ASHE_16-1033_CEBD.xls

XLS spreadsheet 352 KB Posted

Attached to
RENOVATION FAC 1380 FOR 606 ACS BED DOWN, AVIANO AB
Solicitation number
FA5682-16-R-0028
Issued by

About this file

ASHE 16-1033 CONSTRUCTION COST ESTIMATE BREAKDOWN R

View the file

Other files

File Type Posted
ASHE_16-1033_FAC_1380_TS_ENG_R.pdf PDF
FA5682-16-R-0028-0001.pdf PDF
ADDITIONAL_REQUIREMENTS.pdf PDF
BUILDING_ACCEPTANCE_CHECKLIST-_FIRE_DEPT.pdf PDF
FA5682-16-R-0028.pdf PDF
ASHE_16-1033_CEBD_MDT.xls XLS spreadsheet
Drawings_ASHE_16-1033.pdf PDF
Master_Technical_Specs_Nov_2005_English.zip ZIP file
2489_ASHE_16-1033_FAC_1380_TS_ENG_100__MDT.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

repair

CONSTRUCTION COST ESTIMATE BREAKDOWN R
ASHE 16-1033 - RENOVATE FAC.1380 FOR 606 ACS BED DOWNADDRESS
INSTRUCTIONS FOR COMPLETING FORMPROPOSED TOTAL CONTRACT PRICE
RENOVATE FAC.1380 FOR 606 ACS BED DOWN
PURCHASE REQUEST NUMBERPROJECT NUMBERWORK LOCATION
ASHE 16-1033AREA F, AVIANO AIR BASE, ITALY
MATERIAL COSTSLABOR COSTS
LINE NO.ITEMUNIT OF MEASUREQUANTITYUNITTOTALMANHOURS MANDAYSAVERAGE RATETOTALOTHER DIRECT COSTSLINE TOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
B.REPAIR WORK / Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni
Ia Architectural Work - Ia Lavori Architettonici
1REMOVAL OF INTERIOR WOOD DOORS
Rimozione di porte in legno interneIT. No. Art. n.1Ea,/No.
2DEMOLITION OF MASONRY PARTITIONS
Demolizione di tramezzi in muraturaIT. No. Art. n.2m2
3SURVEYED DEMOLITION OF EXTERIOR WALL
Demolizione controllata di muratura esternaIT. No. Art. n.3m2
4REMOVAL OF INTERIOR SECTIONAL DOORS
Rimozione di portoniIT. No. Art. n.4m2
Total Architectural Work - Totale Lavori Architettonici
Ib Structural Work - Ib Lavori Strutturali
NOT APPLICABLE

