Wall_Specifications_17_Dec_15.pdf

PDF 151 KB Posted

Attached to
Conference Room Upgrade Federal contract opportunity
Solicitation number
FA8101-16-Q-0004
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

Wall specifications with diagram

View the file

Other files for this federal contract opportunity

Other files attached to Conference Room Upgrade, newest first.
File Type Posted
Ceiling_Photo_22_Dec_15.jpg JPG image
Solicitation_FA8101_16-Q-004_Vendor_Questions.docx DOCX document
Solicitation_FA8101_16-Q-004_Vendor_Questions.docx DOCX document
C_ROOM_SOW_revised_17_Dec_15.docx DOCX document
Wall_Plate_17_Dec_15.jpg JPG image
C-ROOM_Named_Brand_Justification.docx DOCX document
Memo_to_Vendors_Solicitation_FA8101-16-Q-0004.pdf PDF
FA8101-16-Q-0004.pdf PDF
SOW.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

60.00

(EXISTING WINDOW)

120.00 (EXISTING WINDOW)

EXISTING WALL

2" x 8" Lumber

3/4" Plywood

5.00

1393438394C Text Box View from Conference Room

1393438394C Text Box View from backroom

1393438394C Text Box Contractor shall remove the existing projector screen and install the necessary framing to support the new mounting hardware and video wall components. Then new frame shall allow the new video monitors to be flush with the North facing wall when installed.

-Paint to match existing colors.

-Back room framing to be painted black.

-Trim to match existing trim stain.

-Frame existing window only -Area in back room is to remain open to allow for ventilation, access and cables.

-utilize power for panels from outlets below window.(relocate to inside of back room.