Drawings.pdf
PDF 5 MB Posted
- Attached to
- REPAIR WOMENS RESTROOM BLDG 821
- Solicitation number
- FA6633-15-T0005
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SV_Attendance_Roster_8Apr15.pdf | ||
| Questions-Responses_15_April_2015.doc | DOC document | |
| Revised_Wage_Determination.pdf | ||
| Amendment_0001.doc | DOC document | |
| Specifications.pdf | ||
| FA6633-15-T0005 _RFQ.doc | DOC document | |
| Wage_Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA OF WORK
BLDG 821
PLAN NORTH
BASE CONTRACTING
BLDG 729
BASE CIVIL ENGINEERING
BLDG 744
MAIN GATE
CONSTRUCTION HAUL ROUTE
801 802
820FREE ZONE
E N
T E
R
WORK AREA
1. THE CONTRACTOR MUST COORDINATE WITH THE ASSIGNED GOVERMENT
ESCORT BEFORE ENTERING OR LEAVING THE CONTROLLED AREA THROUGH
ACCESS GATE BY BUILDING 802. ALL CONTRACTOR RESOURCES (VEHICLES,
EQUIPMENT, ETC.) MUST USE A DIRECT ROUTE BETWEEN THE ACCESS GATE AND
THE FREE ZONE ENTRANCE AND ARE NOT ALLOWED IN OTHER ADJACENT
CONTROLLED/RESTRICTED AREAS (UNLESS SPECIAL ARRANGEMENTS ARE PRE-
COORDINATED AND APPROVED IN ADVANCE.)
2. AT THE BEGINNING OF EACH WORK DAY, THE CONTRACTOR MUST NOTIFY THE
ASSIGNED GOVERNMENT ESCORT BEFORE OPENING THE ENTRANCE TO THE FREE
ZONE AREA. LIKEWISE, AT THE END OF THE WORK DAY, THE CONTRACTOR MUST
AGAIN NOTIFY THE GOVERNMENT ESCORT BEFORE CLOSING THE ENTRANCE TO THE
FREE ZONE AREA.
3. CONTRACTOR SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS FOR
PROVIDING THE FREE ZONE BARRICADES:
• BARRICADES SHALL BE ELEVATED ROPES AND CONES.
• IF THE BARRICADES ARE MOVED, TURNED OVER, ETC. BY HIGH WINDS; THE
CONTRACTOR SHALL RESPOND IMMEDIATELY TO RESTORE THE FREE ZONE
BARRICADES IN THEIR ORIGINAL POSITION
FREE ZONE GENERAL NOTES:
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
934TH AIRLIFT WING
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
G-001
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
C O
V E
R S
H E
E T
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
MINNEAPOLIS-SAINT PAUL AIR RESERVE STATION
REPAIR WOMEN'S RESTROOM - BUILDING 821
JANUARY 7, 2015
760 MILITARY HIGHWAY
MINNEAPOLIS, MN 55450-2100
CONTRACT NUMBER: FA6643-10-D-0002
TASK ORDER NUMBER: 6N10
PROJECT NUMBER: QJKL 14-0019
F A
-1
-D
-0
# OF
TOTAL
Sheet Number_Pr oject2 SHEET TITLE
GENERAL
1 G-001 COVER SHEET
ARCHITECTURAL
2 A-001 GENERAL NOTES & LEGENDS
3 A-002 PARTITION TYPES & DETAILS
4 AD101 DEMOLITION DETAILS
5 A-101 NEW WORK FLOOR PLAN & REFLECTED CEILING PLAN
6 A-501 RESTROOM DETAILS
7 A-502 RESTROOM ELEVATIONS
PLUMBING
8 P-001 GENERAL NOTES, LEGENDS, DETAILS, AND SCHEDULE
9 P-401 PLUMBING ENLARGED PLANS
MECHANICAL
10 M-001 GENERAL NOTES, LEGENDS, DETAILS AND SCHEDULES
11 M-401 MECHANICAL ENLARGED PLANS
ELECTRICAL
12 E-001 ELECTRICAL GENERAL NOTES AND LEGENDS
13 ED101 SECOND FLOOR DEMOLITION PLANS
14 E-101 SECOND FLOOR NEW WORK PLANS
15 E-601 LIGHT FIXTURE DETAILS AND SCHEDULES
Grand total: 15
INDEX OF DRAWINGS
SCALE: NOT TO SCALE
BASE LOCATION MAP
SCALE: NOT TO SCALE
AREA LOCATION MAP
SCALE: 1" = 60'-0"
FREE ZONE AREA BASE MAP
CONTRACTING OFFICER: CYNTHIA MURRY
PHONE: 612-713-1427
EMAIL: cynthia.murry@us.af.mil
ADDRESS: 934 CONF/LGC
760 MILITARY HIGHWAY, BLDG 729
MINNEAPOLIS-ST PAUL ARS, MIN 55450-2100
OWNER
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
1. ALL EXISTING CONDITIONS AND DIMENSIONS SPECIFIED PER ORIGINAL DESIGN
DRAWINGS AND NON-DESTRUCTIVE SITE INVESTIGATIONS. CONTRACTOR SHALL
VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF
DEMOLITION/CONSTRUCTION (TYP.) AND NOTIFY GOVERNMENT PROMPTLY IF ANY
DISCREPANCIES EXIST.
2. REMOVE ALL EXISTING WORK/MATERIAL, AS DESIGNATED, IN THEIR ENTIRETY
DOWN TO ORIGINAL SUBSTRATES IN INDICATED AREAS TO PERMIT COMPLETION OF
ALL REPAIRS AND REPLACEMENTS.
3. REMOVE ABANDONED PENETRATIONS.
GENERAL DEMOLITION NOTES:
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF THE WORK. THE DRAWINGS ARE NOT
INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL
PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS, ON THE BASIS OF THE GENERAL PERFORMANCE CRITERIA AND GENERAL
EXTENT OF WORK INDICATED, DESCRIBED OR REQUIRED.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT
DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR
IMPLIED THEREFROM.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK
SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S
PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS,
ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING
REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE
CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL PROTECT EXISTING, IN-PLACE, AND NEW WORK.
6. ALL WORK NOTED "N.I.C." OR "G.F.G.I." IS NOT MEANT TO BE PART OF THE CONSTRUCTION
SCOPE OF WORK AGREEMENT.
7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE COLLECTION, SEPARATION,
RECYCLE, REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.
8. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND
EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS, AT THE SITE. THE CONTRACTOR
SHALL NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY DIFFERING CONDITIONS
BEFORE COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SHALL CONSTITUTE
ACCEPTANCE OF ALL NEW OR EXISTING CONDITIONS.
9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER
SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN
WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
10.UNLESS NOTED OTHERWISE, ALL NEW GYPSUM BOARD SURFACES ARE TO RECEIVE ONE
PRIMER COAT AND TWO COATS OF PAINT.
11.DIMENSIONS NOTED AS 'HOLD' SHALL NOT VARY BY MORE THAN 1/8" FROM SIDE TO SIDE
OR FROM FRONT TO BACK, FINISHED SURFACE TO FINISHED SURFACE.
12.NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION
OPERATIONS SHALL BE APPLIED.
13.WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING
SHALL BE CONSTRUCTED AS DETAILED OR REFERENCED BY UL OR OTHER REFERENCE.
14.DIMENSIONS SHOWN ARE TO FINISH FACE OF WALL UNLESS SPECIFICALLY NOTED
OTHERWISE.
15.PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT
MANUFACTURER'S STANDARDS.
16.THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE
CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY
BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
17.ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF ALL
APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES.
18.ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC
CORROSION.
19.NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS.
SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO
RELATED DRAWINGS AND DETAILS.
20.A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL
IS TO BE FINISHED OR FIRE-RATED AS INDICATED.
21.WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR OPENINGS,
THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE THE LOCATION OF
ADJACENT WALLS AND FRAMES.
22.DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE SPECIFIC
DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE
CONTRACTING OFFICER BEFORE PROCEEDING WITH THE WORK.
23.THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR AND
WALL SLEEVES, CONDUIT AND ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE
PROTECTION, STRUCTURAL AND ARCHITECTURAL ITEMS.
24.PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR
MECHANICAL EQUIPMENT AND PLUMBING WORK. ALL ACCESS PANEL LOCATIONS SHALL
BE REVIEWED WITH THE CONTRACTING OFFICER PRIOR TO PROCEEDING.
25.ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS
SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS,
FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.
26.CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE PROTECTION FOR
PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO
AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
27.CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN OR
ABOUT EXISTING FACILITIES WITH CONTRACTING OFFICER, PRIOR TO START OF SUCH
WORK.
28.INTERIOR PARTITION AND CEILING MOVEMENT CONTROL:
A. VERTICAL CONTROL JOINTS FOR ANY GWB WALL LENGTH ARE TO OCCUR AT NOT MORE
THAN 30'-0" O.C. (900 SQ. FT. MAX) IN THE HORIZONTAL DIRECTION, UNLESS NOTED
OTHERWISE.
B. HORIZONTAL CONTROL JOINTS FOR ANY GWB CEILINGS ARE TO OCCUR AT NOT MORE
THAN 30'-0" O.C. (900 SQ. FT. MAX) IN THE VERTICAL DIRECTION, UNLESS NOTED
OTHERWISE.
C. THE TYPICAL MOVEMENT OF THE STRUCTURE DUE TO DEFLECTION AT THE HEAD OF THE
WALL CONSTRUCTION RUNNING TO THE UNDERSIDE OF THE STRUCTURE SHALL BE PLUS
OR MINUS 1/2".