Non applicabile

Ic Civil Work - Ic Lavori Civili
NOT APPLICABLE

Non applicabile

Total Civil Work - Totale Lavori Civili
Id Mechanical Work- Id Lavori Meccanici
5REMOVAL OF EXISTING AHU
Rimozione UTA esistenteIT. No. Art. n.1Ls/Ac
6REMOVAL OF EXISTING AIR DUCTS
Rimozione canali dell'ariaIT. No. Art. n.2Ls/Ac
7REMOVAL OF EXISTING PUMPS AHU
Rimozione pompe esistenti UTAIT. No. Art. n.3Ls/Ac
8REMOVAL OF EXISTING ROOM THERMOSTAT
Rimozione termostati ambiente esistentiIT. No. Art. n.4Ea/No.
9REMOVAL OF CHILLER EXISTING
Rimozione gruppo frigo esistenteIT. No. Art. n.5Ls/Ac
10REMOVAL OF UNIT EXISTING HEATERS
Rimozione aerotermo esistenteIT. No. Art. n.6Ls/Ac
11REMOVAL OF EXISTING SPRINKLER HEADS
Rimozione erogatore sprinkler7Ls/Ac
12REMOVAL OF EXISTING WET SYSTEM VALVE ASSEMBLIES
Rimozione sistema di valvole impianto a umido esistenteIT. No. Art. n.8Ls/Ac
13REMOVAL OF EXISTING WATER CLOSET
Rimozione vaso igienico esitenteIT. No. Art. n.9Ls/Ac
Total hvac and plumging removal - Totale rimozionee impianti idrici e hvac
Ie Electrical Work - Ie Lavori Elettrici
14REMOVE AND DEMOLITION EXISTING ELECTRYCAL SYSTEM ( ELECTRYCAL SYSTEM NOT USED)
Rimuovere e demolire impianto elettrico esistente (non più utilizzato)IT. No. Art. n.1LS/AC
Total Electrical Work - Totale Lavori Elettrici
TOTAL PART I / Totale Parte I
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte II - Lavori Architettonici, Strutturali e Civili
IIa Architectural Work - IIa Lavori Architettonici
1513cm GYPSUM BOARD PARTITIONS
Nuovi tramezzi in cartongesso, spessore 13cmIT. No. Art. n.1mq
16STEEL LINTELS
Architravi in acciaioIT. No. Art. n.2Ea/No.
17PAINTING AND REPAIR OF INTERIOR WALLS
Ripristino e tinteggiatura di pareti interneIT. No. Art. n.3mq
18100x210 Cm, WOOD INTERIOR DOORS, SYMBOL D1
Porte interne in legno, 100x210 cm, sigla D1IT. No. Art. n.4Ea/No.
19MOISTURE-PROOF MINERAL FIBER PANEL SUSP. FIRE RATED CEILING
Controsoffitto resistente al fuoco in pannelli di fibra mineraleIT. No. Art. n.5mq
20WOOD BASEBOARD
Zoccolino battiscopa di legnoIT. No. Art. n.6m
21ROOF CHECK REPAIR
CONTROLLO E RIPRISTINO COPERTURAIT. No. Art. n.7mq
22PAINTING OF EXTERIOR WALLS
Tinteggiatura di pareti esterneIT. No. Art. n.8mq
23120x120 cm ALUMINUM WINDOWS, SYMBOL "F1"
Finestre in alluminio, 120x120 cm, sigla "F1"IT. No. Art. n.9Ea/No.
24CLOSING OF ROOMS, HOLES AND NEW BRICK SIDES IN CLAY BRICKS
Chiusura foro muroIT. No. Art. n.10mq
25METAL GRILL BOX
Griglie metalliche per BoxIT. No. Art. n.11mq
26SECTIONAL DOOR
Portone sezionaleIT. No. Art. n.12Ea/No.
27THERMAL-ACOUSTICAL INSULATION PANELS FOR

