QALIF15CRCdual.pdf
PDF 105 KB Posted
- Attached to
- F15 Canopy Remover Federal contract opportunity
- Solicitation number
- FA8213-20-R-3030
About this file
This document contains a quality assurance letter of instruction and federal contract opportunity solicitation. The quality assurance letter outlines inspection requirements for canopy remover cartridges to be used in F-15 aircraft ejection systems. Inspection points include verification of explosive weight, leak testing, radiographic film quality, lot acceptance testing sample selection and procedures, preparation for shipment, ammunition data card review, and packaging documentation. The related federal contract opportunity solicitation seeks bids to supply F-15 canopy removers and cartridges to Hill Air Force Base by December 31, 2021. Line items include the canopy removers, cartridges, and data requirements. Quantity ranges from 4 to 67 units per line item. Electronic bidding procedures will be used.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA821320R3030_______0001.pdf | ||
| SOWSPI.pdf | ||
| REPSHIP11Mar14.doc | DOC document | |
| CADPADItemMarkingInstruction.pdf | ||
| JQR012029195.pdf | ||
| 1750009QALI.pdf | ||
| JQR003616048.pdf | ||
| CDRLs.pdf | ||
| EDL.pdf | ||
| ADCSOWJan2018.doc | DOC document | |
| F001382871.pdf | ||
| JQR003493938.pdf | ||
| ItemDescription.pdf | ||
| FA821320R3030.pdf | ||
| 1750009airspec.doc | DOC document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contractor Name CAGE code
DCMA QAR Reviewer
Date Review Completed
Date Issued to Contractor
PR No. FD2020-
Date Contract Awarded
Final Delivery Date (FDD)
Program Name
DODIC
Part Number
The contractor is required to impose the listed below DCMA Inspection Points into the appropriate Work Orders.
All Work Orders pertaining to CRITICAL FLIGHT ITEMS must be identified on folders.
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Witness - W: GSI required to attend, may reduce level of effort after 50% of production lots found acceptable
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Monitor - R: Will monitor testing, may reduce to verification
Notify - N: By phone or daily schedule 24( R ) - 48 ( NR ) hours in advance
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Prepared by:
Date
Concurrence Signature by QAR/DCMA:
QAR/DCMA
THIS PLANNING SHEET WILL BE UPDATED IF NECESSARY.
QUALITY ASSURANCE LETTER OF INSTRUCTION
Planning Requirements
COMMENTS
NOTICE
Engineer
Date
Sheet1
| Contract No: 20--50000, 50001 |
| Date Contract Awarded: |
| Final Delivery Date FDD: |
| Program Name: F-15 |
| DODIC: 2404800-1 |
| undefined: V |
| undefined_2: V |
| undefined_3: V |
| undefined_4: M |
| undefined_5: W |
| undefined_6: V |
| undefined_7: V |
| undefined_8: V |
| undefined_9: N |
| undefined_10: |
| undefined_11: |
| undefined_12: |
| Text19: |
| Text20: |
| Text21: |
| Text22: |
| Text23: |
| Text24: 1.Inspection |
| Text25: 2. Leak Test |
| Text26: 3. X-Ray/N-Ray |
| Text27: 4. LAT Sample Selection |
| Text28: 5. LAT |
| Text29: 6. Preparation for Shipment |
| Text30: 7. AMMO Data Card Review |
| Text31: 8. Shippers (DD250, DD1149, Reports) |
| Text32: 9. Additional Requirements |
| Text33: |
| Text34: |
| Text35: |
| Text36: 1. Verify that the Explosive Weight is identified and meets drawing and hazard classification requirements. |
2. Verify gross/fine leak checks are performed per ATP requirements
3. Ensure film labeling correct. Ensure radiographic film readable/well-defined. DCMA not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Prior to LAT ensure proper calibration and validation of all test equipment. Testing should occur in accordance with latest government approved ATP.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer, original lot no., and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Notify and obtain approval from the Project Engineer for any additional requirements imposed by DCMA.
| 2018-05-01T10:16:24-0600 | |
| TIDWELL.QUINN.RAY.1241451913 |
| Text46: 17 Apr 2019 |
| Text49: |
| Type name_1: |
| Type name_4: |
| Part Number: MJ19 |
| Noun: |
File details come from the government source that posted it. Updated .