SCALE

FACILITY

HTR

F

UB T

I

TSR

OF

U

DATE

SHEET

DRAWN BY

OF

PROJECT NUMBER

DRAWING NUMBER

PR

O

JE

C

T

TI

TL

E

D R

AW

IN

G S

H

EE

T N

AM

E

THU

N

IT

ED

S

TA

TE

S

AI

R

F O

R C

E

C

IV

IL

E N

G

IN

EE

R

S Q

U

AD

R O

N

SE

YM

O

U R

J O

H N

SO

N

A

IR

F O

R C

E

BA

SE

, N

O R

TH

C

AR

O

LI

N

A

PR

O

JE

C

T

PH

AS

E

C O

N

TR

AC

T

N o.

TA

SK

O R

D

ER

N o.

AP

PR

V' D

D

AT

E D

ES

C

R

IP

TI

O

N R

EV

1 2 3 4 5 6 7 8 9 10 11

A

B

C

D

E

F

G

7 8 9 10 111 2 3 4 5 6

H

A

B

C

D

E

F

G

H p:\2017\17077_seymourjohnsonafb_bldg4901\17077_drawings\VKAG 13-9007 A201.dwg

12 SEPTEMBER 2018

AS-SHOWN

B.S.S.

9117A201

VKAG 13-9007

R

EP

AI

R

B

LD

G . 4

TO

H

O U

SE

AR

W /O

G

O

VE

R

AL

L R

EN

O

VA

TI

O N

F

LO

O R

P

LA

N

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

W

8-

-D

-0

W

2H N

-1 7-

F-

9/

/2

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

8/

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

6/

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

3 2 1

VKAG

SCALE:

OVERALL RENOVATION FLOOR PLAN

A201 A1

1/8" = 1'-0"

N0 4' 8' 16'

OSX/OSK

RENOVATION PLAN LEGEND

ROOM NUMBER

ROOM NAME

STC-45 RATED WALLS (EXISTING

OR PROPOSED)

SEE SHEET A202 FOR

RENOVATION KEY NOTES

ROOM CONSTRUCTED TO CN551

4005 STANDARDS STC-45 RATED

WALLS (ROOM 18B ONLY)

E

EXISTING EXTERIOR WALL, SEE

SHEET A601 FOR ADDITIONAL

INFORMATION

NEW INTERIOR WALL OR

PARTITION, SEE SHEET A602 FOR

ADDITIONAL INFORMATION

EXISTING WALL OR PARTITION

NEW CMU WALL / CMU INFLL

NEW INTERIOR WALL OR

PARTITION

STC-50 RATED WALLS

(EXISTING OR PROPOSED)

X

8'-0" HIGH CHAIN LINK FENCING WITH

3 STRAND BARBED WIRE (PROVIDED

8' LONG VINYL SLATS AT ALL CHAIN

LINK MESH.

DOWNSPOUT LOCATION, SEE SHEET

A401 FOR ADDITIONAL INFORMATION

X

WINDOW NUMBER, SEE SHEET A701

DOOR NUMBER, SEE SHEET A702

X X X X X

X X

X X

X X

X X

X X

X X

08A

19'-0" 24'-8"

'-8

" 26 '-8

20'-4"15 '-4

5'-8" 26'-10"

27'-2"

'-0

20'-6" 12'-10"

9' -1

0" 9'

-1 0"

8'-7"

14'-5"

'-8

5'

-0

23'-6"

'-6

7'-0" 11'-0" 11'-4" 11'-0" 7'-0" 7'-0"

'-6

9'-8"

'-4

15'-0"

'-0

12'-0"

8' -0

25'-4"

32'-2"

37'-8"

4' -8

'-0

22'-61 2"22'-61

2"

3'-4"

26'-4"

'-8

26'-4" 30'-4"

'-0

'-8

31'-4"

'-4

'-4

09A

08B

07060504

03B03A

01.2

01.114

1517 16

18A18

18B

192022

42A

25A

30.2

26.2 29.1

40.2

40.1

30.1

26.1

A205

OG EXEC2

08C

OG SEC

OG CC

OG EXEC

08D

CORRIDOR

BREAK

ROOM

OSS CC

03A

SEC

OSS DO

03B

OSS

1ST SGT

OG CHEIF

OG

UDM/CEA

RA

07A

UTM

07B

OSS

ADMIN

CONFERENCE

ROOM

OSX/

OSK PLANS

LOBBY

MECHANICAL

IT EQUIP

WOMEN

CUST.

MEN

CREW COMM

SUPER

18A

CORRIDOR

01A

COMBAT CREW

COMM - OPEN OFFICE

OSX / OSK

BRIEF ROOM

MANTRAP

CORRIDOR

LOCKERS

01B

OIC + NCOIC +

SUPER

KITCHEN

HALL

34A

SHOWER

TOILET

CMF STORAGE

SAFE / SIPR /

TRAINING

18B

ISS

BAG ISSUE

INTEL

BRIEF ROOM

INTEL

LOCKERS/

SHOWER

SR ART / ADMIN SUPPORT /

SORTS / TRAINING

S/O OFFICE

IN

TE

L

ST

OR

AG

E

A

EA CELL

FRAME ROOM

CORR.

MECHANICAL

TOILET

CAT + SUPPORT

BATTLE STAFF

HALL

TOILET

25A

MECHANICAL YARD

RESTRICTED AREA

BATH

09A

A205

'-8

4'-10"

'-8

'-0

CORR.

10'-0"

OG CD

08B

10'-0"

CLOSET

08A

31'-4"

6'-2" 41'-6"

29.2 29'-4"

M

AT

C H

L

IN

E

- B

MATCH

LINE - A

A206

A205

A205

M

AT

C H

L

IN

E

- B

A205

A205

19'-0"

24'-6"

3'-2"

COP

38A38A

'-0

'-8

'-0

35'-0" 26'-8"

DS

DS

DS

DS

DS DS DS DS DS DS

DS

DS DS DS DS

DS

6' -0

6' -0

'-4

28'-8"

DS

DS DS DS DS DS

DS

DS

DS

DS

6' -2

'-6

DS DS DS DS

DS

X X

DS

HTR

F

UB T

I

TSR

OF

U

DATE

SHEET

DRAWN BY

OF

PROJECT NUMBER

DRAWING NUMBER

PR

O

JE

C

T

TI

TL

E

D R

AW

IN

G S

H

EE

T N

AM

E

THU

N

IT

ED

S

TA

TE

S

AI

R

F O

R C

IL

E N

G

IN

EE

R

S Q

U

AD

R O

N

SE

YM

O

U R

J O

H N

SO

N

A

IR

F O

R C

E

BA

SE

, N

O R

TH

C

AR

O

LI

N

A

PR

O

JE

C

T

PH

AS

E

C O

N

TR

AC

T

N o.

TA

SK

O R

D

ER

N o.

AP

PR

V' D

D

AT

E D

ES

C

R

IP

TI

O

N R

EV

1 2 3 4 5 6 7 8 9 10 11

A

B

C

D

E

F

G

7 8 9 10 111 2 3 4 5 6

H

A

B

C

D

E

F

G

H p:\2017\17077_seymourjohnsonafb_bldg4901\17077_drawings\VKAG 13-9007 A202.dwg

12 SEPTEMBER 2018

AS-SHOWN

B.S.S.

