Waterjet_Salient_Requirements_-_Clarification_27_Feb_2019.docx
DOCX document 12 KB Posted
- Attached to
- 48 MXG WaterJet Federal contract opportunity
- Solicitation number
- FA558719Q1006
About this file
This document includes the clarification made on 27 Feb 2019.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Waterjet_Salient_Requirements_-_Clarification_28_Feb_2019.docx | DOCX document | |
| WaterJet_Salient_Requirements_v3.xlsx | XLSX spreadsheet | |
| COMBO_-_WaterJet_-_FA558719Q1006.pdf | ||
| FA558719Q1006_Amendment_00002.doc | DOC document | |
| Waterjet_Salient_Requirements_-_Clarification_25_Feb_2019.docx | DOCX document | |
| WaterJet_Salient_Requirements_v2.xlsx | XLSX spreadsheet | |
| COMBO_-_WaterJet_-_FA558719Q1006.pdf | ||
| FA558719Q1006_Amendment_00001.doc | DOC document | |
| COMBO_-_WaterJet_-_FA558719Q1006.pdf | ||
| WaterJet_-_Quote_Sheet.pdf | ||
| WaterJet_Salient_Requirements.xlsx | XLSX spreadsheet |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Clarifications Regarding the Waterjet Salient Requirements (27 Feb 2019)
Original: Z-axis Travel Range = 8 feet Issue: That measurement is unrealistic, given the rest of the salient requirements.
Request: Please clarify the unit of measurement and provide an updated specification.
Clarification: The updated Z-axis Travel Range is 8 inches.
File details come from the government source that posted it.