The purpose of this amendment is to correct the scale of measurement in the drawings. Please see attached corrected drawings. Please submit quotes by 4 00pm Central time on July 29th 2015.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Drawing.pdf | ||
| Q_ _A.pdf | ||
| Wage_Determination.pdf | ||
| FA6633-15-T0009.doc | DOC document | |
| 02_QJKL_15-0042-Technical_Drawings.pdf | ||
| 01_QJKL_15-0042-_Statement_of_Work-06262015.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 1 1 1
1 1 1 1
T-1
MINNEAPOLIS MINNESOTA
760 MILITARY HIGHWAY
55450-2100
934th AIRLIFT WING
UNITED STATES AIR FORCE RESERVE
Repair Shower, Bathroom, Locker Room Tile, Building 777
QJKL 15-0042
PROJECT NUMBER
VIKINGS
FLYING
1 1 1 1
AD-1
PHENOLIC PARTITION,
REMOVE AND REINSTALL
(WOMEN'S SIMILAR)
CT4
~3 6"
ACCENT TILES AND ABOVE NOT TO BE
REMOVED
ALL TILES BELOW
ACCENT TILES TO BE
REMOVED
WORK AREA HATCHED
REMOVE AND DISPOSE OF TILE AND
UNDERLYING THINSET
REMOVE AND REINSTALL BENCHES
AFTER TILE INSTALLATION
A-3
A-3
REMOVE AND DISPOSE OF TILE AND
UNDERLYING THINSET ON ALL SHOWER
WALLS UP TO, BUT NOT INCLUDING THE
DECORATIVE TILE, ~36"
REMOVE AND REINSTALL DOORS AFTER TILE
INSTALLATION
A-3
REMOVE AND REINSTALL BENCHES
AFTER TILE INSTALLATION
REMOVE AND REINSTALL BENCHES
AFTER TILE INSTALLATION
CT4
REMOVE AND REINSTALL PARTITIONS AND
DOORS IN ORIGINAL LOCATIONS AFTER TILE
INSTALLATION
IF NECESSARY, REMOVE AND REINSTALL
PARTITION IN ORIGINAL LOCATION AFTER TILE
INSTALLATION
REMOVE AND REINSTALL PARTITIONS AND
DOORS IN ORIGINAL LOCATIONS AFTER TILE
INSTALLATION
1 1 1 1
ROOM FINISH SCHEDULE
ROOM NUMBER ROOM NAME FLOOR BASE WALLS
NORTH SOUTH EAST WEST HEIGHT
103 MEN'S TOILET CT3 CT3
104 MENS LOCKER CT3 CT3
105 MEN'S SHOWER CT3* CT3* CT4 CT4 CT4 CT4 3'-0"
106 WOMEN'S LOCKER CT3 CT3
107 WOMEN'S SHOWER CT3* CT3* CT4 CT4 CT4 CT4 3'-0"
108 WOMEN'S TOILET CT3 CT3
CT3
PHENOLIC PARTITION,
REMOVE AND REINSTALL
AS NECESSARY
(WOMEN'S SIMILAR)
CT4
~3 6"
ACCENT TILES AND ABOVE NOT TO BE
REMOVED
INSTALL TILES (CT4), GROUT,
AND SEAL BELOW ACCENT
TILES ACCORDING TO
MANUFACTURER'S
INSTRUCTIONS
INSTALL FLOOR AND COVE TILE, GRIOUT AND SEAL
(CT3) ACCORDING TO MANUFACTURER'S
INSTRUCTIONS ON ALL SURFACES, TO INCLUDE:
SHOWER FLOORS, LOCKER ROOM FLOORS,
RESTROOM FLOORS AND COVE TILE UNDER THE
LOCKERS
REINSTALL BENCHES IN
ORIGINAL LOCATIONS
REINSTALL BENCHES IN ORIGINAL LOCATIONS
REINSTALL BENCHES IN ORIGINAL LOCATIONS
CT3
CT3
CT3
A-2
A-2
A-2
~SQFT
Wall FLR 700 1668
~LF
FLR-S FLR - RR & LR
232 421
1 INSTALL TILE (CT4), GROUT AND SEAL ACCORDING TO
MANUFACTURER'S INSTRUCTIONS ON ALL SHOWER WALLS,
UP TO, BUT NOT INCLUDING THE DECORATIVE TILE, ~36"
REINSTALL SHOWER DOORS IN ORIGINAL LOCATIONS
REINSTALL PARTITIONS AND DOORS IN
ORIGINAL LOCATIONS
REINSTALL PARTITIONS AND DOORS IN
ORIGINAL LOCATIONS
REINSTALL PARTITION IN
ORIGINAL LOCATION
WORK AREA HATCHED
A-2
REMOVE AND DISPOSE OF TILE AND UNDERLYING THINSET ON
SHOWER FLOOR AND ALL SHOWER WALLS UP TO, BUT NOT
INCLUDING THE DECORATIVE TILE, ~36"
INSTALL NEW TILE(CT4), GROUT, AND SEAL ACCORDING TO
MANUFACTURER'S INSTRUCTIONS
REMOVE AND DISPOSE OF TILE AND UNDERLYING THINSET ALONG ALL
FLOORS, TO INCLUDE; LOCKER ROOMS, REST ROOMS, SHOWERS AS WELL
AS UNDER THE LOCKERS
INSTALL NEW TILE(CT3), GROUT, AND SEAL ACCORDING TO
MANUFACTURER'S INSTRUCTIONS
DO NOT REMOVE DECORATIVE TILE