9118A202

VKAG 13-9007

R

EP

AI

R

B

LD

G . 4

TO

H

O U

SE

AR

W /O

G

R

EN

O

VA

TI

O

N F

LO

O

R P

LA

N

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

W

8-

-D

-0

W

2H N

-1 7-

F-

/2

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

8/

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

3 2 1

VKAG

SCALE:

RENOVATION FLOOR PLAN

A202 A1

1/4" = 1'-0"

N0 4' 8' 16'

OSX/OSK

ROOM NUMBER

ROOM NAME

STC-45 RATED WALLS

(EXISTING OR PROPOSED)

SEE RENOVATION KEY NOTES

ROOM CONSTRUCTED TO CN551

4005 STANDARDS STC-45 RATED

WALLS (ROOM 18B ONLY)

E

EXISTING EXTERIOR WALL, SEE SHEET

A601 FOR ADDITIONAL INFORMATION

NEW INTERIOR WALL OR PARTITION, SEE

SHEET A602 FOR ADDITIONAL INFORMATION

EXISTING WALL OR PARTITION

NEW CMU WALL / CMU INFLL

NEW INTERIOR WALL OR PARTITION

STC-50 RATED WALLS

(EXISTING OR PROPOSED)

X

RENOVATION KEY NOTES:

PROVIDE 4" SPLIT FACE CMU VENEER TO CONVERT EXTERIOR SINGLE WYTHE MASONRY WALL TO MASONRY CAVITY WALL. PROVIDE 1 1/2" INSULATION IN NOMINAL 2" WALL CAVITY. SEE TYPICAL RENOVATION WALL

SECTION.

PROVIDE 4" SPLIT FACE CMU VENEER COLUMN COVERS FOR NEWLY CREATED CANOPIES. REFER TO

STRUCTURAL DRAWINGS.

PROVIDE STEEL COLUMNS AND BEAMS SUPPORTING EXISTING ROOF STRUCTURE WHERE LOAD BEARING MASONRY WALLS REMOVED. REFER TO STRUCTURAL DRAWINGS. PROVIDE GWB ON METAL STUD COLUMN

COVERS.

PROVIDE MASONRY WALLS AND PROVIDE 5/8" GWB FURRING ON 7/8" METAL CHANNELS AT 16" ON CENTER UNLESS NOTED OTHERWISE. PROVIDE GWB FURRING ON MASONRY WALLS TO MATCH EXISTING ADJACENT CONSTRUCTION. EXTEND FURRING 12" ABOVE CEILING ELEVATION. EXISTING WALL FURRING VARIES. WEST WING AREA FURRING IS 1/2" GWB ON 2x2 WOOD FURRING STRIPS 16" OC AND 1 1/2" RIGID INSULATION. OTHER

AREAS INCLUDE 5/8" GWB FURRING ON 7/8" OR 1 1/2" METAL CHANNELS 16" OC.

PROVIDE STEEL STUD PARTITIONS. 3-5/8" STUDS AND 6" STUDS AT TOILET CHASE WALLS AT 16" OC WITH 5/8"

GWB EACH FACE.

BLOCK INDICATED DOOR AND WINDOW OPENINGS WITH TOOTHED IN CMU AND GWB FURRING TO MATCH

EXISTING ADJACENT CONSTRUCTION.

PROVIDE ATFP COMPLIANT ALUMINUM STOREFRONT ENTRANCES. REFER TO DOOR SCHEDULE. FINISH SHALL BE DARK BRONZE ANODIZED ALUMINUM. GLAZING SHALL BE 1" INSULATING GLASS WITH 1/4" LAMINATED GLASS

PANES. GLASS TINT SHALL BE AS SELECTED BY CONTRACTING OFFICER

PROVIDE EXTERIOR HM DOORS IN HM FRAMES AND INTERIOR SOLID CORE WOOD DOORS IN HM DOOR FRAMES

UNLESS NOTED OTHERWISE. SEE DOOR SCHEDULE.

PROVIDE STC-45 RATED SECURITY DOOR ASSEMBLIES. SEE DOOR SCHEDULE.

NOT USED.

PROVIDE NEW FINISHES UNLESS OTHERWISE NOTED IN THE ENTIRE BUILDING. REFER TO ROOM FINISH

SCHEDULE, SEE SHEET A701.

PROVIDE HIGH PRESSURE LAMINATE CLAD BASE AND WALL CABINETS AND SOLID SURFACE COUNTERTOPS AT INDICATED LOCATIONS. REFRIGERATOR SHALL BE BY GOVERNMENT. CONTRACTOR SHALL PROVIDE WATER SUPPLY FOR THE REFRIGERATOR ICE MAKER. SLIDE IN ELECTRIC RANGE SHALL BE FURNISHED BY

GOVERNMENT AND INSTALLED BY CONTRACTOR. CONTRACTOR SHALL PROVIDE RANGE HOOD AND

EXTINGUISHING SYSTEM PER SOW.

PROVIDE MANUALLY OPERABLE PAIRED PANEL PARTITIONS AT INDICATED LOCATIONS. PROVIDE STEEL STUD

PARTITION WING WALLS TO FORM A POCKET FOR STORAGE OF PANELS IN OPEN POSITION.

PROVIDE INTERIOR ALUMINUM WINDOWS 4' HIGH x 3'-4" WIDE IN 13'-4" WINDOW STRIP. GLAZING SHALL BE 1" INSULATING GLASS (FOR ACOUSTIC PURPOSES) WITH 1/4" TEMPERED GLASS PANES.SILL HEIGHT SHALL BE 3'-2"

AFF. PROVIDE WINDOW BLINDS AT EACH WINDOW.

NOT USED.

PROVIDE 4' HIGH x 2' WIDE STAINLESS STEEL BANK TELLER WINDOW WITH PASS THRU DRAWER (STC 45 RATED).

GLAZING SHALL BE BULLET RESISTANT GLASS. WINDOW SILL HEIGHT SHALL BE 3'-2" AFF.

PROVIDE INTERIOR ALUMINUM WINDOW 4' HIGH x 4' WIDE AT INDICATED LOCATIONS. GLAZING SHALL BE 1" INSULATING GLASS (FOR ACOUSTIC PURPOSES) WITH 1/4" TEMPERED GLASS PANES. SILL HEIGHT SHALL BE 3'-2"

AFF. PROVIDE WINDOW BLINDS AT EACH WINDOW.

PROVIDE CONCRETE SLAB AT RESTRICTED AREA. SLOPE SLAB 1/8" PER FOOT AWAY FROM BUILDING. PROVIDE 8' HIGH, CLASS A CHAIN LINK FENCE (7'HIGH FABRIC, 45° OUTRIGGER WITH 3 STRANDS OF BARBED WIRE) WITH

DARK BRONZE COLOR SLATS. PROVIDE TOP PER UFC 4-010-01.

PROVIDE PAIR OF 4'x8' GATES MATCHING THE FENCE AT LOCATION TO BE APPROVED BY GOVERNMENT.