GENERAL NEW WORK NOTES:
EARTH
STRUCTURAL FILL
GRAVEL/STONE
CONCRETE/GROUT
CONCRETE
MASONRY UNITS
(CMU)
CMU IN SECTION
FACE BRICK
IN SECTION
CMU RUNNING
BOND ELEVATION
MODULAR BRICK
ELEVATION
EXPOSED FINISHED
WOOD TRIM IN SECTION
RIGID INSULATION
IN SECTION
BATT INSULATION
- THERMAL
SAND/E.I.F.S./
PLASTER/STUCCO
MATERIAL INDICATIONS:
STEEL IN SECTION
PLYWOOD IN SECTION
ELEVATIONS OF GLAZING
A1 View Name
SCALE: 1/8" = 1'-0"
DRAWING VIEW TITLE
DRAWING VIEW SCALE
DRAWING VIEW NUMBER
DRAWING TITLE INDICATOR
REVISION NUMBER
LIMIT OF REVISION AREA
REVISION CLOUD AND
NUMBER INDICATOR
DETAIL NUMBER
SHEET DETAIL IS LOCATED ON
LIMIT OF ENLARGED AREA
ENLARGED DETAIL/AREA INDICATOR
DIRECTION OF CUTTING PLANE
DETAIL NUMBER
SHEET DETAIL IS LOCATED ON
BUILDING SECTION INDICATOR
LINE OF CUTTING PLANE
DIRECTION OF CUTTING PLANE
DETAIL NUMBER
LINE OF CUTTING PLANE
WALL SECTION INDICATOR
SHEET DETAIL IS LOCATED ON
LIMIT OF CUTTING PLANE
DETAIL NUMBER
DIRECTION OF ELEVATION
EXTERIOR ELEVATION INDICATOR
SHEET DETAIL IS LOCATED ON
DETAIL NUMBER
DIRECTION OF ELEVATION
INTERIOR ELEVATION INDICATOR
SHEET DETAIL IS LOCATED ON
DETAIL NUMBER
SHEET DETAIL IS LOCATED ON
DETAIL CALLOUT INDICATOR
(MULTIPLE CALLOUTS)
A1
A-101
A2
A-102
A3
A-103
DRAWING SCALE INDICATOR164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
NORTH ARROW
A101
A1 Ref
A101
A1
Ref
SYMBOLS:
A101
A1
Ref
A101
A1
Ref
A1
A-101
LIMIT OF CUTTING PLANE
PLAN NORTH
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
A-001
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
G E
N E
R A
L N
O T
E S
L
E G
E N
D S
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
F A
-1
-D
-0
ARCHITECTURAL ABBREVIATIONS
PRE-FAB PREFABRICATED
Q
Q.T. QUARRY TILE
R
RECEP. RECEPTIONIST
REF. REFERENCE
REINF. REINFORCEMENT
REQ'D REQUIRED
REV. REVISIONS / REVISED
RH RIGHT HAND
RHR RIGHT HAND REVERSE
R.D. ROOF DRAIN
RM. ROOM
R.O. ROUGH OPENING
RB RUBBER BASE
S
SCHED. SCHEDULE
SECT. SECTION
SHT. MET. SHEET METAL
SIM. SIMILAR
SCWD SOLID CORE WOOD
STC SOUND TRANSMISSION CLASS
SPEC. SPECIFICATION
SFRM SPRAYED FIRE-RESISTIVE
MATERIAL
SQ. SQUARE
ST. STAIN
S.S. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURAL
SUSP. SUSPENDED
T
TEL. TELEPHONE
TG TEMPERED GLASS
THK. THICK
T'HOLD THRESHOLD
TOIL. TOILET
TOC TOP OF CONRETE
TC TOP OF CURB
TOS TOP OF STEEL
TW TOP OF WALL
TU TOUCH UP
TYP. TYPICAL
U
UL UNDERWRITERS
LABORATORIES
UNFIN. UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
V
V.T.R. VENT THRU ROOF
VERT. VERTICAL
VCT VINYL COMPOSITION TILE
VCB VINYL COVE BASE
W
W.C. WATER CLOSET
W.R.G.B. WATER-RESISTANT GYP.
BOARD
W.S. WEATHERSTRIPPING
W. WIDTH
WDW. WINDOW
W.R.O. WINDOW ROUGH OPENING
W.M.P. WIRE MESH PARTITION
W/ WITH
W/O WITHOUT
WD. WOOD
Y
YD. YARD
ARCHITECTURAL ABBREVIATIONS
FTG. FOOTING
FDN. FOUNDATION
G
GA. GAGE OR GAUGE
GALV. GALVANIZED
GL. GLASS
GOVT. GOVERNMENT
G.F.G.I. GOVERNMENT FURNISHED /
GOVERNMENT INSTALLED
GYP. GYPSUM
GYP. BD.
(GWB)
GYPSUM BOARD
G.B.F. GYPSUM BOARD FURRING
H
HR. HANDRAIL
HDW. HARDWARE
H.V.A.C. HEATING VENTILATION & AIR
CONDITIONING
HGT. HEIGHT OR HIGH
H.P. HIGH POINT
H.M. HOLLOW METAL
HKS HOOKS
HORIZ. HORIZONTAL
HB HOSE BIBB
I
IN. INCH
INSUL. INSULATION
INT. INTERIOR
J
JAN. JANITOR
J.C. JANITOR'S CLOSET
JT JOINT
JST. JOIST
L
LAM. LAMINATE
LDG LANDING
LAV. LAVATORY
L.H. LEFT HAND
LHR LEFT HAND REVERSE
LT. LIGHT
LTG LIGHTING
LONG. LONGITUDINAL
LVR. LOUVER
LP. LOW POINT
M
MGR. MANAGER
MANUF. MANUFACTURER
MAS. MASONRY
M.O. MASONRY OPENING
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MET. METAL
MIN. MINIMUM
MISC. MISCELLANEOUS
N
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
NO. (#) NUMBER
O
OSHA OCCUPATIONAL SAFETY AND
HEALTH ACT
O.C. ON CENTER
O.W. OPEN WEB
OPNG. OPENING
OPP. OPPOSITE
O.H. OPPOSITE HAND
P
PT PAINT
PR. PAIR
PNL PANEL
PART. PARTITION
PLAS. PLASTER
PLAN. PLASTIC LAMINATE
PL PLATE
PLYWD PLYWOOD
LBS. POUNDS
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
PDU POWER DISTRIBUTION UNIT
P.M.J.F. PRE-MOLDED JOINT FILLER
ARCHITECTURAL ABBREVIATIONS
A
A.F.F. ABOVE FINISHED FLOOR
ACC. DR. ACCESS DOOR/PANEL
ACCESS. ACCESSORIES
ACOUST. ACOUSTICAL
ACT. ACTIVE
ADJ. ADJUST/ADJUSTABLE
A.C. AIR CONDITIONING
ALUM. ALUMINUM
ADAAG AMERICAN WITH DISABILTITES
ACCESSIBILITY GUIDELINES
A.B. ANCHOR BOLT
& AND
ANG. ANGLE
APP. APPROVED
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
A.W.I. ARCHITECTURAL WOODWORK
INSTITUTE
@ AT
AVG. AVERAGE
B
BM. BEAM
BLKG. BLOCKING
BD. BOARD
BTM. BOTTOM
B.H.M.I. BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION, INC.
BLDG. BUILDING
C
CPT. CARPET
CLG. CEILING
CLG. HT. CEILING HEIGHT
CTR. CENTER
C. TO C. CENTER TO CENTER
CL. CENTERLINE
C.T. CERAMIC TILE
CH. CHANNEL
C.O. CLEANOUT
CLR. CLEAR
CLOS. CLOSET
COL. COLUMN
CO. COMPANY
CONC. CONCRETE
CMU CONCRETE MASONRY UNIT
CONF. CONFERENCE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
C.J. CONTROL JOINT
CORR. CORRIDOR
C.Y. CUBIC YARD
D
DESC. DESCRIPTION
DET. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
DR. DOOR
DN. DOWN
D.S. DOWNSPOUT
DWG. DRAWING
E
EA. EACH
ELEC. ELECTRICAL OR ELECTRIC
EL. ELEVATION
ENGR. ENGINEER
E.P. EPOXY PAINT
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
E.J. (EXP. JT.) EXPANSION JOINT
EXP. EXPANSION/EXPOSED
EXP. TO
STRUCT.
EXPOSED TO STRUCTURE
EXT. EXTERIOR
F
FT. FEET
FV. FIELD VERIFY
FIN. FINISH
F.F. FINISHED FLOOR
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
FLR. FLOOR
F.D. FLOOR DRAIN
FLOUR. FLUORESCENT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
1. STUD DESIGN CRITERIA: ALL INTERIOR, NON-LOAD BEARING METAL STUDS
SHALL BE 25 GAUGE (MIN.) UNLESS OTHERWISE NOTED. STUDS SHALL BE
DESIGNED FOR A 5 PSF MIN. APPLIED LATERAL LOAD, L/240 MAX. DEFLECTION
STUD THICKNESS (GA.) AND DEPTHS INDICATED ARE MINIMUMS, WHILE STUD
SPACING IS A MAXIMUM ON CENTER SPACING. WHERE REQUIRED PARTITION
HEIGHTS EXCEED ALLOWABLE CRITERIA, STUD THICKNESS SHALL BE
INCREASED AND/OR STUD SPACING REDUCED AS REQUIRED TO MEET
STATED CRITERIA. WHERE WALL HUNG CABINETS, EQUIPMENT, OR FIXTURES
ARE INDICATED, PROVIDE 20 GA. MIN. STUDS.
