Draft_Drawings.pdf

PDF 21 MB Posted

Attached to
Project 051863 - Remove Asbestos High Bay, Building 65 Federal contract opportunity
Solicitation number
FA8601-16-B-0001
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

Draft Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Project 051863 - Remove Asbestos High Bay, Building 65, newest first.
File Type Posted
FA8601-16-B-0001_Conformed_Solicitation.pdf PDF
PreAward-RFIs_03.pdf PDF
PreAward-RFIs_02.pdf PDF
SIDING-REPLACEMENTexisting.pdf PDF
Pic_01c.jpg JPG image
Pic_14.jpg JPG image
Pic_02.jpg JPG image
Pic_03a.jpg JPG image
Pic_10.jpg JPG image
Pic_06.jpg JPG image
Pic_11.jpg JPG image
Pic_04.jpg JPG image
Pic_07.jpg JPG image
Pic_05b.jpg JPG image
Pic_01b.jpg JPG image
Pic_08.jpg JPG image
Pic_05a.jpg JPG image
Pic_13.jpg JPG image
Pic_01a.jpg JPG image
Pic_09.jpg JPG image
Pic_15.jpg JPG image
Pic_16.jpg JPG image
Pic_03b.jpg JPG image
Pic_12.jpg JPG image
Addendum_2.pdf PDF
PreAward-RFIs.pdf PDF
AsBuilt-Drawings.pdf PDF
Wage_Determination_OH160102_MOD__12.pdf PDF
FA8601-16-B-0001_Amendment_0001.pdf PDF
Specifications.pdf PDF
Proj_051863_-_Site_Visit_Sign-in_Sheet.pdf PDF
Proj_051863_-_Site_Visit_Info.pdf PDF
FA8601-16-B-0001_Solicitation.pdf PDF
Attach_2_-_DRAWINGS.pdf PDF
Attach_5_-_Wage_Determination_OH160102.pdf PDF
Attach_4_-_Section_01_02_20_Addendum_1.pdf PDF
Attach_3_-_Addendum_1.pdf PDF
Attach_1_-_Specifications.pdf PDF
Draft_Specs.pdf PDF
Show all 39

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW KEYED NOTE

REVISION/CHANGE

BUILDING SECTION

DEMO. KEYED NOTE

DRAWING SYMBOLS

END OF SECTION

DRAWING SHEET

NUMBER

DRAWING

REFERENCE NUMBER1

A101

SIM

A101

SIM

WINDOW/LOUVER TAG

101 101

W1

DETAIL C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

COVER SHEET G-001

20-JAN-2016DL

DTBB

WRIGHT-PATTERSON AIR FORCE BASE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJECT NUMBER: ZHTV051863

G-001 COVER SHEET

AD101A HIGH BAY PARTIAL FLOOR PLAN - DEMO

AD101B HIGH BAY PARTIAL FLOOR PLAN - DEMO

AD301 INTERIOR WEST WALL ELEVATION - DEMO

AD302 INTERIOR NORTH WALL ELEVATION - DEMO

AD303 INTERIOR EAST WALL ELEVATION - DEMO

AD304 INTERIOR SOUTH WALL ELEVATION - DEMO

AD305 PHOTOS

AD306 PHOTOS

A-101A HIGH BAY PARTIAL FLOOR PLAN

A-101B HIGH BAY PARTIAL FLOOR PLAN

A-301 INTERIOR WEST WALL ELEVATION

A-302 INTERIOR NORTH WALL ELEVATION

A-303 INTERIOR EAST WALL ELEVATION

A-304 INTERIOR SOUTH WALL ELEVATION

A-401 WINDOW TYPES

A-402 DETAILS

INDEX OF DRAWINGS

LOCATION MAP VICINITY MAP AERIAL VIEW

SITE

SITE

1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20.

2. THE WPAFB RECYCLING CENTER IS AVAILABLE FOR CONTRACTOR USE TO REDUCE WASTE DISPOSAL. ALL

RECYCLABLE METAL IS TO BE RECYCLED THROUGH THE BASE RECYCLING CENTER. OTHER RECYCLABLE MATERIALS THAT ARE COST EFFECTIVELY SEGREGATED FROM DEMOLITION DEBRIS AND ARE NOT SCHEDULED FOR OFF-SITE RECYCLING CAN BE TURNED INTO THE WPAFB RECYCLING CENTER IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20. CONTACT WPAFB RECYCLING PROGRAM MANAGER AT 937-257-5060 TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO COORDINATE TURN-IN. THE CONTRACTOR SHALL SUBMIT A QUARTERLY SUMMARY REPORT TO THE GOVERNMENT CONTRACT REPRESENTATIVE IAW WPAFB SPECIFICATION SECTION 01 02 20 STATING (1) THE TONNAGE OF DIVERTED CONSTRUCTION AND DEMOLITION MATERIALS AND CORRESPONDING WEIGHT SLIPS (I.E., RECYCLED, REUSED) (2) THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS LAND-FILLED OR OTHERWISE DISPOSED OF, (3) THE DOLLAR AMOUNT EARNED BY RECYCLING, AND (4) EXPLANATION OF THE DIVERSION RATE IF LESS THAN 50%. THE QUARTERLY SUMMARY REPORTS SHALL BE RECEIVED ON APRIL 7, JULY 7, OCTOBER 7, AND JANUARY 7 COVERING THE THREE MONTHS PRIOR. FOR ADDITIONAL INFORMATION, CONTACT THE RECYCLING PM, DAVE

DALTON, AT 937-257-5060 OR DAVID.DALTON.2@US.AF.MIL

3. TURN-IN ALL MERCURY CONTAINING DEVICES, SWITCHES AND THERMOSTATS TO 88 CEG/CEIE IN ACCORDANCE

WITH WPAFB SPECIFICATION SECTION 01 02 20 FOR RECYCLING.

