SIDE
M
IN
SLIDE SIDE APPROACH, SLIDING
DOORS AND FOLDING DOORS
MIN
54"
M
IN
LATCH APPROACH, PUSH SIDE
MIN
24"
M
IN
MIN
24"
LATCH SIDE APPROACH, SLIDING
DOORS AND FOLDING DOORS
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T2.1
ADA MOUNTING
HEIGHTS
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
1/2" = 1'-0"T2.1
1 TYPICAL MOUNTING HEIGHTS UNLESS NOTED OTHERWISE
1/2" = 1'-0"T2.1
3 TYPICAL MOUNTING HEIGHTS UNLESS NOTED OTHERWISE CONTINUED
1/2" = 1'-0"T2.1 2 TYPICAL MOUNTING HEIGHTS UNLESS NOTED OTHERWISE CONTINUED Copy 1
1/4" = 1'-0"T2.1
4 ADA DOOR OPENING MANEUVERING CLEARANCES
1. ADA STANDARDS FOR ACCESSIBLE DESIGN AND ICC/ANSI A117.1 ARE
THE REFERENCE STANDARDS USED FOR SCOOPING PROVISIONS FOR
ACCESSIBILITY. THE MORE STRINGENT PROVISIONS OF THE TWO
STANDARDS ARE INDICATED.
2. DIAGRAMS SHOWN ARE FOR MOUNTING HEIGHT INFORMATION ONLY.
FIXTURES SHOWN ARE NOT NECESSARILY INCLUDED IN THE PROJECT.
3. COORDINATE ADA REQUIREMENTS WITH ALL REQUIRED CONCEALED
WOOD BLOCKING.
4. REFER TO MANUFACTURER'S LITERATURE REGARDING RECOMMENDATIONS
FOR MOUNTING PRODUCTS AND MATERIALS IN COMPLIANCE WITH ADA
STANDARDS.
GENERAL NOTES:
CREPE M
YRTLE
CREPE M
YRTLE
x x x xx x xxx x x x
AMU BUILDING
BLDG 1109
BLDG 1203
EXISTING SQUADRON
OPERATIONS BLDG 1301
BASE SUPPLY
ADDITION
SQUADRON OPERATIONS
ADDITION
L1.0
L1.0
A1.3
LEGEND:
NEW CONCRETE CURB AND GUTTER - REFER TO CIVIL
PLANS & SPECIFICATIONS
NEW CONCRETE SIDEWALK / PAVEMENT - REFER TO CIVIL
PLANS & SPECIFICATIONS
INDICATES AREAS TO RELEIVE SOD.
PROJECT LIMITS
1 SPECIFIC NOTES TAG
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
L0.1
LANDSCAPE PLAN
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
1" = 30'-0"L0.1
1 LANDSCAPE PLAN
No. Revision Date
SPECIFIC NOTES:
1 PROVIDE CAST STONE BENCH WITH WOOD
BACKREST SEAT - SEE SECTION
EQUAL TO LANDSCAPE FORMS UNIVERSE
SYSTEM BACKLESS (25" AND 71" UNITS)
CASTSTONE BENCH EQUAL TO
SOCRATES BY LANDSCAPE FORMS
PAVERS - SEE SPECS
SAND LEVELING BED
CONCRETE PAVING
BASE - SEE CIVIL
LIME-STABILIZED SUBGRADE
PEJ
CURB AND GUTTER - SEE CIVIL
ASPHALT PAVING - SEE CIVIL
3/4" CHAMFER TYPICAL
WIDTH VARIESVARIES
STAMMPED CONCRETE BORDER CURB
S E E C
IV
IL
LIME-STABILIZED SUBGRADE
EXISTING SUBGRADE
ALTERNATE BASE BID
CONCRETE PAVER
BASE
EXPANSION JOINT
LIME-STABILIZED
SUBGRADE
EXISTING SUBGRADE
PAVERS (SEE SPECS)
SAND LEVELING BED
CONCRETE BORDER CURB
EXPANSION JOINT
CONCRETE PAVING
CONCRETE
24"24"
M
IN
IM
U M
MAX
8' - 0" O.C.
M in im u m
/8
M
IN
COMPOSITE POST CAP
COMPOSITE TOP RAIL
COMPOSITE INTERLOCKING PICKET
COMPOSITE INTERMEDIATE RAIL
COVER AND ALUMINIUM RAIL
3.5" X 3.5" X 3/16"
GALVANIZED STEEL POST
COMPOSITE FENCE POST
COMPOSITE BOTTOM RAIL
COVER
CONCRETE FOUNDATION
NOT TO SCALE
COMPOSITE POST CAP
COMPOSITE FENCE POST
COMPOSITE TOP RAIL
COMPOSITE INTERLOCKING
PICKET
ALUMINIUM BOTTOM RAIL
FENCE BRACKET
COMPOSITE BOTTOM RAIL
COVER
M
IN
COMPOSITE INTERLOCKING PICKET
A S R
E Q
U
IR
E D
B Y F
E N C
E M
A N U F A C
T U R E R
EQ EQ
0' - 0 1/2"
EQ EQ
WRAP MASONRY AROUND JAMBS (TYPICAL)
GATES - PROVIDE DIAGONAL BRACING AS REQUIRED
HEAVY DUTY BALL BEARING HINGES
BY GATE MANUFACTURER
SLIDE BOLT BY GATE MANUFACTURER
CANE BOLT BY GATE MANUFACTURER
RECESSED STRIKE EMBEDDED IN CONCRETE (TYPICAL)
0' - 6" 0' - 6"
SEE PLAN
0' - 6"
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S o u th
C o u rt
S tr ee t
M o n tg o m er y, A
L
T el
. 3
. 2
. 5
W W W .S S L A R C H .C O M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E
SI
G N
L1.0
ENLARGED
LANDSCAPE SITE
PLAN & DETAILS
F -3
5:
A
D A
L S
Q U
A D
R O
N O
P E
R A
T
IO
N S B
U
IL
D
IN
G
D A
N N
E L
L Y
F
IE
L D
M O
N T
G O
M E
R Y
, A L
A B
A M
A
10065.02
JUNE 2022
ME, DCD
DCD
1" = 1'-0"L1.0
4 RAISED PLANTER SECTION - BID OPTION
1 1/2" = 1'-0"L1.0
3 TYPICAL CONCRETE WALK WITH INTERIOR BRICK
1/2" = 1'-0"L1.0
1 COMPOSITE FENCE DETAIL
1/2" = 1'-0"L1.0
2 DUMPSTER GATE DETAIL
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
LS1.0
LIFE SAFETY
CALCULATIONS
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
APPLICABLE CODES:
BUILDING CODE..............UFC 1-200-01 / 2018 INTERNATIONAL BUILDING CODE
STRUCTURAL CODE...........UFC 3-301-01
PLUMBING CODE............UFC 3-420-01
MECHANICAL CODE.........UFC 3-401-01
FIRE CODE..................UFC 3-600-01 / NFPA 101
ELECTRICAL CODE...........UFC 3-501-01
ENERGY CODE..............UFC 1-200-02
ACCESSIBILITY CODE......2010 ADA STANDARDS
LIFE SAFETY CODE........UFC 3-600-01
IBC CHAPTER 3 AND UFC 3-600-01 OCCUPANCY & USE:
NFPA 101 CHAPTER 6:
• SEE LEGEND ON LIFE SAFETY PLAN
IBC CHAPTER 4 - SPECIAL DETAILED REQUIREMENTS:
• NOT APPLICABLE
IBC CHAPTER 5 - GENERAL BUILDING HEIGHTS & AREAS:
• CONSTRUCTION TYPE = II-B, SPRINKLED, GROUP B + A-3, SEPARATED
• ALLOWABLE BUILDING HEIGHT (PER TABLE 504.3)
75 FEET ABOVE GRADE PLANE
• ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (PER TABLE 504.4)
3 STORIES ABOVE GRADE PLANE FOR A-3 (MOST STRINGENT)
• TABULAR BUILDING AREA (PER TABLE 506.2)
A-3 - 38,000 SQUARE FEET
B - 92,000 SQUARE FEET
• FRONTAGE INCREASE FORMULA PER 506.3
I=(F/P -0.25)W/30 =0.75
• ALLOWABLE BUILDING AREA (PER SECTION 506.2)
GROUP B - 92,000 + (23,000*.75)=109,250
GROUP A-3 - 38,000 + (28,500*.75)=59,375
• ACTUAL BUILDING AREA
26,079 SQUARE FEET TOTAL
FIRST FLOOR - 13,589 SQUARE FEET
726 SQUARE FEET OF GROUP A-3
12,863 SQARE FEET OF GROUP B
726/59,375 + 12,863/109,250 = .13
SECOND FLOOR - 12,490 SQUARE FEET
0 SQUARE FEET OF GROUP A-3
12,490 SQUARE FEET OF GROUP B
0/59,375 + 12,490/109,250 = .11
SUM OF THE RATIOS
.13 + .11 = .24
• FIRE SEPARATION REQUIREMENTS SEPARATED OCCUPANCIES
1. SEPARATION BETWEEN GROUP B AND A-3 - 1 HOUR
• INCIDENTAL USE AREAS (PER TABLE 509)
SEE OCCUPANCY TABLE.
