COMBINED SYNOPSIS/SOLICIATION ‘COMBO’:
Deutz Mounting Kits
(i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
(ii) Solicitation FA5000-16-T-0197 is issued as a Request for Quote (RFQ).
(iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-89, effective 15 Aug 2016. The DFARS provisions and clauses are those in effect to DPN 20160811, effective 11 Aug 2016. The AFFARS provisions and clauses are those in effect to AFAC 2016-0603, effective 03 Jun 2016.
(iv) This requirement is solicited as a 100% Small Business Set-Aside. The North American Industrial Classification System (NAICS) code associated with this procurement is 332999 with a small business size standard of 750 employees.
(v) The Pricing Schedule is incorporated as Attachment 1. Vendors shall complete Attachment 1 in its entirety and return with any other documentation/data as required by this Combo.
(vi) The Government intends to award a Firm-Fixed Price contract for the following:
See Attachment 1: Pricing Schedule
(vii) Delivery shall be FOB Destination with a delivery period of 6 Weeks After Receipt of Order (ARO). Contractor shall include delivery schedule information on the Pricing Schedule, Attachment 1. All items shall be delivered to: Joint Base Elmendorf-Richardson, Anchorage, Alaska 99506
(viii) FAR 52.212-1 Instructions to Offerors -- Commercial Items (Oct 2015) is hereby incorporated by reference, with the same force and effect as if it were given in full text. In addition to the following addendum, all terms and conditions of FAR 52.212-1 remain in effect.
The following have been tailored to this procurement and are hereby added via addendum:
1. To assure timely and equitable evaluation of the quote, the vendors must follow the instructions contained herein. The quote must be complete, self-sufficient, and respond directly to the requirements of this solicitation.
2. Specific Instructions: The response shall consist of two (2) separate parts:
a. Part 1- Technical Acceptability - Submit one (1) copy of a technical description of the items being offered in sufficient detail to evaluate compliance with the requirements.
b. Part 2- Price – Submit one (1) copy of price schedule and any pertinent additional information.
3. Award will be made to the vendor whose quote is conforming to the solicitation and is determined to be the lowest price technically acceptable. Technical Acceptability, at a minimum, is defined as meeting all of the criteria and specifications in Attachment 1. Price and technical acceptability will be considered.
(ix) FAR 52.212-2 Evaluation -- Commercial Items (Oct 2014) this provision has been tailored to this procurement and is provided in full-text below:
(a) The Government will award a contract resulting from this solicitation to the responsible vendors whose quote conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate quotes:
(i) Technical acceptability
(ii) Price
(b) Price and technical acceptability will be considered. The Government intends to evaluate quotes and award without discussion, but reserves the right to conduct discussions. Therefore, the vendor’s initial quote should contain the vendor’s best terms from a price and technical standpoint. The lowest priced quote will be evaluated for technical acceptability. If the quote is found technically acceptable, award will be made without further consideration. If it is found technically unacceptable, the Government will evaluate the next lowest quote for technical acceptability until award can be made to the lowest priced technically acceptable vendors.
Therefore, the vendor’s initial quote should contain the vendor’s best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions if later determined by the Contracting Officer to be necessary. Quotes that fail to furnish required representations or information, or reject the terms and conditions of the solicitation may be excluded from consideration.
(c) This will be a lowest priced, technically acceptable purchase. Technical acceptability – at a minimum, is defined as meeting all of the following criteria:
Minimum Qualifications: Contractor must be able to provide the products described herein (see Attachment 1).
(d) A written notice of award or acceptance of a quote mailed or otherwise furnished to the successful vendor within the time for acceptance specified in the quote, shall result in a binding contract without further action by either party. Before the quote’s specified expiration time, the Government may accept a quote (or part of a quote), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of Provision)
(x) Each vendors shall ensure the provision at FAR 52.212-3 including its Alternate I, Vendors Representations and Certifications--Commercial Items (Jul 2016), are updated at www.sam.gov.