2. TYPICAL FLOOR PLAN DIMENSIONS OF PARTITIONS ARE TO FACE OF STUD
OR TO COLUMN CENTERLINE.
3. INSTALLATION OF GYPSUM BOARD, BACKER BOARD, AND BASE BOARD
SHALL CONFORM TO REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL
RATINGS.
4. PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREAS THAT ARE
NOTED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMIC OR PORCELAIN TILE
FINISH.
5. PROVIDE 5/8" GYPSUM BOARD UNLESS OTHERWISE NOTED.
6. PROVIDE 5/8" TYPE X GYPSUM BOARD AT FIRE RATED PARTITIONS.
7. GA (IF NOTED) AND UL TEST NUMBERS WILL VARY DEPENDING ON THE
MANUFACTURER OF COMPONENTS ACTUALLY USED.
8. INSTALL BLOCKING OR BACKER MATERIAL FOR ATTACHMENT/MOUNTING OF
WALL HUNG ITEMS OR EQUIPMENT DESCRIBED IN THE DOCUMENTS.
9. WHEN INSTALLING GYPSUM BOARD, CONTRACTOR SHALL COMPLY WITH
REQUIREMENTS OF THE MOST CURRENT EDITION OF THE GYPSUM
ASSOCIATION GA-600 FIRE RESISTANCE DESIGN MANUAL AND THE MOST
CURRENT EDITION OF THE UL FIRE RESISTANCE DIRECTORY.
10.PARTITIONS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE SHALL
HAVE THE GWB CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE TO THE SHAPE
OF THE DECK ABOVE. GWB SHALL BE CONTINUOUSLY SEALED FOR THE FULL
DEPTH OF THE GWB WITH FLEXIBLE SEALANT.
11.GWB SHALL BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELEC.
OUTLET BOXES AND THE GWB DOES NOT EXCEED 1/8".
12.THE BOTTOM OF THE GWB AT INTERIOR PARTITIONS SHALL BE 1/4" MINIMUM
AND 1/2" MAXIMUM ABOVE THE CONCRETE FLOOR SLAB AND SHALL BE
SEALED FOR THE FULL DEPTH OF THE GWB WITH FLEXIBLE SEALANT.
13.REFER TO THE FLOOR PLAN FOR EXTENT OF FIRE WALL RATINGS.
14.ALL PARTITIONS SHALL BE ACOUSTICALLY RATED UNLESS OTHERWISE
NOTED. ALL ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALL EXTEND TO
ROOF OR FLOOR DECK ABOVE.
15.NOTE: SOME PARTITION TYPES MAY NOT BE USED ON THIS PROJECT.
16.REFER TO "PARTITION TYPE SUBSCRIPT KEY" BELOW FOR SYMBOLS USED
TO IDENTIFY ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO BASIC
PARTITION TYPES.
17.PARTITION TYPES DESCRIBE GENERAL REQUIREMENTS FOR PARTITIONS.
REFER TO THE MANUFACTURERS' SPECIFICATIONS AND REQUIREMENTS OF
APPLICABLE TESTING AGENCIES FOR SPECIFICS OF PARTITION
CONSTRUCTION.
18.WHERE A CLEAR DIMENSION OR OPENING IS REQUIRED OR NOTED,
MEASURE DIMENSION TO FACE OF PARTITION FINISH.
19.REFER TO INTERIOR FINISH SCHEDULE FOR ALL WALL FINISHES.
GENERAL NOTES FOR INTERIOR PARTITIONS
PARTITION
TYPE
STUD
WIDTH
3 5/8"
PARTITION
WIDTH
5 3/8"
STC
NA
NOTES
NONEA
SCALE:
NON-RATED STUD WALL
1 1/2" = 1'-0"
A
ACOUSTIC INSULATION
5/8" GYPSUM WALLBOARD
3 5/8"METAL STUDS @ 16" O.C.
WALL TILE WAINSCOT TO 4'-10"
5/8" MOISTURE RESISTANT GWB
PARTITION
TYPE
STUD
WIDTH
3 5/8"
PARTITION
WIDTH
5 7/8"
STC
NA
NOTES
NONEB
SCALE:
NON-RATED STUD WALL
1 1/2" = 1'-0"
B
WALL TILE WAINSCOT TO 4'-10"
5/8" MOISTURE RESISTANT GWB
3 5/8"METAL STUDS @ 16" O.C.
WALL TILE WAINSCOT TO 4'-10"
5/8" MOISTURE RESISTANT GWB
RESTROOM SIDE
HALL SIDE
PARTITION
TYPE
STUD
WIDTH
3 5/8"
PARTITION
WIDTH
5 7/8"
STC
NA
NOTES
NONEC
SCALE:
NON-RATED STUD WALL
1 1/2" = 1'-0"
C
FULL HEIGHT WALL TILE
5/8" CEMENTITIOUS TILE BACKER BOARD
3 5/8"METAL STUDS @ 16" O.C.
WALL TILE WAINSCOT TO 4'-10"
5/8" MOISTURE RESISTANT GWB
CONT. WATERPROOF SHOWER MEMBRANE
RESTROOM SIDE
SHOWER SIDE
PARTITION
TYPE
STUD
WIDTH
3 5/8"
PARTITION
WIDTH
5 7/8"
STC
NA
NOTES
NONED
SCALE:
NON-RATED STUD WALL
1 1/2" = 1'-0"
D
FULL HEIGHT WALL TILE
5/8" CEMENTITIOUS TILE BACKER BOARD
3 5/8"METAL STUDS @ 16" O.C.
CONT. WATERPROOF SHOWER MEMBRANE
SHOWER SIDE
SHOWER SIDE
FULL HEIGHT WALL TILE
5/8" CEMENTITIOUS TILE BACKER BOARD
CONT. WATERPROOF SHOWER MEMBRANE
PARTITION
TYPE
STUD
WIDTH
NA
PARTITION
WIDTH
1 1/8"
STC
NA
NOTES
NONEE
SCALE:
NON-RATED WALL
1 1/2" = 1'-0"
E
EXISTING METAL STUD WALL
CONT. WATERPROOF SHOWER MEMBRANE
5/8" CEMENTITIOUS TILE BACKER BOARDSHOWER SIDE
OFFICE SIDE
FULL HEIGHT WALL TILE
PARTITION
TYPE
STUD
WIDTH
NA
PARTITION
WIDTH
1/2"
STC
NA
NOTES
NONEF
SCALE:
NON-RATED WALL
1 1/2" = 1'-0"
F
EXISTING METAL STUD WALL
NEW MOISTURE RESISTANT GWB WHERE
EXISTING GWB WAS REMOVED
RESTROOM SIDE
HALL SIDE
WALL TILE WAINSCOT TO 4'-10"
PARTITION
TYPE
STUD
WIDTH
3 5/8"
PARTITION
WIDTH
4 3/4"
STC
NA
NOTES
NONEG
SCALE:
NON-RATED STUD WALL
1 1/2" = 1'-0"
G
EXISTING EXTERIOR CMU AND BRICK WALL
3 5/8"METAL STUDS @ 16" O.C.
SHOWER SIDE
EXTERIOR
FULL HEIGHT WALL TILE
5/8" CEMENTITIOUS TILE BACKER BOARD
CONT. WATERPROOF SHOWER MEMBRANE
BATT INSULATION
RESTROOM SIDE
RESTROOM SIDE
PARTITION
TYPE
STUD
WIDTH
NA
PARTITION
WIDTH
5/8"
STC
NA
NOTES
NONEH
SCALE:
NON-RATED WALL
1 1/2" = 1'-0"
H
EXISTING WALL TYPE VARIES, SEE PLAN SHEET
RESTROOM SIDE
HALL SIDE
NEW 5/8" MOISTURE RESISTANT GWB
NEW WORK
EXISTING TO REMAIN
EXISTING / NEW WORK LEGEND
NEW CONCRETE
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
A-002
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
P A
R T
IT
IO
N T
Y P
E S
D
E T
A
IL
S
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
F A
-1
-D
-0
SCALE: 1 1/2" = 1'-0"
WALL TYPES
SCALE: 1 1/2"=1'-0"
GRAPHIC SCALE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
C
DA7 DA7
DA7
DA1
DA1
DA1
DA8
DA5DA2
DA5
DA9
DA10
DA9
DA9
DA11
DA9
DA5
DA5
DA6 DA3
DA12
DA10
DA4
DA4 DA4
DA4
DA6
DA6
DA6
DA6
DA6
DA14
DA14
DA15
+/- 19'-6"
+/- 5'-5"
DA13
DA13
DA13
DA13
DA13
DA13
EXISTING TO BE REMOVED.
EXISTING TO REMAIN
EXISTING / DEMOLITION LEGEND
EXISTING 2X4 LIGHT TO BE
REMOVED
EXISTING MECHANICAL
GRILL TO BE REMOVED
EXISTING EXHAUST FAN TO
BE REMOVED
1. RELOCATE FIRE PROTECTION SPRINKLER HEADS PER
NFPA 13.
GENERAL NOTES:
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
AD101
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
D E
M O
L
IT
IO
N
D E
T A
IL
S
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
F A
-1
-D
-0
SCALE: 1/2" = 1'-0"B1
DEMOLITION ENLARGED BATHROOM PLAN
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DA9 REMOVE & DISPOSE OF EXISTING FLOOR TILE
COMPLETE TO EXISTING CONCRETE FLOOR.
PREPARE FLOOR FOR NEW CERAMIC TILE
FLOOR.
DA10 REMOVE & DISPOSE OF EXISTING VCT
FLOORING COMPLETE. MASTIC PRESUMED TO
CONTAIN ASBESTOS. PREPARE FLOOR FOR
NEW CERAMIC TILE FLOOR.