IBC CHAPTER 6 TYPES OF CONSTRUCTION:
• CONSTRUCTION TYPE: II-B
• FIRE RATINGS (PER TABLE 601) AS FOLLOWS (EXCEPT WHERE NOTED OTHERWISE)
PRIMARY STRUCTURAL FRAME.............................. 0 HOUR
BEARING WALLS (INTERIOR & EXTERIOR)...................0 HOUR
NON-BEARING WALLS AND PARITIONS (INTERIOR)........0 HOUR
FLOOR CONSTRUCTION AND SECONDARY MEMBERS...0 HOUR
ROOF CONSTRUCTION AND SECONDARY MEMBERS....0 HOUR
• REQUIRED FIRE RATING (PER TABLE 602)
OCCUPANCY FIRE SEPARATION REQ.
TYPE (ACTUAL) SEPARATION
B GREATER THAN 15'-0" 0 HR
A-3 GREATER THAN 15'-0" 0 HR
IBC CHAPTER 7 - FIRE AND SMOKE PROTECTION FEATURES:
• MAXIMUM EXTERIOR WALL OPENINGS (PER IBC SECTION 705)
FIRE SEPARATION: DEGREE OF OPENING PROTECTION: ALLOWABLE AREA: ACTUAL AREA:
NORTH ELEVATION UNPROTECTED, SPRINKLERED , (UP, S) NO LIMIT 20%
SOUTH ELEVATION UNPROTECTED, SPRINKLERED , (UP, S) NO LIMIT 17%
EAST ELEVATION UNPROTECTED, SPRINKLERED , (UP, S) NO LIMIT 11%
WEST ELEVATION UNPROTECTED, SPRINKLERED , (UP, S) 75% 20%
• FIRE WALLS (PER NFPA 8.3.2)
NO FIRE WALLS ARE PRESENT WITHIN THE SCOPE OF THE PROJECT
• SHAFT ENCLOSURE (PER NFPA 8.3.1 / 7.3.1.2)
EXISTING SHAFTS ARE PRESENT WITHIN THE SCOPE OF THE PROJECT BUT IS NOT AFFECTED BY THE SCOPE OF
THE WORK
• OPENING PROTECTIVES (PER NFPA 8.3.4)
TYPE OF ASSEMBLY ASSEMBLY RATING REQUIRED OPENING
PROTECTION (DOOR/SIDELITE)
NOT APPLICABLE
• CONCEALED SPACES (PER SECTION 718)
NOT APPLICABLE
• SEE LEGEND ON LIFE SAFETY PLAN FOR APPLICABLE UL ASSEMBLIES TO BE PROVIDED.
FIRST FLOOR PLAN CODE CALCULATIONS
Name
Occupancy Calculations Egress Width Calculations
Area (SF) Factor Type
Total Occupant
Load (Occupants)
Other Egress Component
Width
Calculated Width (Other
Egress Components)
(Inches)
Required Egress Width
(Inches)
ASSEMBLY A-3 726 SF NET 50.00 0.2 10.00 44
BUSINESS (COLLABORATION) 358 SF GROSS 12.00 0.2 2.40 44
BUSINESS (COLLABORATIVE) 454 SF GROSS 16.00 0.2 3.20 44
BUSINESS (COLLABORATIVE) 1218 SF 41.00 0.2 8.20
BUSINESS (CONCENTRATED) 959 SF GROSS 20.00 0.2 4.00 44
BUSINESS (CONCENTRATED) 3506 SF GROSS 71.00 0.2 14.20 44
BUSINESS (IT) 884 SF GROSS 3.00 0.2 0.60 44
BUSINESS (LOCKER) 1592 SF GROSS 32.00 0.2 6.40 44
BUSINESS (MECHANICAL) 142 SF GROSS 1.00 0.2 0.20 44
BUSINESS (STORAGE) 218 SF GROSS 1.00 0.2 0.20 44
BUSINESS (STORAGE) 672 SF GROSS 2.00 0.2 0.40 44
BUSINESS (STORAGE) 104 SF GROSS 1.00 0.2 0.20 44
BUSINESS (UNCONCENTRATED) 2437 SF GROSS 17.00 0.2 3.40 44
BUSINESS (UNCONCENTRATED) 313 SF GROSS 3.00 0.2 0.60 44
13584 SF 270.00 54.00
PLUMBING FIXTURE CALCULATIONS
Name Male
Occupancy Female
Occupancy
MALE
WATER
CLOSETS
FEMALE
WATER
CLOSETS MALE LAV
FEMALE
LAV
DRINKING
FOUNTAINS
ASSEMBLY 40 10 0.32 0.15 0.2 0.05 0.1
BUSINESS 303 76 7.06 2.52 4.79 1.9 3.79
343 86 7.38 2.67 4.99 1.95 3.89
IBC CHAPTER 8, UFC 3-600-01, NFPA 101 - INTERIOR FINISHES:
• FINISH MATERIAL RATING REQUIREMENTS (PER NFPA 101)
BUSINESS (CHAPTER 38)
WALLS
EXITS AND EXIT ACCESS CORRIDORS
INTERIOR WALL AND CEILING FINISH - CLASS A OR B (38.3.3.2.1)
ALL OTHER AREAS
INTERIOR WALL AND CEILING FINISH - CLASS A, B, OR C (38.3.3.2.2)
FLOORS
EXITS AND EXIT ACCESS CORRIDORS
INTERIOR FLOOR FINISH IN EXIT ENCLOSURES- CLASS I OR II (38.3.3.3.2)
ASSEMBLY (CHAPTER 12)
CORRIDORS AND LOBBIES
INTERIOR WALL AND CEILING FINISH - CLASS A OR B (12.3.3.2)
ENCLOSED STAIRWAYS
INTERIOR WALL AND CEILING FINISH - CLASS A (12.3.3.2)
ASSEMBLY AREAS
INTERIOR WALL AND CEILING FINISH SERVING MORE THAN 300 OCCUPANTS-
CLASS A OR B (12.3.3.3)
INTERIOR WALL AND CEILING FINISH SERVING LESS THAN 300 OCCUPANTS-
CLASS A, B, OR C (12.3.3.3)
SCREENS
PROJECTION SCREENS - CLASS A OR B (12.3.3.4)
EXITS AND EXIT ACCESS CORRIDORS
INTERIOR FLOOR FINISH - NOT LESS THAN CLASS II (12.3.3.5.2)
UFC 3-600-01(REPLACES IBC CHAPTER 9) - FIRE PROTECTION SYSTEMS:
• SECTION 9-1 - EMERGENCY VEHICLE ACCESS
1. FACILITY REQUIRES ALL-WEATHER EMERGENCY VEHICLE GROUND ACCESS IN
ACCORDANCE WITH 9-1.1. ALL-WEATHER EMERGENCY VEHICLE GROUND ACCESS IS
PROVIDED.