Failure to obtain SAM registration will result in submissions not being considered for award.
(xi) The clause at FAR 52.212-4, Contract Terms and Conditions – Commercial Items (May 2015), is hereby incorporated by reference, with the same force and effect as if it were given in full text.
(xii) The clause at FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders – Commercial Items (Jun 2016), is hereby incorporated by reference, with the same force and effect as if it were given in full text. Additionally, the following clauses apply to this acquisition:
FAR 52.204-7 Data Universal Numbering System Number Jul 2013
FAR 52.204-10
Reporting Executive Compensation and First-Tier Subcontract Awards
Oct 2015
FAR 52.204-16 Commercial and Government Entity Code Reporting Jul 2016
FAR 52.204-18 Commercial and Government Entity Code Maintenance Jul 2016
FAR 52.204-19 Incorporation by Reference of Representations and Certifications
Dec 2014
FAR 52.209-6 Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment
Oct 2015
FAR 52.209-10 Prohibition on Contracting with Inverted Domestic corporations
Nov 2015
FAR 52.219-6 Notice of Total Small Business Set-Aside Nov 2011 FAR 52.219-28 Post-Award Small Business Program Representation Jul 2013 FAR 52.222-3 Convict Labor Jun 2003 FAR 52.222-19 Child Labor -- Cooperation with Authorities and Remedies Feb 2016 FAR 52.222-21 Prohibition of Segregated Facilities Apr 2015 FAR 52.222-26 Equal Opportunity Apr 2015 FAR 52.222-36 Equal Opportunity for Workers with Disabilities Jul 2014 FAR 52.222-50 Combating Trafficking in Persons Mar 2015 FAR 52.223-18 Encouraging Contractor Policies to Ban Text Messaging While
Driving Aug 2011
FAR 52.225-3 Buy American Act--Free Trade Agreements--Israeli Trade Act May 2014 FAR 52.225-13 Restrictions on Certain Foreign Purchases Jun 2008 FAR 52.225-25 Prohibition on Contracting with Entities Engaging in Certain
Activities or Transactions Relating to Iran—Representations and Certifications.
Oct 2015
FAR 52.232-33 Payment by Electronic Funds Transfer – System for Award Management
Jul 2013
FAR 52.232-39 Unenforceability of Unauthorized Obligations Jun 2013 FAR 52.232-40 Providing Accelerated Payments to Small Business
Subcontractors Dec 2013
FAR 52.233-1 Disputes May 2014 FAR 52.233-3 Protest After Award Aug 1996 FAR 52.233-4 Applicable Law for Breach of Contract Claim Oct 2004 FAR 52.247-64 & Alt I Preference for Privately Owned U.S. - Flag Commercial
Vessels & Alt I Feb 2006 & Apr 2003
DFARS 252.203-7000 Requirements Relating To Compensation of Former DoD Officials
Sep 2011
DFARS 252.203-7002 Requirement to Inform Employees of Whistleblower Rights Sep 2013
DFARS 252.203-7005 Representation Relating To Compensation of Former DoD Officials
Nov 2011
DFARS 252.204-7008 Compliance with Safeguarding Covered Defense Information Controls
Dec 2015
DFARS 252.204-7011 Alternative Line Item Structure Sep 2011 DFARS 252.204-7012 Safeguarding of Unclassified Controlled Technical Information Dec 2015 DFARS 252.204-7015 Disclosure of Information to Litigation Support Contracts May 2016 DFARS 252.211-7003 Item Identification and Valuation Mar 2016 DFARS 252.211-7008 Use of Government-Assigned Serial Numbers Sep 2010 DFARS 252.223-7008 Prohibition of Hexavalent Chromium Jun 2013 DFARS 252.225-7000 Buy American Statute—Balance of Payments Program
Certificate Nov 2014
DFARS 252.225-7001 Buy American and Balance of Payments Program Aug 2016 DFARS 252.225-7002 Qualifying Country Sources as Subcontractors Aug 2016 DFARS 252.225-7048 Export-Controlled Items Jun 2013 DFARS 252.232-7003 Electronic Submission of Payment Requests and Receiving
Reports Jun 2012
DFARS 252.232-7006 Wide Area Workflow Payment Instructions May 2013 DFARS 252.232-7010 Levies on Contract Payments Dec 2006 DFARS 252.244-7000 Subcontracts for Commercial Items Jun 2013 DFARS 252.247-7023 Transportation of Supplies by Sea Apr 2014 AFFARS 5352.201-9101 Ombudsman Jun 2016
(xiii) No additional contract requirements apply to this acquisition.