4. TURN-IN ALL MERCURY CONTAINING LAMPS TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB SPECIFICATION

SECTION 02 08 34.

5. TURN-IN ALL PCB CONTAINING LIGHT BALLAST TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB SPECIFICATION

SECTION 02 08 33

6. REMOVE AND DISPOSE OF ANY ASBESTOS CONTAINING MATERIAL (ACM) ASSOCIATED WITH THE WALLS, STRUCTURAL ELEMENTS AND EQUIPMENT; INCLUDING ALL WATER DAMAGED BUILDING WALL COMPONENTS IN

ACCORDANCE WITH WPAFB SPECIFICATION SECTION 02 08 10.

7. ANY LEAD CONTAINING PAINT CONTROL MEASURES SHALL BE PERFORMED IN ACCORDANCE WITH WPAFB

SPECIFICATION SECTION 02 09 00.

8. RECOVER AND RECLAIM ANY REFRIGERANT IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 02 09 10.

9. ANY USE OF RADIOACTIVE MATERIALS BY THE CONTRACTOR, INCLUDING MOISTURE DENSITY GAUGES, MUST

BE APPROVED BY THE WPAFB RADIATION SAFETY OFFICER A MINIMUM OF 30 DAYS PRIOR TO BEING BROUGHT ONTO WPAFB. THIS REQUIREMENT IS FROM WPAFBI 40-201 AND WPAFB SPECIFICATION SECTION 01 02 20.

10. NO ASBESTOS-CONTAINING MATERIAL SHALL BE INSTALLED DURING THIS PROJECT.

11. 30 DAYS PRIOR TO START OF WORK, THE CONTRACTOR SHALL TAKE A REPRESENTATIVE SAMPLE OF THE HVAC

SYSTEM WATER TO DETERMINE WHETHER IT CAN BE DRAINED DIRECTLY INTO THE SANITARY SEWER.

ANALYZE THE WATER TO DETERMINE THE TOTAL LEVEL OF EACH OF THE FOLLOWING: CADMIUM, CHROMIUM, COPPER, CYANIDE, LEAD, MERCURY, MOLYBDENUM, NICKEL, SILVER, ZINC AND SULFIDE. THE LAB PERFORMING THE ANALYSES MUST BE CERTIFIED BY OHIO EPA TO ANALYZE FOR THESE PARAMETERS. PROVIDE A COPY OF THE LAB'S REPORT TO THE CONTRACTING OFFICER, WHO WILL IN TURN FORWARD IT TO 88 CEG/CEIEA FOR A

DETERMINATION ON THE WASTEWATER DISPOSAL METHOD.

12. ALL WINDOW AND DOOR FRAME CAULKING AND GLAZING WILL BE TREATED AS CONTAINING ASBESTOS UNLESS

TESTING PROVES IT TO BE ASBESTOS FREE.

13. REMOVE ALL ABANDONED EQUIPMENT AND COMPONENTS ON (OR AT) THE WALLS, AS NOTED ON THE

DRAWINGS AND SPECIFICATIONS.

14. ANY WOOD STUD REPLACEMENT DUE TO DETERIORATION SHALL ALSO INCLUDE REATTACHMENT OF EXTERIOR

FIBERGLASS PANEL SIDING TO THE NEW WOOD STUDS.

15. EXISTING BATT INSULATION REMOVAL WILL OCCUR AFTER THE REMOVAL OF THE ASBESTOS CONTAINING

MATERIAL (ACM) WALL PANELS.

16. THE BUILDING WILL REMAIN OCCUPIED FOR THE ENTIRE DURATION OF THE CONSTRUCTION PROJECT.

CONTRACTOR WILL BE GIVEN ACCESS TO ONE WALL, PLAN NORTH, SOUTH, EAST AND WEST WITHIN THE HANGER, AT A TIME. ALL WORK MUST BE COMPLETED ON EACH WALL BEFORE APPROVAL WILL BE GIVEN TO

PROCEED WITH THE NEXT WALL.

17. FACILITY OPERATING HOURS ARE FROM 06:30AM TILL 16:30PM (04:00PM) MONDAY THRU FRIDAY, EXCLUDING FEDERAL HOLIDAYS. ALL CONSTRUCTION AREAS ARE TO BE CLEANED UP DAILY AND ALL CONSTRUCTION PERSONNEL WILL BE REQUIRED TO VACATE THE FACILITY BY 16:30PM, NO EXCEPTIONS WILL BE GRANTED.

GENERAL NOTES

AD304

AD301

MATCH LINE

IMAGE 8/AD306IMAGE 6/AD306IMAGE 10/AD306

IMAGE 1/AD306

IMAGE 9/AD306

IMAGE 17/AD305

IMAGE 6/AD305

(INSIDE INTERIOR

BLDG.)

IMAGE 20/AD305

AD302

SEE 1/AD302 AND

IMAGE 11/AD306

FOR KEYNOTES

ABOVE

ABOVE

016023

024023

012 003

004 004

006005002

ABOVE

EXISTING WINDOW AND GLASS BLOCK TO BE

REMOVED - WGC THAT CONTAINS ASBESTOS

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING LOUVER TO BE REMOVED

EXISTING ACM PANELS AND INSULATION

TO BE REMOVED AND DISPOSED

EXISTING DUCTWORK TO BE REMOVED

EXISTING WALLS AND COLUMNS TO REMAIN

EXISTING OVERHEAD DOOR TO BE REMOVED

EXISTING ACM PANELS, INSULATION AND

WOOD FRAME TO BE REMOVED AND DISPOSED

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

HIGH BAY PARTIAL FLOOR PLAN - DEMO AD101A

20-JAN-2016DL

DTBB

N SCALE : 3/32" = 1'-0"

HIGH BAY PARTIAL FLOOR PLAN - DEMO (PLAN CUT 10'-0" A.F.F.)