2. FACILITY DOES NOT REQUIRE AERIAL APPARATUS ACCESS IN ACCORDANCE WITH
9-1.2
• SECTION 9-2 - FIRE FLOW FOR FACILITIES
1. FIRE FLOW FOR SPRINKLER SYSTEM IS PROVIDED IN ACCORDANCE WITH 9-2.1
• SECTION 9-3 - SERVICE MAINS AND LATERALS
1. FIRE HYDRANTS ARE PROVIDED IN ACCORDANCE WITH 9-3.5.8.2
A. ALL PARTS OF THE FACILITY EXTERIOR ARE WITHIN 350 FT OF A HYDRANT
2. FIRE HYDRANTS ARE PROVIDED IN ACCORDANCE WITH 9-3.5.8.4
A. ONE HYDRANT IS LOCATED WITH 150FT OF THE FIRE DEPARTMENT CONNECTION
• SECTION 9-5 - FIRE PUMPS
1. A FIRE PUMP IS NOT REQUIRED TO MEET FIRE PROTECTION DEMAND
• SECTION 9-7 - AUTOMATIC SPRINKLER SYSTEMS
1. PER 9-7.2.1, AN AUTOMATIC SPRINKLER SYSTEM IS REQUIRED AND PROVIDED
• SECTION 9-10 - STANDPIPE SYSTEMS
1. PER 9-10, A STANDPIPE SYSTEM IS NOT REQUIRED
• SECTION 9-17 - PORTABLE FIRE EXTINGUISHERS
1. FIRE EXTINGUISHERS ARE PROVIDED, SEE PLANS FOR LOCATIONS
NFPA CHAPTER 7 (REPLACES IBC CHAPTER 10) - MEANS OF EGRESS:
• OCCUPANCY LOAD (PER TABLE 7.3.1.2):
SEE OCCUPANCY TABLE
• EGRESS CAPACITY SIZING (PER TABLE 7.3.3.1)
SEE CODE CALCULATIONS TABLE(S)
SEE LIFE SAFETY PLAN FOR INDIVIDUAL ROOM EGRESS ANALYSIS
• MINIMUM STAIR WIDTH (PER SECTION 7.3.3.1)
SEE CODE CALCULATIONS TABLE(S)
SECOND FLOOR PLAN CODE CALCULATIONS
Name
Occupancy Calculations Egress Width Calculations
Area (SF) Factor Type
Total Occupant
Load (Occupants)
Other Egress Component
Width
Calculated Width (Other
Egress Components)
(Inches)
Required Egress Width
(Inches)
BUSINESS (STORAGE) 215 SF 1.00 0.2 0.20
BUSINESS (COLLABORATION) 595 SF GROSS 20.00 0.2 4.00 44
BUSINESS (COLLABORATION) 1215 SF GROSS 41.00 0.2 8.20 44
BUSINESS (CONCENTRATED) 569 SF GROSS 12.00 0.2 2.40 44
BUSINESS (EXERCISE) 1581 SF 32.00 0.2 6.40
BUSINESS (IT) 153 SF GROSS 1.00 0.2 0.20 44
BUSINESS (LOCKERS) 360 SF GROSS 8.00 0.2 1.60 44
BUSINESS (MECHANICAL) 496 SF GROSS 1.00 0.2 0.20 44
BUSINESS (STORAGE) 78 SF GROSS 1.00 0.2 0.20 44
BUSINESS (UNCONCENTRATED) 6680 SF GROSS 45.00 0.2 9.00 44
11941 SF 162.00 32.40
• NUMBER OF MEANS OF EGRESS (PER SECTION 7.4.1)
TOTAL NUMBER OF EXITS REQUIRED
BUSINESS OCCUPANCY (CHAPTER 38)
GROUND FLOOR - 2 EXITS REQUIRED
GROUND FLOOR - 2 EXITS REQUIRED
ASSEMBLY OCCUPANCY (CHAPTER 12)
GROUND FLOOR - 2 EXITS REQUIRED
SECOND FLOOR - 2 EXITS REQUIRED
• COMMON PATH OF EGRESS TRAVEL DISTANCE
BUSINESS OCCUPANCY (CHAPTER 38)
100 FT (WHEN SERVING LESS THAN 50 OCCUPANTS) PER 38.2.5.1
ASSEMBLY OCCUPANCY (CHAPTER 12)
75 FT (WHEN SERVING LESS THAN 50 OCCUPANTS) PER 12.2.5.1.2
20 FT (WHEN SERVING MORE THAN 50 OCCUPANTS) PER 12.2.5.1.2
• EXIT ACCESS TRAVEL DISTANCE
BUSINESS OCCUPANCY (CHAPTER 38)
300 FEET PER 12.2.6.3
ASSEMBLY OCCUPANCY (CHAPTER 12)
250 FEET PER 12.2.6.2
• CORRIDORS
OCCUPANCY TYPE (B) REQUIRES:
NO FIRE RATING REQUIRED FOR CORRIDOR WALLS
OCCUPANCY TYPE (A) REQUIRES:
NO FIRE RATING REQUIRED FOR CORRIDOR WALLS
SEE LIFE SAFTEY PLAN FOR LOCATIONS OF RATED WALLS
MINIMUM CORRIDOR WIDTH
ASSEMBLY OCCUPANCY (CHAPTER 12)
44 INCHES PER 12.2.3.8
BUSINESS OCCUPANCY (CHAPTER 38)
44 INCHES PER 38.2.3.2
DEAD END CORRIDORS
BUSINESS OCCUPANCY (CHAPTER 38)
MAXIMUM OF 50 FEET PER 38.2.5.2.1
ASSEMBLY OCCUPANCY (CHAPTER 12)
MAXIMUM OF 20 FEET PER 12.2.5.1.3
TRAVEL DISTANCE = 87 FEET
TRAVEL DISTANCE = 100 FT
6680 SF
BUSINESS
(UNCONCENTRATED)
78 SF
BUSINESS (STORAGE)
153 SF
BUSINESS (IT)
496 SF
BUSINESS
(MECHANICAL)
595 SF
BUSINESS
(COLLABORATION)
360 SF
BUSINESS (LOCKERS)
6.8 5.1
1.2
23.2 17.4 116 116
14.6 10.95
2 OCCUPANTS
1 OCCUPANT1 OCCUPANT1 OCCUPANT2 OCCUPANTS
12 OCCUPANTS
2 OCCUPANTS
3 OCCUPANTS
1 OCCUPANT
3 OCCUPANTS
1 OCCUPANT
1 OCCUPANT
1 OCCUPANT
1 OCCUPANT
2 OCCUPANTS 2 OCCUPANTS
3 OCCUPANTS
20 OCCUPANTS
3 OCCUPANTS
32 OCCUPANTS8 OCCUPANTS
3 OCCUPANTS