PERIMETER WALLS - REI 120

Pannelli per isolamento termo-acustico per pareti perimetrali - REI 120IT. No. Art. n.13mq
Total Architectural Work - Totale Lavori Architettonici0.000.000.000.00
IIb Structural Work - IIb Lavori Strutturali
28STRUCTURE STEEL
Strutture in acciaioIT. No. Art. n.1kg
29FLOOR WITH MIXED STEEL-CLS GALVANIZED TYPE A55 / P 600
Solaio misto acciaio-cls con lamiera zincata tipo a 55/p 600IT. No. Art. n.2mq
30SUPPLY AND INSTALLATION OF TYPE ELECTROWELDED B450C
Fornitura e posa di rete elettrosaldata tipo B450CIT. No. Art. n.3Akg
31ROD STEEL TYPE B450C
Tondino di acciaio tipo B450CIT. No. Art. n.3Bkg
IIc Civil Work - IIc Lavori Civili
NOT APPLICABLE/Non applicabile
TOTAL PART II / Totale Parte II0.000.000.000.00
PART III - MECHANICAL WORK / Parte III - Lavori Meccanici
32CLEANING OF EXISTING AIR DUCTWORKS.
Pulizia delle canalizzazioni dell'ariaIT. No. Art. n.1Ls/Ac
33REPAIR OR REPLACE DAMGED MECHANICAL EQUIPMENT
Riparare o sotituire apparecchiatura meccanica danneggiataIT. No. Art. n.2Ls/Ac
34SUPPLY AND INSTALLATION OF AHU
Fornitura e posa in opera di UTAIT. No. Art. n.3LS/AC
35SUPPLY AND INSTALLATION OF PUMPS FOR NEW AHU
Fornitura e posa in opera di pompa per nuova UTAIT. No. Art. n.4Ls/Ac
36SUPPLY AND INSTALLATION INTEGRATION OF CONTROL SYSTEM
Fornitura e posa in opera integrazione al sistema di controlloIT. No. Art. n.5Ls/Ac
37TEASTING OF MECHANICAL SYSTEM
Verificare il funzionamento degli impianti meccaniciIT. No. Art. n.6Ls/Ac
38SUPPLY AND INSTALLATION OF NEW CHILLER
Fornitura e posa in opera nuovo chillerIT. No. Art. n.7Ls/Ac
39SUPLLY AND INSTALLATION FAN COIL UNITS CONCEALED
Fornitura e posa in opera ventilconvettore da incassoIT. No. Art. n.8Ea/No
40INSTALLATION NEW FAN COIL UNITS
Installazione nuovo ventilconvettoreIT. No. Art. n.9Ea/No
41SUPPLY AND INSTALLATION OF PIPELINES FAN COIL FOR OFFICE ZONE
Fornitura e posa in opera tubazioni ventilconvettori per la zona ufficiIT. No. Art. n.10Kg
42SUPPLY AND INSTALLATION OF PIMPING THERMAL INSULATION THICKENESS 13 mm DIAMETER 42 mm
Fornitura e posa in opera isolamento termico per tubazioni spessore 13 mm Diametro 42 mmIT. No. Art. n.11am
43SUPPLY AND INSTALLATION OF PIMPING THERMAL INSULATION THICKENESS 13 mm DIAMETER 35 mm
Fornitura e posa in opera isolamento termico per tubazioni spessore 13 mm Diametro 35 mmIT. No. Art. n.11bm
44SUPPLY AND INSTALLATION OF PIMPING THERMAL INSULATION THICKENESS 13 mm DIAMETER 28 mm
Fornitura e posa in opera isolamento termico per tubazioni spessore 13 mm Diametro 28 mmIT. No. Art. n.11cm
45SUPPLY AND INSTALLATION OF PIMPING THERMAL INSULATION THICKENESS 19 mm DIAMETER 42 mm
Fornitura e posa in opera isolamento termico per tubazioni spessore 19 mm Diametro 42 mmIT. No. Art. n.12m
46SUPPLY AND INSTALLATION OF PIMPING 6/10 mm ALUMINUM JACKET COVER
Fornitura e posa in opera rivestimento degli isolamenti in alluminio 6/10IT. No. Art. n.13m2
47SUPPLY AND INSTALLATION OF PIPELINES FOR DRAIN CONDENSATE DIAMETER 40 mm
Fornitura e posa in opera di tubazioni per lo scarico condensa Diametro 40 mmIT. No. Art. n.14m
48SUPPLY AND INSTALLATION OF PIPELINES FAN COIL FOR STORAGE AREA
Fornitura e posa in opera tubazioni ventilconvettori per magazzinoIT. No. Art. n.15Kg
49SUPPLY AND INSTALLATION OF PIMPING THERMAL INSULATION THICKENESS 30 mm
Fornitura e posa in opera isolamento termico per tubazioni Spessore 30 mmIT. No. Art. n.16m2
