Reference.pdf

PDF 1 MB Posted

Attached to
Install Utility Lines at Vehicle Wash Facility Federal contract opportunity
Solicitation number
FA5270-16-R-0011
Issued by
Department of the Air Force Pacific Air Forces

About this file

Manufacturer Information

View the file

Other files for this federal contract opportunity

Other files attached to Install Utility Lines at Vehicle Wash Facility, newest first.
File Type Posted
Question_and_Answer.pdf PDF
Amendment_2.pdf PDF
Amendment_1.pdf PDF
Attachment_2.pdf PDF
Attachment_3.pdf PDF
FA5270-16-R-0011.pdf PDF
Attachment_1.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A

B B

C C

D D

CUSTOMER APPROVAL of DRAWINGS

Signed drawing(s) is a statement that the dimesions, design, and application have been reviewed and are approved for fabrication.

ELECTRIC SERVICE REQUIRED:

CITY WATER FEED:

SANITARY SEWER:

NATURAL GAS:

AIR:

DATE SITE READY FOR INSTALL:

"Provided by Others" ACKNOWLEDGED

INITIAL

TITLE

DATE

APRROVED BY

COMPANYNAME

NOTES

CUSTOMER MUST VERIFY UTILITY REQUIREMENTS WITH INITIALS

233 Veterans Drive South Haven, MI 49090

Phone: 269-637-1197 Fax: 269-637-0177 www.riveer.com CAGE: 5X781

230 Volt, 3pH, 60Hz

Min. 40 PSI

N/A

Riveer

04/08/2016

TITLE

Diesel Power Wash - RTS 500 Recovery System

DWG NO

ALSBS033

CREATED ON

2/26/2016

PARTS LIST

MATERIALDESCRIPTIONQTYPART NUMBERTITLEITEM

Stainless SteelHanger Combo 12 ga 2RIV 214196-12HANGER COMBO CCS6

HOSE 038 X 50 HI PRESS WITH FITTINGS2AHO0154HOSE PRESSURE WASHER

4GPM @ 1500PSI DUAL LANCE2AHPG-1007WASH GUN ASSY4

Generic 1REMOTE PANEL 5 ALARMREMOTE PANEL3

EST - Kadena AFB LRS - ISO Assy

ACTSBS005EST - Kadena AFB LRS - ISO Assy2

42ft x 18ft Rack Assy

1ARK089

42ft x 18ft Rack Assy

A A

B B

C C

D D

DRAWN

COMPANY

MFG

MATERIAL

SIZE

SCALE

REV

233 Veterans Drive South Haven, MI 49090

Phone: 269-637-1997 Fax: 269-637-0177 www.riveer.com CAGE: 5X781

FINISH

REVISED

TITLE

DWG NO

SHEET

Randy Grieves

2/26/2016

1:110

A

ALSBS033

Diesel Power Wash - RTS 500 Recovery

System

16'-0"

18'-

3'-0"

8'-1"

29'-1

42'-

" 5'-1"

52'-2

11'-1" REF.

8'-6

" REF.

18'-

3'-0"

8'-1"

23 465

FUEL TANK

POWER DISCONNECT

CONTROL PANEL

PLF PUMP

DIESEL POWER WASHER

SUPPLY FAN

EDSON RECOVERY PUMP

HVAC UNIT

OZONE PUMP

HOLDING TANK

RTS 500

ABSOLUTE FILTER

OZONE GENERATOR

HIGH PRESSURE COUPLING

FOR PRESSURE WASHER HOSE CONNECTION

colin Callout City Water Inlet colin Callout Power Into Disconnect Here 150 Amps 230v 3PH 60HZ

A A

B B

C C

D D

DRAWN

COMPANY

MFG

MATERIAL

SIZE

SCALE

REV

233 Veterans Drive South Haven, MI 49090

Phone: 269-637-1997 Fax: 269-637-0177 www.riveer.com CAGE: 5X781

FINISH

REVISED

TITLE

DWG NO

SHEET

Randy Grieves

3/1/2016

1 / 50

A

ACTSBS005

EST - Kadena AFB LRS - ISO Assy

97.00 238.50

101.75

129.22 REF.

83.50 REF.

72.00 colin Callout City Water Inlet colin Callout Power Into Disconnect Here 150 Amps 230v 3PH 60HZ colin Callout City Water Inlet