PROVIDE 3'x8' PERSONNEL EGRESS GATE MATCHING THE FENCE. PROVIDE PANIC BAR AND NO EXTERIOR TRIM.

PAINT 5' WIDE STRIPING DESIGNATING THE EGRESS PATH FROM DOOR 40.1 TO EGRESS GATE.

EXISTING STEEL LADDER AND ROOF HATCH TO ACCESS TO ATTIC AREA TO REMAIN.

PROVIDE ATFP COMPLIANT EXTERIOR FIXED ALUMINUM WINDOWS. WINDOWS SHALL BE 4' HIGH x 3'-4" WIDE WITH DARK BRONZE ANODIZED ALUMINUM FINISH. GLAZING SHALL BE 1" INSULATING GLASS WITH 1/4" LAMINATED GLASS PANES. GLASS TINT SHALL BE AS SELECTED BY CONTRACTING OFFICER. PROVIDE WINDOW BLINDS.

CONTRACTOR SHALL ASSURE THAT EXISTING AND NEW WALLS DESIGNATED AS STC-45 RATED SHALL BE EXTENDED TO THE BOTTOM OF EXISTING ROOF DECK. PROVIDE ACOUSTICAL SEALANT (ACOUSTICAL FOAM AT FLUTED DECKS) AT ALL EXISTING AND NEW STC RATED WALLS AT EACH SIDE OF FLOOR AND DECK JOINTS.

PROVIDE CAST ALUMINUM LETTER SIGN WITH 8" HIGH LETTERS "916 ARW GROUP OPERATIONS" AND TWO (2) ALUMINUM PANEL BUILDING NUMBER SIGNS TO BE MOUNTED AT LOCATIONS APPROVED BY GOVERNMENT.

RENOVATION PLAN LEGEND

8'-0" HIGH CHAIN LINK FENCING WITH 3

STRAND BARBED WIRE (PROVIDED 8' LONG

VINYL SLATS AT ALL CHAIN LINK MESH.

DOWNSPOUT LOCATION, SEE SHEET

A401 FOR ADDITIONAL INFORMATION

X

WINDOW NUMBER, SEE SHEET A701

DOOR NUMBER, SEE SHEET A702

SCALE:

DETAIL

MAIL SLOT

A202 A2

3/4" = 1'-0"

X X

VCT

19'-0" 16'-6"

'-8

'-8

15'-4"

'-4

5'-8" 26'-10"

24'-6"3'-4"

26'-4"

'-8

(T

O O

PP

W

AL

L)

'-8

31'-4"

'-8

'-4

(T O

O

PP

O

SI

TE

W

AL

L)

42A

25A

30.2

26.2 29.1

40.2

40.1

30.1

0'-4" RAISED FLR.

0'-4" RAISED FLR.

E

2B

2A

2A

6A

2A

4A

4B

4B

6A

4A 4A

OSX / OSK

BRIEF ROOM

MANTRAP

KITCHEN

HALL

34A

SHOWER

TOILET

INTEL

LOCKERS/

SHOWER

SR ART / ADMIN SUPPORT /

SORTS / TRAINING

S/O OFFICE

IN

TE

L

ST

OR

AG

E

A

EA CELL

FRAME ROOM

CORR.

40MECHANICAL

TOILET

CAT + SUPPORT

BATTLE STAFF

HALL

TOILET

25A

B5 A601

TYP.

1A

4A 4B

'-8

4'-10"

'-8

'-0

CORR.

31'-4"

6'-2" 41'-6"

4A

MATCH LINE - A

F3 A205

F1 A205

TYP.

9 TYP.

TYP.

E

E

E6 A205

MECHANICAL

MECHANICAL YARD,

REFER TO SHT. A206

MATCH LINE - A

M

AT

C H

L

IN

E

- B

'-0

1' -2

1'-0"

8'-2"

1'-0"

0' -1

0"

'-4

28'-8"

DS DS DS DS

DS

DS

DS

DS

DS

4B

E

4A

2'-4" 4'-0"

1'-2"

3'-0"D

6A

1 8

B5

A601 TYP.

5'-0"

'-3

3'

-0

4C 4A

6'-0"

1' -0

26'-4" 6'-0"

5' -9

6A

10'-0"

4A 6A 4A

5'-43 8"

6B

11'-0"

5' -8

'-4

'-4

'-8

3A

EQUAL 3'-0" EQUAL

5' -0

5'-0" 9'-10"

'-0

0'-4"

RAISED

FLR

8'-2"

'-8

6'

-0

36" H. ALUM.

RAILING BY

FLOOR MANUF.

36" H. ALUM.

RAILING BY

FLOOR MANUF.

4B 4A

12'-6"

5' -0

4A

0'-8"

5'-0" 4'-0"

5' -0

'-4

'-4

C

36" H. ALUM. RAILING BY

FLOOR MANUFACTURER

'-8

5'-10"

0'-8"

1' -0

DS

DS

NEW 54" LOUVER, REFER TO

MECHANICAL DRAWINGS

NEW 60" LOUVER, REFER TO

MECHANICAL DRAWINGS

UP

UP

5'-0"

4' -0

36" H. ALUM. RAILING BY

FLOOR MANUFACTURER

4' -1

0"

MAIL SLOT,

SEE DETAIL

THIS SHEET

0' -1

11 2" R

.O

X X

DS

STAINLESS

STEEL

MAILSLOT

CAT + SUPPORT

BATTLE STAFF

EA CELL

3 5/8" MTL STUDS

W/ 5/8" GYP.BD.

EACH FACE

MOUNTING

SCREWS

4' -0

AF

F

5/ 8"

R .O

.MAILSLOT

SLEEVE

1 5/8" MTL

FURRING

3 5/8" MTL STUDS

W/ 5/8" GYP.BD.

EACH FACE

25 GA.

SHEET

MTL OR

EQUIV.

HTR

F

UB T

I

TSR

OF

U

DATE

SHEET

DRAWN BY

OF

PROJECT NUMBER

DRAWING NUMBER

PR

O

JE

C

T

TI

TL

E

D R

AW

IN

G S

H

EE

T N

AM

E

THU

N

IT

ED

S

TA

TE

S

AI

R

F O

R C

IL

E N

G

IN

EE

R

S Q

U

AD

R O

N

SE

YM

O

U R

J O

H N

SO

N

A

IR

F O

R C

E

BA

SE

, N

O R

TH

C

AR

O

LI

N

A

PR

O

JE

C

T

PH

AS

E

C O

N

TR

AC

T

N o.

TA

SK

O R

D

ER

N o.

AP

PR

V' D

D

AT

E D

ES

C

R

IP

TI

O

N R

EV

1 2 3 4 5 6 7 8 9 10 11

A

B

C

D

E

F

G

7 8 9 10 111 2 3 4 5 6

H

A

B

C

D

E

F

G

H p:\2017\17077_seymourjohnsonafb_bldg4901\17077_drawings\VKAG 13-9007 A203.dwg

12 SEPTEMBER 2018

AS-SHOWN

B.S.S.