(xiv) No Defense Priorities and Allocations System (DPAS) assigned rating applies to this acquisition.
(xv) NOTICE TO ALL INTERESTED PARTIES:
Questions shall be submitted to the following personnel:
Please forward all questions to Joshua Jordan at joshua.jordan@us.af.mil no later than 10AM AKST on 19 September 2016. An amendment will be issued providing the Government’s answers to any questions received.
Quotes are due no later than 10AM AKDT on 21 September 2016. Quotes shall include the following:
a. Part 1- Technical Acceptability - Submit one (1) copy of technical acceptability narrative.
b. Part 2- Price – Submit one (1) copy of price schedule as well as any additional pertinent information
BASIS OF CONTRACT AWARD: This is a competitive action in which award shall be made to the lowest priced, technically acceptable quote.
(xvi) Quotations shall be submitted to Joshua Jordan at joshua.jordan@us.af.mil. For information regarding this solicitation, contact the same.
List of Attachments:
Attachment 1: Pricing Schedule Attachment 2: DFARS 252.209-7991 Attachment 3: Statement of Work Attachment 4: Designs/Drawings & Technical Orders
FA5000-16-T-0197
Attachment 1: Pricing Schedule
LINE
ITEM
DESCRIPTION QTY UI
UNIT
PRICE
EXTENDED
PRICE
0001: Complete set of Mounting Kits—See attached Statement of Work (Attachment 3)—See attached designs/drawings and
Technical Orders (Attachment 4)
16 EA
TOTAL PRICE:
***Shipping costs to JBER, Alaska 99506 MUST be included within the unit price.*** ***Quotes must be good for a minimum of 60 days from close of solicitation***
Vendors may, at their discretion, provide additional time. THIS QUOTE EXPIRES ON: _________________________ Business Size: �Small �Large �Women-Owned �Veteran-Owned �Other:__________________________
Delivery Date (Mandatory): Net Terms (Mandatory):
DUNS:
Printed Name Title
Signature Date NOTE: The individual signing must be a signatory official for this Entity; signature constitutes agreement to all terms/conditions contained within this solicitation.
Attachment 2 DARS Tracking Number: 2016-O0002
Class Deviation—Prohibition Against Using Fiscal Year 2016 Funds to Contract with Corporations that Have an Unpaid Delinquent Tax Liability or a Felony Conviction under Federal Law
252.209-7991 Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony Conviction under any Federal Law—Fiscal Year 2016 Appropriations.
REPRESENTATION BY CORPORATIONS REGARDING AN UNPAID DELINQUENT TAX
LIABILITY OR A FELONY CONVICTION UNDER ANY FEDERAL LAW—FISCAL YEAR
2016 APPROPRIATIONS
(DEVIATION 2016-OO0002) (OCT 2015)
(a) In accordance with section l0l (a) of the Continuing Appropriations Act, 2016 (Pub. L.
114-53) and any subsequent FY 2016 appropriations act that extends to FY 2016 funds the same restrictions as are contained in sections 744 and 745 of division E, title VII, of the consolidated and Further Continuing Appropriations Act, 2015 (Pub. L. 113-235), none of the funds made available by this or any other Act may be used to enter into a contract with any corporation that—
(1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless the agency has considered suspension or debarment of the corporation and made a determination that this further action is not necessary to protect the interests of the Government; or
(2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless the agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government.
