Waterjet_Salient_Requirements_-_Clarification_25_Feb_2019.docx
DOCX document 13 KB Posted
- Attached to
- 48 MXG WaterJet Federal contract opportunity
- Solicitation number
- FA558719Q1006
About this file
This document provides clarifications to the questions asked about this solicitation's salient requirements. The clarifications are also reflected in the Salient Requirements v2 document.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Waterjet_Salient_Requirements_-_Clarification_28_Feb_2019.docx | DOCX document | |
| WaterJet_Salient_Requirements_v3.xlsx | XLSX spreadsheet | |
| COMBO_-_WaterJet_-_FA558719Q1006.pdf | ||
| FA558719Q1006_Amendment_00002.doc | DOC document | |
| Waterjet_Salient_Requirements_-_Clarification_27_Feb_2019.docx | DOCX document | |
| FA558719Q1006_Amendment_00001.doc | DOC document | |
| WaterJet_Salient_Requirements_v2.xlsx | XLSX spreadsheet | |
| COMBO_-_WaterJet_-_FA558719Q1006.pdf | ||
| WaterJet_-_Quote_Sheet.pdf | ||
| WaterJet_Salient_Requirements.xlsx | XLSX spreadsheet | |
| COMBO_-_WaterJet_-_FA558719Q1006.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Clarifications Regarding the Waterjet Salient Requirements (25 Feb 2019)
Original: Nomenclature = “Footprint (w/Controller)” Issue: “Footprint (w/Controller)” is an Omax phrase.
Request: Please clarify the original statement.
Clarification: “Footprint (w/Controller)” means the amount of space covered by the machine and user.
Original: Footprint (w/Controller) = No bigger than 14” by 12” Issue: The current requirement does not provide space for the pump, hopper and requested garnet removal system.
Request: “Please provide shop layout so that a determination can be made as to whether there is enough space to fit an entire system, regardless of manufacturer.”
Clarification: When we said no bigger than 14” by 12” in our original statement, we meant 14 feet by 12 feet. However, we have an 18 feet by 18 feet area in our section allocated for the waterjet. So, we need the entire system to fit in that 18 feet by 18 feet space.
Original: On-site installation = Base Services don't have the capability to level and set up the machine.
Issue: We are unclear of the requested services/expectation for on-site installation.
Request: Please clarify what is meant by “on-site installation.”
Clarification: We want the manufacturer to install the waterjet on RAF Lakenheath, Hangar 7. This includes levelling the machine and making a test cut to ensure the machine settings are correct.
Original: Training = 2-3 days of training to teach the fundamentals to our shop supervisors.
Issue: There is an unclear expectation of the depth of training requested—is more than the basic familiarization training that can be provided during installation needed?
Request: “Please specify whether more detailed operator and maintenance training would be required.”
Clarification: We are just requesting the basic familiarization training for operating and maintaining the waterjet.