9119A203

VKAG 13-9007

R

EP

AI

R

B

LD

G . 4

TO

H

O U

SE

AR

W /O

G

R

EN

O

VA

TI

O

N F

LO

O

R P

LA

N

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

W

8-

-D

-0

W

2H N

-1 7-

F-

/2

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

8/

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

3 2 1

VKAG

SCALE:

RENOVATION FLOOR PLAN

A203 A1

1/4" = 1'-0"

N0 4' 8' 16'

OSX/OSK

RENOVATION PLAN LEGEND

ROOM NUMBER

ROOM NAME

STC-45 RATED WALLS

(EXISTING OR PROPOSED)

SEE RENOVATION KEY NOTES

ROOM CONSTRUCTED TO CN551 4005

STANDARDS STC-45 RATED WALLS

(ROOM 18B ONLY)

E

EXISTING EXTERIOR WALL, SEE SHEET

A601 FOR ADDITIONAL INFORMATION

NEW INTERIOR WALL OR PARTITION, SEE

SHEET A602 FOR ADDITIONAL INFORMATION

STC-50 RATED WALLS

(EXISTING OR PROPOSED)

X

RENOVATION KEY NOTES:

PROVIDE 4" SPLIT FACE CMU VENEER TO CONVERT EXTERIOR SINGLE WYTHE MASONRY WALL TO MASONRY CAVITY WALL. PROVIDE 1 1/2" INSULATION IN NOMINAL 2" WALL CAVITY. SEE TYPICAL RENOVATION WALL

SECTION.

PROVIDE 4" SPLIT FACE CMU VENEER COLUMN COVERS FOR NEWLY CREATED CANOPIES. REFER TO

STRUCTURAL DRAWINGS.

PROVIDE STEEL COLUMNS AND BEAMS SUPPORTING EXISTING ROOF STRUCTURE WHERE LOAD BEARING MASONRY WALLS REMOVED. REFER TO STRUCTURAL DRAWINGS. PROVIDE GWB ON METAL STUD COLUMN

COVERS.

PROVIDE MASONRY WALLS AND PROVIDE 5/8" GWB FURRING ON 7/8" METAL CHANNELS AT 16" ON CENTER UNLESS NOTED OTHERWISE. PROVIDE GWB FURRING ON MASONRY WALLS TO MATCH EXISTING ADJACENT CONSTRUCTION. EXTEND FURRING 12" ABOVE CEILING ELEVATION. EXISTING WALL FURRING VARIES. WEST WING AREA FURRING IS 1/2" GWB ON 2x2 WOOD FURRING STRIPS 16" OC AND 1 1/2" RIGID INSULATION. OTHER

AREAS INCLUDE 5/8" GWB FURRING ON 7/8" OR 1 1/2" METAL CHANNELS 16" OC.

PROVIDE STEEL STUD PARTITIONS. 3-5/8" STUDS AND 6" STUDS AT TOILET CHASE WALLS AT 16" OC WITH 5/8"

GWB EACH FACE.

BLOCK INDICATED DOOR AND WINDOW OPENINGS WITH TOOTHED IN CMU AND GWB FURRING TO MATCH

EXISTING ADJACENT CONSTRUCTION.

PROVIDE ATFP COMPLIANT ALUMINUM STOREFRONT ENTRANCES. REFER TO DOOR SCHEDULE. FINISH SHALL BE DARK BRONZE ANODIZED ALUMINUM. GLAZING SHALL BE 1" INSULATING GLASS WITH 1/4" LAMINATED GLASS

PANES. GLASS TINT SHALL BE AS SELECTED BY CONTRACTING OFFICER

PROVIDE EXTERIOR HM DOORS IN HM FRAMES AND INTERIOR SOLID CORE WOOD DOORS IN HM DOOR FRAMES

UNLESS NOTED OTHERWISE. SEE DOOR SCHEDULE.

PROVIDE STC-45 RATED SECURITY DOOR ASSEMBLIES. SEE DOOR SCHEDULE.

NOT USED.

PROVIDE NEW FINISHES UNLESS OTHERWISE NOTED IN THE ENTIRE BUILDING. REFER TO ROOM FINISH

SCHEDULE. SEE SHEET A701.

PROVIDE HIGH PRESSURE LAMINATE CLAD BASE AND WALL CABINETS AND SOLID SURFACE COUNTERTOPS AT INDICATED LOCATIONS. REFRIGERATOR SHALL BE BY GOVERNMENT. CONTRACTOR SHALL PROVIDE WATER SUPPLY FOR THE REFRIGERATOR ICE MAKER. SLIDE IN ELECTRIC RANGE SHALL BE FURNISHED BY

GOVERNMENT AND INSTALLED BY CONTRACTOR. CONTRACTOR SHALL PROVIDE RANGE HOOD AND

EXTINGUISHING SYSTEM PER SOW.

PROVIDE MANUALLY OPERABLE PAIRED PANEL PARTITIONS AT INDICATED LOCATIONS. PROVIDE STEEL STUD

PARTITION WING WALLS TO FORM A POCKET FOR STORAGE OF PANELS IN OPEN POSITION.

PROVIDE INTERIOR ALUMINUM WINDOWS 4' HIGH x 3'-4" WIDE IN 13'-4" WINDOW STRIP. GLAZING SHALL BE 1" INSULATING GLASS (FOR ACOUSTIC PURPOSES) WITH 1/4" TEMPERED GLASS PANES.SILL HEIGHT SHALL BE 3'-2"

AFF. PROVIDE WINDOW BLINDS AT EACH WINDOW.

NOT USED.

PROVIDE 4' HIGH x 2' WIDE STAINLESS STEEL BANK TELLER WINDOW WITH PASS THRU DRAWER (STC 45 RATED).

GLAZING SHALL BE BULLET RESISTANT GLASS. WINDOW SILL HEIGHT SHALL BE 3'-2" AFF.

PROVIDE INTERIOR ALUMINUM WINDOW 4' HIGH x 4' WIDE AT INDICATED LOCATIONS. GLAZING SHALL BE 1" INSULATING GLASS (FOR ACOUSTIC PURPOSES) WITH 1/4" TEMPERED GLASS PANES. SILL HEIGHT SHALL BE 3'-2"

AFF. PROVIDE WINDOW BLINDS AT EACH WINDOW.

PROVIDE CONCRETE SLAB AT RESTRICTED AREA. SLOPE SLAB 1/8" PER FOOT AWAY FROM BUILDING. PROVIDE 8' HIGH, CLASS A CHAIN LINK FENCE (7'HIGH FABRIC, 45° OUTRIGGER WITH 3 STRANDS OF BARBED WIRE) WITH

DARK BRONZE COLOR SLATS. PROVIDE TOP PER UFC 4-010-01.

PROVIDE PAIR OF 4'x8' GATES MATCHING THE FENCE AT LOCATION TO BE APPROVED BY GOVERNMENT.

PROVIDE 3'x8' PERSONNEL EGRESS GATE MATCHING THE FENCE. PROVIDE PANIC BAR AND NO EXTERIOR TRIM.

PAINT 5' WIDE STRIPING DESIGNATING THE EGRESS PATH FROM DOOR 40.1 TO EGRESS GATE.

EXISTING STEEL LADDER AND ROOF HATCH TO ACCESS TO ATTIC AREA TO REMAIN.

PROVIDE ATFP COMPLIANT EXTERIOR FIXED ALUMINUM WINDOWS. WINDOWS SHALL BE 4' HIGH x 3'-4" WIDE WITH DARK BRONZE ANODIZED ALUMINUM FINISH. GLAZING SHALL BE 1" INSULATING GLASS WITH 1/4" LAMINATED GLASS PANES. GLASS TINT SHALL BE AS SELECTED BY CONTRACTING OFFICER. PROVIDE WINDOW BLINDS.

CONTRACTOR SHALL ASSURE THAT EXISTING AND NEW WALLS DESIGNATED AS STC-45 RATED SHALL BE EXTENDED TO THE BOTTOM OF EXISTING ROOF DECK. PROVIDE ACOUSTICAL SEALANT (ACOUSTICAL FOAM AT FLUTED DECKS) AT ALL EXISTING AND NEW STC RATED WALLS AT EACH SIDE OF FLOOR AND DECK JOINTS.

PROVIDE CAST ALUMINUM LETTER SIGN WITH 8" HIGH LETTERS "916 ARW GROUP OPERATIONS" AND TWO (2) ALUMINUM PANEL BUILDING NUMBER SIGNS TO BE MOUNTED AT LOCATIONS APPROVED BY GOVERNMENT.

EXISTING WALL OR PARTITION

NEW CMU WALL / CMU INFLL

NEW INTERIOR WALL OR PARTITION

8'-0" HIGH CHAIN LINK FENCING WITH

3 STRAND BARBED WIRE (PROVIDED

8' LONG VINYL SLATS AT ALL CHAIN

LINK MESH.

DOWNSPOUT LOCATION, SEE SHEET

A401 FOR ADDITIONAL INFORMATION

WINDOW NUMBER, SEE SHEET A701

DOOR NUMBER, SEE SHEET A702100

X

15'-0"

'-0

12'-0"

8' -0

25'-4"

32'-2"

37'-8"

4' -8

'-0

22'-61 2"22'-61

2"

'-8

TO

O

PP

W

AL

L

26'-4" 30'-4"

'-0

18A18

18B

192022

25A

26.2 29.1

26.1

E

E

2A

1A

1A

8A

3B

3B

5A

1A 1A 1A

1C

1A

MECHANICAL

WOMEN

CUST.

16MEN

CREW COMM

SUPER

18A

CORRIDOR

01A

COMBAT CREW

COMM - OPEN OFFICE

OSX / OSK

BRIEF ROOM

MANTRAP

CORRIDOR

LOCKERS

01B

OIC + NCOIC +

SUPER

KITCHEN

HALL

34A

SHOWER

TOILET

CMF STORAGE

SAFE / SIPR /

TRAINING

18B

ISS

BAG ISSUE

INTEL

BRIEF ROOM

INTEL

LOCKERS/

SHOWER

TOILET

25A

1B

6A

4A

4A

B1 A601

TYP. INFILL EXT.

WALL DETAIL

1C

3A

6'-2" 41'-6"

29.2

MATCH LINE - A

MATCH LINE - A

M

AT

C H

L

IN

E

- B

M

AT

C H

L

IN

E

- B24

TYP.

TYP.

TYP.

A1 A205

4B4B

5B

E

E

19'-0"

TO OPPOSITE WALL

'-4

'-1

0"

'-6

'-0

35'-0" 32'-8"

8 8

20'-0" 4'-8"

2' -0

20'-0"

'-8

'-0

8B

1A

6' -0

6'

-0

8 9

DS

DS

DS

DS

DS DS DS

DS

B5 A601

TYP.

E

4 4 4

6A

5A 5A

'-8

11'-0" 11'-0"

4C

4C

4A

4A

1B 4A

5B

5A

8 8

5A

6' -0

'-1

0"

'-4

'-0

6'

-0

'-4

5A

8 36A

COP

36A

6A

F 3'-2"

'-1

1 2"

'-6 1 2"

6A 6B8

3 TEIR, 12"x12" METAL LOCKERS - WALL

MOUNTED @ 60" TO TOP OF UNIT,

CENTERED BETWEEN PILASTERS

DS

NEW 54" LOUVER, REFER TO

MECHANICAL DRAWINGS

X X X

DS

HTR

F

UB T

I

TSR

OF

U

DATE

SHEET

DRAWN BY

OF

PROJECT NUMBER

DRAWING NUMBER

PR

O

JE

C

T

TI

TL

E

D R

AW

IN

G S

H

EE

T N

AM

E

THU

N

IT

ED

S

TA

TE

S

AI

R

F O

R C

IL

E N

G

IN

EE

R

S Q

U

AD

R O

N

SE

YM

O

U R

J O

H N

SO

N

A

IR

F O

R C

E

BA

SE

, N

O R

TH

C

AR

O

LI

N

A

PR

O

JE

C

T

PH

AS

E

C O

N

TR

AC

T

N o.

TA

SK

O R

D

ER

N o.

AP

PR

V' D

D

AT

E D

ES

C

R

IP

TI

O

N R

EV

1 2 3 4 5 6 7 8 9 10 11

A

B

C

D

E

F

G

7 8 9 10 111 2 3 4 5 6

H

A

B

C

D

E

F

G

H p:\2017\17077_seymourjohnsonafb_bldg4901\17077_drawings\VKAG 13-9007 A204.dwg

12 SEPTEMBER 2018

AS-SHOWN

B.S.S.

9120A204

VKAG 13-9007

R

EP

AI

R

B

LD

G . 4

TO

H

O U

SE

AR

W /O

G

R

EN

O

VA

TI

O

N F

LO

O

R P

LA

N

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

W

8-

-D

-0

W

2H N

-1 7-

F-

/2

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

8/

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

3 2 1

VKAG

SCALE:

RENOVATION FLOOR PLAN

A204 A1

1/4" = 1'-0"

N0 4' 8' 16'

OSX/OSK

RENOVATION PLAN LEGEND

ROOM NUMBER

ROOM NAME

STC-45 RATED WALLS

(EXISTING OR PROPOSED)

SEE RENOVATION KEY NOTES

ROOM CONSTRUCTED TO CN551 4005

STANDARDS STC-45 RATED WALLS

(ROOM 18B ONLY)

E

EXISTING EXTERIOR WALL, SEE SHEET A601

FOR ADDITIONAL INFORMATION

NEW INTERIOR WALL OR PARTITION, SEE

SHEET A602 FOR ADDITIONAL INFORMATION

EXISTING WALL OR PARTITION

NEW CMU WALL / CMU INFLL

NEW INTERIOR WALL OR PARTITIONSTC-50 RATED WALLS

(EXISTING OR PROPOSED)

X

RENOVATION KEY NOTES:

PROVIDE 4" SPLIT FACE CMU VENEER TO CONVERT EXTERIOR SINGLE WYTHE MASONRY WALL TO MASONRY CAVITY WALL. PROVIDE 1 1/2" INSULATION IN NOMINAL 2" WALL CAVITY. SEE TYPICAL RENOVATION WALL

SECTION.

PROVIDE 4" SPLIT FACE CMU VENEER COLUMN COVERS FOR NEWLY CREATED CANOPIES. REFER TO

STRUCTURAL DRAWINGS.

