FA8201-16-T-A002-0002.pdf

PDF 131 KB Posted

Attached to
Personnel Trailers Federal contract opportunity
Solicitation number
FA8201-16-T-A002
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Amendment 0002. Offeror due date NOT extended. Please refer to attached amendment for details. Attached Statement of Need reflects changes made in both Amendment 0001 and Amendment 0002.

View the file

Other files for this federal contract opportunity

Other files attached to Personnel Trailers, newest first.
File Type Posted
20160725_Statement_of_Need _Rev_2_CE_Trailers_(PR_F2DCAF6145A001).pdf PDF
FA8201-16-T-A002-0001.pdf PDF
Responses_to_Inquiries_for_Solicitation_FA8201-16-T-A002_Personnel_Trailers.pdf PDF
FA8201-16-T-A002 _Personnel_Trailers.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F2DCAF6145A001

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83)

Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to:

1. Make changes to Statement of Need

2. Remove "installation" verbiage from CLIN 0001 & 0002 description.

3. All other terms and conditions remain unchanged.

POC: TSgt Christopher Castro, 801-586-9165, christopher.castro@us.af.mil

1. CONTRACT ID CODE PAGE OF PAGES

J 1 5

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 27-Jul-2016

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X FA8201-16-T-A002

X 9B. DATED (SEE ITEM 11)

19-Jul-2016

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

27-Jul-2016

CODE

OL:H/PZIOC

DETOREA OLIVER 6038 ASPEN AVE BLDG 1289

HILL AFB UT 84056-5805

FA8201 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

FA8201-16-T-A002

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SUPPLIES OR SERVICES AND PRICES

CLIN 0001

The CLIN extended description has changed from:

Restroom Trailer in accordance with attached Statement of Need. Pricing includes delivery and installation.

To:

Restroom Trailer in accordance with attached Statement of Need. Pricing includes delivery..

CLIN 0002

The CLIN extended description has changed from:

Breakroom Trailer in accordance with attached Statement of Need. Pricing includes delivery and installation.

To:

Breakroom Trailer in accordance with attached Statement of Need. Pricing includes delivery..

The following have been added by full text:

STATEMENT OF NEED REV 2

The government has a requirement for one (1) restroom trailer, and one (1) locker room trailer with the following specifications:

1.1 Restroom Trailer:

1.2 The restroom trailer shall be a minimum of 28’ long, a minimum of 8.3 feet wide with a minimum interior of 7.5 feet in height. Restroom trailers shall be towable with the use of a ¾ ton to 1 ton tow vehicle and have a hitch 2 and 5/16 ball for towing.

Restroom trailer shall have appropriate electric power hook up cord that will not exceed 208V/50 Amp and be 50 feet in length. The entire trailer will work off of this power cord and will have a main distribution panel in the utility room. The restroom trailer will include climate controls for heating and cooling. Restroom trailer shall have 1 holding tank that is min of 1000 gal for waste water and a hose connection for potable water. Restroom trailer shall include a small hot under the sink water heater to heat the water to 90 degrees. Restroom trailer shall have an accessible connection to pump and service the waste tank quickly. The furnishings for the units are as follow:

• Water proof wall system that will protect all of the outside walls from any water on the floor.

• Floor shall be a rubber type coin surface and sealed to the walls for a wash down type restroom.

• Restroom will included sinks with a vanity storage underneath, toilet paper holders, paper hand towels, and soap dispensers. Solid surface counter top and recessed sinks with high quality facets.

• Solid surface type toilet partition and urinal screens.

• Included in the layout of the trailer there shall be a small utility room with an outside door for storage and cooling and heating equipment.

• Ventilation system with outside air intake. The restroom trailer shall be made so that the whole trailer can be winterized very easily with the manufacture providing detailed instruction as to winterizing steps. The trailer shall be designed to have a structure and support steel frame along with axels, wheels, and suspension so the trailer can be towed on the highways at speeds of 70 miles an hour. Any water piping exposed shall be insulated and heat taped. This trailer will be exposed to temperatures ranging from 0 to 100 Degrees Fahrenheit. The small Mechanical room shall be heated as well.

1.3 Men’s Restroom: Shall have a minimum of 2 high quality toilets, 3 high quality urinals and 2 high quality sinks.

1.4 Women’s Restroom: Shall have a minimum of 5 high quality toilets, 2 high quality sinks.

2.1 Break Room Trailer: Size of this trailer will be a minimum of 28’ long, a minimum of 8.3 feet wide with a minimum interior of 7.5 feet in height. Trailer shall be towable with the use of a ¾ ton to 1 ton tow vehicle and have a hitch 2 and 5/16 ball for towing. Trailer shall have appropriate electric power hook up cord that will not exceed 208V/50 Amp and be 50 feet in length. The entire trailer will work off of this power cord and will have a main distribution panel in the utility room. The Trailer will include climate controls for heating and cooling.

Trailer shall have 1 holding tank that is a min of 500 gal for waste water and a hose connection for culinary water. Trailer shall include a small hot under the sink water heater to heat the water to 90 degrees Fahrenheit. Each trailer shall have the same accessible connection to pump and service the waste tank quickly. The furnishings for the units are as follow:

• Water proof wall system that will protect all of the outside walls from any water on the floor.

• Floor shall be a rubber type coin surface and sealed to the walls for a wash down type.

• Break room will include kitchen-type sinks with a cabinet storage top and bottom, as well as paper hand towel and soap dispensers.

• Solid surface counter top and recessed sinks with high quality faucets.

• Included in the layout of the trailer there shall be a small utility room with an outside door for storage and cooling and heating equipment.

• The breakroom trailer shall be made so that the whole trailer can be winterized very easily with the manufacture providing detailed instruction as to winterizing steps. The trailer shall be design to have a structure and support steel frame along with axels, wheels, and suspension so the trailer can be towed on the highways at speeds of 70 miles an hour. Any water piping exposed shall be insulated and heat tape. This trailer will be exposed to temperatures ranging from 0 to 100 Degrees Fahrenheit.

3.0 The exterior of both trailers shall be high quality metal or fiberglass surface that is completely sealed from the walls to the roof. All seams are to be double sealed and all penetrations will be double sealed. Walls shall be insulated. The hitch shall be painted high quality paint along with a rubberized under coating underneath the entire trailer. The trailer shall have traveling lights, running lights, turn signal and break lights. Trailer shall require that it is towable to 70 MPH,and include all department of transportation safety lights, turn signals, break lights and running lights. All Exterior doors shall be insulated with a weather striped door system hardware that can be completely locked and secured and also include a hydraulic closer. Both trailers shall have built in steps and handrails as required. Both trailers shall have adequate lighting up to 70 foot candles with lighting over all vanities and sinks, with exterior lights next to doors. Jacks shall be mounted in the corners of the trailers.

The following have been deleted: