NEW KEYED NOTE
REVISION/CHANGE
BUILDING SECTION
DEMO. KEYED NOTE
DRAWING SYMBOLS
END OF SECTION
DRAWING SHEET
NUMBER
DRAWING
REFERENCE NUMBER1
A101
SIM
A101
SIM
WINDOW/LOUVER TAG
101 101
W1
DETAIL C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
COVER SHEET G-001
20-JAN-2016DL
DTBB
WRIGHT-PATTERSON AIR FORCE BASE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJECT NUMBER: ZHTV051863
G-001 COVER SHEET
AD101A HIGH BAY PARTIAL FLOOR PLAN - DEMO
AD101B HIGH BAY PARTIAL FLOOR PLAN - DEMO
AD301 INTERIOR WEST WALL ELEVATION - DEMO
AD302 INTERIOR NORTH WALL ELEVATION - DEMO
AD303 INTERIOR EAST WALL ELEVATION - DEMO
AD304 INTERIOR SOUTH WALL ELEVATION - DEMO
AD305 PHOTOS
AD306 PHOTOS
A-101A HIGH BAY PARTIAL FLOOR PLAN
A-101B HIGH BAY PARTIAL FLOOR PLAN
A-301 INTERIOR WEST WALL ELEVATION
A-302 INTERIOR NORTH WALL ELEVATION
A-303 INTERIOR EAST WALL ELEVATION
A-304 INTERIOR SOUTH WALL ELEVATION
A-401 WINDOW TYPES
A-402 DETAILS
INDEX OF DRAWINGS
LOCATION MAP VICINITY MAP AERIAL VIEW
SITE
SITE
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20.
2. THE WPAFB RECYCLING CENTER IS AVAILABLE FOR CONTRACTOR USE TO REDUCE WASTE DISPOSAL. ALL
RECYCLABLE METAL IS TO BE RECYCLED THROUGH THE BASE RECYCLING CENTER. OTHER RECYCLABLE MATERIALS THAT ARE COST EFFECTIVELY SEGREGATED FROM DEMOLITION DEBRIS AND ARE NOT SCHEDULED FOR OFF-SITE RECYCLING CAN BE TURNED INTO THE WPAFB RECYCLING CENTER IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20. CONTACT WPAFB RECYCLING PROGRAM MANAGER AT 937-257-5060 TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO COORDINATE TURN-IN. THE CONTRACTOR SHALL SUBMIT A QUARTERLY SUMMARY REPORT TO THE GOVERNMENT CONTRACT REPRESENTATIVE IAW WPAFB SPECIFICATION SECTION 01 02 20 STATING (1) THE TONNAGE OF DIVERTED CONSTRUCTION AND DEMOLITION MATERIALS AND CORRESPONDING WEIGHT SLIPS (I.E., RECYCLED, REUSED) (2) THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS LAND-FILLED OR OTHERWISE DISPOSED OF, (3) THE DOLLAR AMOUNT EARNED BY RECYCLING, AND (4) EXPLANATION OF THE DIVERSION RATE IF LESS THAN 50%. THE QUARTERLY SUMMARY REPORTS SHALL BE RECEIVED ON APRIL 7, JULY 7, OCTOBER 7, AND JANUARY 7 COVERING THE THREE MONTHS PRIOR. FOR ADDITIONAL INFORMATION, CONTACT THE RECYCLING PM, DAVE
DALTON, AT 937-257-5060 OR DAVID.DALTON.2@US.AF.MIL
3. TURN-IN ALL MERCURY CONTAINING DEVICES, SWITCHES AND THERMOSTATS TO 88 CEG/CEIE IN ACCORDANCE
WITH WPAFB SPECIFICATION SECTION 01 02 20 FOR RECYCLING.
4. TURN-IN ALL MERCURY CONTAINING LAMPS TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB SPECIFICATION
SECTION 02 08 34.
5. TURN-IN ALL PCB CONTAINING LIGHT BALLAST TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB SPECIFICATION
SECTION 02 08 33
6. REMOVE AND DISPOSE OF ANY ASBESTOS CONTAINING MATERIAL (ACM) ASSOCIATED WITH THE WALLS, STRUCTURAL ELEMENTS AND EQUIPMENT; INCLUDING ALL WATER DAMAGED BUILDING WALL COMPONENTS IN
ACCORDANCE WITH WPAFB SPECIFICATION SECTION 02 08 10.
7. ANY LEAD CONTAINING PAINT CONTROL MEASURES SHALL BE PERFORMED IN ACCORDANCE WITH WPAFB
SPECIFICATION SECTION 02 09 00.
8. RECOVER AND RECLAIM ANY REFRIGERANT IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 02 09 10.
9. ANY USE OF RADIOACTIVE MATERIALS BY THE CONTRACTOR, INCLUDING MOISTURE DENSITY GAUGES, MUST
BE APPROVED BY THE WPAFB RADIATION SAFETY OFFICER A MINIMUM OF 30 DAYS PRIOR TO BEING BROUGHT ONTO WPAFB. THIS REQUIREMENT IS FROM WPAFBI 40-201 AND WPAFB SPECIFICATION SECTION 01 02 20.
