Attchmt_2_Specs_Tents.docx

DOCX document 16 KB Posted

Attached to
Small Shelters Federal contract opportunity
Solicitation number
FA5000-19-Q-0011
Issued by
Department of the Air Force Pacific Air Forces

About this file

The purpose of this amendment is to change the solicitation close date to 27 Dec 2:00p.m. Alaska time

View the file

Other files for this federal contract opportunity

Other files attached to Small Shelters, newest first.
File Type Posted
Attchmt_2_Specs_Tents.docx DOCX document
RFQ.docx DOCX document
Attachment_1_Pricing_Schedule.docx DOCX document
Questions_Regarding_SShelters.docx DOCX document
Questions_Regarding_SShelters.docx DOCX document
Attchmt_2_Specs_Tents.docx DOCX document
Attachment_1_Pricing_Schedule.docx DOCX document
RFQ.docx DOCX document
RFQ.docx DOCX document
Attachment_1_Pricing_Schedule.docx DOCX document
RFQ.docx DOCX document
RFQ.docx DOCX document
Attachment_1_Pricing_Schedule.docx DOCX document
Attchmt_2_Specs_Tents.docx DOCX document
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 2 Alaska Small Shelter Systems, Version 2 (P/N: AK-2032.5-V280) OR EQUAL in accordance with the following minimum specifications:

· General

· Size: 20’ wide x 32.5’ long x 10’ high (Quonset Shape)

· Color: Tan or Green

· Frame:

· Shelter shall have aluminimum frame, with no poles in the center of the shelter

· Shall be corrosion resistant

· Shelter:

· Shall include at least 30” wide x 80” high personnel door

· Shall include at least 14 insulated windows

· Shall have fire resistant fabric that meets NFPA 701 and ASTM D6413

· Shall be designed to allow one shelter to attach to another shelter

· Ends:

· End base frame sections shall be removable so it can be used to connect other shelters

· Shall include two sets of 18” diameter ECU/HVAC ports

· Floor:

· Shall have non-slip vinyl floor

· Shall attach and seal to the cover and end walls

· Electrical:

· Single-phase power distribution box

· 2 EA Ground-fault circuit interrupter (GFCI) 20-amp breakers

· 2 EA 20-amp breakers

· 4 EA Twist lock cable connectors

· 1 EA Light switch

· At least 2 EA outlet lines with 12 receptacles per line, with a total of 24 outlets

· At least 6 EA incandescent light bulbs

· At least 1 EA 50’ power cable

· Shall withstand at least 60 mph wind load per ASCE 7-10

· Shall meet at least 20 psf ground snow load per ASCE 7-10

File details come from the government source that posted it.