50SUPPLY AND INSTALLATION AIR DUCTS
Fornitura e posa in opera di canalizzazioni ariaIT. No. Art. n.17Kg
51SUPPLY AND INSTALLATION OF DUCTING THERMAL INSULATION THICKENESS 13 mm
Fornitura e posa in opera isolamento termico per canalizzazioni Spessore 13 mmIT. No. Art. n.18m2
52SUPPLY AND INSTALLATION RETURN DIFFUSER
Fornitura e posa in opera di diffusori di ripresaIT. No. Art. n.19Ea/No
53SUPPLY AND INSTALLATION BALANCING DAMPERS
Fornitura e posa in opera serrande si bilanciamentoIT. No. Art. n.20Ea/No
54SUPPLY AND INSTALLATION FIRE DAMPERS
Fornitura e posa in opera serranda tagliafuocoIT. No. Art. n.21Ea/No
55CHANGE CONNECTION CHILLED BUFFER TANK
Modifica connessioni idrauliche serbatoio inerzialeIT. No. Art. n.22Ls/Ac
56SUPPLY AND INSTALLATION CIRCULATING PUMPS AND ACCESSORIES
Fornitura e posa in opera di pompe di circolazione complete di accessoriIT. No. Art. n.23Ls/Ac
57MODIFICATION SPRINKLER SYSTEM TO OFFICE AREAS
Modifica impianto Sprinkler zona ufficiIT. No. Art. n.24Ls/Ac
58MODIFICATION SPRINKLER SYSTEM TO STORAGE AREAS
Modifica impianto Sprinkler zona magazzinoIT. No. Art. n.25Ls/Ac
59MODIFICATION SPRINKLER SYSTEM TO BOILER ROOM
Modifica impianto Sprinkler zona centrale termicaIT. No. Art. n.26Ls/Ac
60SUPPLY AND INSTALLATION CIRCULATION PUMPS
Fornitura e posa in opera di pompa di circolazioneIT. No. Art. n.27Ea/No
61SUPPLY AND INSTALLATION WATER CLOSET UNIT
fornitura e posa in opera di vaso sospesoIT. No. Art. n.28Ls/Ac
Total Mechanical Work - Totale Lavori Meccanici
PART IV- ELECTRICAL WORK / Parte VI - Lavori Elettrici
62ADJUST AND NEW CONNECTION IN EXISTING MAIN BREAKER 4x630A IN THE EXISTING BUILDING 71388 (SUBSTATION) - PANEL 2A-BLDG 1380
Sistemazione e nuovo cablaggi/regolazioni dell'int. esistente 4x630A, all'interno della cabina esistente 71388 (CABINA ELETTRICA) pannello 2A - edificio 1380IT. No. Art. n.1LS/AC
63UPGRADE EXISTING ELECTRYCAL "PANEL MDP" (analyse lay-out diagram)
Adeguamento impiantistico quadro elettrico esistente "PANEL MDP" (vedere schemi elettrici).IT. No. Art. n.2aLS/AC
64UPGRADE EXISTING ELECTRICAL "PANEL A " (analyse lay-out diagram)
Adeguamento impiantistico quadro elettrico esistente "PANEL A " (vedere schemi elettrici).IT. No. Art. n.2bLS/AC
65UPGRADE EXISTING ELECTRICAL "PANEL B" (analyse lay-out diagram)
Adeguamento impiantistico quadro elettrico esistente "PANEL B" (vedere schemi elettrici).IT. No. Art. n.2cLS/AC
66UPGRADE EXISTING ELECTRICAL "PANEL C" (analyse lay-out diagram)
Adeguamento impiantistico quadro elettrico esistente "PANEL C" (vedere schemi elettrici).IT. No. Art. n.2dLS/AC
67UPGRADE EXISTING ELECTRICAL "PANEL D" (analyse lay-out diagram)
Adeguamento impiantistico quadro elettrico esistente "PANEL D" (vedere schemi elettrici).IT. No. Art. n.2eLS/AC
68UPGRADE EXISTING ELECTRICAL "PANEL M" (analyse lay-out diagram)
Adeguamento impiantistico quadro elettrico esistente "PANEL M" (vedere schemi elettrici).IT. No. Art. n.2fLS/AC
69FURNISHING AND INSTALLATION NEW ELECTRICAL "PANEL N " (analyse lay-out diagram)
Fornitura e posa in opera di nuovo quadro elettrico "PANEL N " (vedere schemi elettrici).IT. No. Art. n.2gLS/AC
69FURNISHING AND INSTALLATION NEW TRANSFORMER 400Vac / 208-120Vac 50-60HZ-200KVA
Fornitura e installazione convertitore 400Vac / 208-120Vac 50-60HZ-200KVAIT. No. Art. n.2hLS/AC
70NEW ELECTRYCAL "PANEL FMU" WITH USA OUTLET 100A 208/120Vac.
Fornitura e posa in opera di nuovo quadro FMU, completo di presa elettrica americana da 100A 208/120Vac.IT. No. Art. n.2iEA/NO
71FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7R 240mmq
Fornitura e installazione di Cavo elettrico FG7R 240mmqIT. No. Art. n.3am
72FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7R 185mmq
Fornitura e installazione di Cavo elettrico FG7R 185mmqIT. No. Art. n.3bm
73FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7R 70mmq
Fornitura e installazione di Cavo elettrico FG7R 70mmqIT. No. Art. n.3cm
74FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7R 35mmq
Fornitura e installazione di Cavo elettrico FG7R 35mmqIT. No. Art. n.3dm
75FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7OR 5G25mmq
Fornitura e installazione di Cavo elettrico FG7OR 5G25mmqIT. No. Art. n.3em
75FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7OR 5G4mmq
Fornitura e installazione di Cavo elettrico FG7OR 5G4mmqIT. No. Art. n.3fm
76FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7OR 4G2,5mmq
Fornitura e installazione di Cavo elettrico FG7OR 4G2,5mmqIT. No. Art. n.3gm
76FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7OR 3G6mmq
Fornitura e installazione di Cavo elettrico FG7OR 3G6mmqIT. No. Art. n.3hm
77FURNISHING AND INSTALLATION ELECTRICAL CABLE FG7OR 3G2,5mmq
Fornitura e installazione di Cavo elettrico FG7OR 3G2,5mmqIT. No. Art. n.3im
78FURNISHING AND INSTALLATION ELECTRICAL CABLE NO7V-K 1X16mmq
Fornitura e installazione di Cavo elettrico NO7V-K 1X16mmqIT. No. Art. n.3jm
78FURNISH AND INSTALL OF PVC PIPE - 25 DIAMETER
Fornitura e posa in opera di tubo in PVC - diametro 25 mmIT. No. Art. n.4am
79FURNISH AND INSTALL OF PVC PIPE - 32 DIAMETER
Fornitura e posa in opera di tubo in PVC - diametro 32 mmIT. No. Art. n.4bm
80FURNISH AND INSTALL OF PVC PIPE - 50 DIAMETER
Fornitura e posa in opera di tubo in PVC - diametro 50 mmIT. No. Art. n.4cm
80FURNISHING AND INSTALLATION n°2 COMMUNICATION OUTLETS GROUP RJ45 cat.5e TYPE
Fornitura e posa in opera di n°2 prese per telecomunicazioni RJ45 cat.5eIT. No. Art. n.5EA/NO
81FURNISHING AND INSTALLATION CAT.5e UTP, UNSHIELDED
Fornitura e posa in opera di cavo UTP cat.5e, non schermatoIT. No. Art. n.6m
82FURNISHING AND INSTALLATION SCHUKO RECEPTACLE COMPLEX, 230 VOLTS, N° 2X16 AMPS, 2P+G, WITH AUTOMATIC CIRCUIT BREAKER 3KA-16A-230V
Fornitura e posa in opera di n°2 prese SCHUKO, 230V 2X16A 2P+T, con int. automatico 3kA-16A-230V.IT. No. Art. n.7aEA/NO
83FURNISHING AND INSTALLATION BPRESA RECEPTACLE COMPLEX, 230 VOLTS, N° 2X10/16 AMPS, 2P+G, WITH AUTOMATIC CIRCUIT BREAKER 3KA-16A-230V
Fornitura e posa in opera di n°2 Bprese, 230V 2X10/16A 2P+T, con int. automatico 3kA-16A-230V.IT. No. Art. n.7bEA/NO
84FURNISHING AND INSTALLATION US RECEPTACLES COMPLEX WITH N°2 2x15A CB (120V), WITH AUTOMATIC CIRCUIT BREAKER 3KA-2X10A-230V
Fornitura e posa in opera di n°2 prese USA, 120V 2P+Tx15A, con interruttore automatico 3kA, 2x10A.IT. No. Art. n.7cEA/NO
85FURNISHING AND INSTALLATION OF WALL FLUSHED POWER POINT FOR GENERAL USE.
Fornitura e posa in opera di punto di alimentazione generale.IT. No. Art. n.8aEA/NO
86UPGRADE ELECTRICAL SYSTEM DAMAGE
Adeguamento impiantistico dell'impianto elettrico danneggiatoIT. No. Art. n.8bLS/AC
87REPLACE, DAMAGED RESIDUAL CURRENT OPERATED CIRCUIT BREAKER
sostituire differenziali danneggiati non funzionantiIT. No. Art. n.8cLS/AC