PROVIDE STEEL COLUMNS AND BEAMS SUPPORTING EXISTING ROOF STRUCTURE WHERE LOAD BEARING MASONRY WALLS REMOVED. REFER TO STRUCTURAL DRAWINGS. PROVIDE GWB ON METAL STUD COLUMN

COVERS.

PROVIDE MASONRY WALLS AND PROVIDE 5/8" GWB FURRING ON 7/8" METAL CHANNELS AT 16" ON CENTER UNLESS NOTED OTHERWISE. PROVIDE GWB FURRING ON MASONRY WALLS TO MATCH EXISTING ADJACENT CONSTRUCTION. EXTEND FURRING 12" ABOVE CEILING ELEVATION. EXISTING WALL FURRING VARIES. WEST WING AREA FURRING IS 1/2" GWB ON 2x2 WOOD FURRING STRIPS 16" OC AND 1 1/2" RIGID INSULATION. OTHER

AREAS INCLUDE 5/8" GWB FURRING ON 7/8" OR 1 1/2" METAL CHANNELS 16" OC.

PROVIDE STEEL STUD PARTITIONS. 3-5/8" STUDS AND 6" STUDS AT TOILET CHASE WALLS AT 16" OC WITH 5/8"

GWB EACH FACE.

BLOCK INDICATED DOOR AND WINDOW OPENINGS WITH TOOTHED IN CMU AND GWB FURRING TO MATCH

EXISTING ADJACENT CONSTRUCTION.

PROVIDE ATFP COMPLIANT ALUMINUM STOREFRONT ENTRANCES. REFER TO DOOR SCHEDULE. FINISH SHALL BE DARK BRONZE ANODIZED ALUMINUM. GLAZING SHALL BE 1" INSULATING GLASS WITH 1/4" LAMINATED GLASS

PANES. GLASS TINT SHALL BE AS SELECTED BY CONTRACTING OFFICER

PROVIDE EXTERIOR HM DOORS IN HM FRAMES AND INTERIOR SOLID CORE WOOD DOORS IN HM DOOR FRAMES

UNLESS NOTED OTHERWISE. SEE DOOR SCHEDULE.

PROVIDE STC-45 RATED SECURITY DOOR ASSEMBLIES. SEE DOOR SCHEDULE.

NOT USED.

PROVIDE NEW FINISHES UNLESS OTHERWISE NOTED IN THE ENTIRE BUILDING. REFER TO ROOM FINISH

SCHEDULE, SEE SHEET A701.

PROVIDE HIGH PRESSURE LAMINATE CLAD BASE AND WALL CABINETS AND SOLID SURFACE COUNTERTOPS AT INDICATED LOCATIONS. REFRIGERATOR SHALL BE BY GOVERNMENT. CONTRACTOR SHALL PROVIDE WATER SUPPLY FOR THE REFRIGERATOR ICE MAKER. SLIDE IN ELECTRIC RANGE SHALL BE FURNISHED BY

GOVERNMENT AND INSTALLED BY CONTRACTOR. CONTRACTOR SHALL PROVIDE RANGE HOOD AND

EXTINGUISHING SYSTEM PER SOW.

PROVIDE MANUALLY OPERABLE PAIRED PANEL PARTITIONS AT INDICATED LOCATIONS. PROVIDE STEEL STUD

PARTITION WING WALLS TO FORM A POCKET FOR STORAGE OF PANELS IN OPEN POSITION.

PROVIDE INTERIOR ALUMINUM WINDOWS 4' HIGH x 3'-4" WIDE IN 13'-4" WINDOW STRIP. GLAZING SHALL BE 1" INSULATING GLASS (FOR ACOUSTIC PURPOSES) WITH 1/4" TEMPERED GLASS PANES.SILL HEIGHT SHALL BE 3'-2"

AFF. PROVIDE WINDOW BLINDS AT EACH WINDOW.

NOT USED.

PROVIDE 4' HIGH x 2' WIDE STAINLESS STEEL BANK TELLER WINDOW WITH PASS THRU DRAWER (STC 45 RATED).

GLAZING SHALL BE BULLET RESISTANT GLASS. WINDOW SILL HEIGHT SHALL BE 3'-2" AFF.

PROVIDE INTERIOR ALUMINUM WINDOW 4' HIGH x 4' WIDE AT INDICATED LOCATIONS. GLAZING SHALL BE 1" INSULATING GLASS (FOR ACOUSTIC PURPOSES) WITH 1/4" TEMPERED GLASS PANES. SILL HEIGHT SHALL BE 3'-2"

AFF. PROVIDE WINDOW BLINDS AT EACH WINDOW.

PROVIDE CONCRETE SLAB AT RESTRICTED AREA. SLOPE SLAB 1/8" PER FOOT AWAY FROM BUILDING. PROVIDE 8' HIGH, CLASS A CHAIN LINK FENCE (7'HIGH FABRIC, 45° OUTRIGGER WITH 3 STRANDS OF BARBED WIRE) WITH

DARK BRONZE COLOR SLATS. PROVIDE TOP PER UFC 4-010-01.

PROVIDE PAIR OF 4'x8' GATES MATCHING THE FENCE AT LOCATION TO BE APPROVED BY GOVERNMENT.

PROVIDE 3'x8' PERSONNEL EGRESS GATE MATCHING THE FENCE. PROVIDE PANIC BAR AND NO EXTERIOR TRIM.

PAINT 5' WIDE STRIPING DESIGNATING THE EGRESS PATH FROM DOOR 40.1 TO EGRESS GATE.

EXISTING STEEL LADDER AND ROOF HATCH TO ACCESS TO ATTIC AREA TO REMAIN.

PROVIDE ATFP COMPLIANT EXTERIOR FIXED ALUMINUM WINDOWS. WINDOWS SHALL BE 4' HIGH x 3'-4" WIDE WITH DARK BRONZE ANODIZED ALUMINUM FINISH. GLAZING SHALL BE 1" INSULATING GLASS WITH 1/4" LAMINATED GLASS PANES. GLASS TINT SHALL BE AS SELECTED BY CONTRACTING OFFICER. PROVIDE WINDOW BLINDS.

CONTRACTOR SHALL ASSURE THAT EXISTING AND NEW WALLS DESIGNATED AS STC-45 RATED SHALL BE EXTENDED TO THE BOTTOM OF EXISTING ROOF DECK. PROVIDE ACOUSTICAL SEALANT (ACOUSTICAL FOAM AT FLUTED DECKS) AT ALL EXISTING AND NEW STC RATED WALLS AT EACH SIDE OF FLOOR AND DECK JOINTS.

PROVIDE CAST ALUMINUM LETTER SIGN WITH 8" HIGH LETTERS "916 ARW GROUP OPERATIONS" AND TWO (2) ALUMINUM PANEL BUILDING NUMBER SIGNS TO BE MOUNTED AT LOCATIONS APPROVED BY GOVERNMENT.

8'-0" HIGH CHAIN LINK FENCING WITH

3 STRAND BARBED WIRE (PROVIDED

8' LONG VINYL SLATS AT ALL CHAIN

LINK MESH.

DOWNSPOUT LOCATION, SEE SHEET

A401 FOR ADDITIONAL INFORMATION

SCALE:

GUARDRAIL SECTION (TYP.)

