Q A_25AUG15.docx

DOCX document 15 KB Posted

Attached to
PURGING UNIT Federal contract opportunity
Solicitation number
FA8532-15-Q-90161
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Robins Air Force Base

About this file

Q A 25 AUG 15

View the file

Other files for this federal contract opportunity

Other files attached to PURGING UNIT, newest first.
File Type Posted
QA_28AUG15.docx DOCX document
Q A_27AUG15.docx DOCX document
MIL-P-27456C.pdf PDF
MIL-P-27456C_NOT_1.pdf PDF
Q A_7_AUG_15.docx DOCX document
MIL-P-27456C_NOT_2.pdf PDF
FA853215Q90161______0002.pdf PDF
AMEND_0001_FA8532-15-Q-90161.pdf PDF
ATTACHMENTS_FOR_FA8532-15-Q-90161.pdf PDF
C001_-_TECH_MANUALS.pdf PDF
FA853215Q90161.pdf PDF
FA8532-15-Q-90161A3655-00-429-2896.zip ZIP file
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA8532-15-Q-90161

PURGING UNIT, AIR, LIQUID OXYGEN STORAGE TANKS

RFQ QUESTION AND ANSWER

25 AUG 2015

Question:

Electrical Components - Is it permissible to consider program logic control as a means to operate the equipment. The current design has the temperature controllers inside the electrical control box. If there was a requirement to increase or decrease the temperature set point, the unit had to be turned off to open the door. Having the ability to adjust the temperature on the outside of the box makes more sense.

Answer:

The government does not disagree with using a PLC, although that exceeds the requirement.

Question:

Venting Assembly - I did not see any reference to a vent valve assembly requirement to vent excess pressure if purging LOX carts with reduced piping diameter less than 1-inch to avoid over amperage of the electrical motor. Is there a requirement for this accessory assembly?

Answer:

There is not a requirement for a venting assembly on the purging unit.

Question:

4.6.11 Mobility - I have been informed by a environmental testing lab that the MIL-M-8090 may have been cancelled in 1997. Is there an updated document or another MIL-M to reference so I can get quote to conduct the required test?

Answer:

MIL-M-8090 was cancelled and replaced by SAE-AS8090.