88FURNISHING AND INSTALLATION LIGHT POINT
Fornitura e installazione di Punto luceIT. No. Art. n.9aEA/NO
89FURNISHING AND INSTALLATION LIGHT POINT WITH DOUBLE STABLE RELAY
Fornitura e installazione di Punto luce a rele (rele' bistabile compreso)IT. No. Art. n.9bEA/NO
90FURNISHING AND INSTALLATION NEW SENSOR POWER LIGHT - LUXOMAT PD3-1C TYPE
Fornitura e posa in opera di nuovo sensore di presenza per accensione luci - tipo luxomat PD3-1CIT. No. Art. n.9cEA/NO
91FURNISHING AND INSTALLATION NEW SENSOR POWER LIGHT - LUXOMAT PD4-M-DALI/DSI-AP TYPE WITH CONTROL PANEL AND SLAVE SENSOR
Fornitura e posa in opera di nuovo sensore di presenza per accensione luci - tipo luxomat PD4-M-DALI/DSI-AP completo di pannello per la programmazione e sensore slave.IT. No. Art. n.9dLS/AC
92FURNISHING AND INSTALLATION MOVEMENT DETECTOR RECESSED WALL
Fornitura e posa in opera di nuovo sensore di movimento incassato a pareteIT. No. Art. n.9eEA/NO
93FURNISHING AND INSTALLATION WALL FLUSHED LIGHT BUTTON OR SWITCH
Fornitira e posa in opera di Interruttore o pulsante sottotracciaIT. No. Art. n.9fEA/NO
94FURNISHING AND INSTALLATION LIGHTING FIXTURE RECESSED TYPE. LED LIGHTING FIXTURE 3F-FILIPPI 21244 L 323x10W LED SP 596x596
Fornitura e posa in opera di corpo illuminante ad incasso. corpo luce a led tipo 3f-filippi 21244 l 323x10W led sp 596x596mmIT. No. Art. n.10aEA/NO
95FURNISHING AND INSTALLATION LIGHTING FIXTURE RECESSED TYPE. LED LIGHTING FIXTURE 3F-FILIPPI 21244 L 323x10W LED SP 596x596 - WITH EMERGENCY KIT UNIT 2H
Fornitura e posa in opera di corpo illuminante ad incasso. corpo luce a led tipo 3f-filippi 21244 l 323x10w led sp 596x596mm - con kit di emergenza 2hIT. No. Art. n.10bEA/NO
96FURNISHING AND INSTALLATION RECESSED SPOTLIGHTS LED LIGHTING FIXTURE 3F-FILIPPI 37811 GALASSIA 26W
Fornitura e posa in opera di faretto da incasso a led tipo 3ffilippi 37811 galassia 26WIT. No. Art. n.10cEA/NO
97FURNISHING AND INSTALLATION RECESSED SPOTLIGHTS LED LIGHTING FIXTURE 3F-FILIPPI 37811 GALASSIA 26W - WITH EMERGENCY KIT UNIT 2H
Fornitura e posa in opera di faretto da incasso a led tipo 3ffilippi 37811 galassia 26W - con kit di emergenza 2hIT. No. Art. n.10dEA/NO
98FURNISHING AND INSTALLATION AUTOFED LED EMERGENCY LIGHT -2H-220 LUMEN-IP65
Fornitura e posa in opera di lampada di emergenza led autoalimentata - 2h-220 lumen-IP65IT. No. Art. n.10eEA/NO
99FURNISHING AND INSTALLATION EXTERNAL FLOOD LED LIGHT - 17W - IP65 DISANO 1264 VEGA TYPE.
Fornitura e posa in opera di proiettore asimmetrico da esterno a LED 17W-IP65 tipo DISANO 1264 VEGA.IT. No. Art. n.10fEA/NO
100FURNISHING AND INSTALLATION LED LIGHTING FIXTURE 3F LINDA LED 2X30W CONC L1570 TYPE
Plafoniera per lampade a LED tipo 3F filippi Linda LED 2X30W CONC L1570IT. No. Art. n.10gEA/NO
101FURNISHING AND INSTALLATION LED LIGHTING FIXTURE 3F LINDA LED 2X30W/865 EP L1570 TYPE - WITH EMERGENCY KIT - 2H
Plafoniera per lampade a LED tipo 3F LINDA 2X30W/865 EP L1570 - completa di kit di emergenza - autonomia 2hIT. No. Art. n.10hEA/NO
102FURNISHING AND INSTALLATION EXTERNAL FLOOD LED LIGHT, 116W, IP65 3FFILIPPI LEM 2 100 DALI
Fornitura e posa in opera di riflettore industriale da esterno a LED 116W-IP65 tipo 3FFILIPPI LEM 2 100 DALIIT. No. Art. n.10iEA/NO
103FURNISHING AND INSTALLATION LED LIGHTING FIXTURE 3FFILIPPI BETA i3f led 2X30W EO CONC L1565 TYPE - WITH EMERGENCY KIT - 2H