SYMBOLS LEGEND KEY PLAN

012 EXISTING FRAME ON THE WALL TO BE REMOVED.

016 EXISTING JIB CRANE TO BE REMOVED.

020 EXISTING METAL TRACK TO BE REMOVED.

021 EXISTING INTERIOR BUILDING AND ASSOCIATED WALL MOUNTED

EQUIPMENT TO BE REMOVED BY OWNER PRIOR TO START THIS

CONTRACT.

022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.

023 EXISTING ALUMINUM SCREEN AND ABANDONED PIPES TO BE

REMOVED.

024 EXISTING EMERGENCY STOP LIGHTS AND SIGNS TO BE REMOVED,

INCLUDING CONDUIT AND CIRCUIT BACK TO EXISTING PANEL.

001 EXISTING DUCTWORK TO BE REMOVED.

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND

(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE

SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE

PROPERLY DECONTAMINATED.

003 EXISTING CLERESTORY GLASS BLOCK TO BE REMOVED.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED.

005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO

REMAIN.

010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE

REMOVED.

AD303

AD304

MATCH LINE

IMAGE 14/AD305

IMAGE 1/AD305,

IMAGE 2/AD305,

IMAGE 7/AD305

IMAGE 3/AD305,

IMAGE 4/AD305

IMAGE 5/AD305

IMAGE 16/AD305

IMAGE 9/AD305,

IMAGE 11//AD305

IMAGE 15/AD305

IMAGE 8/AD305

IMAGE 7/AD306

AD302

SEE 1/AD302 AND

IMAGE 11/AD306

FOR KEYNOTES

ABOVEABOVE

022004

006005

006005002

004 010 014

018 019

004 014 018 019

004 010

025 026

010011010

EXISTING WINDOW AND GLASS BLOCK TO BE

REMOVED - WGC THAT CONTAINS ASBESTOS

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING LOUVER TO BE REMOVED

EXISTING ACM PANELS AND INSULATION

TO BE REMOVED AND DISPOSED

EXISTING DUCTWORK TO BE REMOVED

EXISTING WALLS AND COLUMNS TO REMAIN

EXISTING OVERHEAD DOOR TO BE REMOVED

EXISTING ACM PANELS, INSULATION AND

WOOD FRAME TO BE REMOVED AND DISPOSED

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

HIGH BAY PARTIAL FLOOR PLAN - DEMO AD101B

20-JAN-2016DL

DTBB

N SCALE : 3/32" = 1'-0"

HIGH BAY PARTIAL FLOOR PLAN - DEMO (PLAN CUT 10'-0" A.F.F.)

SYMBOLS LEGEND KEY PLAN

010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE

REMOVED.

011 EXISTING METAL AND WOOD SCAFFOLDING TO BE REMOVED.

012 EXISTING FRAME ON THE WALL TO BE REMOVED.

013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC

SHALL BE ABATED PER BASE SPECIFICATIONS.

014 EXISTING ABANDONED METAL DUCT TO BE REMOVED.

018 CONTRACTOR TO PROTECT EXISTING CONDUIT AND EQUIPMENT TO

REMAIN ON THE WALL.

019 EXISTING METAL PANEL AND WALL COMPONENTS TO BE REMOVED.

022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.

025 EXISTING GLASS BLOCK TO REMAIN.

026 EXISTING GLASS BLOCK TO REMAIN BEHIND EXISTING DUCTWORK TO

BE REMOVED.

001 EXISTING DUCTWORK TO BE REMOVED.

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND

(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE

SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE

PROPERLY DECONTAMINATED.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED.

005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO

REMAIN.

008 EXISTING OVERHEAD DOOR, FRAME, AND COUNTER WEIGHTS TO BE

REMOVED. PATCH AND FILL EXISTING BOLTED CONNECTION HOLES

WITH EPOXY GROUNT, PAINT.

Level 1 0"

Low Roof 64' - 0"

Mid Roof 101' - 8"

High Roof 131' - 0"

AD304

004 015

002 002 002 002

002 002 002 002

002002 002

004 004

003 003

IMAGE 6/AD306

IMAGE 10/AD306

IMAGE 8/AD306

AD302

002002002002002

IMAGE 11/AD306

IMAGE 11/AD306

IMAGE 11/AD306

015 015

007 001

013013

BEHIND SCREEN

IMAGE 2/AD306

EXISTING WINDOW AND GLASS BLOCK TO BE

REMOVED - WGC THAT CONTAINS ASBESTOS

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING LOUVER TO BE REMOVED

EXISTING ACM PANELS AND INSULATION

TO BE REMOVED AND DISPOSED

EXISTING DUCTWORK TO BE REMOVED

EXISTING WALLS AND COLUMNS TO REMAIN

EXISTING OVERHEAD DOOR TO BE REMOVED

EXISTING ACM PANELS, INSULATION AND

WOOD FRAME TO BE REMOVED AND DISPOSED

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR WEST WALL ELEVATION - DEMO AD301

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR WEST WALL ELEVATION - DEMO

SYMBOLS LEGEND

015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,

INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.

EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED

TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10

SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED

GASKET @ MAX. FASTENER SPACING OF 16” O.C.

016 EXISTING JIB CRANE TO BE REMOVED.

021 EXISTING INTERIOR BUILDING AND ASSOCIATED WALL MOUNTED

EQUIPMENT TO BE REMOVED BY OWNER PRIOR TO START THIS

CONTRACT.

023 EXISTING ALUMINUM SCREEN AND ABANDONED PIPES TO BE

REMOVED.

