A 6/3/16 FOR REVIEW
90% PROCUREMENT PACKAGE - NOT FOR CONSTRUCTION
00 4' 8'
00 4' 8'
RETURN AIR
FROM HALLWAY
CHWR
CHWS
DESIGN AIR FLOW
PRE-COOLING CAPACITY - WATER
ATMOSPHERIC PRESSURE
COOLING CAPACITY
AIR TEMPERATURE
FLOW RATE REQUIRED
WATER PRESSURE DROP
AIR PRESSURE DROP
DESIGN FACE VELOCITY
TOTAL
SENSIBLE
ENTERING
LEAVING
27.9 PSIA
6,667 S.C.F.M. @14.5 PSIG TSP
1,528,600 BTU/HR
1,398,300 BTU/HR
238.8 DEG. D.B.
116.6 DEG. W.B.
47.8 DEG. D.B.
47.7 DEG. W.B.
178 G.P.M.
5.9 PSI
1.92" W.G.
508 F.P.M.
DESIGN AIR FLOW
PRE-COOLING CAPACITY - DX
ATMOSPHERIC PRESSURE
COOLING CAPACITY
AIR TEMPERATURE
REFRIGERANT TEMPERATURE
REFRIGERANT PRESSURE DROP
AIR PRESSURE DROP
DESIGN FACE VELOCITY
TOTAL
SENSIBLE
ENTERING
LEAVING
SUCTION
LIQUID
27.9 PSIA
6,667 S.C.F.M.
139,200 BTU/HR
92,600 BTU/HR
47.8 DEG. D.B.
47.7 DEG. W.B.
32 DEG.
90 DEG.
3.1 PSI
1.33" W.G.
508 F.P.M.
DESIGN AIR FLOW
RE-COOLING CAPACITY - DX
ATMOSPHERIC PRESSURE
COOLING CAPACITY
AIR TEMPERATURE
REFRIGERANT PRESSURE DROP
AIR PRESSURE DROP
DESIGN FACE VELOCITY
TOTAL
SENSIBLE
27.9 PSIA
6,667 S.C.F.M.
96,200 BTU/HR
74,400 BTU/HR
35.0 DEG. D.B.
34.8 DEG. W.B.
24.7 DEG. D.B.
24.7 DEG. W.B.
5.6 PSI
0.88" W.G.
508.9 F.P.M.
REFRIGERANT TEMPERATURE
SUCTION
LIQUID
20 DEG.
90 DEG.
ENTERING
LEAVING
35.0 DEG. D.B.
34.8 DEG. W.B.
TOTAL HEAT OF REJECTION
CONDENSING CAPACITY - WATER
CONDENSING TEMPERATURE
WATER TEMPERATURE
WATER PRESSURE DROP
FLOW RATE
ENTERING
LEAVING
105.0 DEG.
331,100 BTU/HR
80 DEG.
95 DEG.
3.6 PSI
60 G.P.M.
DESIGN AIR FLOW
SUPPLY FAN DATA
ATMOSPHERIC PRESSURE 27.9 PSIA
6,667 S.C.F.M.
500 HP
460 / 3 / 60
HP
VOLT / PHASE / HERTZ
R.P.M.
GENERAL NOTES:
UNIT CONSTRUCTION SECTION
BASE FRAME- 2" X 6" X 11 GA STRUCTURAL STEEL TUBE, ELECTRICALLY
WELDED
LIFTING LUGS- BOLT DOWN TYPE, FIXED LUGS AROUND UNIT PERIMETER
WITH REMOVABLE LUGS ON DEMOUNT PLANES
UPPER FRAME- 1” X 2” X 16 GA STRUCTURAL STEEL TRIBE,
ELECTRICALLY WELDED
CABINET- FLOOR: 16 GAUGE BRIGHT SPANGLED G90 GALVANIZED STEEL
FLOOR SHEET, 20 GAUGE BRIGHT SPANGLED G90 GALVANIZED STEEL
SUB-FLOOR
WALLS: 18 GAUGE PRE-COATED G90 GALVANIZED STEEL EXTERIOR
ROOFS: 18 GAUGE PRE-COATED G90 GALVANIZED STEEL EXTERIOR
INSULATION- 1” X 1-1/2 LB, DUCT LINER GLUED IN PLACE
PAINT- FRAME: AIR DRIED DARK GRAY EPOXY FINISH
FLOOR: G90 BRIGHT SPANGLED GALVANIZED STEEL USED THROUGHOUT
INTERIOR (WALLS AND ROOF): NONE REQUIRED
EXTERIOR: BAKED DARK GRAY ZINC-RICH EPOXY PRIMER WITH "COLOR
TO MATCH COLOR SHIP" ALKYD ENAMEL TOP-COAT
ACCESS DOORS- PRE-COASTED GALVANIZED STEEL, DOUBLE WALL
CONSTRUCTION, 1” X 1-1/2 LB. INSULATION, WITH FULL HEIGHT
STAINLESS STEEL HINGES AND OMEGA BULB TYPE DOOR GASKET
DOOR LATCHES- VENTLOK 310 ON ALL DOORS
PROVIDE REMOTE MONITORING OF BEARING TEMPERATURES AND
EXCESSIVE VIBRATION.
ENTERING
LEAVING
45 DEG.
59.2 DEG. W.B.
CHILLED WATER
ASL 2500 FT
75 DB/60 WB
F I N
A L
D X
C
O I L
C H
W
C
O I L
CHWS WATER
COOLED
CONDENSING
UNIT
AHU HOUSING
FAN COIL UNIT
P R
E C
O O
L
D X
C
O I L
EXISTING ACU
CHR
CWS
CHWR
CWR
CWS
REFRIGERANT
PIPING
P.O.C.
P.O.C.
MD
MD
4"
MATCH EXISTING MATERIAL
AND SIZE
MD
NEW ACU
CONCEPT
HIGH PRESSURE
RATED MOTORIZED
DAMPERS TO
MATCH EXISTING
(TYP 4)
MD
NOTES:
1. THE DDC CONTROL SYSTEM SHALL PROVIDE MEANS OF ENERGIZING
ANY ONE OF THE ACU AT A TIME. THE RESPECTIVE MOTORIZED
DAMPERS AND VALVES SHALL OPEN OR CLOSE AND BE PROVEN,
PRIOR TO START OF THE ACU, BASED ON WHICH UNIT IS ENERGIZED
AT THE CONTROL PANEL. THE GRAPHIC SHALL BE PROVIDED ON THE
REMOTE WORK STATION.
2. THE UNIT SHALL BE MODULATING TYPE CAPABLE OF PROVIDING AIR
AT THE FOLLOWING:
- AIR TEMP 25°F TO 65°F (FULL RANGE)
- AIR PRESSURE 1 PSIG TO 14.5 PSIG (FULL RANGE)
3. ALL SETPOINTS SHALL BE ADJUSTABLE LOCALLY AS WELL AS AT
REMOTE WORK STATIONS.
4. THE CONTROL SYSTEM SHALL BE COMPATIBLE WITH EXISTING
SIEMENS CONTROL SYSTEM AND ALL REMOTE HOOK UP SHALL BE
PREFORMED BY SIEMENS.
5. THE INTAKE AND OUTLET MOTORIZED DAMPERS OF THE ACU SHALL
BE PROVEN OPEN PRIOR TO START OF THE ACU. THE INACTIVE
UNIT'S MD SHALL REMAIN CLOSED. THE FINAL PRESSURE
ADJUSTMENT (BEYOND VFD REDUCED SPEED CAPABILTY) SHALL BE
AUTOMATICALLY MADE BY THE DDC, BY MODULATING THE
DISCHARGE DAMPER.
ROTARY WHEEL DESICCANT
DRYER WITH HOT AIR
REGENERATION PACKAGE
(EXISTING UNIT'S DATA LISTED BELOW - TO BE VALIDATED AND USE FOR NEW ACU)
VFD
A 6/3/16 FOR REVIEW
90% PROCUREMENT PACKAGE - NOT FOR CONSTRUCTION
(FOR REFERENCE)
HEAT RECOVERY COIL
WITH EXPANSION
TANK & RELIEF VALVE
4"
CONDITIONING COMPONENTS
SUPPLY FAN ASSEM BLY- LAMSON MODEL 1 857-0-0-7-AD OR EQUAL,
SEVEN STAGE HEAVY DUTY CONSTRUCTION WITH CAST IRON INLET &
OUTLET HEADS, SEE ATTACHED LAMS ON SUBMITTAL (6) 1/2” THICK
BASE ISOLATION PADS
SUPPLY FAN MOTOR- 500 HORSEPOWER, 460/3/60 O.D.P., 3600 R.P.M.,
PREMIUM EFFICIENCY TYPE, WITH VFD. THE BLOWER SHALL BE RATED
FOR CONTINUOUS OPERATION.
HIGH PRESSURE DUCT- ALL DUCT AND PIPING DOWNSTREAM OF
BLOWER SHALL BE CONTINUOUSLY WELDED BY AWSD 1-1 CERTIFIED
WELDERS AND PRESSURE TESTED TO 15 PSIG. THE COILS WILL BE
SITUATED SUCH THAT THE HEADERS & RETURN ENDS ARE FULLY
CONTAINED WITHIN THIS HOUSING. REMOVABLE END PANELS WILL BE
PROVIDED IN THE HOUSING SO COILS CAN SLIDE OUT FOR SERVICE AND
INSPECTION. THE ACCESS DOORS WILL BE BOLTED AND PROVIDED WITH
GASKET MATERIAL SUITABLE FOR SPECIFIED OPERATING. ALL
CONNECTIONS WILL BE 125# ANSI FLANGES MADE OF CAST IRON OR
STEEL. ALL DUCT & PIPING TO BE INSULATED WITH 3/4" ARMAFLEX
INSULATION.
UNIT HYDRONIC COOLING- FANCOIL UNIT USING BUILDING CHILLED
WATER AT 45 DEG F. WATER, 4 ROW, 10 ALUMINUM FINS, 12 GPM,
2,400 CFM, 1/4 HP
ELECTRIC HEATING COIL
HEAT RECOVERY COIL