10. NO ASBESTOS-CONTAINING MATERIAL SHALL BE INSTALLED DURING THIS PROJECT.
11. 30 DAYS PRIOR TO START OF WORK, THE CONTRACTOR SHALL TAKE A REPRESENTATIVE SAMPLE OF THE HVAC
SYSTEM WATER TO DETERMINE WHETHER IT CAN BE DRAINED DIRECTLY INTO THE SANITARY SEWER.
ANALYZE THE WATER TO DETERMINE THE TOTAL LEVEL OF EACH OF THE FOLLOWING: CADMIUM, CHROMIUM, COPPER, CYANIDE, LEAD, MERCURY, MOLYBDENUM, NICKEL, SILVER, ZINC AND SULFIDE. THE LAB PERFORMING THE ANALYSES MUST BE CERTIFIED BY OHIO EPA TO ANALYZE FOR THESE PARAMETERS. PROVIDE A COPY OF THE LAB'S REPORT TO THE CONTRACTING OFFICER, WHO WILL IN TURN FORWARD IT TO 88 CEG/CEIEA FOR A
DETERMINATION ON THE WASTEWATER DISPOSAL METHOD.
12. ALL WINDOW AND DOOR FRAME CAULKING AND GLAZING WILL BE TREATED AS CONTAINING ASBESTOS UNLESS
TESTING PROVES IT TO BE ASBESTOS FREE.
13. REMOVE ALL ABANDONED EQUIPMENT AND COMPONENTS ON (OR AT) THE WALLS, AS NOTED ON THE
DRAWINGS AND SPECIFICATIONS.
14. ANY WOOD STUD REPLACEMENT DUE TO DETERIORATION SHALL ALSO INCLUDE REATTACHMENT OF EXTERIOR
FIBERGLASS PANEL SIDING TO THE NEW WOOD STUDS.
15. EXISTING BATT INSULATION REMOVAL WILL OCCUR AFTER THE REMOVAL OF THE ASBESTOS CONTAINING
MATERIAL (ACM) WALL PANELS.
16. THE BUILDING WILL REMAIN OCCUPIED FOR THE ENTIRE DURATION OF THE CONSTRUCTION PROJECT.
CONTRACTOR WILL BE GIVEN ACCESS TO ONE WALL, PLAN NORTH, SOUTH, EAST AND WEST WITHIN THE HANGER, AT A TIME. ALL WORK MUST BE COMPLETED ON EACH WALL BEFORE APPROVAL WILL BE GIVEN TO
PROCEED WITH THE NEXT WALL.
17. FACILITY OPERATING HOURS ARE FROM 06:30AM TILL 16:30PM (04:00PM) MONDAY THRU FRIDAY, EXCLUDING FEDERAL HOLIDAYS. ALL CONSTRUCTION AREAS ARE TO BE CLEANED UP DAILY AND ALL CONSTRUCTION PERSONNEL WILL BE REQUIRED TO VACATE THE FACILITY BY 16:30PM, NO EXCEPTIONS WILL BE GRANTED.
GENERAL NOTES
AD304
AD301
MATCH LINE
IMAGE 8/AD306IMAGE 6/AD306IMAGE 10/AD306
IMAGE 1/AD306
IMAGE 9/AD306
IMAGE 17/AD305
IMAGE 6/AD305
(INSIDE INTERIOR
BLDG.)
IMAGE 20/AD305
AD302
SEE 1/AD302 AND
IMAGE 11/AD306
FOR KEYNOTES
ABOVE
ABOVE
016023
024023
012 003
004 004
006005002
ABOVE
EXISTING WINDOW AND GLASS BLOCK TO BE
REMOVED - WGC THAT CONTAINS ASBESTOS
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING LOUVER TO BE REMOVED
EXISTING ACM PANELS AND INSULATION
TO BE REMOVED AND DISPOSED
EXISTING DUCTWORK TO BE REMOVED
EXISTING WALLS AND COLUMNS TO REMAIN
EXISTING OVERHEAD DOOR TO BE REMOVED
EXISTING ACM PANELS, INSULATION AND
WOOD FRAME TO BE REMOVED AND DISPOSED
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
HIGH BAY PARTIAL FLOOR PLAN - DEMO AD101A
20-JAN-2016DL
DTBB
N SCALE : 3/32" = 1'-0"
HIGH BAY PARTIAL FLOOR PLAN - DEMO (PLAN CUT 10'-0" A.F.F.)
SYMBOLS LEGEND KEY PLAN
012 EXISTING FRAME ON THE WALL TO BE REMOVED.
016 EXISTING JIB CRANE TO BE REMOVED.
020 EXISTING METAL TRACK TO BE REMOVED.
021 EXISTING INTERIOR BUILDING AND ASSOCIATED WALL MOUNTED
EQUIPMENT TO BE REMOVED BY OWNER PRIOR TO START THIS
CONTRACT.
022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.
023 EXISTING ALUMINUM SCREEN AND ABANDONED PIPES TO BE
REMOVED.
024 EXISTING EMERGENCY STOP LIGHTS AND SIGNS TO BE REMOVED,
INCLUDING CONDUIT AND CIRCUIT BACK TO EXISTING PANEL.