(b) The Offeror represents that—
(1) It is [ ] is not [ ] a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability,
(2) It is [ ] is not [ ] a corporation that was convicted of a felony criminal violation under a Federal law within the preceding 24 months.
(End of provision)
STATEMENT OF WORK (SOW)
9 March 2016 Barrier Engine Kits
1. SCOPE: This is a contract to provide Deutz engine mounting kits. The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to provide Deutz engine mounting kits as defined in this SOW.
2. APPLICABLE DOCUMENTS: T.O. 35E8-2-5-3 Paragraphs 5.21, and Appendix C 100-2
3. REQUIREMENTS: The Contractor will provide Deutz engine mounting kits containing the following:
3.1.1. Engine stand 2 each
3.1.2. Control panel stand 1each
3.1.3. Gauge panel 1 each
3.1.4. Flat plate 1 each
3.1.5. Angle bracket 1 each
3.1.6. All items will be inspected and tested for lead paint prior to sandblasting and painting
3.1.7. Paint color will be in accordance with T.O. 358-2-5-3 Paragraph 5.21 and Appendix C 100-2.
3.1.8. All Items need to be fabricated and painted and returned within six (6) weeks of Delivery Order to include transportation time to and from the vendor
3.2. Place of Performance:
3.2.1. Work to be performed under this contract will be performed at a non-government owned facility.
Attachment 3
5.21 BASE.
Proceed as follows:
a. Sandblast if paint is chipped, or base is corroded.
b. Prime and repaint.
5.22 REEL ASSEMBLY.
Proceed as follows:
a. If 66-inch sideplates, inspect. If corroded, or worn, discard.
b. Inspect sprocket. If worn, replace. If good, replace re-wind bushing, and reuse.
c. If 66-inch reels, strip off phenolics from restraining rings; then clean, paint and install new phenolic wear strips.
5.23 REEL ASSEMBLY - TAPE DRUM RING.
Cracking may occur on any surface area with particular at-tention to areas around threaded bolt hole surfaces: (see Fig-ure 5-4.)
5.23.1 Primary NDI Procedure - Eddy Current:.
a. NDI Equipment:
(1) Eddy current inspection unit: Staveley Nortec 2000D.
(2) Probe, 90° angle surface, shielded, 1/8-inch di-ameter, frequency range to include 200kHz, dif-ferential with a 4 pin fischer connector.
b. Follow locally established safety instructions.
c. No special access required.
d. Tape Drum Ring shall be removed from the assembly before inspection.
e. Clean part as necessary to permit suitable contact be-tween part and probe.
NOTE
Penetrant inspection is impractical on porous ma-terials, various types of anodized aluminum sur-faces, or other protective coatings on other metals.
Penetrant rapidly enters the pores of the material and becomes trapped. This can result in back-ground that reduces contrast or can mask any po-tential discontinuity indications. In addition re-moval of the penetrant may not be possible after the inspection.
f. See General Eddy Current supplement, Surface Scan Aluminum.
g. Aluminum surface inspection.
NOTE
In order to protect the probe from wear and dam-age, it is recommended that teflon tape be applied to the contact surface of the probes - PN 3M 5480, maximum thickness 0.005”. This practice also helps to reduce noise.
(1) Surface Scan Inspection.
(2) Perform inspection around the circumference of each threaded bolt hole both inner and outer sur-face areas of the tape drum ring (see Figure 5-6.
NOTE
If the inspection surface of the aluminum casting is porous to the extent of being unable to perform the required eddy current inspections a flashlight and magnifying glass may be used to accomplish the inspection.
h. Backup inspection: Not required.
i. Acceptance/Rejection: No cracks are permitted. If cracks are found, mark with approved marking mate-rial and report to 642 CBSS/GBZO - ENI engineering.
j. Clean inspection materials from inspected areas. If re-quired, have protective finishes restored and compo-nents reinstalled in accordance with applicable TO.
