Bldg. 680 Asbestos Report
View the file
Other files for this federal contract opportunity
Show all 41
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| DEPARTMENT OF THE AIR FORCE |
| 75 CIVIL ENGINEERING (CEOHA) |
| HILL AIR FORCE BASE, UTAH |
| LIMITED ASBESTOS INSPECTION REPORT, | HILL AFB BUILDING, 680 |
| CONSTRUCT TRAINING ROOMS EAST SIDE |
| Date Requested: | December 2015 | Re-Inspection Date: | 21 March 2016 | |
| Requester: | Terry Hess | Inspector: | Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397) | |
| Organization: | 309 AMXG/EN | |||
| Location & Building: | HILL AFB BUILDING, 680 | |||
| Work Order: | 58149 |
| Affected Area: | East Break Room and Exterior. |
| Statement of Work: | Construct new classroom east of break room. |
| Remove existing exterior doors, tie into new structure once constructed. | |
| Excavate for footings/foundation/utilities. |
This inspection was performed in accordance with the Utah Division of Air Quality (DAQ) requirements as found in the Utah Air Quality Rule R307-801-10. This inspection report is required to be on site during all abatement, renovation, and demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) utilizing method 600R-93-116 by The Science and Engineering laboratory at Hill Air Force Base, Utah.
Civil Engineering personnel also reviewed previous asbestos inspection reports of suspect asbestos containing building materials (ACM) that could potentially be encountered in this area. The information gathered from all current and previous inspections is shown below by homogenous area.
SUMMARY OF ASBESTOS CONTAINING MATERIALS FOUND
| MATERIAL TYPE | ASBESTOS | FRIABILITY (During Removal)* | *RACM *Category I *Category II | QUANTITY | *LOCATIONS FOUND |
| Buried pipes, cables, and conduits | Assumed | Friable and/or Non Friable | Potential, RACM | Unknown | East of existing facility: Underground |
| *Per UDAQ definition. |
| RACM: Regulated Asbestos-Containing Material (RACM)" means friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation project operations. |
| Category I Non-Friable ACM: Asbestos-containing packings, gaskets, resilient floor coverings, or asphalt roofing products containing more than 1% asbestos as determined by using the method specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM). |
| Category II Non-Friable ACM: Any material, excluding Category I non- friable ACM, containing more than 1% asbestos as determined by using the methods specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM) that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. |
| Locations found: Locations of building materials as described in this report indicate where they were found, but do not necessarily mean that these are the only locations where these materials may be encountered during the project. |
| Summary of materials containing ≤1% was identified via "Point Counting". ≤1% is not considered to be an asbestos containing material, but special handling/packaging requirements are necessary per OSHA 29CFR 1926.1101 and 29CFR 1910.1001 |
| MATERIAL TYPE | ASBESTOS | QUANTITY | *LOCATIONS FOUND |
| N/A | N/A | N/A | N/A |
The following is a list of the "Suspect Materials" that were sampled as part of this inspection:
| 12" Floor Tile, Grey/Adhesive yellow | Drywall/Joint Compound Wall System |
| 2'x4' Ceiling Tile, Wormygrooves/Pinholes, White | 2'x4' Ceiling Tile, Pockmarks/Pinholes, White |
| Ceiling Tile Batt Insulation, White | Wall Batt Insulation, White |
| Wall Board Insulation, White/Yellow | Thermal System Pipe Insualtion, Foil/Yellow |
| Thermal System Pipe Insualtion, White/Yellow | Thermal System Pipe Fitting Insulation, White/White |
| Pipe Insualtion Lagging, White |
| A total of | 37 | samples reference the | 11 | suspect materials assesses as part of the inspection. |
| The following table summarizes the sampling data. |
| Homogenous Building Material, Description, Location, Quantity. | Sample # | Sample Location | Results |