001 EXISTING DUCTWORK TO BE REMOVED.
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND
(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE
SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE
PROPERLY DECONTAMINATED.
003 EXISTING CLERESTORY GLASS BLOCK TO BE REMOVED.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED.
005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO
REMAIN.
010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE
REMOVED.
AD303
AD304
MATCH LINE
IMAGE 14/AD305
IMAGE 1/AD305,
IMAGE 2/AD305,
IMAGE 7/AD305
IMAGE 3/AD305,
IMAGE 4/AD305
IMAGE 5/AD305
IMAGE 16/AD305
IMAGE 9/AD305,
IMAGE 11//AD305
IMAGE 15/AD305
IMAGE 8/AD305
IMAGE 7/AD306
AD302
SEE 1/AD302 AND
IMAGE 11/AD306
FOR KEYNOTES
ABOVEABOVE
022004
006005
006005002
004 010 014
018 019
004 014 018 019
004 010
025 026
010011010
EXISTING WINDOW AND GLASS BLOCK TO BE
REMOVED - WGC THAT CONTAINS ASBESTOS
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING LOUVER TO BE REMOVED
EXISTING ACM PANELS AND INSULATION
TO BE REMOVED AND DISPOSED
EXISTING DUCTWORK TO BE REMOVED
EXISTING WALLS AND COLUMNS TO REMAIN
EXISTING OVERHEAD DOOR TO BE REMOVED
EXISTING ACM PANELS, INSULATION AND
WOOD FRAME TO BE REMOVED AND DISPOSED
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
HIGH BAY PARTIAL FLOOR PLAN - DEMO AD101B
20-JAN-2016DL
DTBB
N SCALE : 3/32" = 1'-0"
HIGH BAY PARTIAL FLOOR PLAN - DEMO (PLAN CUT 10'-0" A.F.F.)
SYMBOLS LEGEND KEY PLAN
010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE
REMOVED.
011 EXISTING METAL AND WOOD SCAFFOLDING TO BE REMOVED.
012 EXISTING FRAME ON THE WALL TO BE REMOVED.
013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC
SHALL BE ABATED PER BASE SPECIFICATIONS.
014 EXISTING ABANDONED METAL DUCT TO BE REMOVED.
018 CONTRACTOR TO PROTECT EXISTING CONDUIT AND EQUIPMENT TO
REMAIN ON THE WALL.
019 EXISTING METAL PANEL AND WALL COMPONENTS TO BE REMOVED.
022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.
025 EXISTING GLASS BLOCK TO REMAIN.
026 EXISTING GLASS BLOCK TO REMAIN BEHIND EXISTING DUCTWORK TO
BE REMOVED.
001 EXISTING DUCTWORK TO BE REMOVED.
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND
(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE
SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE
PROPERLY DECONTAMINATED.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED.
005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO
REMAIN.
008 EXISTING OVERHEAD DOOR, FRAME, AND COUNTER WEIGHTS TO BE
REMOVED. PATCH AND FILL EXISTING BOLTED CONNECTION HOLES
WITH EPOXY GROUNT, PAINT.
Level 1 0"
Low Roof 64' - 0"
Mid Roof 101' - 8"
High Roof 131' - 0"
AD304
004 015
002 002 002 002
002 002 002 002
002002 002
004 004
003 003
IMAGE 6/AD306
IMAGE 10/AD306
IMAGE 8/AD306
AD302
002002002002002
IMAGE 11/AD306
IMAGE 11/AD306
IMAGE 11/AD306
015 015
007 001
013013
BEHIND SCREEN
IMAGE 2/AD306
EXISTING WINDOW AND GLASS BLOCK TO BE
REMOVED - WGC THAT CONTAINS ASBESTOS
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING LOUVER TO BE REMOVED
EXISTING ACM PANELS AND INSULATION
TO BE REMOVED AND DISPOSED
EXISTING DUCTWORK TO BE REMOVED
EXISTING WALLS AND COLUMNS TO REMAIN
EXISTING OVERHEAD DOOR TO BE REMOVED
EXISTING ACM PANELS, INSULATION AND
WOOD FRAME TO BE REMOVED AND DISPOSED
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR WEST WALL ELEVATION - DEMO AD301
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR WEST WALL ELEVATION - DEMO
SYMBOLS LEGEND
015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,
INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.
EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED
TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10
SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED
GASKET @ MAX. FASTENER SPACING OF 16” O.C.
016 EXISTING JIB CRANE TO BE REMOVED.
021 EXISTING INTERIOR BUILDING AND ASSOCIATED WALL MOUNTED
EQUIPMENT TO BE REMOVED BY OWNER PRIOR TO START THIS
CONTRACT.
023 EXISTING ALUMINUM SCREEN AND ABANDONED PIPES TO BE
REMOVED.
024 EXISTING EMERGENCY STOP LIGHTS AND SIGNS TO BE REMOVED,
INCLUDING CONDUIT AND CIRCUIT BACK TO EXISTING PANEL.
029 EXISTING MEZZANINE HAS ALREADY BEEN REMOVED BY OWNER.
001 EXISTING DUCTWORK TO BE REMOVED.
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND
(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE
SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE
PROPERLY DECONTAMINATED.
003 EXISTING CLERESTORY GLASS BLOCK TO BE REMOVED.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED.
005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO
REMAIN.
013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING WINDOW AND GLASS BLOCK TO BE
REMOVED - WGC THAT CONTAINS ASBESTOS
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING LOUVER TO BE REMOVED
EXISTING ACM PANELS AND INSULATION
TO BE REMOVED AND DISPOSED
EXISTING DUCTWORK TO BE REMOVED
EXISTING WALLS AND COLUMNS TO REMAIN
EXISTING OVERHEAD DOOR TO BE REMOVED
EXISTING ACM PANELS, INSULATION AND
WOOD FRAME TO BE REMOVED AND DISPOSED
Level 1 0"
Low Roof 64' - 0"
Mid Roof 101' - 8"
High Roof 131' - 0"
AD303
AD301
001 001 001
004 004 004
004 004
004 004 004
009 002 009 009 009 009002 002 002
004 004 004 004004 004004 004 004 004
004004
IMAGE 17/AD305
IMAGE 14/AD305,
IMAGE 20/AD305
IMAGE 7/AD305 IMAGE 5/AD305
IMAGE 11/AD306
IMAGE 11/AD306
015 017017017017 017 017 017 017 017
017 015
018 019 013013
IMAGE 19/AD305
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR NORTH WALL ELEVATION - DEMO AD302
20-JAN-2016DL
DTBB
SYMBOLS LEGEND
SCALE : 3/32" = 1'-0"1 INTERIOR NORTH WALL ELEVATION - DEMO
021 EXISTING INTERIOR BUILDING AND ASSOCIATED WALL MOUNTED
EQUIPMENT TO BE REMOVED BY OWNER PRIOR TO START THIS
CONTRACT.
022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.
027 EXISTING NORTH WALL DOORS TO REMAIN.
028 EXISTING STEAM GENERATION UNIT TO BE REMOVED.
014 EXISTING ABANDONED METAL DUCT TO BE REMOVED.
015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,
INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.
EXISTING EXTERIOR METAL PANELS WILL NEED TO BE
RE-ATTACHED TO THE REPLACED WOOD STUD FRAMING WITH MIN.
1-1/2” #10 SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH
INSULATED GASKET @ MAX. FASTENER SPACING OF 16” O.C.
017 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED. INSPECT EXISTING
WOOD FRAME FOR WATER DAMAGE AND REPLACE AS REQUIRED.
EXISTING EXTERIOR METAL PANELS WILL NEED TO BE
RE-ATTACHED TO THE REPLACED WOOD STUD FRAMING WITH MIN.
1-1/2” #10 SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH
INSULATED GASKET @ MAX. FASTENER SPACING OF 16” O.C.
018 CONTRACTOR TO PROTECT EXISTING CONDUIT AND EQUIPMENT TO
REMAIN ON THE WALL.
019 EXISTING METAL PANEL AND WALL COMPONENTS TO BE REMOVED.
020 EXISTING METAL TRACK TO BE REMOVED.
001 EXISTING DUCTWORK TO BE REMOVED.
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING
COMPOUND (WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED
PER BASE SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS
SHOULD BE PROPERLY DECONTAMINATED.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED.
005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
009 EXISTING LOUVER TO BE REMOVED.
010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO
BE REMOVED.
013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC
SHALL BE ABATED PER BASE SPECIFICATIONS.
Low Roof 64' - 0"
Mid Roof 101' - 8"
High Roof 131' - 0"
AD304
002004 002 002 002 002002 002 002 002 002
002002002002
015 004
002 002
AD302
002002002002002
IMAGE 11/AD306
IMAGE 11/AD306
IMAGE 11/AD306
015 015
004002
EXISTING WINDOW AND GLASS BLOCK TO BE
REMOVED - WGC THAT CONTAINS ASBESTOS
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING LOUVER TO BE REMOVED
EXISTING ACM PANELS AND INSULATION
TO BE REMOVED AND DISPOSED
EXISTING DUCTWORK TO BE REMOVED
EXISTING WALLS AND COLUMNS TO REMAIN
EXISTING OVERHEAD DOOR TO BE REMOVED
EXISTING ACM PANELS, INSULATION AND
WOOD FRAME TO BE REMOVED AND DISPOSED
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR EAST WALL ELEVATION - DEMO AD303
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR EAST WALL ELEVATION - DEMO
SYMBOLS LEGEND
012 EXISTING FRAME ON THE WALL TO BE REMOVED.
015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,
INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.
EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED
TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10
SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED
GASKET @ MAX. FASTENER SPACING OF 16” O.C.
025 EXISTING GLASS BLOCK TO REMAIN.
026 EXISTING GLASS BLOCK TO REMAIN BEHIND EXISTING DUCTWORK TO
BE REMOVED.
001 EXISTING DUCTWORK TO BE REMOVED.
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND
(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE
SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE
PROPERLY DECONTAMINATED.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED.
