The document provided is the Specifications for Cambium Links, which details the technical requirements for wireless network bridging links required for a federal contract opportunity. The key details are:

The Cambium Links must be capable of transmitting 1 gigabit/second full-duplex reliably over distances up to 10 kilometers, using NIST-certified AES 256-bit encryption and DoD DISA Frequency Management program certified radio equipment. The links must support environmental ranges of -33C to +55C, adaptive auto-scaling channel sizes, Ethernet MTU sizes up to 9600 bytes, and up to 4000 VLANs simultaneously. The radio equipment must be Cambium Networks brand or equivalent. The Department of the Air Force Materiel Command Test Center is seeking to procure 3 Cambium Link Networks through a firm-fixed price contract with a 120-day Period of Performance. The contract will be awarded to the lowest technically acceptable offer.

View the file

Other files

File Type Posted
24QB024 Cambium Links Questions and Answers.pdf PDF
RFQ_FA9101-24-Q-B024-Cambium Links.pdf PDF
Atch 2 - Pricing Worksheet.xlsx XLSX spreadsheet
Atch 3 - Provisions and Clauses.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications for Cambium Links

Parameters:

Wireless network bridging links, provided as paired equipment, capable of transmitting 1 gigabit/second full-duplex reliably over distances up to 10 kilometers, using NIST-certified AES 256-bit encryption, via radio equipment certified by DoD DISA Frequency Management program providing a current and valid J/F12 certification form, using licensed radio frequencies available for use on both DoD and NATO test ranges.

Radio equipment must support environmental ranges of -33C to +55C.

Radio links must offer adaptive, auto-scale channel sizes.

Link equipment must support Ethernet Maximum Transmission Unit (MTU) sizes up to 9600 bytes.

Network interfaces must be either RJ45 or SFP providing 10/100/1000 megabit auto-sensing, full-duplex link speeds.

Network bridge must support up to 4000 VLANs simultaneously.

Equipment must provide web-based management interface to configure all aspects of operational links and encryption and radio traffic. Indoor radio equipment height must be no more than 1 rack-unit.

Products must be brand name, Cambium Networks, or equivalent to the performance of the brand name.

Quantity Needed: 3 systems