| 12" Floor Tile, Grey over Adhesive Yellow, 1,000 Square Feet | GM131300 | Southwest, Room 102 | None-Detected |
| GM131301 | Southeast, Room 101 | None-Detected | |
| GM131302 | Southwest, Room 108 | None-Detected | |
| Drywall/Joint Compound Wall System, 5,000 Square Feet | GM131308 | Southwest, Exterior, Room 124 | None-Detected |
| GM131309 | Northwest, Room 123 | None-Detected | |
| GM131310 | Southwest, Room 102 | None-Detected | |
| GM131311 | Southeast, Room 120 | None-Detected | |
| GM131312 | West Center, Room 121 | None-Detected | |
| GM131313 | South Center, Room 108 | None-Detected | |
| GM131314 | Northeast, Room 121 | None-Detected | |
| 2'x4' Ceiling Tile, Wormygrooves/Pinholes Pattern, White, 25 Square Feet | GM131321 | Northwest, East Office Hallway | None-Detected |
| 2'x4' Ceiling Tile, Pockmarks/Pinholes Pattern, White, 1,500 Square Feet | GM131325 | Southwest, Room 102 | None-Detected |
| GM131326 | Center, Room 103 | None-Detected | |
| GM131327 | Northwest, Room 108 | None-Detected | |
| GM131328 | Center, East Office Hallway | None-Detected | |
| GM131329 | Northeast, Room 101 | None-Detected | |
| Ceiling Tile Batt Insulation, White, 400 Square Feet | GM131335 | West Center, Room 120 | None-Detected |
| GM131336 | West Center, Room 121 | None-Detected | |
| GM131337 | East Center, Room 121 | None-Detected | |
| Wall Batt Insulation, White, 1,000 Square Feet | GM131338 | North Center, Hangar | None-Detected |
| GM131339 | Northwest, West Mezzanine | None-Detected | |
| GM131340 | Northwest, East Mezzanine | None-Detected | |
| Wall Board Insulation, White over Yellow, 500 Square Feet | GM131341 | Northeast, Hangar | None-Detected |
| GM131342 | Northwest, Hangar | None-Detected | |
| GM131343 | Southeast, Hangar | None-Detected |
| Thermal System Pipe Insulation, Foil/Yellow, 50 Linear Feet | GM131344 | North Center, West Mezzanine | None-Detected |
| GM131345 | Northwest, Room 106 | None-Detected | |
| GM131346 | West Center, Dock E-4 | None-Detected | |
| Thermal System Pipe Insulation, White over Yellow, 1,000 Linear Feet | GM131347 | Southeast, East Mezzanine | None-Detected |
| GM131348 | Northeast, Room 106 | None-Detected | |
| GM131349 | West Center, Dock E-4 | None-Detected | |
| Thermal System Pipe Fitting insulation, White over White | GM131350 | West Center, Room 106 | None-Detected |
| GM131351 | South Center, East Mezzanine | None-Detected | |
| GM131352 | West Center, Hangar | None-Detected | |
| Pipe Insulation Lagging, White, 200 Linear Feet | GM131353 | East Center, Dock E-3 | None-Detected |
| GM131354 | Southeast, East Mezzanine | None-Detected | |
| GM131355 | West Center, Dock E-1 | None-Detected |
Per EPA requirements, all materials analyzed as containing ≤10% asbestos are point counted utilizing EPA method 600/R-93/116.
| POTENTIAL FOR ADDITIONAL MATERIALS: |
| This inspection report only encompasses the areas/materials designated within this report. Should the scope of the project be altered in any way or any materials found that are not identified in this report shall require additional assessment. This report cannot be used for any other projects within the building. |
| This report was inspected by: |
| Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397) |
| of the 75 CES/CEOHA Asbestos/LBP Shop. |
| Any questions or concerns regarding this inspection report or if any new suspect asbestos containing material (ACM) is encountered, stop work and contact the personnel listed below for further assistance. |
CONTACT INFORMATION
Asbetsos/LBP Shop 75 CES(CEOHA)
| Supervisor: Nickolas King: | DSN: (801)586-7094 | Asbestos/LBP Shop (801)777-8006 |
| Cell: (801)430-4785 |
Building: 680
| Construct addition for training. | WO#: 58149 |
| &P | 21 march 2016 |
1000 Hours
Sheet2
| Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397) |
| Chase Johnson (Utah Certified Asbestos Inspector ASB#-5645) |
| Nickolas King (Utah Certified Asbestos Inspector ASB#-2257) |
| Raudel Arteaga (Utah Certified Asbestos Inspector ASB#-5863) |