TO 35E8-2-5-3
5-17
Attachment 4
APPENDIX C
PROCESS SPECIFICATION
PS100
NOTE
Finish per PS (Process Specification) as follows:
100-1 (ALUMINUM PARTS).
• Oakite/carbon remover rust stripper is toxic to eyes, skin and respiratory tract. Oakite may ig-nite organic materials, nitrates, carbides, and chlorates. Chemical goggles and neoprene gloves will be worn. Good general ventilation is normally adequate. If in doubt of safety or health measures, contact assigned Bioenviron-mental Engineer prior to use.
• Alodine/Chemical Film may affect skin, eyes and respiratory tract. Chemical goggles and neoprene gloves will be worn. Use in a well ventilated area.
• MIL-P-23377, Type I, Class 2, OR MIL-P- 85582 may affect skin, eyes, and respiratory tract. Chemical goggles and neoprene gloves shall be worn. Use in a well ventilated area;
avoid eye and skin contact.
• Paints, primers, lacquers and varnishes must be handled carefully and used only in well venti-lated approved areas. Avoid prolonged breath-ing of vapors. Avoid eye and repeated skin con-tact. Keep away from sparks and flames.
Respirator use is required unless waived by the Base Bioenvironmental Engineer.
m. Clean -- “Oakite” #33 or equal.
n. Chemical conversion film -- brush, dip or spray -- “Oakite Chromicoat” or equal.
o. MIL-P-23377, Type I, Class 2, or MIL-P-85582.
p. Paint -- Two coats marine green semigloss enamel (M.A.B. or equal).
100-2 (STEEL PARTS).
NOTE
Far steel materials, one of the fallowing point methods may be applied to the Fairlead Beam or Bak-12/MAAS during overhaul.
q. Finish in accordance with Air Farce drawing number 7545352, Abrasive blast to a near white blast cleaned surface finish per Steel Structures Paint Council 55PC-SP 10-85. Prime with an organic zinc rich primer.
Approved primers are listed in Air Force drawing number 7545352, The dry film thickness of the primer coating shall be 2.0 to 3.0 mils. Topcoat with MIL- PRF-85285 polyurethane. Refer to QPL-C-85285 for approved coatings. Color shall be color number 24057 per FED-STD-595,
r. Finish in accordance with Sherwin Williams Zinc Clod IV (3.0-5.0 mils dry film thickness) followed by one to two coots of Sherwin Williams Acrolon 218 HS poly-urethane topcoat (3.0-6.0 mils dry film thickness). Fol-low the manufacturer’s recommendations for surface preparation and coating application.
100-3 (STEEL PARTS).
s. Finish in accordance with Air Farce drawing number 7545352, Abrasive blast to a near white blast cleaned surface finish per Steel Structures Paint Council 55PC-SP 10-85. Prime with an organic zinc rich primer.
Approved primers are listed in Air Force drawing number 7545352, The dry film thickness of the primer coating shall be 2.0 to 3.0 mils. Topcoat with MIL- PRF-85285 polyurethane. Refer to QPL-C-85285 for approved coatings. Color shall be color number 24057 per FED-STD-595,
t. Finish in accordance with Sherwin Williams Zinc Clod IV (3.0-5.0 mils dry film thickness) followed by one to two coots of Sherwin Williams Acrolon 218 HS poly-urethane topcoat (3.0-6.0 mils dry film thickness). Fol-low the manufacturer’s recommendations for surface preparation and coating application.
