1 1 1 1

1 1 1 1

T-1

MINNEAPOLIS MINNESOTA

760 MILITARY HIGHWAY

55450-2100

934th AIRLIFT WING

UNITED STATES AIR FORCE RESERVE

Repair Shower, Bathroom, Locker Room Tile, Building 777

QJKL 15-0042

PROJECT NUMBER

VIKINGS

FLYING

1 1 1 1

AD-1

PHENOLIC PARTITION,

REMOVE AND REINSTALL

(WOMEN'S SIMILAR)

CT4

~3 6"

ACCENT TILES AND ABOVE NOT TO BE

REMOVED

ALL TILES BELOW

ACCENT TILES TO BE

REMOVED

WORK AREA HATCHED

REMOVE AND DISPOSE OF TILE AND

UNDERLYING THINSET

REMOVE AND REINSTALL BENCHES

AFTER TILE INSTALLATION

A-3

A-3

REMOVE AND DISPOSE OF TILE AND

UNDERLYING THINSET ON ALL SHOWER

WALLS UP TO, BUT NOT INCLUDING THE

DECORATIVE TILE, ~36"

REMOVE AND REINSTALL DOORS AFTER TILE

INSTALLATION

A-3

REMOVE AND REINSTALL BENCHES

AFTER TILE INSTALLATION

REMOVE AND REINSTALL BENCHES

AFTER TILE INSTALLATION

CT4

REMOVE AND REINSTALL PARTITIONS AND

DOORS IN ORIGINAL LOCATIONS AFTER TILE

INSTALLATION

IF NECESSARY, REMOVE AND REINSTALL

PARTITION IN ORIGINAL LOCATION AFTER TILE

INSTALLATION

REMOVE AND REINSTALL PARTITIONS AND

DOORS IN ORIGINAL LOCATIONS AFTER TILE

INSTALLATION

1 1 1 1

ROOM FINISH SCHEDULE

ROOM NUMBER ROOM NAME FLOOR BASE WALLS

NORTH SOUTH EAST WEST HEIGHT

103 MEN'S TOILET CT3 CT3

104 MENS LOCKER CT3 CT3

105 MEN'S SHOWER CT3* CT3* CT4 CT4 CT4 CT4 3'-0"

106 WOMEN'S LOCKER CT3 CT3

107 WOMEN'S SHOWER CT3* CT3* CT4 CT4 CT4 CT4 3'-0"

108 WOMEN'S TOILET CT3 CT3

CT3

PHENOLIC PARTITION,

REMOVE AND REINSTALL

AS NECESSARY

(WOMEN'S SIMILAR)

CT4

~3 6"

ACCENT TILES AND ABOVE NOT TO BE

REMOVED

INSTALL TILES (CT4), GROUT,

AND SEAL BELOW ACCENT

TILES ACCORDING TO

MANUFACTURER'S

INSTRUCTIONS

INSTALL FLOOR AND COVE TILE, GRIOUT AND SEAL

(CT3) ACCORDING TO MANUFACTURER'S

INSTRUCTIONS ON ALL SURFACES, TO INCLUDE:

SHOWER FLOORS, LOCKER ROOM FLOORS,

RESTROOM FLOORS AND COVE TILE UNDER THE

LOCKERS

REINSTALL BENCHES IN

ORIGINAL LOCATIONS

REINSTALL BENCHES IN ORIGINAL LOCATIONS

REINSTALL BENCHES IN ORIGINAL LOCATIONS

CT3

CT3

CT3

A-2

A-2

A-2

~SQFT

Wall FLR 700 1668

~LF

FLR-S FLR - RR & LR

232 421

1 INSTALL TILE (CT4), GROUT AND SEAL ACCORDING TO

MANUFACTURER'S INSTRUCTIONS ON ALL SHOWER WALLS,

UP TO, BUT NOT INCLUDING THE DECORATIVE TILE, ~36"

REINSTALL SHOWER DOORS IN ORIGINAL LOCATIONS

REINSTALL PARTITIONS AND DOORS IN

ORIGINAL LOCATIONS

REINSTALL PARTITIONS AND DOORS IN

ORIGINAL LOCATIONS

REINSTALL PARTITION IN

ORIGINAL LOCATION

WORK AREA HATCHED

A-2

REMOVE AND DISPOSE OF TILE AND UNDERLYING THINSET ON

SHOWER FLOOR AND ALL SHOWER WALLS UP TO, BUT NOT

INCLUDING THE DECORATIVE TILE, ~36"

INSTALL NEW TILE(CT4), GROUT, AND SEAL ACCORDING TO

MANUFACTURER'S INSTRUCTIONS

REMOVE AND DISPOSE OF TILE AND UNDERLYING THINSET ALONG ALL

FLOORS, TO INCLUDE; LOCKER ROOMS, REST ROOMS, SHOWERS AS WELL

AS UNDER THE LOCKERS

INSTALL NEW TILE(CT3), GROUT, AND SEAL ACCORDING TO

MANUFACTURER'S INSTRUCTIONS

DO NOT REMOVE DECORATIVE TILE