FA5422‐17‐R‐7009 – Small Shelter Systems Questions and Answers #3
1. In reference to the raised floor system for the Small Shelter System, please provide the following minimum salient characteristics:
a. Dimensions
b. Longest frame section
c. Wind load resistance
d. Snow load resistance
e. Floor load
f. Quantity of base pads
g. Quantity of stairs
Answer:
a. Minimum dimensions of 20'x32', as that is the dimensions of the frame of the tent. If doable, a little more space on the edges would be nice.
b. 8' in length
c. 80 MPH sustained/100 MPH gusts resistance
d. 20 PSF Snow load resistance
e. 100 PSF load for floors.
f. don't understand this question.
g. 1 set of stairs to go to front entrance
2. Is the raised floor system required to be adjustable to accommodate uneven terrain?
Answer: Yes
3. If the Small Shelter System is raised off the ground, is the ECU required to be raised off the ground at the same level as the shelter?
Answer: it is not required to be raised. Many of the ECUs in use here are on wooden or concrete block platforms