TO 35E8-2-5-3
C-1
4.000
.250
6.020
1.750
1.063
3.021
1.063
.437
.437
1/4" A-36
FOR SAW ONLY
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
ENGINE MNT FOOT
DO NOT SCALE DRAWING
.439 .272
.148
.167
.291
2.950 .167
.439
2.950
1.620
2.335
.609
.270
.609
.270
.403
1.630
.815
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/16
ANGULAR: MACH .1 BEND 1.0
TWO PLACE DECIMAL .030
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 2:1
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
ADJUSTER BRACKET
2.750
.125
SLOTS ON ITEM 3 MUST LINE UP
WITH ITEM 1 BEFORE WELDING
.125
.125
.125 3 SIDES
.125 3 SIDES
W-6 X 20 A-36
WELDING PRINT
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 FWRD ENGINE MOUNT 1
2 FWRD ENG MNT JACK
SCREW LUG 1
3 ENGINE MNT FOOT 2
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/16
ANGULAR: MACH .1 BEND 1.0
TWO PLACE DECIMAL .030
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:4
UNLESS OTHERWISE SPECIFIED:
Tim C. 1-18-13
SHEET 1 OF 1
FWRD ENG. MNT ASSY.
1.282
1.437
2 PLCS
.563
2 PLCS
20.437
1.250
2 PLCS
9.250
.500
3/8-16 Tapped Hole 27.000
38.00°
6.000
11.250
29.000
6.200
4.000
6.020
7.000
10.500
4.500
1.750
25.500
.968
2 PLCS
TYP
3.021
2 PLCS.
TYP
1.063
4 PLCS.
TYP
.437
4 PLCS
TYP
10-32 TAPPED THRU
3 PLCS
W6 X 20#
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:8
UNLESS OTHERWISE SPECIFIED:
Tim C. 3-28-14
SHEET 1 OF 1
FWRD ENGINE MOUNT
201018917
12.000
19.000
27.000
1.437
2 PLCS
.563
2 PLCS 1.282
1.250
2 PLCS
20.437
27.000 2.250
16.000
6.200
#10-24 Tapped Hole Thru
6.200
6.020
4.000
1.690
24.500
1.500
TYP. 2 PLCS 3.021
TYP. 2 PLCS
1.063
TYP. 4 PLCS
.437
TYP. 4 PLCS
W6 X 20#
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:6
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
AFT ENG. MNT
201018918
6.020
1.063
2 PLCS
.437
2 PLCS
3.021
.810
.968
6.020
.250
1/4" A-36
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
AFT ENG FRNT MNT
2.750
.125
SLOTS MUST LINE UP ON ITEM 1
WITH ITEM 2&3 BEFORE WELDING
.125
.125
.125 3 SIDES
.125 3 SIDES
ITEM
NO. PART NUMBER DESCRIPTION QTY.
1 AFT ENG. MNT 1
2 AFT ENG FRNT
MNT 1
3 AFT ENG
REAR MNT 1
4 JACK SCREW
LUG 1
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:6
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
AFT ENG MNT WELD ASSY
6.020
1.063
2 PLCS
.437
2 PLCS
3.021
.968
1.689
2 PLCS .250
1/4 A-36
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
AFT ENG REAR MNT
1.000 2.000
2.000
.750
5/8-11 UNC 2B
1018 C.R.
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32
ANGULAR: MACH 1.0 BEND 2.0
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME TITLE:
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
Tim C.
SHEET 1 OF 1
JACK SCREW LUG
| Numbered drawings.pdf |
| numbered drawings 001 |
| numbered drawings 002 |
| numbered drawings 003 |
| numbered drawings 004 |
| numbered drawings 005 |
| numbered drawings 006 |
| numbered drawings 007 |
| numbered drawings 008 |
| numbered drawings 009 |
| numbered drawings 010 |
| Missing drawings.pdf |
| Missing Drawings 001 |
| Missing Drawings 002 |
| Missing Drawings 003 |
| Missing Drawings 004 |
| Missing Drawings 005 |
| Missing Drawings 006 |
| Missing Drawings 007 |
| Missing Drawings 008 |
| Missing Drawings 009 |
| Missing Drawings 010 |
| Missing Drawings 011 |
| Missing Drawings 012 |
File details come from the government source that posted it. Updated .