Skid Mounted Blast Peening and Vacuum HEPA Systems
1. Does the Bullard electric breathing air system power need to be included in the ‘one main electrical hookup’ noted in paragraph #5? Yes
2. Paragraphs #1 and #4 call out a 35 gallon waste drum. The waste drum in paragraph #1 seems to be used with the dust collector, and the drum in #4 seems to be for the cyclone separator. Is this the same drum used to collect waste from the dust collector and the cyclone separator, or can it be the same drum? Yes it is the same drum
3. In the SOW title paragraph the breathing air system and the blast system are referred to as optional, but in the body the only option referred to is the blast system pot configuration as being .9 CF or 2 CF. Should the base price include the breathing air system? Yes
4. The breathing air system calls out 2 hood style respirators, but no length of breathing air hose.
How many breathing air hoses do you require, and of what length? 2 breathing air hoses 50ft each.