41 OCCUPANTS
1 OCCUPANT
2 OCCUPANTS
2 OCCUPANTS
1215 SF
BUSINESS
(COLLABORATION)
569 SF
BUSINESS
(CONCENTRATED)
1581 SF
BUSINESS (EXERCISE)
215 SF
BUSINESS
(STORAGE)
TRAVEL DISTANCE
= 115 FEET
726 SF
ASSEMBLY A-3
2437 SF
BUSINESS
(UNCONCENTRATED)
884 SF
BUSINESS (IT)
142 SF
BUSINESS
(MECHANICAL)
218 SF
BUSINESS (STORAGE)
672 SF
BUSINESS (STORAGE)
104 SF
BUSINESS (STORAGE)
959 SF
BUSINESS
(CONCENTRATED)
313 SF
BUSINESS
(UNCONCENTRATED)
3506 SF
BUSINESS
(CONCENTRATED)
25.95 173 173
8.55
10.5
5.4
10.05
26 OCCUPANTS
50 OCCUPANTS
1 OCCUPANT
2 OCCUPANT
3 OCCUPANTS
1 OCCUPANT
1 OCCUPANT
1 OCCUPANT
3 OCCUPANTS
1 OCCUPANT
1 OCCUPANT
1 OCCUPANT
13 OCCUPANTS
8 OCCUPANTS 7 OCCUPANTS 7 OCCUPANTS 7 OCCUPANTS 7 OCCUPANTS 1 OCCUPANT
2 OCCUPANTS
17 OCCUPANTS
12 OCCUPANTS
1 OCCUPANT
2 OCCUPANTS
1 OCCUPANT
16 OCCUPANTS
11 OCCUPANTS
2 OCCUPANTS
9.
21 OCCUPANTS
358 SF
BUSINESS
(COLLABORATION)
1592 SF
BUSINESS (LOCKER)
454 SF
BUSINESS
(COLLABORATIVE)
1218 SF
BUSINESS
(COLLABORATIVE)
3 OCCUPANTS
3 OCCUPANTS
1 OCCUPANT
2.
551717
3.
752525
HANDICAP ACCESSIBLE EXIT LOCATION
EXIT TRAVEL PATH
ELECTRIC WATER COOLER - SEE PLUMBINGEWC
EMERGENCY EXIT SIGNAGE
LIFE SAFETY LEGEND
FIRE EXTINGUISHER ON BRACKET
(TYPE 4A:80B:C)
FEB
ROOM TAG
ROOM NAME
150 SF
BUSINESS B OCCUPANCY GROUP (IBC 2018)
50 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
BUSINESS B OCCUPANCY GROUP (IBC 2018)
300 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
BUSINESS B OCCUPANCY GROUP (IBC 2018)
500 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
OCCUPANT LOAD
REQUIRED DOOR WIDTH
REQUIRED STAIR WIDTH
UL ASSEMBLY TAG
BUSINESS B OCCUPANCY GROUP (IBC 2018)
500 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
1 SMOKE PARTITION / FIRE RATED WALL
CONSTRUCTION TO EXTEND FROM TRUE
FLOOR TO UNDERSIDE OF TRUE ROOF
ABOVE. SEE PLAN FOR LOCATION OF
SMOKE PARTITION VERSUS FIRE RATED WALL
CONSTRUCTION.
BUSINESS B OCCUPANCY GROUP (IBC 2018)
30 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
BUSINESS B OCCUPANCY GROUP (IBC 2018)
50 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
BUSINESS B OCCUPANCY GROUP (IBC 2018)
150 SF PER OCCUPANT PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
ASSEMBLY A-3 OCCUPANCY GROUP (IBC 2018)
50 FIXED SEATS PER NFPA 101
ORIDINARY HAZARD (NFPA 101)
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
LS1.1
LIFE SAFETY
PLANS
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
1" = 10'-0"LS1.1
1 LEVEL 2 FFE
1" = 10'-0"LS1.1
2 LEVEL 1 FFE
S15
S16
602 SF
ALIS SERVER ROOM
S16
1287 SF
INTEL WORK AREA B
S26
179 SF
STORAGE
S27
187 SF
VESTIBULE
575 SF
MOBILE STORAGE
637 SF
INTEL WORK AREA A
S05
32 SF
ESD
77 SF
RUBBER ROOM
128 SF
AIRCREW TRAINING
412 SF
LIFE SAFETY
313 SF
SECURE OFFICE
S24
106 SF
OFFICE
S25
227 SF
BRIEFING
S02
191 SF
BRIEFING
S04
197 SF
BRIEFING
S11
198 SF
BRIEFING
S12
195 SF
ALIS ADMIN
S13
341 SF
MASS BRIEFING
S10
525 SF
WING PROGRAM
S14
196 SF
SECURE COMM
S17
S13
120 SF
ELECTRICAL
1036 SF
WEAPONS & TACTICS
S23
NOTE: WALL PENETRATIONS OF ANY
KIND WILL NOT BE PERMITTED WITHIN
THIS REGION
714 SF
PERFORMANCE
ELEMENT
335 SF
MECHANICAL
202 SF
STORAGE
772 SF
PERFORMANCE
ELEMENT
528 SF
WAR ROOM
239 SF
AFM
390 SF
FLIGHT SCHEDULING &
TRAINING
186 SF
CSS
186 SF
ADO
512 SF
OPERATIONS DESK
181 SF
OFFICE
144 SF
OFFICE
144 SF
OFFICE
144 SF
OFFICE
250 SF
OFFICE
108 SF
ELECTRICAL
394 SF
ARMS
PHASE IA - ALIS SERVER, ALIS ADMIN, AND SECURE COMM ROOM UPGRADES
REFER TO SPECIFICATION SECTION 00 0102 - PROJECT INFORMATION AND SUMMARY
FOR ADDITIONAL INFORMATION AND PHASING REQUIREMENTS.
PHASE IB - COMMUNICATIONS UPGRADES
REFER TO SPECIFICATION SECTION 00 0102 - PROJECT INFORMATION AND SUMMARY FOR ADDITIONAL
INFORMATION AND PHASING REQUIREMENTS.
HATCHED AREA INDICATES EXISTING BUILDING THAT IS EXPECTED TO BE OUTSIDE THE
SOPE OF WORK, HOWEVER NEW AND EXISTING POWER AND COMMUNICATIONS CABLING,
RACEWAYS, CONDUIT, ETC. SCHEDULED FOR REWORK MAY EXIST WITHIN AND ABOVE
THESE AREAS. GENERAL CONTRACTOR TO VISIT THE SITE TO BECOME COMPLETELY
FAMILIAR WITH EXISTING CONDITIONS. GENERAL CONTRACTOR TO TAKE EXTREME
CAUTION TO PROTECT EXISTING FINISHES WHERE NEW WORK INTERFACES WITH EXISTING
BUILDING. IF WORK IS REQUIRED IN THIS AREA, GENERAL CONTRACTOR TO REPAIR ANY
DAMAGE TO EXISTING FINISHES THAT OCCURS DUE TO CONSTRUCTION / DEMOLITION
ACTIVITIES.
PHASING LEGEND
PHASE II - NEW CONSTRUCTION
REFER TO SPECIFICATION SECTION 00 0102 - PROJECT INFORMATION AND SUMMARY FOR
ADDITIONAL INFORMATION AND PHASING REQUIREMENTS.
REFER TO SPECIFICATION SECTION 00 0102 FOR DETAILED PHASING DESCRIPTIONS.
SAPF INTRUSION DETECTION AND PHYSICAL SECURITY MUST BE COMPLETELY INSPECTED
AND ACCREDITED PRIOR TO ANY PENETRATIONS ARE PREFORMED IN EXISTING NORTH.
• PENETRATION FOR INTRUSION DETECTION IS THE ONLY EXCEPTION.
• PENETRATION AND CONNECTION TO NEW INTRUSION DETECTION PANEL MUST
BE COMPLETE IN ONE DAY.
1. ALL DEVICES IN EXISITNG INTEL AREA TO BE RE-ROUTED TO NEW
INTRUSION DETECTION SYSTEM PANEL AND NEW INTRUSION
DETECTION SYSTEM MUST BE OPERATIONAL AT THE END OF EACH
DAY.
PHASING NOTES
PHASE IV - INTEL SECURITY UPGRADES:
REFER TO SPECIFICATION SECTION 00 0102 - PROJECT INFORMATION AND SUMMARY FOR
ADDITIONAL INFORMATION AND PHASING REQUIREMENTS.
PHASE III - INTERIOR POWER MODIFICATIONS
REFER TO SPECIFICATION SECTION 00 0102 - PROJECT INFORMATION AND SUMMARY FOR
ADDITIONAL INFORMATION AND PHASING REQUIREMENTS.
PHASE V - INTERIOR RENOVATIONS OF EXISTING AREAS
REFER TO SPECIFICATION SECTION 00 0102 - PROJECT INFORMATION AND SUMMARY FOR
ADDITIONAL INFORMATION AND PHASING REQUIREMENTS.
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A0.1
PHASING PLAN
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
3/32" = 1'-0"A0.1
1 LEVEL 1 PHASING PLAN
3/32" = 1'-0"A0.1
2 LEVEL 2 PHASING PLAN
Project Title
Job Number
Date
Drawn By
Checked By
S o u th
C o u rt
S tr ee t
M o n tg o m er y, A
L
T el
. 3 . 5
W W
W .S
S L
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
A1.0
DEMOLITION
NOTES
F -3
A
D A
L S
Q U
A D
R O
N O
P E
R A
T
IO
N S B
U
IL
D
IN
G
D A
N N
E L
L Y
F
IE
L D
M O
N T
G O
M E
R Y
A
L A
B A
M A
10065.02
JUNE 2022
ME, DCD
DCD
General Demolition Notes:
THE INTENT OF DEMOLITION IS TO ACCOMPLISH ALL WORK NECESSARY TO PROVIDE A FINISHED, COMPLETE
BUILDING AS INDICATED IN THE PLANS AND SPECIFICATIONS. THE FOLLOWING GENERAL NOTES ARE APPLICABLE
TO ALL DEMOLITION ACTIVITIES REQUIRED BY THE SCOPE OF THE CONTRACT DOCUMENTS.
CONTRACTOR'S RESPONSIBILTY TO VERIFY ACCURACY OF EXISTING CONDITIONS:
1. DOCUMENTATION CONTAINED IN THESE CONSTRUCTION DOCUMENTS OF EXISTING CONDITIONS MAY
NOT BE ENTIRELY ACCURATE. CONTRACTOR IS TO TAKE THE INITIATIVE TO VISIT THE SITE PRIOR TO AND
DURING THE PRE-BID MEETING TO VERIFY ACTUAL CONDITIONS, THEREFORE RENDERING THE
CONTRACTOR RESPONSIBLE FOR AN ACCURATE REPRESENTATION OF THE EXISTING CONDITIONS.
2. CONTRACTOR TO VISIT SITE TO VERIFY EXISTING CONDITIONS AND SHALL BE RESPONSIBLE FOR
DETERMINING THE SCOPE OF WORK PRIOR TO DEMOLITION . EXISTING CONDITIONS SHALL BE
THOROUGHLY RESEARCHED PRIOR TO CONSTRUCTION AND ANY DRAWINGS SHALL BE IMMEDIATELY
DISCUSSED WITH ARCHITECT PRIOR TO BEGINNING CONSTRUCTION IN THE AFFECTED AREA. CHANGE
ORDERS WILL NOT BE APPROVED PRIOR TO WORK TAKING PLACE FOR EXISTING CONDITIONS READILY
APPARENT BY A THOROUGH OBSERVATION.
3. CONTRACTOR TO VERIFY ALL EXISTING FLOOR ELEVATIONS AND VERIFY WITH PLANS. REPORT ANY
DISCREPANCIES WITH ARCHITECT PRIOR TO CONSTRUCTION
4. CONTRACTOR SHALL VERIFY IF THERE ARE EXISTING TILE SETTING BEDS. IN SUCH CASE, CONTRACTOR IS
RESPONSIBLE FOR DEMOING EXISTING SETTING BED(S) AND FILL EXISTING DEPRESSED CONCRETE SLAB
AREAS WITH MATERIALS CONSISTENT WITH ADJACENT MATERIALS AND FINISHES REQUIRED TO MEET ALL
APPLICABLE CODES.
5. DIMENSIONS OF EXISTING STRUCTURES ARE ONLY FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. LOCATION OF WALLS SHALL BE AS SHOWN ON
PLANS RELATIVE TO EXISTING CONDITIONS.
6. THE OWNER ASSUMES NO RESPONSIBILITY FOR EXISTING UNKNOWN CONDITIONS. EACH CONTRACTOR
SHALL COORDINATE NEW CONSTRUCTION WITH EXISTING CONSTRUCTION AND INVESTIGATE IN A
REASONABLE MANNER REGARDING HIDDEN CONDITIONS.
SAFEGUARDS DURING DEMOLITION:
1. CONTRACTOR TO MAKE SURE ALL INFRASTRUCTURE (POWER, GAS, WATER, CABLING, ETC...) IS TURNED
OFF AND/OR REMOVED PRIOR TO DEMOLITION.