024 EXISTING EMERGENCY STOP LIGHTS AND SIGNS TO BE REMOVED,

INCLUDING CONDUIT AND CIRCUIT BACK TO EXISTING PANEL.

029 EXISTING MEZZANINE HAS ALREADY BEEN REMOVED BY OWNER.

001 EXISTING DUCTWORK TO BE REMOVED.

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND

(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE

SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE

PROPERLY DECONTAMINATED.

003 EXISTING CLERESTORY GLASS BLOCK TO BE REMOVED.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED.

005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO

REMAIN.

013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING WINDOW AND GLASS BLOCK TO BE

REMOVED - WGC THAT CONTAINS ASBESTOS

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING LOUVER TO BE REMOVED

EXISTING ACM PANELS AND INSULATION

TO BE REMOVED AND DISPOSED

EXISTING DUCTWORK TO BE REMOVED

EXISTING WALLS AND COLUMNS TO REMAIN

EXISTING OVERHEAD DOOR TO BE REMOVED

EXISTING ACM PANELS, INSULATION AND

WOOD FRAME TO BE REMOVED AND DISPOSED

Level 1 0"

Low Roof 64' - 0"

Mid Roof 101' - 8"

High Roof 131' - 0"

AD303

AD301

001 001 001

004 004 004

004 004

004 004 004

009 002 009 009 009 009002 002 002

004 004 004 004004 004004 004 004 004

004004

IMAGE 17/AD305

IMAGE 14/AD305,

IMAGE 20/AD305

IMAGE 7/AD305 IMAGE 5/AD305

IMAGE 11/AD306

IMAGE 11/AD306

015 017017017017 017 017 017 017 017

017 015

018 019 013013

IMAGE 19/AD305

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR NORTH WALL ELEVATION - DEMO AD302

20-JAN-2016DL

DTBB

SYMBOLS LEGEND

SCALE : 3/32" = 1'-0"1 INTERIOR NORTH WALL ELEVATION - DEMO

021 EXISTING INTERIOR BUILDING AND ASSOCIATED WALL MOUNTED

EQUIPMENT TO BE REMOVED BY OWNER PRIOR TO START THIS

CONTRACT.

022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.

027 EXISTING NORTH WALL DOORS TO REMAIN.

028 EXISTING STEAM GENERATION UNIT TO BE REMOVED.

014 EXISTING ABANDONED METAL DUCT TO BE REMOVED.

015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,

INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.

EXISTING EXTERIOR METAL PANELS WILL NEED TO BE

RE-ATTACHED TO THE REPLACED WOOD STUD FRAMING WITH MIN.

1-1/2” #10 SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH

INSULATED GASKET @ MAX. FASTENER SPACING OF 16” O.C.

017 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED. INSPECT EXISTING

WOOD FRAME FOR WATER DAMAGE AND REPLACE AS REQUIRED.

EXISTING EXTERIOR METAL PANELS WILL NEED TO BE

RE-ATTACHED TO THE REPLACED WOOD STUD FRAMING WITH MIN.

1-1/2” #10 SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH

INSULATED GASKET @ MAX. FASTENER SPACING OF 16” O.C.

018 CONTRACTOR TO PROTECT EXISTING CONDUIT AND EQUIPMENT TO

REMAIN ON THE WALL.

019 EXISTING METAL PANEL AND WALL COMPONENTS TO BE REMOVED.

020 EXISTING METAL TRACK TO BE REMOVED.

001 EXISTING DUCTWORK TO BE REMOVED.

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING

COMPOUND (WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED

PER BASE SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS

SHOULD BE PROPERLY DECONTAMINATED.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED.

005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

009 EXISTING LOUVER TO BE REMOVED.

010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO

BE REMOVED.

013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC

SHALL BE ABATED PER BASE SPECIFICATIONS.

Low Roof 64' - 0"

Mid Roof 101' - 8"

High Roof 131' - 0"

AD304

002004 002 002 002 002002 002 002 002 002

002002002002

015 004

002 002

AD302

002002002002002

IMAGE 11/AD306

IMAGE 11/AD306

IMAGE 11/AD306

015 015

004002

EXISTING WINDOW AND GLASS BLOCK TO BE

REMOVED - WGC THAT CONTAINS ASBESTOS

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING LOUVER TO BE REMOVED

EXISTING ACM PANELS AND INSULATION

TO BE REMOVED AND DISPOSED

EXISTING DUCTWORK TO BE REMOVED

EXISTING WALLS AND COLUMNS TO REMAIN

EXISTING OVERHEAD DOOR TO BE REMOVED

EXISTING ACM PANELS, INSULATION AND

WOOD FRAME TO BE REMOVED AND DISPOSED

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR EAST WALL ELEVATION - DEMO AD303

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR EAST WALL ELEVATION - DEMO

SYMBOLS LEGEND

012 EXISTING FRAME ON THE WALL TO BE REMOVED.

015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,

INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.

EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED

TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10

SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED

GASKET @ MAX. FASTENER SPACING OF 16” O.C.

025 EXISTING GLASS BLOCK TO REMAIN.

026 EXISTING GLASS BLOCK TO REMAIN BEHIND EXISTING DUCTWORK TO

BE REMOVED.

001 EXISTING DUCTWORK TO BE REMOVED.

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND

(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE

SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE

PROPERLY DECONTAMINATED.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED.

005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO

REMAIN.

007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO

REMAIN.

008 EXISTING OVERHEAD DOOR, FRAME, AND COUNTER WEIGHTS TO BE

REMOVED. PATCH AND FILL EXISTING BOLTED CONNECTION HOLES

WITH EPOXY GROUNT, PAINT.

