Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION
NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.
IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
NSN 7540-01-152-8070
Previous edition unusable
FA5000
JOSHUA JORDAN, TSgt USAF
1. The purpose of this Amendment is to add more items to the requirement and to add clarifications to the drawings and designs in the solicitation, as well as update units on the drawings themselves.
2. All offerors shall return this amendment with Blocks 8, 15A, 15B and 15C completed in their entirety. This amendment shall be returned with the offeror's offer. This will serve as the offeror's receipt and acknowledgment of the amendment. No other proof or acknowledgment is required.
673d Contracting Squadron / LGCC 10480 Sijan Avenue, JBER, AK 99506
(See item 6)
FA5000-16-T-0171
1 7
09/06/2016
08/25/2016
1030155056A Typewritten Text
1030155056A Typewritten Text
1030155056A Typewritten Text 6 Sep 2016
4’ 6.25”
Operations floor raised (except step ups) ‐6’
2’2.5’’
Main Entrance
Rear Entrance
CAO: 02 SEP 16
4’
18”
2’5.5’’
SLOW RISE RAMP
3’1”
13’5”
8”1’
3’1”
3’11.5”
Windows – 12’6.5”
Alaska Rescue Coordination Center, Operations Floor
13’4.5’’
4’.5”
9’1"
6’11.5”
14’10.5”7’5”15’4”
Windows – 12’6.5”
AKRCC CONSOLES
REQUIREMENTS (CAO 02 SEP 16)
COCKPIT CONSOLES + BRIDGE (ILLUSTRATIONS #1‐3)(OVERALL REQUIREMENTS)
1) CONSOLE & BRIDGE WILL NOT EXCEED 18’ X 6’ TO ACCOMMODATE OPS FLOOR MOVEMENT
2) 12” SLATWALL
3) SIX – (6) SIX OUTLET POWER BARS, 15’ POWER CORD, MUST BE HIDDEN WITHIN CONSOLE AND
BRIDGE. POWER BARS MUST BE ACCESSIBLE FROM ALL CONSOLES AND BRIDGE
4) REPLACEABLE WATERFALL NOSING ON FRONT OF ALL DESKTOP WORK SURFACES
5) A STRUCTURAL STEEL OR ALUMINUM FRAMEWORK MUST BE PROVIDED WITH FULL UNDERSURFACE
EQUIPMENT ENCLOSURES THAT LOCK EACH ELEMENT OF THE CONSOLE SUBSURFACE INTO A
CONTIGUOUS WHOLE, STABILIZING ALL MOVEMENT. (NOT REQUIRED FOR MILLWORK ON BRIDGE)
6) 10 (TEN) MONITOR ARMS ‐ MUST HAVE ABILITY TO MOUNT TO THE SLATWALL. ARMS MUST BE
INCLUDED WITH CONSOLES, AND MUST BE COVERED UNDER WARRANTY FOR A MINIMUM OF 5
YEARS. THE CONSOLE MANUFACTURER MUST ALSO MANUFACTURE THE ARMS TO ENSURE A
SEAMLESS REPLACEMENT SOURCE FOR FUTURE CHANGE. MONITOR ARMS SHOULD PROVIDE
ARTICULATION FORWARD AND BACK, AS WELL AS HEIGHT ADJUSTMENT. MUST BE ABLE TO HOLD A
MINIMUM OF 40 LBS.
COCKPIT CONSOLES (ILLUSTRATIONS #1‐3) (TWO REQUIRED) (REQUIREMENTS FOR EACH UNIT)
1) MUST HAVE ABILITY TO RAISE FROM SITTING TO STANDING POSITION
2) ABILITY TO MOUNT (4) FOUR 24” INCH MONITORS WITH ADJUSTABLE MONITOR ARMS
3) DUAL CABLE MANAGEMENT SYSTEM, MUST BE ABLE TO TRAVEL AT SITTING AND STANDING
POSITION WITH NO CABLE KINKING
4) ABILITY TO HOLD AND HIDE (3) THREE STANDARD DESKTOP COMPUTERS AND CABLING WITHIN
CONSOLE. MUST HAVE FRONT AND REAR ACCESS TO EACH
5) (2) TWO SETS OF POWER OUTLETS INSTALLED ON SLATWALL
6) (1) ONE ADJUSTABLE LED TASK LIGHT, MUST BE ABLE TO ADJUST INTENSITY, 3 YEAR WARRANTY.
MUST BE ABLE TO MOUNT ON SLATWALL
7) CLEAR AREA BELOW DESKTOP TO MOUNT 16” X 7” X 1'” PHONE/RADIO MANAGEMENT HARDWARE
(SDAP)
(ILLUSTRATION #1)
(BRIDGE)
NOTE: This document replaces the first version provided in the original solicitation.