005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO
REMAIN.
007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO
REMAIN.
008 EXISTING OVERHEAD DOOR, FRAME, AND COUNTER WEIGHTS TO BE
REMOVED. PATCH AND FILL EXISTING BOLTED CONNECTION HOLES
WITH EPOXY GROUNT, PAINT.
Low Roof 64' - 0"
Mid Roof 101' - 8"
High Roof 131' - 0"
AD303
AD301
004004 004 004 004004 004 004 004 004
007 007 007 007 007
015017017017017017017017017017
EXISTING WINDOW AND GLASS BLOCK TO BE
REMOVED - WGC THAT CONTAINS ASBESTOS
SHALL BE ABATED PER BASE SPECIFICATIONS.
EXISTING LOUVER TO BE REMOVED
EXISTING ACM PANELS AND INSULATION
TO BE REMOVED AND DISPOSED
EXISTING DUCTWORK TO BE REMOVED
EXISTING WALLS AND COLUMNS TO REMAIN
EXISTING OVERHEAD DOOR TO BE REMOVED
EXISTING ACM PANELS, INSULATION AND
WOOD FRAME TO BE REMOVED AND DISPOSED
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR SOUTH WALL ELEVATION - DEMO AD304
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR SOUTH WALL ELEVATION - DEMO
SYMBOLS LEGEND
017 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED. INSPECT EXISTING
WOOD FRAME FOR WATER DAMAGE AND REPLACE AS REQUIRED.
EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED
TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10
SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED
GASKET @ MAX. FASTENER SPACING OF 16” O.C.
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND
(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE
SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE
PROPERLY DECONTAMINATED.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND
INSULATION TO BE REMOVED AND DISPOSED.
007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO
REMAIN.
009 EXISTING LOUVER TO BE REMOVED.
015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,
INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.
EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED
TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10
SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED
GASKET @ MAX. FASTENER SPACING OF 16” O.C.
004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND INSULATION TO BE REMOVED AND DISPOSED.
010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE REMOVED.
011 EXISTING METAL AND WOOD SCAFFOLDING TO BE REMOVED.
012 EXISTING FRAME ON THE WALL TO BE REMOVED.
014 EXISTING ABANDONED METAL DUCT TO BE REMOVED.
018 CONTRACTOR TO PROTECT EXISTING CONDUIT AND EQUIPMENT TO REMAIN ON THE WALL.
019 EXISTING METAL PANEL AND WALL COMPONENTS TO BE REMOVED.
020 EXISTING METAL TRACK TO BE REMOVED.
022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.
028 EXISTING STEAM GENERATION UNIT TO BE REMOVED.
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
PHOTOS AD305
20-JAN-2016DL
DTBB
IMAGE 1/AD305 IMAGE 3/AD305 IMAGE 5/AD305 IMAGE 7/AD305 IMAGE 9/AD305
IMAGE 11/AD305 IMAGE 15/AD305
IMAGE 16/AD305 IMAGE 12/AD305
IMAGE 17/AD305
IMAGE 2/AD305 IMAGE 4/AD305 IMAGE 6/AD305 IMAGE 8/AD305
019 019
IMAGE 14/AD305
020 004
IMAGE 20/AD305
IMAGE 19/AD305
IMAGE 17/AD305
IMAGE 14/AD305
020 004
002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND (WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE PROPERLY DECONTAMINATED.
005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO REMAIN.
006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER EXISTING WIRE REINFORCED CORREGATED GLASS
PANELS TO REMAIN.
010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE REMOVED.
012 EXISTING FRAME ON THE WALL TO BE REMOVED.
013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC SHALL BE ABATED PER BASE SPECIFICATIONS.
016 EXISTING JIB CRANE TO BE REMOVED.
023 EXISTING ALUMINUM SCREEN AND ABANDONED PIPES TO BE REMOVED.
024 EXISTING EMERGENCY STOP LIGHTS AND SIGNS TO BE REMOVED, INCLUDING CONDUIT AND CIRCUIT BACK TO
EXISTING PANEL.
029 EXISTING MEZZANINE HAS ALREADY BEEN REMOVED BY OWNER (SEE AD301).
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
PHOTOS AD306
20-JAN-2016DL
DTBB
IMAGE 7/AD306
IMAGE 1/AD306 IMAGE 6/AD306
IMAGE 8/AD306
IMAGE 10/AD306
IMAGE 9/AD306
IMAGE 11/AD306
IMAGE 2/AD306
A-304
A-301
A-302
105 105105
MATCH LINE
105105
SEE 1/A302 FOR
KEYNOTES
SEE 1/A301 FOR
KEYNOTES
A-402
TYP.
103103
106102
NEW WINDOW SYSTEM - AS SPECIFIED
NEW GLASS BLOCK - AS SPECIFIED
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - ELEVATION
EXISTING WALLS AND COLUMNS TO
REMAIN
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - SECTION
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
HIGH BAY PARTIAL FLOOR PLAN A-101A
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"
HIGH BAY PARTIAL FLOOR PLANN
(PLAN CUT 10'-0" A.F.F.)