DA11 REMOVE & DISPOSE OF EXISTING LOCKERS
DA12 REMOVE & DISPOSE OF EXISTING WINDOW.
PREPARE OPENING TO BE INFILLED.
DA13 REMOVE & DISPOSE OF EXISTING ACOUSTICAL
CEILING TILES AND GRID.
DA14 DEMOLISH EXISTING FLOOR DRAIN AND PATCH
EXISTING FLOOR PENETRATION.
DA15 PATCH ANY EXISTING FLOOR PENETRATIONS
WITHIN CHASE.
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DA1 DEMOLISH EXISTING METAL STUD AND GWB
WALL.
DA2 REMOVE & DISPOSE OF EXISTING VINYL WALL
COVERING AND GWB, WALL TO REMAIN.
DA3 REMOVE & DISPOSE OF EXISTING WALL TILE
AND GWB, WALL TO REMAIN.
DA4 REMOVE & DISPOSE OF EXISTING LAYER OF
GWB, WALL TO REMAIN.
DA5 REMOVE & DISPOSE OF EXISTING TOILET
PARTITION COMPLETE
DA6 REMOVE & DISPOSE OF EXISTING PLUMBING
FIXTURE
DA7 REMOVE & DISPOSE OF EXISTING DOOR AND
FRAME
DA8 DEMOLISH PORTION OF EXISTING METAL STUD
WALL FOR NEW DOOR AND FRAME
SCALE: 1/2" = 1'-0"B4
ENLARGED DEMOLITION RESTROOM RCP
AREA OF WORK
OPEN TO
HANGAR
BELOW
SECOND FLOOR
PLAN NORTH
1 2 42
SCALE: 1/2"=1'-0"
GRAPHIC SCALE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
A5A5
A6
A6
A6
A6
EXISTING LIGHT
TO REMAIN
A.F.F.8'-0"
C
C L E
A R
M
IN
/8
MIN.
3'-0" CLEAR
A-502
C1
C4
D1
D4
M
IN
C L E
A R
3' - 0"
3' - 0"
A-502B4 B1
3' - 6"
CLEAR
3' - 4 5/8" 1"
CLEAR
5' - 0"
4" 2' - 6" 4" 3' - 0"
/4
/8
C L E
A R
C L E
A R
8' - 7 1/4" 3' - 6" 7' - 0"
R 2'-6"
8' - 11"
A-501 B4
FA
B
B
C
C
C
D
E
G
E
F
A
F
2' - 8"
MATCH EXISTING
WALL CONSTRUCTION.
MATCH BRICK AND
MORTAR COLOR AS
CLOSE AS POSSIBLE
TO EXISTING.
A1 A2
A2
A4
H
H
G
EXISTING CMU AND
BRICK EXTERIOR WALL
EXISTING METAL STUD
WALL
EXISTING METAL STUD
WALL
EXISTING
METAL STUD
WALL
A7
A7
A8A8
CORNER TRIM AND
CORNER TOP
SUPPLIED BY LOCKER
MANUFACTURER
A9
A9
A9
A9
A3
A10
A10
A7
A7
3'-0"
1. SEE SHEET A-502 FOR FINISH SCHEDULE AND FIXTURE
MOUNTING HEIGHTS.
2. RELOCATE FIRE PROTECTION SPRINKLER HEADS PER
NFPA 13.
GENERAL NOTES:
NEW WORK
EXISTING TO REMAIN
EXISTING / NEW WORK LEGEND
NEW 2X4 LIGHT FIXTURE
NEW RECESSED LIGHT FIXTURE
NEW EXHAUST FAN
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
A-101
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
N E
W W
O R
K F
L O
O R
P L A
N
R E
F L E
C T
E D
C E
IL
I N
G P
L A
N
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
F A
-1
-D
-0
SCALE: 1/2" = 1'-0"B4
ENLARGED RESTROOM RCP
SCALE: 1/2" = 1'-0"B1
ENLARGED RESTROOM PLAN
PLAN NORTH
1 2 42
SCALE: 1/2"=1'-0"
GRAPHIC SCALE
NEW WORK KEYNOTES:
NO. DESCRIPTION
A1 NEW LAYER OF 5/8" MOISTURE RESISTANT GWB ON
EXISTING WALL.
A2 NEW LOCKERS WITH CORNER TRIM PIECE AND TOP.
SEE FINISH SCHEDULE FOR INFORMATION.
A3 NEW ADA COMPLIANT SINK AND VANITY.
A4 NEW LOCKER BENCH ATTACHED TO FLOOR.
A5 NEW 2X2 ACOUSTICAL CEILING TILES AND GRID.
A6 NEW MOISTURE RESISTANT GWB CEILING.
A7 NEW 2"x2" MOSAIC SHOWER TILE.
A8 NEW 12"x12" FLOOR TILE.
A9 NEW FLOOR DRAIN, SEE PLUMBING FOR MORE INFO.
A10 NEW ADA SHOWER SEAT, FOLD UP TYPE.
AREA OF WORK
OPEN TO
HANGAR
BELOW
SECOND FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
B1 A-501
WAINSCOT TILE TO 4'-10"
FULL HEIGHT WALL TILE
FULL HEIGHT WALL TILE
TO WRAP CORNER
A1 A-501
4" WIDE ADA SLOPED THRESHOLD
4" WIDE MARBLE THRESHOLD
4" WIDE MARBLE
THRESHOLD
4" WIDE ADA SLOPED THRESHOLD
THIN SET MOSAIC FLOOR TILE OVER
WATERPROOF SHOWER MEMBRANE
SLOPED TO DRAIN, 1/4" PER FOOT
THIN SET MOSAIC FLOOR TILE OVER
WATERPROOF SHOWER MEMBRANE
SLOPED TO DRAIN, 1/4" PER FOOT
THIN SET MOSAIC FLOOR TILE OVER
WATERPROOF SHOWER MEMBRANE
THIN SET MOSAIC FLOOR TILE OVER
WATERPROOF SHOWER MEMBRANE
12"X12" THIN SET FLOOR TILE
OVER EXISTING CONCRETE FLOOR
CONTINUOUS WATERPROOF
SHOWER MEMBRANE
CONTINUOUS WATERPROOF
SHOWER MEMBRANE
SECOND FLOOR
12'-0"
A1 A-501
4" WIDE X 3/4" TALL MARBLE THRESHOLD
FULL HEIGHT WALL TILE ON
OPENING JAMB
WALL TILE WAINSCOT BEYOND
THIN SET MOSAIC FLOOR TILE OVER
WATERPROOF SHOWER MEMBRANE
THIN SET 12"X12" FLOOR TILE OVER
EXISTING CONCRETE FLOOR
EXISTING WALL
5/8" CEMENTITIOUS TILE
BACKER BOARD
CONTINUOUS WATERPROOF
SHOWER MEMBRANE
ADA SLOPED
THRESHOLD BEYOND
THIN SET WALL TILE
FULL HEIGHT THIN SET
WALL TILE
MOISTURE RESISTANT GWB
CEILING ON METAL STUDS
WALL TILE AT HEAD OF OPENING
FULL HEIGHT THIN SET WALL TILE
5/8" CEMENTITIOUS TILE BACKER BOARD
5/8" MOISTURE RESISTANT GWB
ACOUSTICAL CEILING TILE AND GRID
ADA FOLD UP SHOWER SEAT
/2
M
A X
SLOPED ADA BARRIER FREE THRESHOLD
WATERPROOF SHOWER MEMBRANE
THIN SET FLOOR TILE
EXISTING CONCRETE SLAB
THIN SET FLOOR TILE SLOPED TO DRAIN
COLLAPSIBLE VINYL WATER DAM, ADA
FLOOR DRAIN,
SEE PLUMBING
MIN. 1/4" PER FT. SLOPED TO DRAIN
SLOPED FILL
CEMENTITIOUS TILE
BACKER BOARD
CONTINUOUS WATERPROOF
SHOWER MEMEBRANE
THIN SET WALL TILE
3 5/8" MTL. STUD WALL
EXISTING WALL
THIN SET FLOOR TILE
WATERPROOF SHOWER MEMBRANE
SLOPED FILL NEW WORK
EXISTING TO REMAIN
EXISTING / NEW WORK LEGEND
NEW CONCRETE
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
A-501
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
R E
S T
R O
O M
D E
T A
IL
S
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
F A
-1
-D
-0
PLAN NORTH
SCALE: 1 1/2"=1'-0"
GRAPHIC SCALES
SCALE: 1 1/2" = 1'-0"
A-101
B4
SHOWER ENTRY DETAIL
SCALE: 1 1/2" = 1'-0"
A-501
B1
SHOWER SECTION
SCALE: 3" = 1'-0"
A-501
A1
SHOWER DRAIN DETAIL
6"6"
SCALE: 3"=1'-0"
04 2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
PT-B1
PT-W1
PT-W2
TA-1
PNT-1
TA-2 TA-3
TA-1
TA-5
PT-W1
FULL HEIGHT
IN SHOWER
TA-4
TA-4
TA-8
B-1
L-1
TA-10
TA-11
PT-B1
PT-W1
PT-W2
TA-1
PNT-1
TA-3TA-2 PL-1
TA-4
TA-10
PT-B1
PT-W1
PT-W2
PNT-1
TA-7TA-6
TA-5
L-1PNT-1
B-1
ST-1
PNT-2
9"
PT-B1
PT-W1
PT-W2
PNT-1
TA-1
PNT-1 PL-1
TA-4
PT-B1
PT-W1
FULL HEIGHT
IN SHOWER
L-1
PNT-1
TA-9 B-1
TA-11
3'-0" MIN
TA-12
PT-B1
PT-W1
PT-W2
PNT-1
PT-B1
PT-W1
PT-W2
PNT-1
PT-B1
PT-W1
FULL
HEIGHT
IN
SHOWER
L-1
TA-8TA-8
B-1
TA-10
TA-11
WALL MOUNTED
MECHANICAL UNIT
TA-3
TA-2
TA-1
TA-3
TA-6
TA-5
1'-0" 3'-6"
M A
X
MAX.