ILLUSTRATIONS 2‐4
CONSOLE BRIDGE (ILLUSTRATIONS #1‐3) (ONE REQUIRED)
1) BRIDGE
a. 48” IN LENGTH
b. NO REQUIREMENT TO RAISE TO STANDING POSITION
c. ABILITY TO MOUNT (2) TWO 24” INCH MONITORS WITH ADJUSTABLE MONITOR ARMS
d. ABILITY TO HOLD AND HIDE (2) TWO STANDARD DESKTOP COMPUTERS AND CABLING
WITHIN CONSOLE. MUST HAVE FRONT AND REAR ACCESS TO EACH
e. (1) ONE POWER OUTLET INSTALLED ON SLATWALL
f. (1) ONE ADJUSTABLE LED TASK LIGHT, MUST BE ABLE TO ADJUST INTENSITY, 3 YEAR
WARRANTY. MUST BE ABLE TO MOUNT ON SLATWALL
g. (UNDERNEATH STORAGE)
i. (4) FOUR 4” PULL OUT DRAWERS (TOP)
ii. (2) TWO 6” HIGH SHELVES, (MIDDLE). ACCESS HOLES TO POWER BARS
iii. (4) FOUR 11” WIDE BY 12” HIGH SHELVES (BOTTOM). ACCESS HOLES AT REAR TO
POWER BARS
iv. STORAGE UNIT MUST ALLOW A MINIMUM OF SIX INCHES CLEARANCE FROM
DESKTOP WATERFALL NOSING TO FRONT OF STORAGE CABINET
LINEAR CONSOLES (ILLUSTRATION #4) (TWO CONSOLES REQUIRED) (REQUIREMENTS FOR EACH UNIT)
1) ABILITY TO RAISE FROM SITTING TO STANDING POSITION
2) 12” SLATWALL
3) A STRUCTURAL STEEL OR ALUMINUM FRAMEWORK MUST BE PROVIDED WITH FULL UNDERSURFACE
EQUIPMENT ENCLOSURES THAT LOCK EACH ELEMENT OF THE CONSOLE SUBSURFACE INTO A
CONTIGUOUS WHOLE, STABILIZING ALL MOVEMENT.
ILLUSTRATIONS #2‐3
ILLUSTRATION #1
ILLUSTRATION #4
4) 4 (FOUR) MONITOR ARMS ‐ MUST HAVE ABILITY TO MOUNT TO THE SLATWALL. ARMS MUST BE
INCLUDED WITH CONSOLES, AND MUST BE COVERED UNDER WARRANTY FOR A MINIMUM OF 5
YEARS. THE CONSOLE MANUFACTURER MUST ALSO MANUFACTURE THE ARMS TO ENSURE A
SEAMLESS REPLACEMENT SOURCE FOR FUTURE CHANGE. MONITOR ARMS SHOULD PROVIDE
ARTICULATION FORWARD AND BACK, AS WELL AS HEIGHT ADJUSTMENT. MUST BE ABLE TO HOLD A
MINIMUM OF 40 LBS.
5) CONSOLE WILL NOT EXCEED 8’’ X 48” TO ACCOMMODATE OPS FLOOR MOVEMENT
6) DUAL CABLE MANAGEMENT SYSTEM, MUST BE ABLE TO TRAVEL AT SITTING AND STANDING
POSITION WITH NO CABLE KINKING
7) DESKTOP MUST HAVE INWARD FRONT CURVE
8) (3) THREE OUTLET POWER BARS, 15’ POWER CORD, MUST BE HIDDEN WITHIN CONSOLE AND HAVE
ACCESS THROUGHOUT CONSOLE
9) ABILITY TO HOLD AND HIDE (2) TWO STANDARD DESKTOP COMPUTERS AND CABLING WITHIN
CONSOLE. MUST HAVE FRONT AND REAR ACCESS TO EACH
10) (1) ONE POWER OUTLET INSTALLED ON SLATWALL
11) (1) ONE ADJUSTABLE LED TASK LIGHT, MUST BE ABLE TO ADJUST INTENSITY, 3 YEAR WARRANTY.
MUST BE ABLE TO MOUNT ON SLATWALL
12) CLEAR AREA BELOW DESKTOP TO MOUNT 16” X 7” X 1'” PHONE/RADIO MANAGEMENT HARDWARE
(SDAP)
13) REMOVABLE WATERFALL NOSING ON FRONT OF DESKTOP WORK SURFACES
14) THREE STORAGE DRAWERS INSTALLED ON ONE SIDE OF CONSOLE (BUILT INTO UNIT)
ILLUSTRATION #5‐6
ILLUSTRATIONS #7‐8
PRINTER CABINET (ILLUSTRATIONS #5‐6) (ONE REQUIRED)
1) 42” X 25”
2) ADJUSTABLE SHELVING INSIDE WITH OUTER DOORS ON ONE SIDE
3) WATERFALL NOSING ON OUTER WORK SURFACES (NOT REQUIRED ON REAR)
PLANNING TABLE (ILLUSTRATIONS #7‐8) (ONE REQUIRED)
1) 72” X 42”
2) ADJUSTABLE SHELVING INSIDE WITH OUTER DOORS ON BOTH 72” SIDES
3) WATERFALL NOSING ON ALL DESKTOP OUTER WORK SURFACES
| 2016-09-06T11:26:12-0800 | |
| JORDAN.JOSHUA.JEREMIAH.1030155056 |
File details come from the government source that posted it. Updated .