SYMBOLS LEGEND KEY PLAN
106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"
OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.
THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR
METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL
IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON
THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE
SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.
101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT
CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR
REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION
BATT INSULATION IN WALL CAVITY (KRAFT FACE).
102 NEW WINDOW SYSTEM - AS SPECIFIED.
103 NEW GLASS BLOCK - AS SPECIFIED.
104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS
HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.
105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND
CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT
THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,
WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF
TRUSSES, METAL DECK AND CRANES. PAINT COLOR "PNT-3" - SEE
SPECS.
A-304
A-303
A-302
105 105
MATCH LINE
105 105
105 105
SEE 1/A302 FOR
KEYNOTES
A-402
TYP.
102 106
NEW WINDOW SYSTEM - AS SPECIFIED
NEW GLASS BLOCK - AS SPECIFIED
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - ELEVATION
EXISTING WALLS AND COLUMNS TO
REMAIN
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - SECTION
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
HIGH BAY PARTIAL FLOOR PLAN A-101B
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"
HIGH BAY PARTIAL FLOOR PLANN
(PLAN CUT 10'-0" A.F.F.)
SYMBOLS LEGEND KEY PLAN
106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"
OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.
THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR
METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL
IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON
THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE
SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.
101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT
CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR
REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION
BATT INSULATION IN WALL CAVITY (KRAFT FACE).
102 NEW WINDOW SYSTEM - AS SPECIFIED.
104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS
HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.
105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND
CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT
THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,
WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF
Low Roof 64' - 0"
A-304
Mid Roof 101' - 8"
High Roof 131' - 0"
A-302
101 101
102 102
101101
A-402
A-402
W1
W2A
W1
W6
W2B
W2A
W2A
W2A
W2B
W2B
W2B
W4
W3W3
W6
W6
W6
101101
NEW WINDOW SYSTEM - AS SPECIFIED
NEW GLASS BLOCK - AS SPECIFIED
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - ELEVATION
EXISTING WALLS AND COLUMNS TO
REMAIN
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - SECTION
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR WEST WALL ELEVATION A-301
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR WEST WALL ELEVATION
SYMBOLS LEGEND
106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"
OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.
THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR
METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL
IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON
THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE
SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.
108 INFILL EXISTING CMU WALL OPENINGS, WHERE DUCTWORK IS
REMOVED. MATCH EXISTING CAVITY WALL CONSTRUCTION, WHERE
OCCURS.
101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT
CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR
REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION
BATT INSULATION IN WALL CAVITY (KRAFT FACE).
102 NEW WINDOW SYSTEM - AS SPECIFIED.
103 NEW GLASS BLOCK - AS SPECIFIED.
104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS
HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.
105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND
CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT
THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,
WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF
Low Roof 64' - 0"
A-301
Mid Roof 101' - 8"
High Roof 131' - 0"
A-303
101101 101 101 101 101 101 101 101 101
101101 101 101
101 101
101 101 101
101101 101 101 101 101 101 101 101 101
102 102 102 102 102 102 102 102 102
W3 W3 W3 W3 W3 W3 W3 W3 W3 W3
W4
IMAGE 11/AD306
NEW WINDOW SYSTEM - AS SPECIFIED
NEW GLASS BLOCK - AS SPECIFIED
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - ELEVATION
EXISTING WALLS AND COLUMNS TO
REMAIN
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - SECTION
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR NORTH WALL ELEVATION A-302
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR NORTH WALL ELEVATION
SYMBOLS LEGEND
101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT
CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR
REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION
BATT INSULATION IN WALL CAVITY (KRAFT FACE).
102 NEW WINDOW SYSTEM - AS SPECIFIED.
107 LINE OF NEW EXTERIOR WALL METAL PANEL ON METAL STUDS AND
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS BEYOND.
109 PRIME AND PAINT EXISTING NORTH WALL DOORS TO REMAIN. PAINT
COLOR "PNT-2" - SEE SPECS.
Low Roof 64' - 0"
A-304
Mid Roof 101' - 8"
High Roof 131' - 0"
A-302
102 102
A-402
A-402
W4
W1
102102
W2A W1
W2B
102 102 102
102102102
W3W3
W2A
W2B
W2A
W2B
W2A
W2B
101101
NEW WINDOW SYSTEM - AS SPECIFIED
NEW GLASS BLOCK - AS SPECIFIED
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - ELEVATION
EXISTING WALLS AND COLUMNS TO
REMAIN
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - SECTION
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR EAST WALL ELEVATION A-303
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR EAST WALL ELEVATION
SYMBOLS LEGEND
106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER
EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"
OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.
THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR
METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL
IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON
THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE
SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.
108 INFILL EXISTING CMU WALL OPENINGS, WHERE DUCTWORK IS
REMOVED. MATCH EXISTING CAVITY WALL CONSTRUCTION, WHERE
OCCURS.
101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT
CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR
REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION
BATT INSULATION IN WALL CAVITY (KRAFT FACE).
102 NEW WINDOW SYSTEM - AS SPECIFIED.
104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS
HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.
