FA8532-15-Q-90161
PURGING UNIT, AIR, LIQUID OXYGEN STORAGE TANKS
RFQ QUESTION AND ANSWER
28 AUG 2015
Follow On Question to 27 Aug 2018 Q&A Posting:
I downloaded the complete document and have reviewed the 335 pages. I do not see an Accelerated Loads test callout. Can you specifically provide the paragraph in the document where the acceleration test protocol is defined and the criteria to be meet?
Answer:
Para. 5.3.5.1 - Acceleration, shock, and vibration requirements.