FIRE EXT CART. Federal contract opportunity
Solicitation number
FA8213-20-R-3005
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

View the file

Other files for this federal contract opportunity

Other files attached to FIRE EXT CART., newest first.
File Type Posted
260s27jun2019.pdf PDF
SPI_AD_P_1377_5.pdf PDF
AirSpec1377007561384.docx DOCX document
PackagingSOW.pdf PDF
ES7034.doc DOC document
CADPADIMI_20190501.pdf PDF
SPI_F01-271-7161.pdf PDF
QALI_1377012258235_1377012340912.pdf PDF
AirSpec1377012258235_1377012340912.docx DOCX document
ADC_SOW.doc DOC document
Packaging_Requirements_1377013915415_26Jun.pdf PDF
Packaging_Requirements1377012258235_1377012340912_18_sep.pdf PDF
ItemDescriptions11april2019.pdf PDF
Packaging_Requirements1377007561384_1_nov.pdf PDF
CDRLSMAY03.pdf PDF
FA821320R3005.RTF RTF text file
JFQR_1377016695313.pdf PDF
QALI_1377007561384.pdf PDF
REPSHIP.doc DOC document
BidSets1377013915415.doc DOC document
JFQR_1377007561384_03132020.pdf PDF
AirSpec1377013915415.docx DOCX document
SPI_F01-255-2382.pdf PDF
SPI_F00-280-0272.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contractor Name CAGE code

DCMA QAR Reviewer

Date Review Completed

Date Issued to Contractor

PR No. FD2020-

Date Contract Awarded

Final Delivery Date (FDD)

Program Name

DODIC

Part Number

The contractor is required to impose the listed below DCMA Inspection Points into the appropriate Work Orders.

All Work Orders pertaining to CRITICAL FLIGHT ITEMS must be identified on folders.

Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)

Witness - W: GSI required to attend, may reduce level of effort after 50% of production lots found acceptable

Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)

Monitor - R: Will monitor testing, may reduce to verification

Notify - N: By phone or email

Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)

Prepared by:

Date

Concurrence Signature by QAR/DCMA:

QAR/DCMA

THIS PLANNING SHEET WILL BE UPDATED IF NECESSARY.

QUALITY ASSURANCE LETTER OF INSTRUCTION

Planning Requirements

COMMENTS

NOTICE

Engineer

Date

Sheet1

Contract No: 20-50015, 20-50016
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: C-17 Fire Extinguisher
DODIC: MD61
undefined: V
undefined_2: V
undefined_3:
undefined_4: M
undefined_5: W
undefined_6: V
undefined_7: V
undefined_8: V
undefined_9: N
undefined_10:
undefined_11:
undefined_12:
Text19: Kidde, Applied Energy
Text20: 61423, 57597
Text21:
Text22:
Text23:
Text24: 1.Inspection
Text25: 2. Leak Test
Text26:
Text27: 3. LAT Sample Selection
Text28: 4. LAT
Text29: 5. Preparation for Shipment
Text30: 6. AMMO Data Card Review
Text31: 7. Shippers (DD250, DD1149, Reports)
Text32: 8. Additional Requirements
Text33:
Text34:
Text35:
Text36: 1. Verify that the Explosive Weight is identified and meets drawing and hazard classification requirements.

2. Verify gross/fine leak checks are performed per ATP requirements

3. Randomly select LAT units per latest government approved ATP.

4. Prior to LAT ensure proper calibration and validation of all test equipment. Testing should occur in accordance with latest government approved ATP.

5. Ensure Paperwork is correct.

6. Verify all energetic materials: list original manufacturer, original lot no., and latest certification/recertification date < 24 months.

7. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)

8. Notify and obtain approval from the Project Engineer for any additional requirements imposed by DCMA.

2019-04-24T09:18:42-0600
TANNER.MATTHEW.W.1379435919
Text46: 2019-04-24
Text49:
Type name_1:
Type name_4:
Part Number:
Noun: 446161-1, 201230