105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND
CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT
THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,
WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF
Low Roof 64' - 0"
A-301
Mid Roof 101' - 8"
High Roof 131' - 0"
A-303
101 101 101 101 101 101 101 101 101
104 104 104 104 104
101101 101 101 101 101 101 101 101 101
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
NEW WINDOW SYSTEM - AS SPECIFIED
NEW GLASS BLOCK - AS SPECIFIED
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - ELEVATION
EXISTING WALLS AND COLUMNS TO
REMAIN
NEW INTERIOR WALL METAL PANEL
OVER METAL STUDS - SECTION
SHEET KEYNOTES
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
INTERIOR SOUTH WALL ELEVATION A-304
20-JAN-2016DL
DTBB
SCALE : 3/32" = 1'-0"1 INTERIOR SOUTH WALL ELEVATION
SYMBOLS LEGEND
101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT
CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR
REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION
BATT INSULATION IN WALL CAVITY (KRAFT FACE).
102 NEW WINDOW SYSTEM - AS SPECIFIED.
104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS
HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.
4"
FI
E
LD
V
ER
IF
Y
10 EQ. PANELS = 50' - 0" - FIELD VERIFY
A-402
A-402
TYP. PANEL
5' - 0"
EQ. EQ.
E Q
E
Q
E Q
E
Q
E Q
GL-1 AT WEST WALL
GL-2 AT EAST WALL
4"
FI
E
LD
V
ER
IF
Y
2 EQ. PANELS
10' - 0" FIELD VERIFY
A-402
A-402
A-402
AT W2B AT W2A
TYP. PANEL
5' - 0"
EQ. EQ.
E Q
E
Q
E Q
E
Q
E Q
N E
W R
.O
4" -F
IE
LD
V E
R
IF
Y
3 EQ. PANELS
15' - 0" FIELD VERIFY
A-402
A-402
TYP. PANEL
5' - 0"
EQ. EQ.
E Q
E
Q
E Q
E
Q
E Q
GL-1
8' -1
1"
14' - 10"
A-402
A-402
A-402
N E
W R
.O
4" -F
IE
LD
V E
R
IF
Y
60 EQ. PANELS = 141'-0" - FIELD VERIFY
A-402
A-402
TYP.
1 PANEL
GL-1
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
WINDOW TYPES A-401
20-JAN-2016DL
DTBB
SCALE : 1/4" = 1'-0"
W1
SCALE : 1/4" = 1'-0"
W2A & W2B
SCALE : 1/4" = 1'-0"
W3
SCALE : 1/4" = 1'-0"
W6
SCALE : 1/4" = 1'-0"
W4
REFERENCES:
UFC 3-301-01, 1 JUNE 2013 STRUCTURAL ENGINEERING
UFC 4-010-01, 9 FEBRUARY 2012 CHANGE 1, 1 OCTOBER 2013 DOD MINIMUM ANTITERRORISM
STANDARDS FOR BUILDINGS
ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
WIND DESIGN PARAMETERS
a. BASIC WIND SPEED = 115
b. RISK CATEGORY = II
c. WIND EXPOSURE = C
d. COMPONENTS AND CLADDING – WALLS
AREA (SF) INTERIOR ZONE EDGE ZONE
10 39.2 PSF 71.8 PSF
100 35.5 PSF 57.3 PSF
200 33.7 PSF 50.1 PSF
500 31.9 PSF 42.8 PSF
ANTI-TERRIORISM / FORCE PROTECTION:
a. BUILDING CATEGORY = PRIMARY GATHERING BUILDING (LOW LEVEL OF PROTECTION)
b. STANDOFF DISTANCE = 61 FT. HORIZONTAL DIMENSION; 98 FT. ALONG 51 DEGREE INCIDENCE
ANGLE MEASURED FROM HORIZONTAL
c. APPLICABLE CHARGE WEIGHT = EXPLOSIVE WEIGHT II
STRUCTURAL CODE SUMMARY:
N WALL
HIGH WINDOW: 55'-4 1/4"
E X
IS
TI
N G
R .O
3/ 8"
-F
IE
LD
V
ER
IF
Y
N E
W R
.O
4"
PERFORATED METAL
PANEL
NEW BATT INSULATION,
INSTALLED AS SPECIFIED
INTERIOR PRE-
FINISHED METAL
TRIM
NEW WINDOW
AS SPECIFIED
EXISTING EXTERIOR
WALL TO REMAIN
SEALANT FULL
PERIMETER - TYP.
CONT. 3x2x5/16 STEEL
ANGLE WELD TO
EXISTING FRAME - TYP.
7/8" METAL FURRING
CHANNEL @ 24" O.C.
SEALANT FULL
PERIMETER - TYP.
N WALL LOW WINDOW: 34'-1 1/2"
PERFORATED METAL
PANEL
NEW BATT INSULATION,
INSTALLED AS SPECIFIED
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING WALL METAL
PANEL ON METAL
STUDS TO REMAIN
EXISTING ROOF
NEW EXTERIOR WALL
METAL PANEL ON METAL
STUDS, LAP 4" OVER
EXISTING WALL METAL
PANEL, MATCH PROFILE
7/8" METAL FURRING
CHANNEL @ 24" O.C.