3'-0"
M
IN
6" 3'-0"
M
IN
M A
X
/2
T O
R E
F L E
C T
IV
E
S U
R F
A C
E
M A
X
TA-2
M A
X
M
IN
MIN.
1'-3"
T O
S L O
T
TA-7
TA-8
TA-4
TA-9
1'-4"
5 1/2"
COMMENTS:
1. OR APPROVED EQUAL PRODUCT
2. SUBMIT MANUFACTURER'S STANDARD COLORS FOR SELECTION.
3. FURNISH AND INSTALL LAMINATE LOCKERS, END PANELS AND RELATED ITEMS. INCLUDE 4" BASE & PADLOCK HASP.
4. MOSAIC FLOOR TILE LOCATED IN SHOWER AREAS.
5. FURNISH AND INSTALL BLOCKING OR BACKER MATERIAL FOR ATTACHMENT/MOUNTING OF WALL HUNG ITEM OR
EQUIPMENT.
6. FURNISH AND INSTALL 2 PER SHOWER.
NEW WORK
EXISTING TO REMAIN
EXISTING / NEW WORK LEGEND
NEW CONCRETE
OR
AC
A N
C E
IT
CHAFIN
AR
HC
T
I L
OS
R G
IS
T
EDRE
E
UTH
KEVIN R.
F
O T
S A T E
N. Charleston, SC
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
J A
N U
A R
Y
N
E B
B
E B
B
C J H
M
B L D
G
A R
C H
Q J K
L
-0
A-502
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
K R
C
R E
S T
R O
O M
E L E
V A
T
IO
N S
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
F A
-1
-D
-0
1 2 42
SCALE: 1/2"=1'-0"
GRAPHIC SCALE
SCALE: 1/2" = 1'-0"
A-101
D1
ELEVATION A
SCALE: 1/2" = 1'-0"
A-101
D4
ELEVATION B
SCALE: 1/2" = 1'-0"
A-101
C1
ELEVATION C
SCALE: 1/2" = 1'-0"
A-101
C4
ELEVATION D
SCALE: 1/2" = 1'-0"
A-101
B1
ELEVATION E
SCALE: 1/2" = 1'-0"
A-101
B4
ELEVATION F
SCALE: NOT TO SCALEA1
STANDARD MOUNTING HEIGHTS
LEGEND OF COLORS AND FINISHES
MARK MATERIAL MANUFACTURER
PATTERN /
MODEL COLOR SIZE COMMENTS
BASE
PT-B1 PORCELAIN TILE BASE CROSSVILLE VISTA AMERICANA,
AV183
PLATEAU 6" X 12" 1
CEILING
ACG-1 ACOUSTICAL CEILING
TILE GRID
ARMSTRONG INTERLUDE XL
DIMENSIONAL TEE
WHITE 9/16" 1
ACT-1 ACOUSTICAL CEILING
TILE
ARMSTRONG ULTIMA
1902,TEGULAR
WHITE 2'-0" X 2'-0" 1
GWB-1 GYPSUM WALLBOARD --- --- PNT-1 --- ---
FLOORING
GR-1 FLOOR TILE GROUT LATICRETE SPECTRALOCK #35 MOCHA --- 1
PT-F1 PORCELAIN FLOOR TILE CROSSVILLE VISTA AMERICANA,
AV184
PALISADES 12" X 12" 1
PT-F2 PORCELAIN FLOOR TILE CROSSVILLE VISTA AMERICANA,
AV184
PALISADES 2"X2"
MOSAIC
1,4
MISC.
B-1 BENCH LENOX LENOXPEDESTAL CHARCOAL GRAY 36" LONG 1 (QTY:1)
L-1 LOCKERS LEGACY LOCKERS MODEL "A" WILSONART -
BURNISHED CHESTNUT
72"X12"X20" 1,3 (QTY:15)
PL-1 PLASTIC LAMINATE
(TOILET PARITIONS)
BOBRICK DURALINE SERIES
WILSONART -
BURNISHED CHESTNUT
--- 1
SS-2 SOLID SURFACE
(VANITIES TOPS)
CORIAN --- MATTERHORN 3'-0" X 2'-0" 1,5
ST-1 STAIN (WOOD DOORS) SHERWIN WILLIAMS --- BANISTER BEIGE
SW3128K
--- 1
TOILET ACCESSORIES
TA-1 TOILET TISSUE
DISPENSER
BOBRICK DOUBLE ROLL
B-27460
HEAVY DUTY CAST
ALUMINUM W/ SATIN
FINISH
--- 1,5 (QTY:2)
TA-2 36" GRAB BAR BOBRICK B-5806 STAINLESS STEEL W/
SNAP FLANGE
1 1/4" 1,5 (QTY:1)
TA-3 42" GRAB BAR BOBRICK B-5806 STAINLESS STEEL W/
SNAP FLANGE
1 1/4" 1,5 (QTY:1)
TA-4 SANITARY NAPKIN
DISPOSAL
BOBRICK SURFACE
MOUNTED, B-254
STAINLESS STEEL WITH
SATIN FINISH
1,5 (QTY:2)
TA-5 MIRROR BOBRICK B-1658 1830 TEMPERED GLASS,
CHANNEL FRAME
24"Wx36"H 1,5 (QTY:2)
TA-6 SOAP DISPENSER BOBRICK B-2111 STAINLESS STEEL WITH
SATIN FINISH
--- 1,5 (QTY:1)
TA-7 PAPER TOWEL
DISPENSER & WASTE
RECEPTACLE
BOBRICK CLASSIC B-3942 STAINLESS STEEL WITH
SATIN FINISH
1,5 (QTY:1)
TA-8 ROBE HOOK BOBRICK DOUBLE ROBE
HOOK B-6727
STAINLESS STEEL WITH
SATIN FINISH
1,5,6 (QTY:4)
TA-9 FOLDING SHOWER SEAT BOBRICK B-5191 STAINLESS STEEL WITH
SATIN FINISH
1,5 (QTY:2)
TA-10 SHOWER ROD, CURTAIN
& HOOKS
--- DECORATIVE
FABRIC
WHITE 7'-0" TALL
CURTAIN
(QTY:1)
TA-11 SHOWER ROD, CURTAIN
& HOOKS
--- DECORATIVE
FABRIC
WHITE 6'-0" TALL
CURTAIN
(QTY:2)
TA-12 SHOWER ROD, CURTAIN
& HOOKS
--- STANDARD VINYL
(SHOWER)
WHITE 6'-0" TALL
CURTAIN
(QTY:2)
WALLS
GR-2 WALL TILE GROUT LATICRETE SPECTRALOCK #56 DESERT KHAKI --- 1
PNT-1 WALL PAINT BENJAMIN MOORE --- LATEX SATIN --- 1,2
PNT-2 TRIM PAINT (DOOR
FRAMES)
BENJAMIN MOORE --- LATEX SATIN --- 1,2
PT-W1 PORCELAIN WALL TILE CROSSVILLE VISTA AMERICANA,
AV183
PLATEAU 6X18 1
PT-W2 PORCELAIN BULLNOSE
TILE
CROSSVILLE VISTA AMERICANA,
AV183
PLATEAU 4X12 1
MANUFACTURED WOOD
ADA VANITY WITH
PLASTIC LAMINATE TOP
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
LABOR, EQUIPMENT AND MATERIALS ARE TO BE PROVIDED TO COMPLETE THE
PLUMBING WORK INDICATED ON THESE DRAWINGS AS REQUIRED BY LOCAL CODE AND
ORDINANCES.
THE WORK SHALL INCLUDE WASTE, VENT, DOMESTIC COLD & HOT WATER PIPING, AS
INDICATED ON THESE DRAWINGS. ALSO, THE HOOKUP OF FIXTURES SCHEDULED AND
INSULATION OF PIPING SHALL BE INCLUDED.
ITEMS, SUCH AS FITTINGS, ETC. NOT MENTIONED BUT UNDERSTOOD TO BE NECESSARY
TO COMPLETE THE PLUMBING SYSTEM SHALL BE INCLUDED.
SOIL, WASTE, VENT AND WATER PIPING MATERIALS MUST MEET OR EXCEED LOCAL
CODES.
CLEAN OUTS FOR SOIL AND WASTE LINES AS SHOWN ON THE DRAWING MUST BE
PROVIDED AND MEET OR EXCEED LOCAL CODES.
STUBS FOR THE DRAINAGE SYSTEM MUST BE CAPPED UNTIL FINISHED WORK IS
INSTALLED.
WATER HAMMER ARRESTERS MUST BE PROVIDED IN ACCORDANCE WITH
INTERNATIONAL PLUMBING CODES AND LOCAL ORDINANCES.
TRAP PRIMER VALVES SHALL BE LOCATED BELOW THE FIXTURE INDICATED. PRIMER
LINES TO FLOOR DRAINS SHALL BE ROUTED DOWN INSIDE WALL AND BELOW SLAB.
SEE FLOOR PLANS AND RISER DIAGRAMS.
LOCATE PLUMBING FIXTURES PER ARCHITECTURAL DRAWINGS. PIPING IS SHOWN IN
GENERAL LOCATION. EXACT LOCATION WILL BE DETERMINED BY JOB CONDITIONS.
