Night_Vision_Goggle_Brackets_Specifications_30JAN17.docx

DOCX document 14 KB Posted

Attached to
NVG Brackets
Solicitation number
FA8601-17-R-0008
Issued by

About this file

Specifications

View the file

Other files

File Type Posted
FA8601-17-R-0008_3FEB17.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Night Vision Goggle Bracket Specifications 30 January 2017

Specifications:

All proposals must contain adequate information that the Night Vision Goggle Brackets proposed comply with Night Vision Goggle Bracket (NSN: 5340-01-509-1467). Technical Manual, 10-8470-204-10, Technical Manual for Advanced Combat Helmet (ACH), dated 1 August 2015, part number: A3297307.

Ballistic Bolts and Nuts (hardware) contained with the bracket must have passed U.S. Army Ballistic Verification Tests. A copy of the approved Ballistic Test Report from U.S. Army Aberdeen Test Center and approved Ballistic Test Report grading with PM SPE (US Army PEO Soldier) must be contained in all proposals.

Color: Tan Delivery Location: Consolidated Mobility Bag Activity (CMBA) located at Wright-Patterson Air Force Base, OH

CLIN 0001

Quantity: 12,000 Units
Delivery: Within 60 days of Award
CLIN 0002
Quantity: 15,000 Units
Delivery: Within 120 days of Award
CLIN 0003
Quantity: 19,000 Units
Delivery: Within 240 days of Award
CLIN 0004 – OPTION
Quantity: 14,000 Units
Delivery: Within 60 days of Exercise of Option

The contractor does not have to ship 100% of the units at one time. The contractor must deliver in quantities of 1,000 until 100% of the units are delivered.

Delivery Procedures Commercial Vehicles All vehicles larger than a large pick-up truck are required to be inspected by the Wright-Patterson Air Force Base Commercial Vehicle Delivery Gate (CVDG) prior to entering the installation. Vehicles to be inspected include, but are not limited to, the following:

1. Step van/panel truck

2. Tractor/trailer, box and flat bed containing cargo

3. Tanker trucks

4. Box trucks

5. Tour buses

6. Garbage/recycled waste trucks

7. Concrete trucks/mixers, dump trucks

8. Cranes, recreational vehicles, petroleum tanker This inspection will be conducted at Gate 16A located off State Route 444.

The following are exemptions to vehicles utilizing the CVDG:

1. If the vehicle has the product inside (concrete and asphalt trucks) and timely delivery is necessary due to product deterioration it does not need to enter the CVDG. To bypass the CVDG, the contractor shall submit a list containing drivers’ names, social security numbers and the state in which the driver's license is held for those drivers who will be entering the base. This shall be accomplished 24 hours prior to requested entry time. If entry is requested on Monday, this list must be submitted by Friday at 1630 hours. All lists shall be submitted to the 88th ABW/CE Directorate contract inspector. The only gates that may be used under this exemption shall be 15A, 26A, 38A, and gate 1B. If the driver's name is not on the list, he/she will not be allowed access to the installation through these gates and the base will not assume liability for denied access.

2. If a delivery vehicle must exit, and then re-enter the base to complete its route, the vehicle shall be resealed upon exiting the base. After initially passing through the commercial vehicle delivery gate, trucks shall be resealed at Gates 15A, 38A and 22B. The resealing of the trucks will allow them to continue to any other area of the installation (Areas A, B, or Kittyhawk) without reprocessing through the CVDG. To receive resealing assistance, the drivers shall physically stop at one of the three authorized gates and request the installation entry controller to reseal their truck and provide the next location of their delivery. The controller will reseal the truck and give the delivery driver a pre-clearance form. The driver shall present the pre-clearance form to the entry controller at the next point of installation entry. This reentry can be through any base gate.

Vehicles may be subject to an inspection at any of installation entry control points during a directed random antiterrorism measure (RAM.) Any commercial vehicle, regardless of size, can be directed to the CVDG at the discretion of the installation entry controller.

File details come from the government source that posted it. Updated .