SOW_899.pdf
PDF 68 KB Posted
- Attached to
- Building 899 & 912 IDS Security Upgrade Federal contract opportunity
- Solicitation number
- FA9101-19-Q-0057
About this file
Building 899 Statement of Work
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_7.15.2019.docx | DOCX document | |
| RFI_7.8.2019.docx | DOCX document | |
| Bldg_912_SOW.docx | DOCX document | |
| BLDG_899_and_912_BNJ_Redacted-12.6.pdf | ||
| FA9101-19-Q-0057_BLDG_899_&_912_Security_Combined_Synopsis.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Distribution authorized to Department of Defense and U.S. DoD contractors only; vulnerability information; March 2019. Other requests for this document shall be referred to AEDC/TSTB, Arnold AFB, TN 37389.
For unclassified limited documents, destroy by any method that will prevent disclosure of contents or reconstruction of the document.
INFORMATION RELEASE AUTHORIZATION #4464
STATEMENT OF WORK (SOW)
FOR BUILDING 899
Arnold Protective Services
TSD/IP
ARNOLD AIR FORCE BASE, TN 37389
25 February 2019 information; March 2019. Other requests for this document shall be referred to AEDC/TSTB, Arnold AFB, TN 37389.
For unclassified limited documents, destroy by any method that will prevent disclosure of contents or reconstruction of the document.
INFORMATION RELEASE AUTHORIZATION #4464
Statement of Work
Introduction:
The work will take place in Bldg. 899. The work will consist of installing an Intrusion Detection System (IDS) to the Honeywell Vindicator V5/Site Commander control unit and adding sensors to meet the physical security criteria of AF 31-101 and NISPOM to make Building 899, Arnold AFB, TN a secure area.
IDS Requirements:
A V5 Site Commander/Premise Control unit will be installed in Bldg. 899 inside and next to the downstairs doorway.
ACS Requirements:
The ACS shall provide access control for seven (7) exterior doors. There are two (2) interior doors on each floor that will be monitored by Bestlock Ciphers.
The interior doors will have door contacts installed. There are four (4) rooms upstairs and four (4) rooms downstairs that require motion sensors. The downstairs has a false ceiling and will require above ceiling sensors as well.
The ACS shall employ the following technologies:
1) Identification (ID) badge or card used in conjunction with the access control device that validates the identity of the person to whom the card is issued.
2) A personal identification number (PIN) that is entered into the keypad by each individual. The PIN must be at least four or more digits.
The ACS shall have remote access capabilities and will be integrated with LAN/WAN system.
information; March 2019. Other requests for this document shall be referred to AEDC/TSTB, Arnold AFB, TN 37389.
For unclassified limited documents, destroy by any method that will prevent disclosure of contents or reconstruction of the document.
INFORMATION RELEASE AUTHORIZATION #4464
The above areas will also have white noise generators installed in both the upstairs and downstairs rooms.
Technical Qualifications:
The system is to be designed, furnished, installed, and tested in accordance with Underwriters Laboratories (UL) Standards for National Industrial Security Systems for the Protection of Classified Material, UL 2050.
The IDS will be Honeywell Vindicator technology and the installer must be Vindicator certified in order to be compatible with the current monitoring system.
Installed equipment must be on the Air Force approved equipment list as described in the Air Force Security Forces Center, Non-Nuclear IDS Approval Letter dated 13 Apr 18 or most recent if superseded.
This can be provided if needed.