INSTALLATION SHALL BE PER PLANS AND SPECIFICATIONS AND STATE PLUMBING
CODE. SEE SPECIFICATIONS FOR PRODUCT AND INSTALLATION REQUIREMENTS.
COORDINATE LOCATION OF PLUMBING WORK WITH OTHER TRADES TO AVOID
CONFLICTS AND INTERFERENCES.
ALL EQUIPMENT, AND PIPE ABOVE CEILING SHALL BE SUPPORTED FROM BUILDING
STRUCTURE ABOVE, UNLESS OTHERWISE NOTED.
FLOOR DRAINS SHALL BE DEEP SEAL TRAP TYPE WITH 3/8" TRAP PRIMER CONNECTION
TO NEAREST CW SOURCE.
REMOVAL AND DISPOSAL OF FIXTURES, PIPING, ETC. IS TO INCLUDE ALL
ASSOCIATED HANGERS, SUPPORTS, BRACKETS, AND APPURTENANCES
PHYSICALLY ATTACHED AT THE COMMENCEMENT OF DEMOLITION, UNLESS
NOTED OTHERWISE.
LOCATIONS OF FIXTURES, PIPING, ETC. IS DIAGRAMMATIC ONLY AND IS NOT
INTENDED TO SHOW EXACT LOCATION.
WHERE FIXTURES OR PIPING IS REMOVED AND NOT REPLACED, PATCH AND
FINISH AREAS TO MATCH ADJACENT SURFACES.
GENERAL NEW WORK NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
GENERAL DEMOLITION NOTES:
1.
2.
3.
DETAILS ON THIS SHEET APPLY TO THE NEW WORK SHOWN ON SHEET P-401.
GENERAL DETAILS NOTE:
1.
VENT THROUGH ROOF
BRANCH ISOLATION VALVE
WALL CLEANOUT
SYMBOL
VENT PIPING
POINT OF CONNECTION BETWEEN NEW AND EXISTING
DOMESTIC HOT WATER, HW
DOMESTIC COLD WATER, CW
WASTE PIPING
EXISTING PIPING
TO BE REMOVED
WCO
FD FLOOR DRAIN
VTR
POINT OF DISCONNECTION BETWEEN EXISTING TO REMAIN AND EXISTING TO BE REMOVED
PIPE TURNING DOWN
PIPE TURNING UP
WCO WALL CLEAN OUT
P_ PLUMBING FIXTURE DESIGNATION
TYP. TYPICAL
(E) EXISTING
DWV DRAIN WASTE VENT
DN DOWN
W WASTE
V VENT
ADA AMERICANS WITH DISABILITIES ACT
CONNECTION
TRAP PRIMER
CLAMP COLLAR
FINISHED FLOOR
DEEP SEAL
"P" TRAP
STRAINER
TO DRAIN
SYSTEM
FLOOR DRAIN
FLOOR SLAB
5 LINES
1/2" TRAP PRIMER SUPPLY
1/2" TRAP PRIMER LINE
DOMESTIC WATER LINE
TRAP PRIMER VALVE
DISTRIBUTION UNIT, FOR
SLEEVE THRU SLAB
METAL CLEANOUT
3/8" THREADED ROD
SUPPORT FROM STRUCTURECLEVIS HANGER
(SIZE AS REQ'D)
INSULATION
SADDLE
INSULATED DUCT/PIPE
INSULATION
FIRE STOPPING SEALANT
DUCT/PIPING SLEEVE
FIRE STOPPING SEALANT
CONC. BLOCK WALL
NOTE: FIRESTOPPING
ASSEMBLY SHALL COMPLY
WITH UL WL-1041
INSULATED PIPE
18 GAUGE ROUND
GALVANIZED STEEL
CLEANOUT PIPE
WALL CLEANOUT
FINISHED WALL
ACCESS COVER
No. 23532
S
OU
TH
CAROL IN
A
R E G I S T E R E D
PR
OFESS I ONA
L E N G
I N E E R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
N
J R
C
J R
C
P C
M
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
J R
C
G E
N E
R A
L N
O T
E S
L E
G E
N D
S
D E
T A
IL
S
A
N D
S C
H E
D U
L E
F A
-1
-D
-0
P-001
J A
N U
A R
Y
Q J K
L
-0
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
PLUMBING FIXTURE SCHEDULE
SYM. FIXTURE
PIPE SIZES
REMARKSC.W. H.W. DRAIN VENT
P-1 WATER CLOSET -
ADA
1" 3" 2" SEE SPECIFICATIONS
P-2 COUNTERTOP
LAVATORY - ADA
1/2" 1/2" 1 1/4" 1 1/4" SEE SPECIFICATIONS
P-3 SHOWER - ADA 1/2" 1/2" 2" 2" SEE SPECIFICATIONS
P-4 FLOOR DRAIN 2" 2" SEE SPECIFICATIONS
SCALE: NOT TO SCALEA1
TYPICAL FLOOR DRAIN DETAIL
SCALE: NOT TO SCALEA2
TRAP SEAL PRIMER DETAIL
SCALE: NOT TO SCALEA3
TYPICAL PIPE SUPPORT DETAIL
SCALE: NOT TO SCALEA5
FIRE STOPPING PIPE PENETRATIONS
SCALE: NOT TO SCALEB1
WALL CLEANOUT DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
BUILDING CW
SERVICE
P2
P2
P2P2
1 1/2" HW
1 1/2" CW
2" CW
1" HW
1" HW UP
1 1/2" CW UP
1 1/2" CW
P3
P3
P-1
P-1
P-3 P-3
P-2
WCO
WCO3" SS
2" SS2" SS
3" SS
3" DN
1 1/4" SS
1 1/4"
VENT UP
2" VENT UP2" VENT UP2" VENT UP
P3 P3 P3
P1
1/2" HW
1/2" CW
1/2" HW
1 1/4" CW
1 1/4" CW
1/2" CW
1 1/4" CW
1" CW
1" HW
1/2" CW
1/2" HW
P4
P4
2" SS
P-4
P-4
2" SS
2" SS
P5
VTR
CO
DP2
DP2
DP1
DP1
DP1
BUILDING CW
SERVICE
DP1
HW
CW
No. 23532
S
OU
TH
CAROL IN
A
R E G I S T E R E D
PR
OFESS I ONA
L E N G
I N E E R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
/4
N
J R
C
J R
C
P C
M
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
J R
C
P L U
M B
IN
G
E N
L A
R G
E D
P L A
N S
F A
-1
-D
-0
P-401
J A
N U
A R
Y
Q J K
L
-0
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
NEW WORK KEYNOTES:
NO. DESCRIPTION
P1 FURNISH AND INSTALL NEW PLUMBING
FIXTURES AS SHOWN.
P2 FURNISH AND INSTALL NEW PIPING AS SHOWN,
REATTACHING TO EXISTING PIPING AND WATER
HEATER.
P3 RECONNECT DWV PIPING TO EXISTING DWV
STACKS AND VENT THROUGH ROOF.
P4 PRIOR TO PIPING INSTALLATION, THE
CONTRACTOR SHALL INSPECT AREAS TO RUN
PIPING BENEATH THE SLAB AS THERE IS
EXISTING ELECTRICAL CONDUIT AND
EQUIPMENT THAT MUST REMAIN.
P5 3"SS LOCATED IN FIRST FLOOR CEILING.
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
GRAPHIC SCALE
PLAN NORTH
SCALE: 1/4" = 1'-0"B3
FIRST FLOOR PLUMBING NEW WORK PLAN
SCALE: 1/4" = 1'-0"A3
SECOND FLOOR PLUMBING NEW WORK PLAN
SCALE: 1/4" = 1'-0"A1
SECOND FLOOR PLUMBING DEMOLITION PLAN
SCALE: 1/4" = 1'-0"B1
FIRST FLOOR PLUMBING DEMOLITION PLAN
AREA OF WORK
OPEN TO
HANGAR
BELOW
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DP1 REMOVE AND DISPOSE OF EXISTING CW & HW
PIPING AS SHOWN AND PREPARE
DISCONNECTIONS FOR CONNECTION TO NEW.
DP2 REMOVE AND DISPOSE OF EXISTING PLUMBING
FIXTURES AS SHOWN, ALONG WITH ALL
ASSOCATED DWV AND SUPPLY PIPING.
PREPARE EXISTING WASTE DOWN AND VENT
THROUGH ROOF FOR REATTACHMENT TO NEW
DWV PIPING.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
LEGEND:
TO BE REMOVED/DEMOLISHED
SPIN-IN W/DAMPER (45° OR 90° TAP)
DIRECTION OF FLOW
DIRECTION OF AIRFLOW
FLEXIBLE DUCT-MAX. 8' LONG
SEE SCHEDULE FOR SIZES
MANUAL VOLUME DAMPER
POINT OF CONNECTION
BETWEEN NEW AND EXISTING
POINT OF DISCONNETION BETWEEN EXISTING
TO REMAIN AND EXISTING TO BE REMOVED
EXHAUST AIRE/A
MOTOR OPERATED DAMPERMOD
X ### AIR DISTRIBUTION MARK, SEE SCHEDULE M-001
EXHAUST FANEF
HEATERH
EXHAUST GRILLE
DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT TO
BE SCALED FOR DIMENSIONS, UNLESS DIMENSIONED.
COORDINATE LOCATION OF MECHANICAL WORK WITH OTHER
TRADES TO AVOID CONFLICTS AND INTERFERENCES.
ALL EQUIPMENT, PIPE AND DUCTWORK SHALL BE INSTALLED
ABOVE CEILING STRUCTURE, UNLESS OTHERWISE NOTED.