EXISTING METAL
FLASHING TO BE
REMOVED
4"
MI
N.
NEW PRE-FINISHED
METAL FLASHING,
LAP 4" MIN.
EXISTING WIRE REINFORCED
CORREGATED GLASS
PANELS TO REMAIN
4"
MI
N.
4"
MI
N.
NEW 2X WOOD STUDS
INFILL @ 16" O.C. BEHIND
EXISTING WINDOW
ALIGNED
ALIGNED
PERFORATED METAL PANEL
7/8" METAL FURRING CHANNEL @ 24" O.C.
INTERIOR PRE-FINISHED METAL TRIM
NEW WINDOW AS SPECIFIED
NEW BATT INSULATION, INSTALLED AS SPECIFIEDEXISTING EXTERIOR
WALL TO REMAIN
CONT. 3x2x5/16 STEEL
ANGLE WELD TO
EXISTING FRAME - TYP.
SEALANT FULL
PERIMETER - TYP.
PERFORATED METAL PANEL
INTERIOR PRE-FINISHED
METAL TRIM
NEW BATT INSULATION, INSTALLED AS SPECIFIEDEXISTING EXTERIOR
WALL TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
E X
IS
TI
N G
R .O
'-7 3/
8" -F
IE
LD
V
ER
IF
Y
N E
W R
.O
'-4
SEALANT FULL
PERIMETER - TYP.
CONT. 3x2x5/16 STEEL
ANGLE WELD TO
EXISTING FRAME - TYP.
NEW WINDOW
AS SPECIFIED
7/8" METAL FURRING
CHANNEL @ 32" O.C.
SEALANT FULL
PERIMETER - TYP.
NEW METAL
FLASHING
METAL PANEL ANCHOR AS REQUIRED
HORIZONTAL JOINT
REINFORCING
GLASS BLOCK UNIT
MORTAR BED
ASPHALT EMULSION
EXISTING WALL
METAL PANEL ANCHOR
AS REQUIRED
HORIZONTAL JOINT
REINFORCINGGLASS BLOCK UNIT
MORTAR BED
BACKER ROD AND
SEALANT, ON BOTH SIDES
OF GLASS BLOCK UNIT
EXISTING WALL
ALUMINUM ANGLE,
ON BOTH SIDES OF
GLASS BLOCK UNIT EXPANSION STRIP
TREATED WOOD BLOCKING
METAL PANEL
ANCHORS - BEND WITH
EXPANSION JOINT
MORTAR BED
HORIZONTAL JOINT
REINFORCING AS
REQUIRED FOR EACH
INSTALLATION
GLASS
BLOCK UNIT
EXPANSION
STRIP
HORIZONTAL JOINT
REINFORCING
GLASS BLOCK UNIT
MORTAR BED
BACKER ROD AND
SEALANT, ON BOTH SIDES
OF GLASS BLOCK UNIT
EXISTING BEAM OR ROOF
ALUMINUM ANGLE,
ON BOTH SIDES OF
GLASS BLOCK UNIT TREATED WOOD BLOCKING
PERFORATED METAL PANEL
7/8" METAL FURRING CHANNEL @ 24" O.C.
INTERIOR PRE-FINISHED
METAL TRIM
NEW BATT INSULATION,
INSTALLED AS SPECIFIED
EXISTING EXTERIOR
WALL TO REMAIN
WOOD BLOCKING
AS REQUIRED
EXISTING STEEL
COLUMN TO REMAIN
C
IVI
L E N G I N E
E R
88TH ABWWPAFB
WRIGHT-PATTERSON AIR FORCE BASE
COORDINATOR DESIGN CHIEF ENGINEERING CHIEF
DATE NO. REVISION BY NO. REVISION BY
DRAWNDESIGNED CHECKED DATE
OF
US AF
DATE
REMOVE ASBESTOS HIGH BAY, FACILITY 20065
PROJ. NUMBER: ZHTV051863
DETAILS A-402
20-JAN-2016DL
DTBB
SCALE : 1 1/2" = 1'-0"2 WINDOW DETAIL - HEAD & SILL
SCALE : 1 1/2" = 1'-0"1 WALL DETAIL
SCALE : 1 1/2" = 1'-0"5 WINDOW DETAIL - JAMB
SCALE : 1 1/2" = 1'-0"3 WINDOW DETAIL - HEAD & SILL
SCALE : 1 1/2" = 1'-0"7 GLASS BLOCK DETAIL - SILL
NTS6 GLASS BLOCK DETAIL - JAMB
NTS
GLASS BLOCK DETAIL
SCALE : 1 1/2" = 1'-0"8 GLASS BLOCK DETAIL - HEAD
SCALE : 1 1/2" = 1'-0"4 PLAN DETAIL
| G-001 |
| AD101A |
| AD101B |
| AD301 |
| AD302 |
| AD303 |
| AD304 |
| AD305 |
| AD306 |
| A-101A |
| A-101B |
| A-301 |
| A-302 |
| A-303 |
| A-304 |
| A-401 |
| A-402 |
| A-402 |