2. CONTRACTOR TO VERIFY ALL LOAD BEARING CONDITIONS AND PROVIDE SHORING AS REQUIRED IN ALL
AFFECTED AREAS PRIOR TO & DURING DEMOLITION AND/OR CONSTRUCTION.
3. ALL CURRENT OSHA AND APPLICABLE STANDARDS SHALL BE UPHELD TO ASSURE SAFETY OF ALL
PERSONS ON SITE DURING ENTIRE COURSE OF CONSTRUCTION.
CONTRACTOR'S RESPONSIBILTY TO REMOVE ALL ENCUMBRANCES REQUIRED FOR PROPER INSTALLATION OF
NEW SYSTEMS:
1. REMOVAL OF ALL ENCUMBRANCES INCLUDING BUT NOT LIMITED TO DUCTS, PIPING, WIRING, ETC… SHALL
BE DONE BY THE CONTRACTOR TO ACHIEVE PLANS AS SHOWN EVEN IF NOT SHOWN ON DEMOLITION
PLANS.
2. REMOVAL OF ALL ENCUMBRANCES INCLUDING BUT NOT LIMITED TO CONCRETE, WOOD, DUCTS, PIPING, WIRING, SHALL BE DONE BY THE CONTRACTOR TO ACHIEVE FLOOR PLANS AS SHOWN EVEN IF NOT
SHOWN ON DEMOLITION PLANS.
3. REMOVE ALL CEILINGS AND ITEMS ABOVE CEILINGS THAT ARE NOT REQUIRED IN THE RENOVATED
BUILDING AND AS REQUIRED TO INSTALL NEW HVAC, PLUMBING, LIGHTING, ELECTRICAL, ETC. FOR FULLY
FUNCTIONING SYSTEMS.
4. REMOVE ANY UNUSED PENETRATIONS AND INSTALL NEW DECKING/ROOFING OVER ANY OPENINGS
5. UNLESS NOTED OTHERWISE, CONTRACTOR SHALL REMOVE GYPSUM WALLBOARD AND ANY FURRING
STRIPS AND/OR FASTENERS FROM EXTERIOR WALLS TO PREPARE FOR NEW FINISH.
6. REMOVE ALL ABANDONED FIXTURES, PIPING, CONDUIT WIRING, INSULATION, EQUIPMENT, STRUCTURAL
SUPPORTS, ARCHITECTURAL SYSTEMS., ETC… NO LONGER IN USE OR UNNECESSARY FOR THE
RENOVATED PROJECT. PROVIDE PATCHING WITH MATERIALS CONSISTENT WITH ADJACENT MATERIALS
AND FINISHES REQUIRED, UNLESS OTHERWISE NOTED, TO MEET ALL APPLICABLE CODES.
7. REMOVE ALL MISCELLANEOUS HARDWARE, PANELING, CLIPS, FASTENERS, WIRE, CONDUIT, PIPES, ETC…
FROM ANY AND ALL SURFACES TO RECEIVE A NEW FINISH. PATCH SUBSTRATES BY FILLING, GRINDING
AND SANDING SMOOTH WITH ACCEPTABLE CONSTRUCTION INDUSTRY AND CODE COMPLIANT
MATERIALS. PREPARE SURFACE FOR ACCEPTANCE OF MANUFACTURER SPECIFIED FINISH AND SURFACE
TREATMENT. INSTALLATION OF FINISH INDICATES ACCEPTANCE OF SUBSTRATE BY APPLICATOR. WHERE
NO NEW FINISHES OCCUR, PATCH EXISTING MATERIALS WITH MATCHING MATERIALS SO THAT PATCH
WORK IS NOT VISIBLE.
8. REMOVE ALL EXISTING ACOUSTICAL TILE, CEILING GRID, HANGERS, AND ASSOCIATED FRAMING UP TO
UNDERSIDE OF ROOF.
9. REMOVE EXISTING FLOORING AS REQUIRED TO INSTALL NEW FLOORING. PROVIDE MANUFACTURE’S
REQUIRED LEVELING MATERIALS PRIOR TO INSTALLING NEW FLOORS. REFER TO SPECIFICATIONS OF
FLOORING FOR ADDITIONAL REQUIREMENTS. FIELD TEST EXISTING FLOORING SUBSTRATE AS REQUIRED
BY PROJECT SPECIFICATIONS AND/OR FLOORING MANUFACTURER TO ENSURE MOISTURE CONTENT, RELATIVE HUMIDITY, FLOOR FLATNESS, AND OTHER SUBSTRATE CONDITIONS ARE WITHIN ACCEPTABLE
RANGES FOR INSTALLATION OF NEW SCHEDULED FLOOR MATERIALS INTENDED TO BE INSTALLED.
PROVIDE MANUFACTURER'S WRITTEN ACCEPTANCE OF SUBSTRATE CONDITIONS PRIOR TO PROCEEDING
WITH INSTALLATION OF NEW FLOOR SYSTEMS. INSTALLATION OF NEW FLOORING SYSTEMS INDICATED
ACCEPTANCE OF THE SUBSTRATE BY THE CONTRACTOR AND INSTALLER.
10. THE CONTRACTOR IS ALSO RESPONSIBLE FOR THE REMOVAL OF DEMOLISHED MATERIALS: FOR THE
PATCHING OF EXISTING SURFACES, INCLUDING OPENINGS IN FLOORS, WALLS, ETC. TO MATCH
UNDISTURBED EXISTING SURFACES, AND FOR LEAVING THE AREA IN A CLEAN CONDITION. REFER TO
CONTRACT DOCUMENTS FOR SPECIFIC FLOOR RELATED DETAILS.
General Demolition Notes (Continued):
CONTRACTOR'S RESPONSIBILTY TO RETURN THE SITE/STRUCTURE TO PRE-WORK CONDITIONS
1. CONTRACTOR TO TAKE EXTREME CARE AT EXISTING EXTERIOR FINISHES, INCLUDING BUT NOT LIMITED TO
BRICK, METALWORK, WINDOWS, AND DOORS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY
EXTERIOR FINISHES THAT WERE COMPROMISED DURING THE COURSE OF CONSTRUCTION.
2. CONTRACTOR TO PROTECT ALL FINISHES TO REMAIN ON INTERIOR OF EXISTING SPACES INCLUDING
WALLS, CEILINGS, FLOORS, DOORS, FIXTURES, ETC.
CONTRACTOR'S RESPONSIBILITY REGARDING REMOVAL AND DISPONSAL OF DEMOLISHED MATERIALS:
1. EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LAWS, REGULATIONS, AND/OR ORDINANCES REGARDING THE METHOD OF DEMOLITION AND DISPOSAL OF WASTE MATERIALS.
THE OWNER ASSUMES NO LIABILITY FOR EXTRA WORK OR ADDITIONAL COMPENSATION DUE TO FAILURE
OF THE TRADE CONTRACTOR OR SUBCONTRACTORS TO COMPLY WITH ANY AND ALL SUCH REGULATIONS
THAT APPLY.
CONTRACTOR'S RESPONSIBILTY REGARDING HAZARDOUS MATERIALS:
1. CONTRACTOR SHALL COMPLY WITH ALL SPECIFIED REQUIREMENTS AND GOVERNING
CODES/LAWS/REGULATIONS REGARDING REMOVAL AND DISPOSAL OF HAZARDOUS MATERIALS, IF
ENCOUNTERED.