DUCTWORK SHALL BE GALVANIZED STEEL FABRICATED AND
INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS.
DUCT SIZES INDICATED ARE NET FREE INSIDE DIMENSIONS.
GENERAL NEW WORK NOTES:
1.
2.
3.
4.
5.
REMOVAL OF EQUIPMENT, DUCTWORK, PIPING ETC. IS TO
INCLUDE ALL ASSOCIATED HANGERS, SUPPORTS, BRACKETS,
CONTROLS, AIR DEVICES, EQUIPMENT
FOUNDATION/MOUNTING PADS AND APPURTENANCES
PHYSICALLY ATTACHED AT THE COMMENCEMENT OF
DEMOLITION, UNLESS NOTED OTHERWISE.
ALL EQUIPMENT REMOVED, NOT INDICATED TO BE REUSED
SHALL BECOME THE PROPERTY OF THE CONTRACTOR,
UNLESS NOTED OTHERWISE, AND SHALL BE TRANSPORTED
BY THE CONTRACTOR OFF SITE.
EXISTING EQUIPMENT INDICATED TO BE REUSED SHALL BE
CLEANED AND SERVICED PRIOR TO REUSE.
WHERE EQUIPMENT, DUCTWORK OR PIPING IS REMOVED
AND NOT REPLACED, PATCH AND FINISH AREAS TO MATCH
ADJACENT SURFACES.
SEE ENLARGED PLANS FOR EQUIPMENT REMOVAL.
GENERAL DEMOLITION NOTES:
1.
2.
3.
4.
5.
DETAILS ON THIS SHEET APPLY TO THE NEW WORK SHOWN
ON SHEET M-401.
GENERAL DETAIL NOTES:
1.
NOTES:
1. PROVIDE SINGLE POINT CONNECTION
NOTES:
1. PROVIDE SINGLE POINT CONNECTION.
2. SHALL BE CAPABLE OF INTERFACING WITH WALL
MOUNTED THERMOSTAT.
NOTES:
A LIMITED AMOUNT OF AVAILABLE CEILING AREA MAY REQUIRE THE CEILING BE CUT TO ACCOMMODATE A SMALL GRILLE FACE IN LAY-IN AS WELL AS SURFACE MOUNT. CONTRACTOR IS RESPONSIBLE FOR VERIFYING
CEILING TYPE AND AVAILABLE SPACE WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS.
AIR DISTRIBUTION DESIGN WAS BASED ON PRICE FOR REFERENCE ONLY. AIR DISTRIBUTION BY NAILOR, TITUS, KRUEGER, METAL AIRE OR CARNES ACCEPTABLE UPON APPROVAL.
AIR DISTRIBUTION CALL-OUT X ###
MARK CFM
1.
2.
3.
NOTES:
A LIMITED AMOUNT OF AVAILABLE CEILING AREA MAY REQUIRE THE CEILING BE CUT TO ACCOMMODATE A SMALL GRILLE FACE IN LAY-IN AS WELL AS SURFACE MOUNT. CONTRACTOR IS RESPONSIBLE FOR VERIFYING
CEILING TYPE AND AVAILABLE SPACE WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS.
AIR DISTRIBUTION DESIGN WAS BASED ON PRICE FOR REFERENCE ONLY. AIR DISTRIBUTION BY NAILOR, TITUS, KRUEGER, METAL AIRE OR CARNES ACCEPTABLE UPON APPROVAL.
AIR DISTRIBUTION CALL-OUT X ###
MARK CFM
1.
2.
3.
NOTES:
1. PROVIDE WITH SINGLE POINT POWER CONNECTION.
2. FAN SECTIONS SHALL BE FACTORY PROVIDED WITH INTERNAL VIBRATION ISOLATION.
3. CAPACITIES SHOWN ARE NOMINAL VALUES.
4. PROVIDE AHU WITH INTERNAL FLOAT SWITCH CONTROLLING UNIT SHUT DOWN UPON
HIGH CONDENSATE LEVELS IN INTERNAL DRIP PAN.
SUPPORT FROM
STRUCTURE ABOVE
FLEXIBLE
CONNECTION
VIBRATION ISOLATORS,
SEE SPECIFICATIONS
AIR
FLOW
WALL MOUNT SLEEVE
LOUVER
BIRDSCREEN
FAN
HOUSING
BOLT ON 4" CENTERS
1" FLANGE AND HEM
1" x 1/8" BAND IRON
RUBBER
IMPREGNATED
FABRIC
20 US GUAGE STEEL
ALTERNATE
POSITION OF BOLT
DUCT
1-1/2" POCKET SLIP
FLASH RAIL INTO
EXISTING ROOF
EXISTING
MEMBRANE ROOF
NOTE:
CONTRACTOR SHALL
ENSURE THE EXISTING
ROOF BOND/WARRANTY
WITH CARLISLE BUILDING
PRODUCTS IS MAINTAINED
EQUIPMENT MOUNTING
RAIL (INSULATED)
NEOPRENE PAD AT
CORNERS OF UNIT,
BOLT UNIT TO RAILS
(TYP. OF 4 PLACES)
HEAT PUMP
SUPPORT FROM STRUCTURE
TO MINIMIZE SAGGING
SUSPENDED CEILING
No. 23532
S
OU
TH
CAROL IN
A
R E G I S T E R E D
PR
OFESS I ONA
L E N G
I N E E R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
A s i n d ic a te d
N
J R
C
J R
C
P C
M
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
J R
C
G E
N E
R A
L N
O T
E S
L E
G E
N D
S
D E
T A
IL
S
A N
D S
C H
E D
U L E
S
F A
-1
-D
-0
M-001
J A
N U
A R
Y
Q J K
L
-0
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
EXHAUST FAN SCHEDULE
MARK TYPE
AREA
SERVED
TOTAL
CFM
SP. IN.
WATER FAN RPM MOTOR V/Ø/HZ MANUFACTURER MODEL
EF-1 INLINE DIRECT DRIVE RESTROOM 200 .30" 1550 1/30 HP 115/1/60 GREENHECK SQ-70-D
WALL HEATER SCHEDULE
MARK HEATING KW V/Ø/HZ
WH-1 1.0 120/1/60
WH-2 1.0 120/1/60
LEAKAGE CLASS
RECTANGULAR
METAL
24 12 6
ROUND METAL 12 6 3
DALT (DUCT AIR LEAKAGE TEST)
APPLICABLE LEAKAGE CLASSES
DUCT CLASS 1/2", 1", 2" W.G. 3" W.G. 4", 6", 10" W.G.
SEAL CLASS A A A
SEALING
APPLICABLE
TRANSVERSE
JOINTS ONLY
TRANSVERSE
JOINTS AND
SEAMS
JOINTS, SEAMS
AND ALL WALL
PENETRATIONS
AIR DISTRIBUTION SCHEDULE
TAG DESCRIPTION MATERIAL FINISH
FACE AND
NECK SIZE
MAX
NC FACE STYLE
FACE BLADE ARRANGEMENT
(GRILLES & REGISTERS ONLY) MOUNTING
PATTERN
(DIFFUSERS ONLY) DAMPERS
A EXHAUST GRILLE ALUM. WHITE 12 x 12 FACE
- 6 x 6 NECK
30 SQUARE FIXED 30° BLADE LAY-IN N/A N/A
AIR HANDLING UNIT SCHEDULE
INDOOR SECTION
COOLING CAPACITIES @95F
AMBIENT AIR (BTUH) HEATING
CAPACITY
(BTUH) V/Ø/HZ
REFRIGERANT
TYPETAG MFTR MODEL
TOTAL
CFM O.A. CFM AIR ENTR. RATED SEER
AHU-1 DAIKIN AC
(AMERICAS), INC.
FTXG09HVJU 230 0 80/67 9,000 26.1 12,000 208/1/60 R-410A
HP-1 DAIKIN AC
(AMERICAS), INC.
RXG09HV JU - - - - - - 9,000 26.1 12,000 208/1/60 R-410A
SCALE: NOT TO SCALEA1
INLINE EXHAUST FAN (LOUVER)
SCALE: NOT TO SCALEA4
TYP. FLEXIBLE CONNECTION
SCALE: NOT TO SCALEB1
ROOF MOUNTED HEAT PUMP DETAIL
SCALE: NOT TO SCALEA3
TYP. DIFUSER DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
DM2
DM2
DM1
DM1
A 100
8x8 EA
M1
EF-1 MOD
M4
M1
A 1006 x E
A x E
A
T
WH-2
A H
U -1
WH-2
WH-1
M5
M5
M3
M2
T
WH-1
SEQUENCE OF OPERATION:
EXHAUST FAN:
EXHAUST FAN SHALL BE CONTROLLED BY BUILDING OCCUPANCY SCHEDULE.
DURING OCCUPIED HOURS THE EXHAUST FAN SHALL BE ENERGIZED, DURING UNOCCUPIED HOURS THE EXHAUST FAN SHALL BE DE-ENERGIZED.
THE ASSOCIATED MOTOR OPERATED DAMPER SHALL OPEN PRIOR TO THE EXHAUST FAN ENERGIZING, AND SHALL CLOSE WHEN EXHAUST FAN IS DE-ENERGIZED.
AIR HANDLING UNIT AND HEAT PUMP:
A PROGRAMMABLE CONTROLLER CAPABLE OF STANDALONE OPERATION WILL CONTROL THE AIR HANDLER AND HEAT PUMP, SUBJECT TO OCCUPANCY SCHEDULES THROUGH THE EXISTING SUPERVISORY BUILDING CONTROLLER (SBC).