A204 G4

3/4" = 1'-0"

SCALE:

SECTION AT RAMP

A204 G1

1/4" = 1'-0"

SCALE:

TREAD DETAIL (TYP.)

A204 G7

3/4" = 1'-0"

08A

27'-2"

'-0

20'-6" 12'-10"

9' -1

0" 7'

-8

14'-5"

'-8

5'

-0

23'-6"

'-6

6'-8" 11'-0" 11'-4" 11'-0" 7'-0" 7'-0"

'-6

9'-8"

'-4

09A

08B

07060504

03B03A

01.2

01.1

E

E

E

OG EXEC2

08C

OG SEC

OG CC

OG EXEC

08D

CORRIDOR

BREAK

ROOM

OSS CC

03A

SEC

OSS DO

03B

OSS

1ST SGT

OG CHEIF

OG

UDM/CEA

RA

07A

UTM

07B

OSS

ADMIN

CONFERENCE

ROOM

OSX/

OSK PLANS

LOBBY

MECHANICAL

IT EQUIP

BATH

09A

3B 6A

1A 1A

4A 4A

4A 4A

4A

4A

4A

8A

4A 4A 4A 4A

1A 1A

4A

6A

1A 1A

4A

10'-0"

OG CD

08B

10'-0"

8A

CLOSET

08A

4A

29'-4"

M

AT

C H

L

IN

E

- B

M

AT

C H

L

IN

E

- B

TYP.

7 22 TYP.

4A

4A

22 TYP. E

A9 A205

A6 A205

5B

A A A A A A A A A A

8 8 8 8

4 4

B1

A601 TYP.

WALL

INFILL

B5

A601 TYP.

6' -0

B

B

DS

DS DS

DS

DS DS DS

DS

DS

DSDSDSDSDS

6' -2

'-6

E 16'-5" 11'-6"

1'-8"

6' -2

'-0

2' -2

6B

8 6A

4A

4C8'-7"

1A 1A

4B

AAA

B1 A601

TYP.

WALL

INFILL

B5

A601 TYP.

UP

G1 A204

3' -0

8'

-8

'-0

5'

-0

5'-0"

RAMP

UP

8'-0"

5' -0

98.23 EL.

2' -0

98.13 EL.

1' -8

99.98 EL.

98.84 EL.

98.74 EL.

98.74 EL.

98.64 EL.

SEE CIVIL FOR

CONTINUATION

FOR CONCRETE

WALK

X X X

DS

EQ

U

AL

3"

3' -6

"1 1/2" O.D. MTL.

PIPE RAIL & POST

0'-3" MIN. EQ

U

AL

ESCUTCHEON

2' -1

0"

1-1/2" O.D. MTL.

PIPE HANDRAIL

4"

NEW COMPACTED FILL

NEW CONC.

SIDEWALK

NEW RAILING

SEE DETAIL

G4/A204

1:12 SLOPE

NEW CONC.

RAMPNEW CONC. STEPS,

(3) R@ 7", (2) T@11"

SEE DETAIL G7/A204

NEW CONC.

SIDEWALK

0'-1" NOSING

TREAD 0'-11" MIN.

SEE PLAN

NON-SLIP STAIR

NOSING, TYPICAL

REINFORCING STEEL

REBAR

7" M

AX

0' -6

(4) BENT #5

(3) RISERS @ 7" = 1'-9"

(2) TREADS @ 11" = 1'-10"

COMPACTED

FILL

HTR

F

UB T

I

TSR

OF

U

DATE

SHEET

DRAWN BY

OF

PROJECT NUMBER

DRAWING NUMBER

PR

O

JE

C

T

TI

TL

E

D R

AW

IN

G S

H

EE

T N

AM

E

THU

N

IT

ED

S

TA

TE

S

AI

R

F O

R C

IL

E N

G

IN

EE

R

S Q

U

AD

R O

N

SE

YM

O

U R

J O

H N

SO

N

A

IR

F O

R C

E

BA

SE

, N

O R

TH

C

AR

O

LI

N

A

PR

O

JE

C

T

PH

AS

E

C O

N

TR

AC

T

N o.

TA

SK

O R

D

ER

N o.

AP

PR

V' D

D

AT

E D

ES

C

R

IP

TI

O

N R

EV

1 2 3 4 5 6 7 8 9 10 11

A

B

C

D

E

F

G

7 8 9 10 111 2 3 4 5 6

H

A

B

C

D

E

F

G

H p:\2017\17077_seymourjohnsonafb_bldg4901\17077_drawings\VKAG 13-9007 A702.dwg

12 SEPTEMBER 2018

AS-SHOWN

B.S.S.

9130A702

VKAG 13-9007

R

EP

AI

R

B

LD

G . 4

TO

H

O U

SE

AR

W /O

G

SC

H

ED

U

LE

S

AN

D

N O

TE

S

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

W

8-

-D

-0

W

2H N

-1 7-

F-

/2

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

8/

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

/2

F

IN

AL

S

U

BM

IT

TA

L

- R

EV

IS

IO

N

3 2 1

VKAG

DOORDOOR NO.

DOOR SCHEDULE

REMARKS

01.1

DOOR SIZE

PR 3'-0" x 7'-0" ALFG1

MATERIALTYPE FINISH

AN

FRAME

MATERIALTYPE FINISH

A2 AL AN

01.2 PR 3'-0" x 7'-0" ALFG1 AN A2 AL AN

3'-0" x 7'-0" ALFG1 AN A3 AL AN

3'-0" x 7'-0"

04 3'-0" x 7'-0"

13 PR 3'-0" x 7'-0" HM P M4 HM P

3'-0" x 7'-0" WD S M1 HM P

3'-0" x 7'-0" WD S M1 HM P 3'-0" x 7'-0" WD S M1 HM P 3'-0" x 7'-0" WD S M1 HM P

HM P

3'-0" x 7'-0" HM P3'-0" x 7'-0"

HM P3'-0" x 7'-0" HM P3'-0" x 7'-0"

F3 M3 HM P3'-0" x 7'-0" HM P

HM P3'-0" x 7'-0"

26.1 26.2

F1 M1 HM P

3'-0" x 7'-0"

WD S CARD READER - AEC

F2 HM P M2 HM P

3'-0" x 7'-0"

30.1 30.2

F2 M2 HM P3'-0" x 7'-0" HM P HM P3'-0" x 7'-0"

DD1 WD S M1 HM P

WD S M1 HM P

WD S M1 HM P

WD S M1 HM P

3'-0" x 7'-0" 3'-0" x 7'-0"

3'-0" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0"

HM P

HM P

HM P

F2 M2

HM P

HM P HM P

HM P

40.1

3'-0" x 7'-0" 3'-0" x 7'-0"

40.2 3'-0" x 7'-0"

PR 3'-0" x 7'-0"PR 3'-0" x 7'-0" F1 HM P M4 HM P

HOLLOW METAL

SOLID CORE WOOD

DOOR SCHEDULE LEGEND

WD

HM

S STAINED

AL ALUMINUM

P PAINTED

AN ANODIZED

14 3'-0" x 7'-0" WD S M1 HM P

29.1 3'-0" x 7'-0" HM P

3'-0"3'-0"3'-0"