Fornitura e posa in opera di plafoniera per lampade a LED tipo filippi BETA i3F LED 2x30W ep conc l1565

completa di kit di emergenza - 2h - da richiedere al produttoreIT. No. Art. n.10jEA/NO
104FURNISHING AND INSTALLATION EXTERNAL FLOOD LED LIGHT - 94W - IP65 DISANO 1151 INDIO TYPE.
Fornitura e posa in opera proiettore asimmetrico da esterno a LED 94W-IP65 tipo DISANO 1151 INDIO.IT. No. Art. n.10kEA/NO
105GROUNDING PROTECTION SYSTEM EXTENSION - NEW EQUIPOTENTIAL BONDING
Estensione Impianto di messa a terra - nuovi collegamenti equipotenzialiIT. No.11aLS/AC
106FURNISH AND INSTALL GROUND BAR 50X6X1000mm
Fornitura e poso in opera di Barra di terra 50X6X1000mmIT. No. Art. n.11bEA/NO
107FURNISHING AND INSTALLATION CLASS I+II SPD IN ELECTRICAL PANEL
Fornitura e posa in opera di SPD di classe I+II all'interno di quadro elettricoIT. No. Art. n.12EA/NO
108FURNISHING AND INSTALLATION CLASS II SPD IN ELECTRICAL PANEL
Fornitura e posa in opera di SPD di classeII all'interno di quadro elettricoIT. No. Art. n.13EA/NO
109FURNISHING AND INSTALLATION CLASS III SPD IN ELECTRICAL PANEL OR ELECTRICAL EQUIPMENT
Fornitura e posa in opera di SPD di classe III all'interno di quadro elettrico o apparecchiatura elettricaIT. No. Art. n.14aEA/NO
110FURNISHING AND INSTALLATION CLASS III SPD FOR RACK DATA SYSTEM
Fornitura e posa in opera di SPD di classe III a servizio dell'impainto rack datiIT. No. Art. n.14bLS/AC
110FURNISH AND INSTALL OPTICAL FIRE SMOKE DETECTOR, ADRESSABLE TYPE.
Fornitura e posa in opera di rivelatore di fumo indirizzabileIT. No. Art. n.15aEA/NO
111FURNISH AND INSTALL SMOKE DETECTOR ABOVE FALSECEILING WITH OPTICAL/ACOUSTIC REPEATER
Fornitura e posa in opera di rivelatore di fumo indirizzabile, sopra controsoffitto con ripetiore ottico/acustico.IT. No. Art. n.15bEA/NO
112FURNISH AND INSTALL LOOP CABLE FOR FIRE ALARM DETECTORS.
Fornitura e posa in opera di cavo loop per allarme incendio.IT. No. Art. n.15cm
113TEST AND CERTIFICATION OF THE NEW ELECTRCYCAL SYSTEM.
Collaudo e certificazione del nuovo impianto elettricoIT. No. Art. n.16aLS/AC
114EXECUTION OF THE AS BUILT DRAWINGS AND SCHEDULES
Redazione ed emissione di disegni e schemi di As Built finaliIT. No. Art. n.16bLS/AC
114FURNISHING AND INSTALLATION NEW TRAY CABLE 75x75mm
Fornitura e posa in opera di nuovo canale metallico 75x75mmIT. No. Art. n.17am
115FURNISHING AND INSTALLATION NEW TRAY CABLE 200x100mm
Fornitura e posa in opera di nuovo canale metallico 200x100mmIT. No. Art. n.17bm
TOTAL PART IV / Totale Parte IV
REPAIR WORK SUMMARY / Riepilogo Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK
PART III - MECHANICAL WORK
PART IV - ELECTRICAL WORK
TOTAL PRICE / Costo Totale