IN THE OCCUPIED MODE THE UNIT SHALL MAINTAIN 78°F IN COOLING MODE AND 68°F IN HEATING MODE. SPACE TEMPERATURE SHALL BE CONTROLLED BY THE SBC, THERMOSTATS IN RESPECTIVE CONDITIONED SPACES TO PROVIDE 1 HOUR TEMPORARY OVERRIDE CAPABILITIES. UPON A CALL FOR HEATING OR COOLING, THE FAN SPEED SHALL BE CONTROLLED BY THE UNIT, AND THE UNIT SHALL BE FULLY OPERATIONAL PER THE UNIT’S INTERNAL CONTROLS.
IN UNOCCUPIED MODE THE UNIT SHALL MAINTAIN 83°F IN COOLING MODE AND 55°F IN HEATING MODE.
WHEN OPERATING STATUS OF UNIT IS NOT PROVEN THE CONTROLLER SHALL DE-ENERGIZE THE UNIT AND AN ALARM SHALL BE DISPLAYED AT THE OPERATOR'S WORKSTATION.
AHU-1/HP-1 SHALL BE PROGRAMMED TO OPERATE IN CONJUNCTION WITH WALL HEATERS WH-1/2, SUCH THAT THE HEATING FROM AHU-1/HP-1 IS THE PRIMARY SOURCE OF HEAT FOR THE SPACE, AND THE WALL HEATERS ACT AS A BACK UP EMERGENCY
HEAT IN THE EVENT THAT AHU-1/HP-1 CANNOT HANDLE THE FULL HEATING LOAD.
WALL HEATERS:
THE WALL HEATERS WILL BE CONTROLLED THROUGH A STANDALONE PROGRAMMABLE TERMINAL CONTROLLER TIED TO THE EXISTING SUPERVISORY BUILDING CONTROLLER.
THE WALL HEATER CONTROLLER SHALL BE PROGRAMMED FOR A HEATING SPACE SETPOINT OF 68°F DURING OCCUPIED HOURS, AND 55°F DURING UNOCCUPIED HOURS. THE THERMOSTAT SHALL HAVE FULL COMMUNICATION WITH THE EXISTING SUPERVISORY BUILDING CONTROLLER. THE PROGRAM FOR THE WALL HEATER CONTROLLER WILL RESIDE IN MEMORY AND WILL NOT BE AFFECTED BY LOSS OF POWER TO THE CONTROLLER ONCE POWER IS RESTORED.
THERMOSTAT TO BE PROVIDED WITH 1 HOUR MANUAL OVERRIDE SWITCH. UPON ACTIVATION OF OVERRIDE SWITCH THE SET POINT TEMPERATURE SHOULD BE 68°F.
THE WALL HEATERS SHALL BE PROGRAMMED TO OPERATE IN CONJUNCTION WITH AHU-1/HP-1, SUCH THAT THE HEATING FROM AHU-1/HP-1 IS THE PRIMARY SOURCE OF HEAT FOR THE SPACE, AND THE WALL HEATERS ACT AS A BACK UP EMERGENCY HEAT
IN THE EVENT THAT AHU-1/HP-1 CANNOT HANDLE THE FULL HEATING LOAD.
WHEN OPERATING STATUS OF UNIT IS NOT PROVEN THE CONTROLLER SHALL DE-ENERGIZE THE UNIT AND AN ALARM SHALL BE DISPLAYED AT THE OPERATOR'S WORKSTATION.
HVAC EMERGENCY SHUTDOWN SWITCH:
THE EXISTING HVAC EMERGENCY SHUTDOWN SWITCH AND SEQUENCE AT BUILDING 821 SHALL INTERFACE WITH AND DE-ENERGIZE THE EXHAUST FAN AND SHALL CLOSE THE EXHAUST SYSTEM MOTOR OPERATED DAMPER. THE WALL HEATERS AND SPLIT
SYSTEM HEAT PUMP SHALL REMAIN IN OPERATION.
No. 23532
S
OU
TH
CAROL IN
A
R E G I S T E R E D
PR
OFESS I ONA
L E N G
I N E E R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
T A
S K
O R
D E
R N
U M
B E
R
T
H A
IR
L
IF
T
W
IN
G
C K
D B
Y x
C
P R
O J E
C T
N U
M B
E R
P
L O
T S
C A
L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i ve
L a d s o n
S o u th
C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
M
P ro je c t
M a n a g e r:
C H
R
IS
H
IN
S O
N
21 4 5
D
B
A
C O
N T
R A
C T
N U
M B
E R
1/7/15
/7
/1
/4
N
J R
C
J R
C
P C
M
M P
L S
-S T
P
A U
L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
IL
IT
A R
Y H
IG
H
W A
Y M
IN
N
E A
P O
L
IS
M
N
-2
J R
C
M E
C H
A N
IC
A
L E
N L A
R G
E D
P L A
N S
F A
-1
-D
-0
M-401
J A
N U
A R
Y
Q J K
L
-0
R E
P A
IR
W
O M
E N
'S R
E S
T R
O O
M
B U
IL
D
IN
G
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
GRAPHIC SCALE
PLAN NORTH
NEW WORK KEYNOTES:
NO. DESCRIPTION
M1 REINSTALL SAVED FLEX DUCT AND SUPPLY
DIFFUSER AS SHOWN.
M2 FURNISH AND INSTALL NEW 24x12 EXHAUST
LOUVER.
M3 FURNISH AND INSTALL AHU-1 ON WALL
BETWEEN TOP OF LOCKERS AND THE CEILING.
ASSOCIATED HP-1 TO BE FURNISHED AND
INSTALLED DIRECTLY ABOVE AHU-1 ON THE
FLAT ROOF. CONDENSATE FROM AHU-1 SHALL
BE ROUTED TO FLOOR DRAIN IN MECHANICAL
ROOM BENEATH THE STAIRS. SEE DETAIL B1 ON
SHEET M-001. CONTRACTOR SHALL ENSURE
THE EXISTING ROOF BOND/WARRANTY WITH
CARLISLE BUILDING PRODUCTS IS MAINTAINED.
M4 FURNISH AND INSTALL NEW LOW LEAKAGE
MOTOR OPERATED DAMPER.
M5 WALL HEATERS TO BE MOUNTED IN THE WALLS
PER MANUFACTURER'S RECOMMENDATIONS.
BOTTOM OF WALL HEATER SHALL BE NO
GREATER THAN 24" ABOVE FINISHED FLOOR.
SCALE: 1/4" = 1'-0"B1
MECHANICAL SECOND FLOOR DEMOLITION ENLARGED PLAN
SCALE: 1/4" = 1'-0"B3
MECHANICAL SECOND FLOOR NEW WORK ENLARGED PLAN
AREA OF WORK
OPEN TO
HANGAR
BELOW
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DM1 REMOVE AND DISPOSE OF EXISTING EXHAUST
FANS, DUCTS, LOUVER, AND ALL RELATED
APPURTENANCES COMPLETE.
DM2 REMOVE AND DISPOSE OF DUCTWORK AND
SUPPLY DIFFUSER AS SHOWN. SUPPLY
DIFFUSER AND FLEX DUCT TO BE SAVED FOR
REUSE IN NEW WORK.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
GENERAL ELECTRICAL NOTES (APPLIES TO ALL DRAWINGS):
1. ALL ELECTRICAL WORK IS TO BE DONE IN ACCORDANCE WITH THE CURRENT
EDITION OF NFPA 70: NATIONAL ELECTRICAL CODE.
MATERIALS ARE TO BE NEW AND CONFORM TO THE STANDARDS OF THE
UNDERWRITER'S LABORATORIES, INC. (U.L.) AND THE NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION (NEMA).
CONTRACTOR SHALL CONSIDER VOLTAGE DROP WHEN DETERMINING THE
EXACT ROUTING OF BRANCH CIRCUIT AND FEEDER WIRING. ADJUST WIRE AND
CONDUIT SIZE AS NECESSARY TO PREVENT A VOLTAGE DROP EXCEEDING 3%
AT THE FURTHEST DEVICE LOCATION.
ALL PENETRATIONS THROUGH FIRE RATED WALLS, AND SMOKE PARTITIONS
SHALL BE SEALED WITH AN APPROVED FIRE PROOFING SEALANT OR U.L.
LISTED PENETRATION DEVICE.
ELECTRICAL DRAWING IS GENERALLY DIAGRAMMATIC. COORDINATE WORK
WITH ALL TRADES PRIOR TO START OF CONSTUCTION. BRANCH CIRCUIT
CONDUIT ROUTING SHALL BE COORDINATED IN THE FIELD BY THE CONTRACTOR
TO MEET SPECIFICATIONS, CODE REQUIREMENTS, AND TO PROVIDE A NEAT,
WORKMAN LIKE, FULLY OPERATIONAL SYSTEM.
PROVIDE A TYPED SCHEDULE IN PANELBOARDS CLEARLY DESCRIBING THE
LOCATION AND TYPE OF LOAD BEING SERVED FOR ALL CIRCUITS.
CONTRACTOR IS TO BE AWARE OF ALLL RULES, REGULATIONS, AND CODES
REQUIRED FOR SUCCESSFUL COMPLETION OF CONSTRUCTION.
COORDINATE WITH THE MECHANICAL PLANS FOR THE EXACT LOCATION OF ALL
MECHANICAL EQUIPMENT BEFORE ROUGHING IN. ALL MECHANICAL EQUIPMENT
SHALL BE ROUGHED IN AND WIRED ACCORDING TO THE SHOP DRAWINGS.
2.
3.
4.
5.
6.
7.
8.
LEGEND:
RECEPTACLE, 20A, 120VOLT ('G' -…
This is the start of the file's text. The full file is on GovTribe.