Attachment 3 - Electrical Telecomm As Designed

View the file

Other files for this federal contract opportunity

Other files attached to Audio Visual and Teleconferencing Equipment, newest first.
File Type Posted
Amendment_003_Extend_Proposal_Due_Date.pdf PDF
Attach_01_-_Questions.pdf PDF
SF30_Amendment_002.pdf PDF
Attachment_5_-_Highlights.pdf PDF
Attachment_4_-_Addendum_to_52.212-1_Change.pdf PDF
Attachment_1_-_Site_Visit_Questions_V5-Final_June_2nd_Release_-_WG_Conf_Room.pdf PDF
Attachment_2_-_Electrical.pdf PDF
SF30_Amendment.pdf PDF
FA4620-14-R-A006_Wing_AV_and_Teleconferencing.pdf PDF
Attachment_A_-_Courtroom_Drawings.pdf PDF
Attachment_B_-_JA_Conference_Room.pdf PDF
Attachment_C_-_Wg_Conference_Room_Drawings.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

TV

TV

TV

TV

TV

TV

TV

TV

TV

W

W

141st COS

92nd FLT. SAFETY

ELEV.

E001

JAN.

100C

SM. CONF. RM

92nd/141st GND.

SAFETY

107A

W.S.M.

107D

MEN

105 STAIR

S001

LOBBY

100A

VEST.

100B

WOMEN

101E

AV

101D

COURT ROOM

101B

STOR.

101C

CORRIDOR

C003

JURY DELIB.

102A

RECEPTION

CT. RM. VEST.

101A

JUDGE

CHAMBERS

103A

TOILET

103B

TOILET

102B

CCL

CEL

W.W. DEF WIT.

W.W. GOV'T.

RES. ATTY

OIC

OIC

L.O.S.

DSJA

SJA

LGL. ASST.

CORRIDOR

C002

LIB. CONF

NCOIC

127B

FILE STOR

100D

CIV. LAW

127A

CT. REP.

FILE STOR 2

125A

COC

BREAK

NCOIC

146 PARAL. OPEN

OFFICE

STAIR

S003

/1 T-10

X.AX.B

X.D

X.4 X.5

X.6

X.6

Z.DZ.D

A

A

Z.6

Z.6

Z.5

Z.5

Z.4

Z.4

Z.3

Z.3

Z.1

Z.1

Z.B

Z.C Z.C

Z.2

Z.A

P

P

P

P

P

E

X.7

X.7

T-704

(4) 4" CONDUITS TO

TRAY ABOVE AV ROOM

(2) 4" CONDUITS

18"x6" TRAY (TYP)

12" LADDER RACK

ABOVE CEILING

(4) 4" SLEEVES UP

TO SECOND FLOOR

COMM ROOM

COORDINATE KIOSK OUTLETS WITH

ARCHITECTURAL AND INTERIORS

V

V

P

P

P

VP

VP

VP

VP

T-708

SECURE VIDEO TELECONFERENCE

EQUIPMENT(BY OTHERS)

(1) 2" CONDUIT TO EACH

PROJECTOR FOR A/V SYSTEM

(CABLING BY OTHERS)

AV

AV

AV AV

AV

AV

AV

AV AV

AV

AV

AV

AV

AV

COORDINATE WALL PHONE

LOCATION AND HEIGHT

WITH CARD READER

AV

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y

D E

SI

G

N B

Y:

S

BM

T B

Y:

S

IZ

E

FI

LE

N A

M E:

IS

S

U E

D

AT

E

C O

N

TR

AC

T

N O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

CO

R

PS

O

F

EN

G

IN

EE

R

S

C K

D B

Y

US Army Corps of Engineers ®

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T S

C

AL

E

P

LO

T D

A

TE

SHEET OF

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

/8

'-0

7/ 8/

:3

1:

A M

FY

W in g He ad qu ar te rs

JU

LY

W

2D W

W

2D W

-1 2-

C -0

Seattle District

G . S

AY

ER

L.

F

LO

R

ES

C

A

G . S

AY

ER

P N

G

JK

Z8 6-

-E

LE

C -C

EN

TR

A L.

rv t

6/

1-

-1

T-101

S

EA

TT

LE

D

IS

TR

IC

T S

EA

TT

LE

, W

AS

H

IN

G

TO

N

R . R

AU

C

H

C O

M M

U N

IC

A

TI

O

N S

FI

R

ST

F

LO

O

R

PL

AN

EA

ST

W

IN

G

P R

O

JE

C T

N A

M E

T -1

Final Design - Issued For Construction (Submittal #5)

P ro je ct

N um be r

1/8" = 1'-0"T-101

COMMUNICATIONS FIRST FLOOR PLAN - EAST

WING

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

GENERAL NOTES:

1. REFER TO ARCHITECTURAL PLANS INTERIOR

ELEVATIONS FOR DIMENSIONED WALL

RECEPTACLE LOCATIONS.

CABLE TRAY SHALL BE INSTALLED WITH WALL

ANGLE BRACKETS. USE OF THREADED ROD AND

TRAPEZE STRUCTURES IS NOT ALLOWED.

ALL OUTLETS SHALL BE PROVIDED WITH (1) 1"

CONDUIT ROUTED TO NEAREST CABLE TRAY AND

TERMINATED WITH INSULATED BUSHING.

COORDINATE ALL OUTLETS WITH

ARCHITECTURAL AND INTERIORS PLANS FOR

EXACT LOCATIONS PRIOR TO ROUGH-IN.

ALL CONDUITS SHALL BE TERMINATED WITH

BUSHINGS TO PREVENT DAMAGE TO CABLING.

2.

3.

4.

5.

KEY NOTES:

AV OUTLET. PROVIDE (1) 2" CONDUIT TO AV ROOM.

COORDINATE WITH GOVERNMENT AND AV

CONTRACTOR FOR ADDITIONAL DETAILS.

PROJECTOR CONNECTION. PROVIDE (1) 2"

CONDUIT FROM OUTLET BOX TO PROJECTOR FOR

AV. PROVIDE CABLING AS REQUIRED FOR GFGI

PROJECTORS AND SPEAKERS.

COMBINATION POWER AND COMMUNICATIONS

FLUSH FLOOR BOX. COORDINATE WITH

ELECTRICAL SHEETS.

PROVIDE CONDUIT AND OUTLET BOX FOR

ELEVATOR PHONE. COORDINATE WITH ELEVATOR

INSTALLER.

PROVIDE (1) AUDIO/VISUAL OUTLET AT 18" FOR

LECTURN CONNECTION.

1 1

1 1

M A

R K

D E

SC

R

IP

TI

O N

D A

TE

A

PP

R

262 284