Low Roof 64' - 0"

Mid Roof 101' - 8"

High Roof 131' - 0"

AD303

AD301

004004 004 004 004004 004 004 004 004

007 007 007 007 007

015017017017017017017017017017

EXISTING WINDOW AND GLASS BLOCK TO BE

REMOVED - WGC THAT CONTAINS ASBESTOS

SHALL BE ABATED PER BASE SPECIFICATIONS.

EXISTING LOUVER TO BE REMOVED

EXISTING ACM PANELS AND INSULATION

TO BE REMOVED AND DISPOSED

EXISTING DUCTWORK TO BE REMOVED

EXISTING WALLS AND COLUMNS TO REMAIN

EXISTING OVERHEAD DOOR TO BE REMOVED

EXISTING ACM PANELS, INSULATION AND

WOOD FRAME TO BE REMOVED AND DISPOSED

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR SOUTH WALL ELEVATION - DEMO AD304

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR SOUTH WALL ELEVATION - DEMO

SYMBOLS LEGEND

017 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED. INSPECT EXISTING

WOOD FRAME FOR WATER DAMAGE AND REPLACE AS REQUIRED.

EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED

TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10

SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED

GASKET @ MAX. FASTENER SPACING OF 16” O.C.

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND

(WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE

SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE

PROPERLY DECONTAMINATED.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND

INSULATION TO BE REMOVED AND DISPOSED.

007 EXISTING SOUTH WALL TALL FRAMED GLASS HANGER DOORS TO

REMAIN.

009 EXISTING LOUVER TO BE REMOVED.

015 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS,

INSULATION AND WOOD FRAME TO BE REMOVED AND DISPOSED.

EXISTING EXTERIOR METAL PANELS WILL NEED TO BE RE-ATTACHED

TO THE REPLACED WOOD STUD FRAMING WITH MIN. 1-1/2” #10

SELF-TAPPING STAINLESS STEEL HEX SCREWS WITH INSULATED

GASKET @ MAX. FASTENER SPACING OF 16” O.C.

004 EXISTING ASBESTOS CONTAINING MATERIALS (ACM) PANELS AND INSULATION TO BE REMOVED AND DISPOSED.

010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE REMOVED.

011 EXISTING METAL AND WOOD SCAFFOLDING TO BE REMOVED.

012 EXISTING FRAME ON THE WALL TO BE REMOVED.

014 EXISTING ABANDONED METAL DUCT TO BE REMOVED.

018 CONTRACTOR TO PROTECT EXISTING CONDUIT AND EQUIPMENT TO REMAIN ON THE WALL.

019 EXISTING METAL PANEL AND WALL COMPONENTS TO BE REMOVED.

020 EXISTING METAL TRACK TO BE REMOVED.

022 EXISTING SLIDING DOOR TRACK EXTENSIONS TO BE REMOVED.

028 EXISTING STEAM GENERATION UNIT TO BE REMOVED.

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

PHOTOS AD305

20-JAN-2016DL

DTBB

IMAGE 1/AD305 IMAGE 3/AD305 IMAGE 5/AD305 IMAGE 7/AD305 IMAGE 9/AD305

IMAGE 11/AD305 IMAGE 15/AD305

IMAGE 16/AD305 IMAGE 12/AD305

IMAGE 17/AD305

IMAGE 2/AD305 IMAGE 4/AD305 IMAGE 6/AD305 IMAGE 8/AD305

019 019

IMAGE 14/AD305

020 004

IMAGE 20/AD305

IMAGE 19/AD305

IMAGE 17/AD305

IMAGE 14/AD305

020 004

002 EXISTING WINDOW TO BE REMOVED - WINDOW GLAZING COMPOUND (WGC) THAT CONTAINS ASBESTOS SHALL BE ABATED PER BASE SPECIFICATIONS. WGC DEBRIS BENEATH WINDOWS SHOULD BE PROPERLY DECONTAMINATED.

005 EXISTING WIRE REINFORCED CORREGATED GLASS PANELS TO REMAIN.

006 EXISTING EXTERIOR WALL METAL PANEL ON METAL STUDS OVER EXISTING WIRE REINFORCED CORREGATED GLASS

PANELS TO REMAIN.

010 EXISTING ABANDONED ELECTRICAL EQUIPMENT AND CONDUIT TO BE REMOVED.

012 EXISTING FRAME ON THE WALL TO BE REMOVED.

013 EXISTING ABANDONED STEAM PIPE TO BE REMOVED - ANY AMC SHALL BE ABATED PER BASE SPECIFICATIONS.

016 EXISTING JIB CRANE TO BE REMOVED.

023 EXISTING ALUMINUM SCREEN AND ABANDONED PIPES TO BE REMOVED.

024 EXISTING EMERGENCY STOP LIGHTS AND SIGNS TO BE REMOVED, INCLUDING CONDUIT AND CIRCUIT BACK TO

EXISTING PANEL.

029 EXISTING MEZZANINE HAS ALREADY BEEN REMOVED BY OWNER (SEE AD301).

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

PHOTOS AD306

20-JAN-2016DL

DTBB

IMAGE 7/AD306

IMAGE 1/AD306 IMAGE 6/AD306

IMAGE 8/AD306

IMAGE 10/AD306

IMAGE 9/AD306

IMAGE 11/AD306

IMAGE 2/AD306

A-304

A-301

A-302

105 105105

MATCH LINE

105105

SEE 1/A302 FOR

KEYNOTES

SEE 1/A301 FOR

KEYNOTES

A-402

TYP.