2. IF HAZARDOUS MATERIALS ARE ENCOUNTERED, NOTIFY ARCHITECT PRIOR TO PROCEEDING.
ADDITIONAL MISCELLANEOUS PROVISIONS
1. GENERAL DEMOLITION NOTES APPLY TO THE ENTIRE PROJECT. SPECIFIC NOTES (DESIGNATED) APPLY TO
ISOLATED WORK AREAS AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR. HOWEVER, ALL
ISOLATED WORK AREAS ARE NOT NOTED. SHOULD A CONDITION OCCUR THAT IS NOT SPECIFICALLY
NOTED, THE CONTRACTOR SHALL PROCEED WITH WORK PER GENERAL DEMOLITION NOTES OR A SPECIFIC
WORK NOTE(S) USED IN OTHER SIMILAR CONDITIONS, WHICHEVER IS MORE STRINGENT, PER APPROVAL
OF ARCHITECT VIA OWNER.
2. REFER ALSO TO SELECTED DEMOLITION, SUMMARY OF WORK, ADDITIONAL INSTRUCTIONS TO BIDDERS
AND OTHER SPECIFICATION SECTIONS REQUIRED.
3. REFER TO OTHER DISCIPLINES TO INCLUDE BUT NOT LIMITED TO LANDSCAPE, CIVIL, PLUMBING, MECHANICAL, AND STRUCTURAL FOR ADDITIONAL DEMOLITION AND REPARATION REQUIREMENTS. PATCH
ALL LOCATIONS REQUIRED BY PLUMBING, MECHANICAL, AND ELECTRICAL DEMOLITION. MATCH
ADJACENT CONDITIONS, UNLESS OTHERWISE NOTED. ALL REQUIRED TRENCHING AND REPLACEMENT OF
EXISTING SLABS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
4. CONTRACTOR TO REPAINT ALL EXTERIOR HOLLOW METAL FRAMES. BOTH INTERIOR AND EXTERIOR OF
FRAME TO BE PAINTED.
5. DURING ROOFING DEMOLITION PROVIDE TEMPORARY ROOFING AS REQUIRED TO PROTECT BUILDING
FROM DAMAGE.
6. CONTRACTOR TO ASSUME ALL CONCRETE INDICATED TO BE REMOVED IS REINFORCED.
7. IN LOCATION WHERE THE PLANS CALL FOR THE DEMOLITION OF THE EXISTING EXTERIOR BRICK VENEER, THE CONTRACTOR SHALL DISMANTLE THE BRICK VENEER AND REMOVE ALL MORTAR FOR USE IN OTHER
LOCATIONS FOR PATCHING. CONTRACTOR SHALL COORDINATE, WITH ARCHITECT, LOCATIONS WHERE
RECYCLED BRICK ARE TO BE USED FOR PATCHING.
8. AT LOCATIONS IN EXISTING FIRE WALLS WHERE SERVICES ARE REMOVED OR OPENINGS ARE CREATED, PATCH WALLS TO MAINTAIN REQUIRED FIRE RATING.
9. REMOVE AND REPLACE ALL EXISTING VERTICAL AND HORIZONTAL EXTERIOR BRICK VENEER CONTROL
JOINTS. SUBMIT ACTUAL SEALANT JOINT COLOR SAMPLES TO ARCHITECT FOR APPROVAL.
S01
S02
S03
S04
S05
S06
S07
S08
S09
S11
S10A S10B
S12 S13
S14
S21
S22
S20
S18
S17
S16
S15
S25
112A
113A
105A
FB
EWC
S19
412 SF
LIFE SAFETY
602 SF
ALIS SERVER ROOM
S16
525 SF
WING PROGRAM
S14
313 SF
SECURE OFFICE
S24
227 SF
BRIEFING
S02
191 SF
BRIEFING
S04
197 SF
BRIEFING
S11
198 SF
BRIEFING
S12 196 SF
SECURE COMM
S17
142 SF
IAO
S18
120 SF
ELECTRICAL
147 SF
WT OFFICE A
S20
118 SF
WT OFFICE B
S21
1036 SF
WEAPONS & TACTICS
S23
90 SF
STORAGE
S22
102 SF
INTEL WORKROOM
S06
44 SF
MANTRAP
S01
109 SF
INTEL OFFICE A
S09
110 SF
INTEL OFFICE B
S08
111 SF
INTEL OFFICE C
S07
1445 SF
LIFE SAFETY
77 SF
RUBBER ROOM
341 SF
MASS BRIEFING
S10
405 SF
CIRCULATION
S03
493 SF
CIRCULATION
233 SF
STAIRS
182 SF
MEN'S
109 SF
WOMEN'S
106 SF
OFFICE
S25
52 SF
ELEVATOR
195 SF
ALIS ADMIN
S13
637 SF
INTEL WORK AREA A
S05
128 SF
AIRCREW TRAINING
330 SF
COVERED STAIR
21 SF
STOR
32 SF
ESD
LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
DOTTED LINE GENERALLY INDICATES EXISTING AREAS TO BE
REMOVED, INCLUDING BUT NOT LIMITED TO WALLS,
DOORS, FLOOR COVERING, CEILINGS, ETC... IN CASE OF
UNCERTAINTY PROVIDE WRITTEN REQUEST TO ARCHITECT.
xx SPECIFIC NOTE TAG (SEE
DEMOLITION NOTES)
1 EXISTING WALL TO REMAIN. INSTALL NEW WALL ASSEMBLY AS
REQUIRED TO MEET ICD-705 REQUIREMENTS. SEE A2.5.
REMOVE EXISTING DOOR AND FRAME ASSEMBLY. PROVIDE NEW
SAPF PERIMETER DOOR ASSEMBLY IN THIS LOCAITON - REFER TO
NEW PLANS .
RELOCATE EXISTING COMPRESSED AIR AND VACUUM EQUIPMENT
INTO NEW NEW MOBILE STORAGE AREA. EXTEND PIPING AS
REQUIRED. VACUUM AND AIR OUTLETS WILL REMAIN IN RUBBER
ROOM , ROOM 111.
SAW CUT AND REMOVE EXISITNG FLOOR SLAB AS REQUIRED TO
INSTALL NEW FIRE WATER SERVICE ENTRANCE.
REMOVE AND REPLACE EXISITNG CEILING TILE AND/OR GRID AS
REQUIRED TO INSTALL NEW ABOVE CEILING COMPONENTS.
REMOVE EXISTING VENEER, INSULATION, FLASHING, VENEER TIES,
ETC. AS REQUIRED TO CONSTRUCT NEW ADDITION.
NO NEW PENETRATIONS PERMITTED IN THIS SECTION OF WALL -
COORDINATE WITH ALL TRADES.
REFER TO ELECTRICAL FOR COMMUNICATIONS DEMOLITION
REQUIRED IN THIS AREA.
DEMOLISH EXISITNG CEILING IN THIS SPACE EXISTING.
REMOVE EXISTING LIGHT FIXTURES AND HIGH DENSITY STORAGE
SYSTEMS. SALVAGE LIGHTS AND STORAGE FOR REINSTALLATION IN
ROOM 113.