&CPage &P of &N

Summary

CONSTRUCTION COST ESTIMATE BREAKDOWN R
ASHE 16-1033 - RENOVATE FAC.1380 FOR 606 ACS BED DOWNADDRESS
INSTRUCTIONS FOR COMPLETING FORMPROPOSED TOTAL CONTRACT PRICE
RENOVATE FAC.1380 FOR 606 ACS BED DOWN
PURCHASE REQUEST NUMBERPROJECT NUMBERWORK LOCATION
ASHE 16-1033AREA F, AVIANO AIR BASE, ITALY
MATERIAL COSTSLABOR COSTS
LINE NO.ITEMUNIT OF MEASUREQUANTITYUNITTOTALMANHOURS MANDAYSAVERAGE RATETOTALOTHER DIRECT COSTSLINE TOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
A.NEW CONSTRUCTION / Nuova Costruzione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS
REMOVAL OF INTERIOR WOOD DOORS

Rimozione di porte in legno interne

DEMOLITION OF MASONRY PARTITIONS

Demolizione di tramezzi in muratura

PART IV - ELECTRICAL WORK
REMOVAL OF INTERIOR SECTIONAL DOORS

Rimozione di portoni

B.REPAIR / Ristutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK
PART III - MECHANICAL WORK
PART IV - ELECTRICAL WORK
SUB TOTAL B.
TOTAL PRICE / Costo Totale

&C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY&RSheet &Pof &N

Grand Total

CONSTRUCTION COST ESTIMATE BREAKDOWN
ASHE 16-1033 - RENOVATE FAC.1380 FOR 606 ACS BED DOWN
INSTRUCTIONS FOR COMPLETING FORM
RENOVATE FAC.1380 FOR 606 ACS BED DOWN
ASHE 16-1033
REMOVAL OF INTERIOR WOOD DOORS

Rimozione di porte in legno interne

DEMOLITION OF MASONRY PARTITIONS

Demolizione di tramezzi in muratura

REMOVAL OF INTERIOR SECTIONAL DOORS

Rimozione di portoni

0.0000.00
A. NEW CNSTRB. REPAIRTOTAL A+B (€)
TOTAL MATERIAL COSTS€
TOTAL LABOR COSTS
TOTAL OTHER DIRECT COSTS
TOTAL DIRECT COSTS
OVERHEAD%
SUBTOTAL
PROFIT%€
TOTAL PRICE
DATEFIRM NAME
PROJECT MANAGERBY
INSTRUCTIONS TO OFFERORS
78

&C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY&RSheet &Pof &N

1. The purpose of this form is to provide a standard format by which the offeror submits to the Government a summary of incurred and estimated costs, (and attached supporting information) suitable for detailed review and analysis. Prior to the award of a contract resulting from this proposal, the offeror shall, under the conditions stated in ASPR 3-807.3, be required to submit a certificate of current cost or pricing data (see ASPR 3-807.3 and 3-807.4).

2. In addition to the specific information required by this form, the offeror is experted, in good faith, to incorporate in and submit with this form any additional data, supporting schedules, or substation which are reasonably required for the conduct of an appropriate review and analysis in the light of the specific facts of this procurement. For effective negotiations, it is essential that there be a clean understanding of:

a. The existing, verifiable data.

b. The judgmental factors applied in projecting from know data to the estimate, and

c. The contingencies used by the offeror in his proposed price.

In short, the offeror's estimating process itself needs to be disclosed.

3. When attachment of supporting cost or pricing data to this form is impracticable, the data will be described (with schedules as appropriate) and made available to the contracting officer or his authorized representative upon request.

4. By submission of this proposal the offeror grants to the contracting officer, or his authorized representative, the right to examine, for the purpose of verifying the cost or pricing data submitted, those books, records, documents and other supporting data which will permit adequate evaluation of such cost or pricing data, along with the computations and projections used therein. This right may be exercised in connection with any negotiations prior to contract award.

Col 1 Item. Description of materials required, work to be done, special equipment needed, etc. Breakdown should be in sufficient detail to permit itemizing of all direct costs.

Col 2 Unit of Measure. Description of the unit in which each item is to be estimated (examples - square yards-SY, cubic yards-CY, square feet- SF, linear feet-LF, board feet-BF, each-EA,, pound-LB).

Col 3 Quantity. Contractor's estimated of quantity required in terms of unit of measure (column 2). Item and units of measure will be furnished by the Government. Quantity estimates will be furnished by the Government only when it is anticipated that a unit price contract will be issued. Otherwise, the contractor is responsible for determining quantity estimates.

Col 4 and 5 Material Costs. Enter unit cost (Col 4) of material to be supplied and total cost (Col 5) for item listed in column 1.

Col 6, 7 and 8 Labor Costs. Enter in col 6 the estimated number of manhours or mandays needed to perform the work listed in column 1. Enter in col 7 the average rate per manhour (manday) and in col 8 the total labor cost.

Col 9 Other Direct Costs. Enter estimated costs of special equipment and other items (listed in column 1), which are special to the contract and of significant dollar value.

Col 10 Line. Self-explanatory.

Note: In addition to other totals entered on various pages, the grand total of column 10, plus overhead and profit will be shown on the last page as follows:

Foglio1

File details come from the government source that posted it. Updated .