103103

106102

NEW WINDOW SYSTEM - AS SPECIFIED

NEW GLASS BLOCK - AS SPECIFIED

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - ELEVATION

EXISTING WALLS AND COLUMNS TO

REMAIN

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - SECTION

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

HIGH BAY PARTIAL FLOOR PLAN A-101A

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"

HIGH BAY PARTIAL FLOOR PLANN

(PLAN CUT 10'-0" A.F.F.)

SYMBOLS LEGEND KEY PLAN

106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"

OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.

THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR

METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL

IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON

THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE

SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.

101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT

CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR

REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION

BATT INSULATION IN WALL CAVITY (KRAFT FACE).

102 NEW WINDOW SYSTEM - AS SPECIFIED.

103 NEW GLASS BLOCK - AS SPECIFIED.

104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS

HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.

105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND

CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT

THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,

WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF

TRUSSES, METAL DECK AND CRANES. PAINT COLOR "PNT-3" - SEE

SPECS.

A-304

A-303

A-302

105 105

MATCH LINE

105 105

105 105

SEE 1/A302 FOR

KEYNOTES

A-402

TYP.

102 106

NEW WINDOW SYSTEM - AS SPECIFIED

NEW GLASS BLOCK - AS SPECIFIED

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - ELEVATION

EXISTING WALLS AND COLUMNS TO

REMAIN

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - SECTION

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

HIGH BAY PARTIAL FLOOR PLAN A-101B

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"

HIGH BAY PARTIAL FLOOR PLANN

(PLAN CUT 10'-0" A.F.F.)

SYMBOLS LEGEND KEY PLAN

106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"

OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.

THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR

METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL

IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON

THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE

SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.

101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT

CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR

REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION

BATT INSULATION IN WALL CAVITY (KRAFT FACE).

102 NEW WINDOW SYSTEM - AS SPECIFIED.

104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS

HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.

105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND

CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT

THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,

WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF

Low Roof 64' - 0"

A-304

Mid Roof 101' - 8"

High Roof 131' - 0"

A-302

101 101

102 102

101101

A-402

A-402

W1

W2A

W1

W6

W2B

W2A

W2A

W2A

W2B

W2B

W2B

W4

W3W3

W6

W6

W6

101101

NEW WINDOW SYSTEM - AS SPECIFIED

NEW GLASS BLOCK - AS SPECIFIED

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - ELEVATION

EXISTING WALLS AND COLUMNS TO

REMAIN

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - SECTION

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR WEST WALL ELEVATION A-301

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR WEST WALL ELEVATION

SYMBOLS LEGEND

106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"

OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.

THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR

METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL

IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON

THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE

SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.

108 INFILL EXISTING CMU WALL OPENINGS, WHERE DUCTWORK IS

REMOVED. MATCH EXISTING CAVITY WALL CONSTRUCTION, WHERE

OCCURS.

101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT

CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR

REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION

BATT INSULATION IN WALL CAVITY (KRAFT FACE).

102 NEW WINDOW SYSTEM - AS SPECIFIED.

103 NEW GLASS BLOCK - AS SPECIFIED.

104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS

HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.

105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND

CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT

THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,

WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF

Low Roof 64' - 0"

A-301

Mid Roof 101' - 8"

High Roof 131' - 0"

A-303

101101 101 101 101 101 101 101 101 101

101101 101 101

101 101

101 101 101

101101 101 101 101 101 101 101 101 101

102 102 102 102 102 102 102 102 102

W3 W3 W3 W3 W3 W3 W3 W3 W3 W3

W4

IMAGE 11/AD306

NEW WINDOW SYSTEM - AS SPECIFIED

NEW GLASS BLOCK - AS SPECIFIED

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - ELEVATION

EXISTING WALLS AND COLUMNS TO

REMAIN

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - SECTION

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR NORTH WALL ELEVATION A-302

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR NORTH WALL ELEVATION

SYMBOLS LEGEND

101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT

CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR

REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION

BATT INSULATION IN WALL CAVITY (KRAFT FACE).

102 NEW WINDOW SYSTEM - AS SPECIFIED.

107 LINE OF NEW EXTERIOR WALL METAL PANEL ON METAL STUDS AND

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS BEYOND.

109 PRIME AND PAINT EXISTING NORTH WALL DOORS TO REMAIN. PAINT

COLOR "PNT-2" - SEE SPECS.

Low Roof 64' - 0"

A-304

Mid Roof 101' - 8"

High Roof 131' - 0"

A-302

102 102

A-402

A-402

W4

W1

102102

W2A W1

W2B

102 102 102

102102102

W3W3

W2A

W2B

W2A

W2B

W2A

W2B

101101

NEW WINDOW SYSTEM - AS SPECIFIED

NEW GLASS BLOCK - AS SPECIFIED

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - ELEVATION

EXISTING WALLS AND COLUMNS TO

REMAIN

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - SECTION

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR EAST WALL ELEVATION A-303

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR EAST WALL ELEVATION

SYMBOLS LEGEND

106 NEW EXTERIOR WALL METAL PANEL ON METAL STUDS OVER

EXISTING WIRE REINFORCED CORREGATED GLASS PANELS, LAP 4"

OVER EXISTING WALL METAL PANEL, MATCH PROFILE AND COLOR.

THIS NOTE AND REFERENCES TO IT APPLY ONLY TO THE EXTERIOR

METAL PANELS CALLED FOR IN WALL DETAIL 1/A-402. THIS MATERIAL

IS LOCATED ONLY ABOVE THE ONE STORY FLAT ROOF ADDITION ON

THE NORTH SIDE OF THE BUILDING. THE NEW METAL PANEL PROFILE

SHALL MATCH THE EXISTING PANELS IN THAT LOCATION ONLY.

108 INFILL EXISTING CMU WALL OPENINGS, WHERE DUCTWORK IS

REMOVED. MATCH EXISTING CAVITY WALL CONSTRUCTION, WHERE

OCCURS.