ALL NEW PENETRATIONS REQUIRED FOR NEW ROOM S26 AND S27
TO BE MADE IN THIS PORTION OF EXISITNG WALL. COORDINATE
TIMING OF PENETRATIONS WITH SECURITY OFFICER AND PHASING
PLAN.
REFER TO MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION
DRAWINGS FOR REQUIRED DEMOLITION IN THIS PHASE.
SPECIFIC NOTES:
HATCHED REGION GENERALLY INDICATES PORTION
OF EXISTING BUILDING TO BE DEMOLISHED. REFER
TO SPECIFIC NOTES FOR ADDITIONAL
INFORMATION.
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A1.1
LEVEL 1
DEMOLITION
PLAN
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
1/8" = 1'-0"A1.1 1 LEVEL 1 FLOOR PLAN Copy 2
0' 4' 8' 16' 32'
202A
202B
208208A
228 227
225 224
223 221 220
214 215
SF4
SF3
REF
EWC
230 229
449 SF
TRAGUS
394 SF
ARMS
528 SF
WAR ROOM
335 SF
MECHANICAL
143 SF
NON-SECURE COM
108 SF
ELECTRICAL
324 SF
FLIGHT
COMMANDERS
213147 SF
STAN & EVAL
185 SF
OHWS
239 SF
AFM
390 SF
FLIGHT SCHEDULING &
TRAINING
186 SF
CSS
186 SF
ADO
512 SF
OPERATIONS DESK
181 SF
OFFICE
144 SF
OFFICE
144 SF
OFFICE
144 SF
OFFICE
250 SF
OFFICE
926 SF
DAY ROOM
161 SF
BREAKROOM
64 SF
VESTIBULE
199 SF
WOMEN'S RESTROOM
& LOCKERS
64 SF
JANITOR
52 SF
ELEVATOR
243 SF
STAIRS
346 SF
MEN'S RESTROOM
311 SF
MEN'S LOCKER
523 SF
CIRCULATION
421 SF
CIRCULATION
692 SF
CIRCULATION
174 SF
CIRCULATION
772 SF
PERFORMANCE
ELEMENT
362 SF
BALCONY
202A
1 4 3 3
202 SF
STORAGE
6 6 6 6
6 6 6 6
LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
DOTTED LINE GENERALLY INDICATES EXISTING AREAS TO BE
REMOVED, INCLUDING BUT NOT LIMITED TO WALLS,
DOORS, FLOOR COVERING, CEILINGS, ETC... IN CASE OF
UNCERTAINTY PROVIDE WRITTEN REQUEST TO ARCHITECT.
xx SPECIFIC NOTE TAG (SEE
DEMOLITION NOTES)
REMOVE EXISTING VENEER, INSULATION, FLASHING, VENEER TIES,
ETC. AS REQUIRED TO CONSTRUCT NEW ADDITION.
REMOVE EXISITNG WALL AS REQUIRED TO INSTALL NEW DOOR
ASSEMBLY.
EXISTING DOWNSPOUT TO REMAIN. MODIFY DOWNSPOUT AS
REQUIRED. TO DISCHARGE ONTO NEW LOW ROOF ASSEMBLY.
REMOVE EXISTING DOWNSPOUT BOOT AND CONNECTION TO
UNDERGROUND STORM DRAINAGE - SEE CIVIL. SALVAGE
DOWNSPOUT BOOT FOR REINSTALLATION.
EXISTING DOWNSPOUT TO BE DEMOLISHED. REMOVE DOWNSPOUT
BOOT AND CONNECTION TO UNDERGROUND STORM. FOR
DRAINAGE SEE CIVIL. SALVAGE DOWNSPOUT BOOT FOR
REINSTALLATION.
REMOVE AND REPLACE EXISITNG CEILING TILE AND/OR GRID AS
REQUIRED TO INSTALL NEW ABOVE CEILING COMPONENTS.
SEE ELECTRICAL FOR RECIRCULATION OF EXISITNG OUTLETS
REQUIRED IN THESE SPACES.
REMOVE EXISITNG HVAC UNITS. SALVAGE FOR REINSTALLATION.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS.
REMOVE EXISING CEILING TILE AND GRID. INSTALL NEW TILE AND
GRID - SEE A8.2. REINSTALL EXISITNG CEILING MOUNTED FIXTURES
AND DEVICES IN NEW CEILING.
SPECIFIC NOTES:
HATCHED REGION GENERALLY INDICATES PORTION
OF EXISTING BUILDING TO BE DEMOLISHED. REFER
TO SPECIFIC NOTES FOR ADDITIONAL
INFORMATION.
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S ou th C ou rt
St re et
M on tg om er y, A L
Te l.
4.
. 5
W
W W
.S
SL
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A1.2
LEVEL 2
DEMOLITION
PLAN
F-
: A D
A L
SQ
U
A D
RO
N
O
PE
RA
TI
O N
S
BU
IL
D
IN
G
D
A N
N E
LL
Y
F
IE
LD
M
O N
TG
O
M E
RY
, A
LA
BA
M A
10065.02
JUNE 2022
ME, DCD
DCD
1/8" = 1'-0"A1.2
1 LEVEL 2 DEMOLITION PLAN
3 3
A5.2
A5.2
LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
DOTTED LINE GENERALLY INDICATES EXISTING AREAS TO BE
REMOVED, INCLUDING BUT NOT LIMITED TO WALLS,
DOORS, FLOOR COVERING, CEILINGS, ETC... IN CASE OF
UNCERTAINTY PROVIDE WRITTEN REQUEST TO ARCHITECT.
xx SPECIFIC NOTE TAG (SEE
DEMOLITION NOTES)
REMOVE EXISTING BRICK/STONE/METAL VENEER BACK TO EXISTING
SHEATHING SUBSTRATE. REMOVE VENEER ANCHORS AS REQUIRED
TO INSTALL NEW FINISH - SEE WALL SECTIONS. EXISTING WINDOW
ASSEMBLIES AND CANOPY TO ALSO BE REMOVED. REFER TO
FLOOR PLANS FOR LOCATION(S) WHERE WALL IS SCHEDULED FOR
COMPLETE DEMOLITION IN ADDITION TO EXTERIOR VENEER
DEMOLITION. PATCH EXISTING SUBSTRATE AND AIR BARRIER AS
REQUIRED.
EXISTING WINDOW ASSEMBLY TO REMAIN. PROTECT DURING
DEMOLITION. MODIFY CURTAIN WALL ASSEMBLY AS REQUIRED TO
CONVERT INTERMEDIATE MULLION TO JAMB CONDITION.
EXISTING DOWNSPOUT TO REMAIN. MODIFY AS REQUIRED TO
DISCHARGE ONTO NEW LOW ROOF ASSEMBLY.
SPECIFIC NOTES:
HATCHED REGION GENERALLY INDICATES PORTION
OF EXISTING BUILDING TO BE DEMOLISHED. REFER
TO SPECIFIC NOTES FOR ADDITIONAL
INFORMATION.
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
S o u th
C o u rt
S tr ee t
M o n tg o m er y, A
L
T el
. 3 . 5
W W
W .S
S L
A R
C H
.C O
M
NOT FOR
CONSTRUCTION
USE
95%
SUBMITTAL
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
A1.3
DEMOLITION
ELEVATIONS
F -3
A
D A
L S
Q U
This is the start of the file's text. The full file is on GovTribe.