Atch 01 Rqmt Doc_Ka Band Amps.pdf
PDF 654 KB Posted
- Attached to
- Ka Band Amplifiers Federal contract opportunity
- Solicitation number
- FA9101-21-Q-2012
About this file
This requirements document outlines the need for a modular Ka band wideband amplifier for the National Radar Cross Section Test Facility at White Sands, New Mexico. The Air Force seeks delivery of 6-10 modular amplifiers by December 31, 2021, each operating between 26.5-40 GHz with a minimum output power of 100W. Contractors must meet technical requirements including gain, power, frequency range, input/output impedance, connectors, pulse characteristics, and reliability. The solicitation requests quotes due by April 23, 2021 and identifies William Hunter as the contracting officer for any questions due by April 9. Offerors must submit performance, schedule, test, and drawing reports on the frequencies outlined to facilitate technical reviews and acceptance.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1 FA9101-21-Q-2012_Combined Synopsis Solicitation.pdf | ||
| Atch 01 Rqmt Doc_Ka Band Amps.pdf | ||
| 1 FA9101-21-Q-2012_Combined Synopsis Solicitation.pdf | ||
| FA9101-21-Q-2012_QnA.pdf | ||
| 1 FA9101-21-Q-2012_Combined Synopsis Solicitation.pdf | ||
| Atch 01 Rqmt Doc_Ka Band Amps.pdf | ||
| Atch 02 FAR DFARS AFFARS Prov and Clauses.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Requirements Document
FOR
National Radar Cross Section Test Facility (NRTF)
Modular Ka Band Wideband Amplifier
TABLE OF CONTENTS
1. INTRODUCTION
2. PERIOD OF PERFORMANCE
3. PROJECT SCHEDULE
4. TECHNCAL INTERCHANGE AND ACCEPTANCE
5. REQUIRED DOCUMENTS
6. CONTRACTOR CONTACT INFORMATION
1. INTRODUCTION
The US Air Force, National Radar Cross-Section Test Facility (NRTF) at White Sands NM is pursuing a modular design for a wideband, high power, pulsed Ka band amplifier to augment the current Tier III RAMS facility. The Contractor shall meet the minimum requirements stated in this Requirements Document and Appendix 1.0
The design shall be based on integrating and phase cohering 8 (100 W) modules to achieve the desired output. The NRTF will initially procure between 6-10 (100 W) modules which translates to an integrated amplifier of 8 modules with 2 spares.
2. DELIVERY
Delivery of all modules shall occur no later than 31 Dec 21.
3. PROJECT SCHEDULE
The Contractor shall provide a complete milestone schedule that denotes major activities, demonstrations and acceptance testing.
4. TECHNCAL INTERCHANGE AND ACCEPTANCE
The contractor shall conduct the following reviews:
Kick-off/ Technical Interchange Meeting (TIM)
Mid-Term Program Management and Progress Meeting
Acceptance Test (PCA/FCA)
Assembly Drawings
Theory and Operation Manual
These meeting shall be conducted in a format of the Contractor’s choosing and shall cover the overall technical approach, constraints, methods and techniques being examined, performance metrics and results.
5. REQUIRED DOCUMENTS
The Contractor shall provide performance to plan status reports and schedule updates to the AF
Project Manager per the frequency in Table 5-1. All documents are subject to Government acceptance and approval.
Table 5.1 Reporting Requirements
Document Format Frequency
Project Status
Report
MS Word document or email Monthly
Milestone Schedule MS Project, Word, or Excel file
Updated Monthly
PCA Results MS Word 30 Days post milestone
FCA Results MS Word 30 days post milestone
6. CONTRACTOR CONTACT INFORMATION
Upon notice of award, the Contractor shall provide the Contracting Officer and the Government
Project Manager the names and contact information (address, phone number, and email) of a minimum of two (2) Contractor representatives, preferably the contracting agent and project leader.
Any changes in the contact information will immediately be updated by the Contractor as they occur during the duration of this contract and be provided to the Contracting Officer and the
Government Project Manager.
Assembly
Drawings
IGES, DXF, DWG
Compatible
30 days post PCA/FCA
Theory and
Operations Manual
Word or PDF 30 days post PCA/FCA
Frequency 32 GHz to 38 GHz minimum acceptable, 26.5 GHz to 40 GHz desired
Rated OP Pulse: 100 W minimum 130 W nominal
Gain @ rated output power: 50 dB
Prime Power: 120 VAC +/-10%, 50/60 Hz, 1 Phase, or 28VDC via Ext. Power Supply
Input/output Impedance: 50 ohms (VSWR 2.0:1)
RF I/O Connectors: Female 2.92 mm RF In/ WR28 (UG-599/U Flange, 4-40 Threaded) HP Out
Input/output VSWR: 2.0:1
PRF Range: 0 – 100 KHz
Duty Cycle: 10% minimum requirement, 20% desired
Output Power On/Off ratio > 80 dB
TX Bracket (Gating) Pulse Input: BNC Female 50 Ohm TTL Level Rear Panel
TX Bracket Pulse to Pulse Jitter: ±5 ns maximum
TX Bracket Pulse Width Jitter: ±5 ns maximum
Input Pulse to Output Pulse Delay: 500 ns nominal
Spurious Output < 50 dBc
RF Pulse Rise & Fall Time: 30-50 ns maximum
RF Pulse Recovery Time 150 ns (Trailing edge to Leading edge for 2 100 ns pulses within one gate)
RF Pulse to Pulse Stability: 0.2 dB maximum
RF Pulse to Pulse Phase Noise ± 1° Maximum peak to peak
RF Pulse Width 80 ns to 5 sec
RF Pulse Droop <0.5 dB
RF Pulse Overshoot ≤ 5%
RF Pulse Rise and Fall time ≤20 ns from 10% to 90% point
Temperature: 0º to 50º C
Non-operating Temp: -20º to 70º C (50,000 feet max)
Altitude: 10,000 feet
Cooling System: Air cooled, self contained
Modulation: AM/FM/Pulse
Configuration: 5”H x 8”W x 13”D (2 Hub units side by side) must fit in 19” rack shelf width
VSWR Protection against any output mismatch; will operate without damage or oscillation against any magnitude and phase of source and load impedance.
Ethernet Remote Control
Configured to obtain rated output power with an input level of 0 dBm or less.
RF Input Connectors type 2.92mm Female on the Rear Panel
RF Output type WR28 Waveguide on the Rear Panel
Internal Systems Diagnostics with Fault status reporting
Remote Ethernet control for: Power On, Power Off, Status, Operate, Standby and Reset. Commands echoed back with status response.
Lead-Time: Delivery no later than 10 Dec 21
Warranty: 1 Year minimum
Additional Comments: Quotes should include a nominal output power vs frequency plot
Options
For rack mount chassis or modular units, no more than 5 ¼” vertical space for approx. 200 watt output. So for instance for 400 watts no more than 10 ½” vertical rack space, 21” for 800 watts, etc. Units may either be rack mount chassis or shelf mounted as long as forced air cooling is part of the unit(s), they will be housed in an air conditioned enclosure. Depth may be up to 32” deep as long as there is room for external waveguide and combining routing in the case of multiple units being phase combined to achieve desired power output. This is in a 36” deep enclosure so plan accordingly.
Physical Space Limitations:
File details come from the government source that posted it. Updated .