101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT

CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR

REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION

BATT INSULATION IN WALL CAVITY (KRAFT FACE).

102 NEW WINDOW SYSTEM - AS SPECIFIED.

104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS

HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.

105 PRIME AND PAINT ALL EXPOSED WALL SURFACES, STRUCTURE, AND

CONDUITS UNLESS NOTED OTHERWISE. CONTRACTOR NOT TO PAINT

THE FOLLOWING ITEMS: SAFETY YELLOW HANDRAILS, LADDERS,

WALL MOUNTED CONDUIT AND PIPING THAT IS NOT PAINTED, ROOF

Low Roof 64' - 0"

A-301

Mid Roof 101' - 8"

High Roof 131' - 0"

A-303

101 101 101 101 101 101 101 101 101

104 104 104 104 104

101101 101 101 101 101 101 101 101 101

W3

W3

W3

W3

W3

W3

W3

W3

W3

W3

NEW WINDOW SYSTEM - AS SPECIFIED

NEW GLASS BLOCK - AS SPECIFIED

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - ELEVATION

EXISTING WALLS AND COLUMNS TO

REMAIN

NEW INTERIOR WALL METAL PANEL

OVER METAL STUDS - SECTION

SHEET KEYNOTES

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

INTERIOR SOUTH WALL ELEVATION A-304

20-JAN-2016DL

DTBB

SCALE : 3/32" = 1'-0"1 INTERIOR SOUTH WALL ELEVATION

SYMBOLS LEGEND

101 NEW INTERIOR PERFORATED METAL PANEL OVER 7/8" METAL HAT

CHANNEL FRAMING @ 24" O.C. (HORIZONTAL) OVER EXISTING OR

REPLACED WOOD STUDS, INSTALL MIN. R-11 SOUND ATTENUATION

BATT INSULATION IN WALL CAVITY (KRAFT FACE).

102 NEW WINDOW SYSTEM - AS SPECIFIED.

104 PRIME AND PAINT EXISTING SOUTH WALL TALL FRAMED GLASS

HANGER DOORS. PAINT COLOR "PNT-1" - SEE SPECS.

4"

FI

E

LD

V

ER

IF

Y

10 EQ. PANELS = 50' - 0" - FIELD VERIFY

A-402

A-402

TYP. PANEL

5' - 0"

EQ. EQ.

E Q

E

Q

E Q

E

Q

E Q

GL-1 AT WEST WALL

GL-2 AT EAST WALL

4"

FI

E

LD

V

ER

IF

Y

2 EQ. PANELS

10' - 0" FIELD VERIFY

A-402

A-402

A-402

AT W2B AT W2A

TYP. PANEL

5' - 0"

EQ. EQ.

E Q

E

Q

E Q

E

Q

E Q

N E

W R

.O

4" -F

IE

LD

V E

R

IF

Y

3 EQ. PANELS

15' - 0" FIELD VERIFY

A-402

A-402

TYP. PANEL

5' - 0"

EQ. EQ.

E Q

E

Q

E Q

E

Q

E Q

GL-1

8' -1

1"

14' - 10"

A-402

A-402

A-402

N E

W R

.O

4" -F

IE

LD

V E

R

IF

Y

60 EQ. PANELS = 141'-0" - FIELD VERIFY

A-402

A-402

TYP.

1 PANEL

GL-1

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

WINDOW TYPES A-401

20-JAN-2016DL

DTBB

SCALE : 1/4" = 1'-0"

W1

SCALE : 1/4" = 1'-0"

W2A & W2B

SCALE : 1/4" = 1'-0"

W3

SCALE : 1/4" = 1'-0"

W6

SCALE : 1/4" = 1'-0"

W4

REFERENCES:

UFC 3-301-01, 1 JUNE 2013 STRUCTURAL ENGINEERING

UFC 4-010-01, 9 FEBRUARY 2012 CHANGE 1, 1 OCTOBER 2013 DOD MINIMUM ANTITERRORISM

STANDARDS FOR BUILDINGS

ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES

WIND DESIGN PARAMETERS

a. BASIC WIND SPEED = 115

b. RISK CATEGORY = II

c. WIND EXPOSURE = C

d. COMPONENTS AND CLADDING – WALLS

AREA (SF) INTERIOR ZONE EDGE ZONE

10 39.2 PSF 71.8 PSF

100 35.5 PSF 57.3 PSF

200 33.7 PSF 50.1 PSF

500 31.9 PSF 42.8 PSF

ANTI-TERRIORISM / FORCE PROTECTION:

a. BUILDING CATEGORY = PRIMARY GATHERING BUILDING (LOW LEVEL OF PROTECTION)

b. STANDOFF DISTANCE = 61 FT. HORIZONTAL DIMENSION; 98 FT. ALONG 51 DEGREE INCIDENCE

ANGLE MEASURED FROM HORIZONTAL

c. APPLICABLE CHARGE WEIGHT = EXPLOSIVE WEIGHT II

STRUCTURAL CODE SUMMARY:

N WALL

HIGH WINDOW: 55'-4 1/4"

E X

IS

TI

N G

R .O

3/ 8"

-F

IE

LD

V

ER

IF

Y

N E

W R

.O

4"

PERFORATED METAL

PANEL

NEW BATT INSULATION,

INSTALLED AS SPECIFIED

INTERIOR PRE-

FINISHED METAL

TRIM

NEW WINDOW

AS SPECIFIED

EXISTING EXTERIOR

WALL TO REMAIN

SEALANT FULL

PERIMETER - TYP.

CONT. 3x2x5/16 STEEL

ANGLE WELD TO

EXISTING FRAME - TYP.

