A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
PUTT
PUTT
FACILITY:
DATE APPR
04/20/2020
04/20/2020DATE:
04/20/2020DATE:
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
TITLE SHEET
G-1
RENOVATE ROOM 149 BLDG 10480
10480
SCHEDULE OF DRAWINGS
SHEET REFERENCE NUMBER SHEET TITLE
G-1
TITLE SHEET
AD-1
DEMOLITION PLAN
A-1
FLOOR PLAN
A-2
FLOOR PLAN
E-1
EXISTING ELECTRICAL
E-2
ELECTRICAL PLAN
E-3
LIGHTING PLAN
MAP KEY
LOCATION DESCRIPTION
RICHARDSON VISITORS GATE
ARCTIC VALLEY GATE GLENN HWY SOUTHBOUND EXIT
ELMENDORF VISITORS GATE
654 6TH STREET: FIRE STATION 4
8517 20TH STREET: SECURITY FORCES
730 QUARTERMASTER ROAD: 673D CES CONTRACT MANAGEMENT
2204 3RD STREET: CORP OF ENGINEERS DISTRICT OFFICE
10480 SIJAN AVENUE: CONTRACTING
PROJECT LOCATION
JOINT BASE ELMENDORF-RICHARDSON
673RD CIVIL ENGINEER SQUADRON
KEY PLAN
NIC
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
PUTT
PUTT
FACILITY:
DATE APPR
04/20/2020DATE:
04/20/2020DATE:
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
DEMOLITION PLAN
AD-1
RENOVATE ROOM 149 BLDG 10480
10480
DEMOLITION NOTES
1. DEMOLISH DOORS AND FRAMES.
2. DEMOLISH WOOD PANELING UNDER WINDOWS,
TRIM, AND SOUTHEAST WALL.
3. DEMOLISH DOWN TO STUDS; SOME AREAS HAVE
2 LAYERS OF GWB, SOME HAVE ONE LAYER.
4. CMU/CONCRETE WALLS CONTAIN LBP.
5. DEMOLISH LIGHT FIXTURES.
6. DEMOLISH CEILING GRID AND PANELS.
1 1
2 2
NOT FOR CONSTRUCTION.
CONTRACTOR TO FIELD VERIFY ALL
DISTANCES, DIMENSIONS, & LOCATIONS.
04/20/2020
3 3
3 3 3
5 5 5 5 5
5 5 5 5 5
AutoCAD SHX Text N
NIC
≈13'-0"
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY: PUTT
DRAWN BY: PUTT
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
FACILITY:
DATE APPR
DATE: 04/20/2020
DATE: 04/20/2020
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
FLOOR PLAN
A-1 10480
NOT FOR CONSTRUCTION.
CONTRACTOR TO FIELD VERIFY ALL
DISTANCES, DIMENSIONS, & LOCATIONS.
4/20/2020
RENOVATE ROOM 149 BLDG 10480
CONSTRUCTION NOTES
1. PROVIDE NEW DOORS, FRAMES, AND
ASSOCIATED HARDWARE
2. PROVIDE NEW GLASS PARTITION AND GLASS
DOOR
3. FUR OUT AND FINISH WALLS
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY: PUTT
DRAWN BY: PUTT
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
FACILITY:
DATE APPR
DATE: 04/20/2020
DATE: 04/20/2020
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
FLOOR PLAN
A-2 10480
NOT FOR CONSTRUCTION.
CONTRACTOR TO FIELD VERIFY ALL
DISTANCES, DIMENSIONS, & LOCATIONS.
4/20/2020
RENOVATE ROOM 149 BLDG 10480
SEE SOW (01020)
SECTION 4.5.1
SEE SOW (01020)
SECTION 4.5.1
20 MIN FIRE RATING
20 MIN FIRE RATING
PANEL "G" OUTSIDE HALLWAY DOUBLE DOORS
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
PUTT
PUTT
FACILITY:
DATE APPR
04/20/2020DATE:
04/20/2020DATE:
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
EXISTING ELECTRICAL
E-1 10480
CONSTRUCTION NOTES
1. EXISTING CONDITIONS MUST BE FIELD
VERIFIED BY THE CONTRACTORS PRIOR TO
BIDDING. IF ANY FIXTURES OR DEVICES ARE
NOT SHOWN ON THIS DRAWING, THE
CONTRACTOR IS STILL RESPONSIBLE FOR
REPLACING AS DESCRIBED IN THE SOW.
2. ALL EXISTING RECEPTACLES MUST BE
REPLACED AS DESCRIBED IN THE SOW.
NOT FOR CONSTRUCTION.
CONTRACTOR TO FIELD VERIFY ALL
DISTANCES, DIMENSIONS, & LOCATIONS.
04/20/2020
RENOVATE ROOM 149 BLDG 10480
PANEL "G"
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
PUTT
PUTT
FACILITY:
DATE APPR
04/20/2020DATE:
04/20/2020DATE:
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
ELECTRICAL PLAN
E-2 10480
CONSTRUCTION NOTES
1. Provide and install new 20 Amp, NEMA 5-20 duplex receptacles in the same locations as the existing receptacles. Receptacle and cover colors shall be selected by the government prior to install.
NOT FOR CONSTRUCTION.
CONTRACTOR TO FIELD VERIFY ALL
DISTANCES, DIMENSIONS, & LOCATIONS.
04/20/2020
RENOVATE ROOM 149 BLDG 10480
S
DM-3
S
DM
S
DM-3
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
PLOT SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
PRELIMINARY
DRAWINGS
1:1
AF CONTRACT NUMBER:
INV. NUMBER:
NTS
FXSB20-XXXX
X.DWG
PUTT
PUTT
FACILITY:
DATE APPR
04/20/2020DATE:
04/20/2020DATE:
DATE:
DATE:
DRAWING NO:
I
U.S. AIR FORCE
LIGHTING PLAN
E-3 10480
CONSTRUCTION NOTES
1. Provide and install new 6” x 4' LED flush lens light fixtures. New fixtures shall be 4000K color temperature, CRI 80+, 4000 lumens.
2. Provide and install new 20A light switches at each doorway. The large room must have 3-way dimmer switches installed at the main entry door and just outside the small room door. The small room shall be on a different switch than the large room, and have a single dimmer switch installed at the hallway door entry. Lighting in both rooms shall be on 1-100% dimmers.
NOT FOR CONSTRUCTION.
CONTRACTOR TO FIELD VERIFY ALL
DISTANCES, DIMENSIONS, & LOCATIONS.
04/20/2020
RENOVATE ROOM 149 BLDG 10480
2 2 2
| Sheets and Views |
| Innovation Lab 2.0-Cover Sheet |
| Innovation Lab 2.0-AD-1 |
| Innovation Lab 2.0-A-1 |
| Innovation Lab 2.0-A-2 |
| Innovation Lab 2.0-E-1 |
| Innovation Lab 2.0-E-2 |
| Innovation Lab 2.0-E-3 |
File details come from the government source that posted it. Updated .