7' -0

7' -0

7' -0

TYPE FG1

1" INSULATING GLASS WITH

ALUM STOREFRONT ENTRANCE

1/4" LAMINATED GLASS PANES

TYPE F2

FLUSH DOOR

TYPE HG1

HALF GLASS

TEMPERED GLAZING

18A 18B

3'-0" x 7'-0" WD S M1 HM P 3'-0" x 7'-0"

F1 WD S M1

F3 WD S M3

HG WD S M1

F1 WD S M1

F1 WD S M1

F1 WD S M1

WD S M1

WD S M1

WD S M1

WD S M1

F1 WD S M1

DUTCH DOOR WITH SHELF

EXISTING, SALVAGEDX

HG HALF GLASS

F FLUSH

DD DUTCH DOOR

F1 F1 F1 F1 F1 F1 F1

HALF GLASS DOOR

F1

F1 F1

F1 F1

F1

STC-45 RATED

3' -0

1/4" TEMP

GLASS

F1 WD S M1

EMERGENCY EGRESS ONLY WITH ALARM *

EMERGENCY EGRESS ONLY WITH ALARM *

EMERGENCY EGRESS ONLY WITH ALARM *

03A 03B

08A 08B

09A

WD S HM P

3'-0" x 7'-0" WD S HM P

3'-0" x 7'-0" WD S HM PM1F1

3'-0" x 7'-0" WD S HM P 3'-0" x 7'-0" WD S HM P

3'-0" x 7'-0" WD S HM PM1F1 3'-0" x 7'-0" WD S HM PM1F1

3'-0" x 7'-0" WD S HM PM1F1 3'-0" x 7'-0" WD S HM PM1F1

3'-0" x 7'-0"

3'-0" x 7'-0" WD S HM PM1F1

2'-0"

11 3'-0" x 7'-0"

25 A 3'-0" x 7'-0" F1 WD S M1 HM P

S M1 HM P

29.2 3'-0" x 7'-0" F2 WD S M2 HM P

19 3'-0" x 7'-0" F1 WD S M1 HM P

CARD READER - AEC (ALARMED)

AEC = AUTOMATIC

ENTRY CONTROL

* = NO EXTERIOR

TRIM

HM PM2HM PF2

ALFG2 AN A1 AL AN NON-INSULATED: FULL WALL GLASS

HM PM1WD P PROVIDE CIPHER LOCKF1

PROVIDE ATFP COMPLIANCE / RATING

PROVIDE ATFP COMPLIANCE / RATING

PROVIDE ATFP COMPLIANCE / RATING

F1 WD

06 3'-0" x 7'-0" WD S HM P

DETAIL

JAMBHEAD SILL

STC

WD S HM PM1F1

6'-4"

6'-0"

6'-0"

3'-4"

3'-0"

10'-8"

7' -0

0'

-2

7' -0

0'

-2

7' -0

0'

-2

TYPE A2

ALUM STOREFRONT ENTRANCE

TYPE A1

ALUM STOREFRONT ENTRANCE

1/4" LAMINATED GLASS PANES

TYPE M1

H.M. FRAME

TYPE M4

H.M. FRAME

NO STC RATINGNO STC RATING

1" INSULATING GLASS WITH

1/4" LAMINATED GLASS PANES

3'-0"

7' -0

TYPE F1

FLUSH DOOR

NO STC RATING

3'-0"

7' -0

TYPE F3

FLUSH DOOR

STC-50 RATED

3'-0"

7' -0

" 4' -0

3'

-0

TYPE DD1

DUTCH DOOR

6" DEEP STAINLESS

STEEL SHELF

3'-0"

SEE WINDOW

SCHEDULE

7' -0

0'

-2

3' -2

0'

-2

3'-4"

3'-0"

7' -0

0'

-2

TYPE M2

H.M. FRAME

STC-45 RATING

3'-4"

3'-0"

7' -0

0'

-2

TYPE M3

H.M. FRAME

STC-50 RATING

3'-0"

7' -0

TYPE FG2

ALUM STOREFRONT ENTRANCE

1/4" LAMINATED GLASS PANES

3'-0"

5'-6"

7' -0

0'

-2

TYPE A3

ALUM STOREFRONT ENTRANCE

1" INSULATING GLASS WITH

1/4" LAMINATED GLASS PANES

HDW. GP.

M1F1 M1F1 M1F1 M1F1 M1F1

CARD READER - AEC (ALARMED)

-- -- -- 06

FG FULL GLASS

PROVIDE CIPHER LOCK

EMERGENCY EGRESS ONLY WITH ALARM *

42A PR 3'-0" x 7'-0"PR 3'-0" x 7'-0" F1 WD S M4 HM P -- -- -- 15

38A 3'-0" x 7'-0"

SCALE:

DOOR TYPES

1/4" = 1'-0" SCALE:

DOOR FRAME TYPES

1/4" = 1'-0"

WINDOW SCHEDULE

A

MARK OPENING SIZE

WINDOW FRAME

W H

TYPE FINISHMAT'L

DETAIL

(SHEET A703)

H J S

GLAZING

TYPE

REMARKSHEAD

HGT.

EXTERIOR, COMMAND WING3'-4" 4'-0" ALUM BG6 E6 C6

FIRE

RATING

-DK. BRONZEFIXED

AFF

GLAZING TYPES

A - TEMPERED

B - EXTERIOR INSUL LAM.

C - BULLET RESISTANT

ANODIZED

MATCH

EXISTING

B EXTERIOR, COMMAND WING WEST6'-8" 4'-0" ALUM BG6 E6 C6 -DK. BRONZEFIXED ANODIZED

MATCH

EXISTING

C INTERIOR BETWEEN ROOMS 30 & 3213'-4" 4'-0" ALUM AG3 E3 C3 -CLEARFIXED ANODIZED 7'-2"

D INTERIOR BETWEEN ROOMS 23 & 244'-0" 4'-0" ALUM AG3 E3 C3 -CLEARFIXED ANODIZED 7'-2"

E INTERIOR BETWEEN ROOMS 8 & 1216'-2" 7'-2" ALUM AG3 E3 C9 -CLEARFIXED ANODIZED 7'-2"

F B.R. TELLER TRANSACTION WINDOW W/ PASS-THRU DRAW.2'-0" 5'-0" ALUM CG1 G1 E1/ -CLEARFIXED ANODIZED 7'-2"C1

3' -2

F.

V.

4'

-0

A

3'-4"

2' -6

1' -6

3' -2

F.

V.

4'

-0

3'-4"

2' -6

1' -6

3'-4"

B

3' -2

4'

-0

13'-4"

C

3' -2

4'

-0

D

4'-0"

2' -1

0" 4'

-4

F

2'-0"

4' -4

0' -8

SLIDING

SECURITY

DRAWER

7' -0

0'

-2

3' -2

0'

-2

6'-4"

0'-4"

3'-2" 6'-4"

E

ALUM. BREAKMETAL

COVER AT EXISTING

COLUMN

16'-2"

FIN. FLOOR

SCALE:

WINDOW ELEVATIONS

1/4" = 1'-0"

BY-PASS SLIDING DOOR

HM PWD S M1F1 -- -- -- 05