DEPARTMENT OF THE AIR FORCE
OKLAHOMA CITY AIR LOGISTICS COMPLEX
TINKER AIR FORCE BASE OKLAHOMA
2 October 2019
MEMORANDUM FOR RECORD
SUBJECT: Item Description, A20-004ADV GRINDER PUMPS
B3705 Reference: 56920-9 (17,000.00) 01 August 2019
1. The 569th Aircraft Maintenance Squadron (569 AMXS) is requesting utilization of funding for the purchase of two (2) Explosion Proof and Submersible Grinder Pumps.
2. The requested Explosion Proof and Submersible Grinder Pumps descriptions/specifications are outlined below.
a. Quantity: Two (2).
b. Pump Type: Submersible Chopper.
c. Suction and Discharge Size: Exactly 4 inches.
d. Pump Height: No more than 36 inches.
e. Motor Horse Power: Industry Rated 7.5 HP.
f. Revolutions per Minute: Industry Rated 1750 RPM.
g. Power Supply: Industry Rated 460V, 3 Phase, 60HZ.
h. Power Cord Length: 30 to 50 FT.
i. Percent of efficiency at the duty point of 300 GPM and 40 feet of head: 50% - 75%.
j. Max Fluid Temp: 104-120 Degrees Fahrenheit.
k. Explosion Proof: Class 1, Division 1.
l. Sensors: Moisture and Temperature.
m. Fluid Compatibility: Diluted Hydrogen Peroxide and Phenoyl Paint Strippers.
n. Break away fittings and hardware: Exactly 4 inch by 4 inches.
OC-ALC OBCA
SUBJECT: Item Description, A20-004ADV Grinder Pumps
3. Point of contact for this memorandum is your name at
File details come from the government source that posted it.