7/8" METAL FURRING

CHANNEL @ 24" O.C.

SEALANT FULL

PERIMETER - TYP.

N WALL LOW WINDOW: 34'-1 1/2"

PERFORATED METAL

PANEL

NEW BATT INSULATION,

INSTALLED AS SPECIFIED

EXISTING EXTERIOR

WALL TO REMAIN

EXISTING EXTERIOR

WALL TO REMAIN

EXISTING WALL METAL

PANEL ON METAL

STUDS TO REMAIN

EXISTING ROOF

NEW EXTERIOR WALL

METAL PANEL ON METAL

STUDS, LAP 4" OVER

EXISTING WALL METAL

PANEL, MATCH PROFILE

7/8" METAL FURRING

CHANNEL @ 24" O.C.

EXISTING METAL

FLASHING TO BE

REMOVED

4"

MI

N.

NEW PRE-FINISHED

METAL FLASHING,

LAP 4" MIN.

EXISTING WIRE REINFORCED

CORREGATED GLASS

PANELS TO REMAIN

4"

MI

N.

4"

MI

N.

NEW 2X WOOD STUDS

INFILL @ 16" O.C. BEHIND

EXISTING WINDOW

ALIGNED

ALIGNED

PERFORATED METAL PANEL

7/8" METAL FURRING CHANNEL @ 24" O.C.

INTERIOR PRE-FINISHED METAL TRIM

NEW WINDOW AS SPECIFIED

NEW BATT INSULATION, INSTALLED AS SPECIFIEDEXISTING EXTERIOR

WALL TO REMAIN

CONT. 3x2x5/16 STEEL

ANGLE WELD TO

EXISTING FRAME - TYP.

SEALANT FULL

PERIMETER - TYP.

PERFORATED METAL PANEL

INTERIOR PRE-FINISHED

METAL TRIM

NEW BATT INSULATION, INSTALLED AS SPECIFIEDEXISTING EXTERIOR

WALL TO REMAIN

EXISTING EXTERIOR

WALL TO REMAIN

E X

IS

TI

N G

R .O

'-7 3/

8" -F

IE

LD

V

ER

IF

Y

N E

W R

.O

'-4

SEALANT FULL

PERIMETER - TYP.

CONT. 3x2x5/16 STEEL

ANGLE WELD TO

EXISTING FRAME - TYP.

NEW WINDOW

AS SPECIFIED

7/8" METAL FURRING

CHANNEL @ 32" O.C.

SEALANT FULL

PERIMETER - TYP.

NEW METAL

FLASHING

METAL PANEL ANCHOR AS REQUIRED

HORIZONTAL JOINT

REINFORCING

GLASS BLOCK UNIT

MORTAR BED

ASPHALT EMULSION

EXISTING WALL

METAL PANEL ANCHOR

AS REQUIRED

HORIZONTAL JOINT

REINFORCINGGLASS BLOCK UNIT

MORTAR BED

BACKER ROD AND

SEALANT, ON BOTH SIDES

OF GLASS BLOCK UNIT

EXISTING WALL

ALUMINUM ANGLE,

ON BOTH SIDES OF

GLASS BLOCK UNIT EXPANSION STRIP

TREATED WOOD BLOCKING

METAL PANEL

ANCHORS - BEND WITH

EXPANSION JOINT

MORTAR BED

HORIZONTAL JOINT

REINFORCING AS

REQUIRED FOR EACH

INSTALLATION

GLASS

BLOCK UNIT

EXPANSION

STRIP

HORIZONTAL JOINT

REINFORCING

GLASS BLOCK UNIT

MORTAR BED

BACKER ROD AND

SEALANT, ON BOTH SIDES

OF GLASS BLOCK UNIT

EXISTING BEAM OR ROOF

ALUMINUM ANGLE,

ON BOTH SIDES OF

GLASS BLOCK UNIT TREATED WOOD BLOCKING

PERFORATED METAL PANEL

7/8" METAL FURRING CHANNEL @ 24" O.C.

INTERIOR PRE-FINISHED

METAL TRIM

NEW BATT INSULATION,

INSTALLED AS SPECIFIED

EXISTING EXTERIOR

WALL TO REMAIN

WOOD BLOCKING

AS REQUIRED

EXISTING STEEL

COLUMN TO REMAIN

C

IVI

L E N G I N E

E R

88TH ABWWPAFB

WRIGHT-PATTERSON AIR FORCE BASE

COORDINATOR DESIGN CHIEF ENGINEERING CHIEF

DATE NO. REVISION BY NO. REVISION BY

DRAWNDESIGNED CHECKED DATE

OF

US AF

DATE

REMOVE ASBESTOS HIGH BAY, FACILITY 20065

PROJ. NUMBER: ZHTV051863

DETAILS A-402

20-JAN-2016DL

DTBB

SCALE : 1 1/2" = 1'-0"2 WINDOW DETAIL - HEAD & SILL

SCALE : 1 1/2" = 1'-0"1 WALL DETAIL

SCALE : 1 1/2" = 1'-0"5 WINDOW DETAIL - JAMB

SCALE : 1 1/2" = 1'-0"3 WINDOW DETAIL - HEAD & SILL

SCALE : 1 1/2" = 1'-0"7 GLASS BLOCK DETAIL - SILL

NTS6 GLASS BLOCK DETAIL - JAMB

NTS

GLASS BLOCK DETAIL

SCALE : 1 1/2" = 1'-0"8 GLASS BLOCK DETAIL - HEAD

SCALE : 1 1/2" = 1'-0"4 PLAN DETAIL

G-001
AD101A
AD101B
AD301
AD302
AD303
AD304
AD305
AD306
A-101A
A-101B
A-301
A-302
A-303
A-304
A-401
A-402
A-402